| Type | Act. | sensemble | Date Planif/Appel | Date arrivée | Date Départ | OS | Cas THD | Description | constat | Défaut | Action | Composant | Type appel | Condition au départ | Dernier Technicien |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YSM1 | Y03 | 27/02/2026 00:00:00 | 27/02/2026 12:24:36 | 27/02/2026 12:37:45 | 869948830 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2026 00:00:00 | 22/01/2026 11:31:04 | 22/01/2026 13:44:32 | 868027406 | EG : équipement gaine - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2026 00:00:00 | 22/01/2026 11:31:04 | 22/01/2026 13:44:32 | 868027406 | MA : manoeuvre - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2026 00:00:00 | 22/01/2026 11:31:04 | 22/01/2026 13:44:32 | 868027406 | PC : opérateur porte cabine - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2026 00:00:00 | 22/01/2026 11:31:04 | 22/01/2026 13:44:32 | 868027406 | PP : portes palières - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2026 00:00:00 | 22/01/2026 11:31:04 | 22/01/2026 13:44:32 | 868027406 | SI : signalisation - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2026 00:00:00 | 22/01/2026 11:31:04 | 22/01/2026 13:44:32 | 868027406 | TR : treuil ou machine - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 16/01/2026 00:00:00 | 16/01/2026 08:47:16 | 16/01/2026 09:02:21 | 866324631 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM3 | Y04 | 03/12/2025 12:40:18 | 03/12/2025 12:50:50 | 03/12/2025 13:08:51 | 9AFR75606273 | Travail supplémentaire réalisé pendant les travaux et réparations n° 325188177 - | Defaut technique | Graisser/Lubrifier | Guides et fixations - Guides cabine | Remis en service |
GOMES Marc (TM)
(+) |
||||
| YSM6 | Y04 | 21/11/2025 00:00:00 | 03/12/2025 12:41:18 | 03/12/2025 12:50:50 | 325188177 | GRILLE AÉRATION ALU (1 GRILLE+FIX) - Grille Ventillation-PARIS 06/10 ST MICHE | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 05/12/2025 00:00:00 | 03/12/2025 08:30:21 | 03/12/2025 08:43:32 | 864008846 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 31/10/2025 00:00:00 | 24/10/2025 08:35:12 | 24/10/2025 08:49:23 | 861272972 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/07/2025 00:00:00 | 18/09/2025 13:02:12 | 18/09/2025 13:29:16 | 854389187 | LC : Legal complementaire - MC LC | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/07/2025 00:00:00 | 18/09/2025 13:02:12 | 18/09/2025 13:29:16 | 854389187 | MC : module complet - MC LC | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 19/09/2025 00:00:00 | 18/09/2025 12:58:56 | 18/09/2025 13:02:12 | 858217851 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM3 | Y01 | 17/09/2025 09:44:53 | 18/09/2025 12:00:38 | 18/09/2025 12:57:58 | 9AFR75476205 | MME SEMEDO ,Ascenseur à l'étage porte fermée// PMR URGENT - | Indisponible - Arrêté entre étage - Porte palière fermée | Defaut technique | Vérifier | Systeme de commande - Module de commande | Haute priorité | Remis en service |
GOMES Marc (TM)
(+) |
||
| YSM3 | Y04 | 08/08/2025 17:08:53 | 08/08/2025 17:12:29 | 08/08/2025 17:26:01 | 9AFR75416155 | Travail non prévu effectué pendant l'opération de maintenance n° 853936604 - | Defaut technique | Régler | Porte et huisserie - Porte paliere (battante) - Cadre et linteaux | Remis en service |
