Liste des Ordres de Service de l'équipement 10587718
Liste des Ordres de Service
109 ordres de services trouvés
| Type | Act. | sensemble | Date Planif/Appel | Date arrivée | Date Départ | OS | Cas THD | Description | constat | Défaut | Action | Composant | Type appel | Condition au départ | Dernier Technicien |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YSM1 | Y03 | 27/02/2026 00:00:00 | 24/02/2026 14:10:50 | 24/02/2026 14:22:12 | 869702057 | MB : module de base - | TRANCHANT Stéphane (TM) | ||||||||
| YSM1 | Y04 | KCO_CLINICA | 04/07/2025 00:00:00 | 02/02/2026 13:37:00 | 02/02/2026 17:05:00 | 852081960 | Action Clinica Parc Prioritaire - CLI : Action Clinica Prioritaire | TRANCHANT Stéphane (TM) | |||||||
| YSM1 | Y04 | 29/09/2025 00:00:00 | 14/01/2026 11:24:00 | 14/01/2026 11:46:00 | 861795742 | COMMANDE - COMMANDE CARTE REPAREE | TRANCHANT Stéphane (TM) | ||||||||
| YSM1 | Y03 | 09/01/2026 00:00:00 | 14/01/2026 11:09:17 | 14/01/2026 11:24:57 | 866206334 | MB : module de base - | TRANCHANT Stéphane (TM) | ||||||||
| YSM3 | Y01 | 30/12/2025 09:43:01 | 31/12/2025 08:35:25 | 31/12/2025 12:01:24 | 9AFR75648709 | - M. CHEVALIER ,Ascenseur à l'étage porte fermée // AU 3 ETG - | Indisponible - Arrêté entre étage - Porte palière fermée | Defaut technique | Régler | Etrier cabine - Parachute - Contact | Haute priorité | Remis en service |
TRANCHANT Stéphane (TM)
(+) |
||
| YSM3 | Y09 | SN_URGENT | 30/09/2025 11:41:14 | 26/11/2025 16:11:52 | 26/11/2025 16:17:08 | 9AFR75498431 | SN000223 - Défaut d"appel cyclique: AMPHITECH, le système ne fait pas d"appel cyclique | Remis en service |
TRANCHANT Stéphane (TM)
(+) |
||||||
| YSM1 | Y03 | 28/11/2025 00:00:00 | 26/11/2025 15:40:46 | 26/11/2025 15:51:25 | 862997064 | MB : module de base - | TRANCHANT Stéphane (TM) | ||||||||
| YSM1 | Y03 | 01/07/2025 00:00:00 | 26/11/2025 14:59:47 | 26/11/2025 15:40:46 | 854012947 | LC : Legal complementaire - MC LC | TRANCHANT Stéphane (TM) | ||||||||
| YSM1 | Y03 | 01/07/2025 00:00:00 | 26/11/2025 14:59:47 | 26/11/2025 15:40:46 | 854012947 | MC : module complet - MC LC | TRANCHANT Stéphane (TM) | ||||||||
| YSM1 | Y03 | 03/10/2025 00:00:00 | 16/10/2025 11:39:00 | 16/10/2025 12:03:17 | 859158949 | MB : module de base - | TRANCHANT Stéphane (TM) | ||||||||
| YSM1 | Y03 | 01/01/2025 00:00:00 | 16/10/2025 10:12:38 | 16/10/2025 11:39:00 | 828685227 | EG : équipement gaine - PC PP EG TR MA SI | TRANCHANT Stéphane (TM) | ||||||||
| YSM1 | Y03 | 01/01/2025 00:00:00 | 16/10/2025 10:12:38 | 16/10/2025 11:39:00 | 828685227 | MA : manoeuvre - PC PP EG TR MA SI | TRANCHANT Stéphane (TM) | ||||||||
| YSM1 | Y03 | 01/01/2025 00:00:00 | 16/10/2025 10:12:38 | 16/10/2025 11:39:00 | 828685227 | PC : opérateur porte cabine - PC PP EG TR MA SI | TRANCHANT Stéphane (TM) | ||||||||
| YSM1 | Y03 | 01/01/2025 00:00:00 | 16/10/2025 10:12:38 | 16/10/2025 11:39:00 | 828685227 | PP : portes palières - PC PP EG TR MA SI | TRANCHANT Stéphane (TM) | ||||||||
| YSM1 | Y03 | 01/01/2025 00:00:00 | 16/10/2025 10:12:38 | 16/10/2025 11:39:00 | 828685227 | SI : signalisation - PC PP EG TR MA SI | TRANCHANT Stéphane (TM) | ||||||||
| YSM1 | Y03 | 01/01/2025 00:00:00 | 16/10/2025 10:12:38 | 16/10/2025 11:39:00 | 828685227 | TR : treuil ou machine - PC PP EG TR MA SI | TRANCHANT Stéphane (TM) | ||||||||
| YSM1 | Y03 | 15/08/2025 00:00:00 | 22/08/2025 15:17:00 | 22/08/2025 15:31:56 | 855613725 | MB : module de base - | TRANCHANT Stéphane (TM) | ||||||||
| YSM3 | Y01 | 22/08/2025 08:49:42 | 22/08/2025 13:30:00 | 22/08/2025 15:16:37 | 9AFR75434453 | MR ANDOUARD ,Ascenseur à l'étage porte ouverte // AU RDC - | Indisponible - Arrêté au niveau - Porte ouverte | Utilisation anormale | Réparer | Porte et huisserie - Porte cabine - Rail de suspente, panneaux, seuil - Galet porteur | Haute priorité | Remis en service |
TRANCHANT Stéphane (TM)
(+) |
||
| YSM3 | Y01 | 13/08/2025 08:10:34 | 13/08/2025 09:39:47 | 13/08/2025 11:10:03 | 9AFR75421545 | MME BUVRIL ,Ascenseur à l'