GOMES Marc (TM)
(+) |
||||
| YSM1 | Y03 | 25/07/2025 00:00:00 | 08/08/2025 17:09:53 | 08/08/2025 17:12:29 | 853936604 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM1 | Y04 | KCO_24_7_ACT | 30/04/2025 00:00:00 | 01/07/2025 08:57:00 | 01/07/2025 11:28:00 | 850687234 | KONE 24/7 ACTIVATION - KONE 24/7 ACTIVATION KC360 | M. Remy PINCE (RGL) | |||||||
| YSM1 | Y03 | 13/06/2025 00:00:00 | 13/06/2025 10:54:13 | 13/06/2025 11:02:41 | 851006431 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM3 | Y01 | 09/05/2025 15:08:50 | 10/05/2025 08:53:01 | 10/05/2025 10:00:24 | 9AFR75253053 | ME MOUTHON ,Défaut // RACLE LE SOL AU RDC // SE BLOQUE PAR INTERMITTENCE // PMR - | Disponible - Aucun défaut constaté | Defaut technique | Vérifier | Cabine - Trappe de secours | Basse priorité | Remis en service |
GOMES Marc (TM)
(+) |
||
| YSM1 | Y03 | 02/05/2025 00:00:00 | 02/05/2025 08:43:18 | 02/05/2025 09:00:28 | 847346949 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM3 | Y04 | 19/03/2025 08:42:12 | 19/03/2025 08:48:02 | 19/03/2025 09:27:15 | 9AFR75162269 | Travail non prévu effectué pendant l'opération de maintenance n° 832454360 - | Defaut technique | Remplacer | Signalisation - Palière - Boutons d'appel - Carte | Remis en service |
GOMES Marc (TM)
(+) |
||||
| YSM1 | Y03 | 21/03/2025 00:00:00 | 19/03/2025 08:43:12 | 19/03/2025 08:48:02 | 832454360 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM1 | Y07 | 04/11/2024 00:00:00 | 03/02/2025 16:49:00 | 03/02/2025 16:50:57 | 778711000 | afficher instruc manoeuvre secours - KONE mainteneur(IR309898254) | DOS SANTOS PINTO David (RE) | ||||||||
| YSM1 | Y07 | 04/11/2024 00:00:00 | 03/02/2025 16:49:00 | 03/02/2025 16:50:57 | 778711000 | tracer reperes niveaux cables - KONE mainteneur(IR309898254) | DOS SANTOS PINTO David (RE) | ||||||||
| YSM3 | Y04 | 03/02/2025 12:29:43 | 03/02/2025 13:12:14 | 03/02/2025 13:17:27 | 9AFR75081225 | Travail non prévu effectué pendant l'opération de maintenance n° 830840596 - | Defaut technique | Régler | Câbles - Contact mou de cable | Remis en service |
GOMES Marc (TM)
(+) |
||||
| YSM1 | Y03 | 21/02/2025 00:00:00 | 03/02/2025 12:30:43 | 03/02/2025 13:12:14 | 830840596 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM3 | Y04 | 14/01/2025 14:48:01 | 31/01/2025 13:50:56 | 31/01/2025 15:11:27 | 9AFR75042158 | MR MOUTON ,Service Client / BOUTON PALIER RDC NE ALLUME PAS/ ASC FONCTIONNEL / BESOIN D ETTIQUETTE SUR LES PORTE - | Disponible - Dysfonctionnement autre | Defaut technique | Remplacer | Signalisation - Palière - Boutons d'appel - Carte | Basse priorité | Remis en service |
GOMES Marc (TM)
(+) |
||
| YSM1 | Y03 | 17/01/2025 00:00:00 | 09/01/2025 08:14:50 | 09/01/2025 08:16:24 | 827735144 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2025 00:00:00 | 09/01/2025 07:44:17 | 09/01/2025 08:14:50 | 829053760 | PC : opérateur porte cabine - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2025 00:00:00 | 09/01/2025 07:44:17 | 09/01/2025 08:14:50 | 829053760 | PP : portes palières - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 06/12/2024 00:00:00 | 02/12/2024 09:29:55 | 02/12/2024 09:40:19 | 824707759 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM3 | Y01 | 26/10/2024 12:17:00 | 27/10/2024 14:13:33 | 27/10/2024 15:12:02 | 9AFR74889242 | MR MOUTHON ,BLQ FERME PMR ATTEND EN BAS / BLQ ENTRE 4E/5E - | Indisponible - Arrêté entre étage - Porte palière fermée | Defaut technique | Remise a zero (reset) | Systeme de commande - Carte electronique | Haute priorité | Remis en service |
TRAN Seng (TM)
(+) |
||
| YSM1 | Y03 | 25/10/2024 00:00:00 | 21/10/2024 10:11:16 | 21/10/2024 10:31:52 | 822073340 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 20/09/2024 00:00:00 | 12/09/2024 13:40:40 | 12/09/2024 13:41:37 | 819692264 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 16/08/2024 00:00:00 | 09/08/2024 16:28:29 | 09/08/2024 16:38:54 | 816972800 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/07/2024 00:00:00 | 01/07/2024 15:10:52 | 01/07/2024 15:29:01 | 816025845 | LC : Legal complementaire - MC LC | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/07/2024 00:00:00 | 01/07/2024 15:10:52 | 01/07/2024 15:29:01 | 816025845 | MC : module complet - MC LC | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 05/07/2024 00:00:00 | 01/07/2024 15:00:06 | 01/07/2024 15:10:52 | 814281881 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM3 | Y01 | 27/05/2024 15:03:04 | 28/05/2024 16:15:59 | 28/05/2024 16:41:01 |
9AFR74600296
Repet. |
MME FEMEDO ,Ascenseur à l'étage porte fermée/ - | Indisponible - Arrêté entre étage - Porte palière fermée | Defaut technique | Régler | Systeme de commande - Module de commande | Haute priorité | Remis en service |
BEN HAMMOU Aziz (TS)
(+) |
||
| YSM3 | Y02 | 25/05/2024 22:40:00 | 25/05/2024 23:31:35 | 26/05/2024 12:45:43 | 9AFR74597873 | TS ,ARRET TM// TS Personne bloquée - | Indisponible - Arrêté entre étage - Porte palière fermée | Defaut technique | Vérifier | Systeme de commande - Module de commande | Urgence Sécurité | Remis en service |
OKOLA-CAMBAT Roland Jérôme (TM)
(+) |
||
| YSM1 | Y03 | 01/01/2024 00:00:00 | 23/05/2024 09:13:34 | 23/05/2024 09:54:00 | 803396462 | EG : équipement gaine - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2024 00:00:00 | 23/05/2024 09:13:34 | 23/05/2024 09:54:00 | 803396462 | MA : manoeuvre - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2024 00:00:00 | 23/05/2024 09:13:34 | 23/05/2024 09:54:00 | 803396462 | PC : opérateur porte cabine - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2024 00:00:00 | 23/05/2024 09:13:34 | 23/05/2024 09:54:00 | 803396462 | PP : portes palières - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2024 00:00:00 | 23/05/2024 09:13:34 | 23/05/2024 09:54:00 | 803396462 | SI : signalisation - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2024 00:00:00 | 23/05/2024 09:13:34 | 23/05/2024 09:54:00 | 803396462 | TR : treuil ou machine - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 10/05/2024 00:00:00 | 23/05/2024 08:43:13 | 23/05/2024 09:13:34 | 810115516 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM1 | Y04 | 28/03/2024 00:00:00 | 29/03/2024 13:02:00 | 29/03/2024 15:29:00 | 810165264 | Commande - COULISSEAU | Gomes Marc (TM) | ||||||||
| YSM3 | Y04 | 27/03/2024 13:07:28 | 27/03/2024 13:13:51 | 27/03/2024 15:17:44 | 9AFR74495791 | Travail non prévu effectué pendant l'opération de maintenance n° 803396462 - | Composant use (remplacement preventif) | Vérifier | Contrepoids - Coulisseaux - Coulisseaux | Remis en service |
GOMES Marc (TM)
(+) |
||||
| YSM3 | Y04 | 26/03/2024 10:43:39 | 26/03/2024 10:58:47 | 26/03/2024 13:46:47 | 9AFR74493142 | Travail non prévu effectué pendant l'opération de maintenance n° 805587441 - | Composant use (remplacement preventif) | Remplacer | Etrier cabine - Coulisseaux | Remis en service |
GOMES Marc (TM)
(+) |
||||
| YSM1 | Y03 | 08/03/2024 00:00:00 | 26/03/2024 09:44:39 | 26/03/2024 09:58:47 | 805587441 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/12/2023 00:00:00 | 24/01/2024 14:09:46 | 24/01/2024 14:21:31 | 799629469 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 20/10/2023 00:00:00 | 19/10/2023 11:35:54 | 19/10/2023 11:58:46 | 796674292 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 25/08/2023 00:00:00 | 08/09/2023 10:10:00 | 08/09/2023 10:23:00 | 792533058 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM3 | Y01 | 14/08/2023 08:59:03 | 08/09/2023 09:13:47 | 08/09/2023 10:09:03 |
9AFR74051058
Repet. |
M STEPHANI ,Panne - | Disponible - Aucun défaut constaté | Aucun defaut constate | Graisser/Lubrifier | Porte et huisserie - Porte cabine - Contact de porte | Haute priorité | Remis en service |
GOMES Marc (TM)
(+) |
||
| YSM3 | Y01 | 10/08/2023 11:05:21 | 10/08/2023 14:05:00 | 10/08/2023 14:50:00 | 9AFR74045958 | VAN DE RIEVIERE STEPHANI ,Panne - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Systeme de commande - Module de commande | Haute priorité | Remis en service |
GOMES Marc (TM)
(+) |
||
| YSM1 | Y03 | 28/07/2023 00:00:00 | 12/07/2023 13:20:00 | 12/07/2023 13:36:00 | 790426990 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM3 | Y04 | 12/07/2023 11:08:29 | 12/07/2023 11:20:00 | 12/07/2023 13:20:00 | 9AFR73994244 | Travail non prévu effectué pendant l'opération de maintenance n° 791383203 - | Composant use (remplacement preventif) | Remplacer | Porte et huisserie - Porte palière (auto) - Ferme porte (contrepoids,ressort) | Remis en service |
GOMES Marc (TM)
(+) |
||||
| YSM1 | Y03 | 01/07/2023 00:00:00 | 12/07/2023 10:15:00 | 12/07/2023 11:20:00 | 791383203 | LC : Legal complementaire - MC LC | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/07/2023 00:00:00 | 12/07/2023 10:15:00 | 12/07/2023 11:20:00 | 791383203 | MC : module complet - MC LC | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 02/06/2023 00:00:00 | 12/06/2023 13:36:32 | 12/06/2023 13:41:47 | 787828131 | MB : module de base - | Ben Hammou Aziz (TS) | ||||||||
| YSM3 | Y01 | 10/06/2023 14:58:13 | 12/06/2023 12:05:03 | 12/06/2023 13:36:32 | 9AFR73927805 | M BOUDY ,Ascenseur à l'étage porte fermée - | Indisponible - Arrêté entre étage - Porte palière fermée | Defaut technique | Régler | Systeme de commande - Module de commande | Haute priorité | Remis en service |
BEN HAMMOU Aziz (TS)
(+) |
||
| YSM3 | Y01 | 28/04/2023 12:06:26 | 03/05/2023 13:53:35 | 03/05/2023 14:40:07 | 9AFR73851811 | MME TARICE ,Ascenseur à l'étage porte fermée MATERIEL COINCE - | Disponible - Dysfonctionnement autre | Utilisation anormale | Régler | Systeme de commande - Module de commande | Haute priorité | Remis en service |
BEN HAMMOU Aziz (TS)
(+) |
||
| YSM1 | Y03 | 05/05/2023 00:00:00 | 20/04/2023 13:15:44 | 20/04/2023 13:16:23 | 785456826 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2023 00:00:00 | 20/04/2023 13:14:13 | 20/04/2023 13:15:44 | 777628670 | EG : équipement gaine - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2023 00:00:00 | 20/04/2023 13:14:13 | 20/04/2023 13:15:44 | 777628670 | MA : manoeuvre - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2023 00:00:00 | 20/04/2023 13:14:13 | 20/04/2023 13:15:44 | 777628670 | PC : opérateur porte cabine - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2023 00:00:00 | 20/04/2023 13:14:13 | 20/04/2023 13:15:44 | 777628670 | PP : portes palières - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2023 00:00:00 | 20/04/2023 13:14:13 | 20/04/2023 13:15:44 | 777628670 | SI : signalisation - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y03 | 01/01/2023 00:00:00 | 20/04/2023 13:14:13 | 20/04/2023 13:15:44 | 777628670 | TR : treuil ou machine - PC PP EG TR MA SI | Gomes Marc (TM) | ||||||||
| YSM1 | Y07 | 06/03/2023 00:00:00 | 20/04/2023 09:42:38 | 20/04/2023 13:15:08 | 778711000 | RES éclairage gaine - KONE mainteneur(IR309898254) | Gomes Marc (TM) | ||||||||
| YSM1 | Y04 | KCO_CLINICA | 30/06/2022 00:00:00 | 24/03/2023 10:51:00 | 24/03/2023 10:52:00 | 759929085 | Action Clinica Parc Prioritaire - CLI : Action Clinica Prioritaire | Gomes Marc (TM) | |||||||
| YSM1 | Y03 | 20/01/2023 00:00:00 | 24/03/2023 09:01:49 | 24/03/2023 10:51:56 | 776681708 | MB : module de base - | Gomes Marc (TM) | ||||||||
| YSM3 | Y01 | 20/12/2022 17:30:47 | 22/12/2022 15:23:22 | 22/12/2022 16:03:05 | 9AFR73618596 | MR MOUTHON ,Panne PAS DE PRECISION - | Disponible - Dysfonctionnement autre | Defaut technique | Régler | Porte et huisserie - Porte palière (auto) - Serrure - Serrure | Haute priorité | Remis en service |
TOURE Mahmoudou (TM)
(+) |
||
| YSM3 | Y01 | 15/12/2022 11:02:50 | 18/12/2022 08:27:28 | 18/12/2022 09:45:47 | 9AFR73606905 | MR MOUTHON ,Panne ASC A VERIFIER SUITE PERSONNE BLQ AU 4° - | Disponible - Dysfonctionnement autre | Defaut technique | Vérifier | Porte et huisserie - Porte paliere (battante) - Serrure | Haute priorité | Remis en service |
CHOWTHEE Azhar ()
(+) |
||
| YSM1 | Y03 | 02/12/2022 00:00:00 | 09/12/2022 15:23:32 | 09/12/2022 15:40:00 | 773451547 | MB : module de base - | Gonzalez Sarria Milton (TM) | ||||||||
| YSM1 | Y03 | 01/07/2022 00:00:00 | 20/10/2022 14:29:11 | 20/10/2022 14:42:49 | 760528230 | MB : module de base - | Gonzalez Sarria Milton (TM) | ||||||||
| YSM3 | Y04 | 24/09/2022 09:55:54 | 25/09/2022 11:01:38 | 25/09/2022 12:09:01 | 9AFR73449747 | TS ,suite a défaut sur porte 5eme voir pour remise en service ou condamnation de l étage - | Indisponible - Arrêté au niveau - Porte ouverte | Vetuste | Réparer | Porte et huisserie - Porte palière (battante) - Panneaux et seuil - Panneaux | Basse priorité | Remis en service |
MAHBOOB Tabraiz Hussain ()
(+) |
||
| YSM1 | Y03 | 01/07/2022 00:00:00 | 07/07/2022 13:24:21 | 07/07/2022 14:19:44 | 762741649 | LC : Legal complementaire - MC LC | Beaubrun Rytchy Alexandro () | ||||||||
| YSM1 | Y03 | 01/07/2022 00:00:00 | 07/07/2022 13:24:21 | 07/07/2022 14:19:44 | 762741649 | MC : module complet - MC LC | Beaubrun Rytchy Alexandro () | ||||||||
| YSM3 | Y01 | 01/07/2022 10:41:34 | 01/07/2022 15:34:17 | 01/07/2022 17:00:00 | 9AFR73293740 | MR VALAUD ,Ascenseur BLQ AU 5EME ETG porte fermée / RECURRENT - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Porte et huisserie - Porte paliere (battante) - Mecanisme de porte | Haute priorité | Remis en service |
BEAUBRUN Rytchy Alexandro ()
(+) |
||
| YSM3 | Y01 | 24/06/2022 09:27:39 | 24/06/2022 11:06:36 | 24/06/2022 12:28:18 | 9AFR73279675 | MR VALAUD ,Panne ASC BLOQUE AU 5E PORTE FERME RECCURENT - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Régler | Porte et huisserie - Porte paliere (battante) - Serrure | Haute priorité | Remis en service |
BEAUBRUN Rytchy Alexandro ()
(+) |
||
| YSM3 | Y01 | 17/06/2022 10:51:11 | 17/06/2022 13:36:47 | 17/06/2022 14:28:59 | 9AFR73264475 | MR VALAUD ,Défaut porte FERME PTE 5° A REGLER DIFFICULTE A OUVERTURE POUR LES PMR / URGT - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Régler | Porte et huisserie - Porte palière (battante) - Ferme porte - Ferme porte | Haute priorité | Remis en service |
BEAUBRUN Rytchy Alexandro ()
(+) |
||
| YSM6 | Y04 | 16/06/2022 00:00:00 | 16/06/2022 08:37:58 | 16/06/2022 11:05:20 | 323495603 | REMPL FERME PORTE - FERME PORTE - FONCIA PARIS RIVE GAUCHE, | Ben Hammou Aziz (TS) | ||||||||
| YSM3 | Y01 | 07/06/2022 11:16:42 | 07/06/2022 17:09:29 | 07/06/2022 17:32:24 | 9AFR73243979 | M BOUDY ,Ascenseur à l'étage porte fermée / 5EME / PB RECURRENT / - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Porte et huisserie - Porte palière (battante) - Ferme porte - Ferme porte | Haute priorité | Remis en service |
BEAUBRUN Rytchy Alexandro ()
(+) |
||
| YSM3 | Y01 | 01/06/2022 11:15:42 | 02/06/2022 08:23:05 | 02/06/2022 09:17:43 | 9AFR73234423 | MR BOUDY ,Ascenseur à l'étage porte fermée AU 5 ETG - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Porte et huisserie - Porte palière (battante) - Ferme porte - Ferme porte | Haute priorité | Remis en service |
BEAUBRUN Rytchy Alexandro ()
(+) |
||
| YSM3 | Y01 | 26/05/2022 15:40:29 | 30/05/2022 13:39:21 | 30/05/2022 15:06:29 | 9AFR73225450 | MR BOUDY ,Ascenseur à l'étage porte fermée / RECURRENT - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Régler | Porte et huisserie - Porte palière (battante) - Porte palière (battante) | Haute priorité | Remis en service |
BEAUBRUN Rytchy Alexandro ()
(+) |
||
| YSM1 | Y03 | 13/05/2022 00:00:00 | 19/05/2022 14:28:11 | 19/05/2022 14:34:43 | 757063638 | MB : module de base - | Beaubrun Rytchy Alexandro () | ||||||||
| YSM3 | Y01 | 18/05/2022 18:20:38 | 19/05/2022 13:50:08 | 19/05/2022 14:28:11 | 9AFR73211989 | ME MOUTHON ,Ascenseur à l'étage porte fermée / 5EME / PMR SUR PLACE URGENT / - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Porte et huisserie - Porte palière (battante) - Ferme porte - Ferme porte | Haute priorité | Remis en service |
BEAUBRUN Rytchy Alexandro ()
(+) |
||
| YSM3 | Y01 | 17/05/2022 14:41:04 | 18/05/2022 14:44:03 | 18/05/2022 15:37:49 | 9AFR73208024 | M GARNIER ,Ascenseur à l'étage porte ouverte 5EME ETG // PORTE CAB QUI GRINCE - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Porte et huisserie - Porte palière (battante) - Porte palière (battante) | Haute priorité | Remis en service |
BEAUBRUN Rytchy Alexandro ()
(+) |
||
| YSM3 | Y01 | 14/05/2022 14:43:17 | 14/05/2022 16:22:00 | 14/05/2022 17:04:19 | 9AFR73202914 | MR LAOS ,TS Personne bloquée - | Indisponible - Arrêté entre étage - Porte palière fermée | Defaut technique | Régler | Porte et huisserie - Porte cabine - Porte cabine | Urgence Sécurité | Remis en service |
GONZALEZ SARRIA Milton (TM)
(+) |
||
| YSM3 | Y01 | 30/04/2022 16:24:09 | 01/05/2022 10:10:39 | 01/05/2022 10:52:11 | 9AFR73178266 | ME MOUTHON ,Panne / 5EME / PB RECURRENT / - | Disponible - Dysfonctionnement autre | Aucun defaut constate | Vérifier | Porte et huisserie - Porte paliere (battante) - Serrure | Haute priorité | Remis en service |
DA CONCEICAO Toni (TM)
(+) |
||
| YSM1 | Y03 | 25/03/2022 00:00:00 | 01/04/2022 14:47:31 | 01/04/2022 15:00:46 | 753350170 | MB : module de base - | Beaubrun Rytchy Alexandro () | ||||||||
| YSM3 | Y01 | 21/03/2022 15:54:41 | 22/03/2022 13:40:02 | 22/03/2022 14:34:16 | 9AFR73106595 | ME LAROUSSE ,Panne 5ETG - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Régler | Porte et huisserie - Porte paliere (battante) - Contact de porte | Haute priorité | Remis en service |
CHOWTHEE Azhar ()
(+) |
||
| YSM3 | Y01 | 18/03/2022 11:22:26 | 18/03/2022 15:46:02 | 18/03/2022 16:53:36 | 9AFR73102049 | MR BOUDY ,Panne - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Machinerie - Autres composants machinerie | Haute priorité | Remis en service |
BEAUBRUN Rytchy Alexandro ()
(+) |
||
| YSM3 | Y01 | 13/02/2022 15:39:09 | 13/02/2022 16:23:48 | 13/02/2022 17:03:28 | 9AFR73043413 | M BOUDY ,Ascenseur à l'étage porte fermée AU 4EME - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Régler | Porte et huisserie - Porte paliere (battante) - Serrure | Haute priorité | Remis en service |
SENOTIER Marcial (TM)
(+) |
||
| YSM1 | Y03 | 11/02/2022 00:00:00 | 11/02/2022 09:44:00 | 11/02/2022 09:57:40 | 750466013 | MB : module de base - | Beaubrun Rytchy Alexandro () | ||||||||
| YSM3 | Y01 | 10/02/2022 18:05:27 | 11/02/2022 06:58:57 | 11/02/2022 09:43:22 | 9AFR73039971 | MME MOUTHON ,ARRET TM défaut technique /Panne // BLQ 5EME - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Système de commande - Système de commande | Haute priorité | Remis en service |
BEAUBRUN Rytchy Alexandro ()
(+) |
||
| YSM1 | Y03 | 01/01/2022 00:00:00 | 10/01/2022 11:41:09 | 10/01/2022 13:01:49 | 749610000 | EG : équipement gaine - PC PP EG TR MA SI | Haroun Bouranane () | ||||||||
| YSM1 | Y03 | 01/01/2022 00:00:00 | 10/01/2022 11:41:09 | 10/01/2022 13:01:49 | 749610000 | MA : manoeuvre - PC PP EG TR MA SI | Haroun Bouranane () | ||||||||
| YSM1 | Y03 | 01/01/2022 00:00:00 | 10/01/2022 11:41:09 | 10/01/2022 13:01:49 | 749610000 | PC : opérateur porte cabine - PC PP EG TR MA SI | Haroun Bouranane () | ||||||||
| YSM1 | Y03 | 01/01/2022 00:00:00 | 10/01/2022 11:41:09 | 10/01/2022 13:01:49 | 749610000 | PP : portes palières - PC PP EG TR MA SI | Haroun Bouranane () | ||||||||
| YSM1 | Y03 | 01/01/2022 00:00:00 | 10/01/2022 11:41:09 | 10/01/2022 13:01:49 | 749610000 | SI : signalisation - PC PP EG TR MA SI | Haroun Bouranane () | ||||||||
| YSM1 | Y03 | 01/01/2022 00:00:00 | 10/01/2022 11:41:09 | 10/01/2022 13:01:49 | 749610000 | TR : treuil ou machine - PC PP EG TR MA SI | Haroun Bouranane () | ||||||||
| YSM1 | Y03 | 07/01/2022 00:00:00 | 30/12/2021 10:38:42 | 30/12/2021 10:45:30 | 747742892 | MB : module de base - | M. Bouranane HAROUN () | ||||||||
| YSM3 | Y01 | 09/12/2021 18:34:31 | 09/12/2021 21:39:19 | 11/12/2021 10:50:18 | 9AFR72924876 | M MOUTHON ,Défaut porte 5EME ETG QUI SE BLQ PAR INTERMITTENCE ET BLQ L'ASC - | Defaut technique | Régler | Porte et huisserie - Porte paliere (battante) - Cadre et linteaux | Haute priorité | Remis en service |
GONZALEZ SARRIA Milton (TM)
(+) |
|||
| YSM3 | Y01 | 01/12/2021 11:41:23 | 07/12/2021 15:38:24 | 07/12/2021 16:24:18 | 9AFR72905661 | MR VALLAUD ,Défaut porte FROTTE AU RDC // SCOTCH SUR BOUTON DU 5EME INT CAB POUR EMPECHER ASC DE MONTER AU 5// APPELER CLT POUR INFO SUR BOUTO - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Régler | Systeme de commande - Carte electronique | Haute priorité | Remis en service |
HAROUN Bouranane ()
(+) |
||
| YSM1 | Y03 | 29/10/2021 00:00:00 | 25/11/2021 15:23:57 | 25/11/2021 15:49:07 | 742520040 | MB : module de base - | Haroun Bouranane () | ||||||||
| YSM3 | Y01 | 24/11/2021 15:03:36 | 24/11/2021 17:33:26 | 24/11/2021 18:09:09 | 9AFR72891436 | MR VALLAUD ,Ascenseur panne porte fermée rdc /ps ref cab a ext com inter jean-paul.vallaud@foncia.fr envoyer ivt + Régler porte rdc - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Régler | Porte et huisserie - Porte palière (battante) - Panneaux et seuil - Paumelles | Haute priorité | Remis en service |
CHOWTHEE Azhar ()
(+) |
||
| YSM1 | Y03 | 06/08/2021 00:00:00 | 14/09/2021 10:00:08 | 14/09/2021 10:28:49 | 736627656 | MB : module de base - | Haroun Bouranane () | ||||||||
| YSM1 | Y03 | 01/07/2021 00:00:00 | 13/07/2021 15:49:14 | 13/07/2021 16:55:19 | 736642488 | LC : Legal complementaire - MC LC | M. Bouranane HAROUN () | ||||||||
| YSM1 | Y03 | 01/07/2021 00:00:00 | 13/07/2021 15:49:14 | 13/07/2021 16:55:19 | 736642488 | MC : module complet - MC LC | M. Bouranane HAROUN () | ||||||||
| YSM1 | Y03 | 25/06/2021 00:00:00 | 22/06/2021 14:11:19 | 22/06/2021 14:24:58 | 733658301 | MB : module de base - | Haroun Bouranane () | ||||||||
| YSM1 | Y03 | 21/05/2021 00:00:00 | 11/05/2021 16:05:31 | 11/05/2021 16:23:31 | 731780225 | MB : module de base - | M. Bouranane HAROUN () | ||||||||
| YSM3 | Y04 | 08/04/2021 10:15:20 | 08/04/2021 10:38:59 | 08/04/2021 11:26:34 | 9AFR72436493 | HAROUN Bouranane ,Travail non prévu effectué pendant l'opération de maintenance n° 728501326 , ExWk - | Defaut technique | Régler | Porte et huisserie - Porte cabine - Porte cabine | Remis en service |
HAROUN Bouranane ()
(+) |
||||
| YSM1 | Y03 | 09/04/2021 00:00:00 | 08/04/2021 10:16:20 | 08/04/2021 10:38:59 | 728501326 | MB : module de base - | Haroun Bouranane () | ||||||||
| YSM1 | Y03 | 12/02/2021 00:00:00 | 22/02/2021 15:18:47 | 22/02/2021 15:37:46 | 725438403 | MB : module de base - | Haroun Bouranane () | ||||||||
| YSM3 | Y01 | 20/01/2021 19:54:15 | 20/01/2021 20:45:20 | 20/01/2021 21:24:02 | 9AFR72287310 | MR TOURE ,TS Personne bloquée - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Régler | Porte et huisserie - Porte paliere (battante) - Came et contacts de commande | Urgence Sécurité | Remis en service |
NAGAU Jonathan (TM)
(+) |
||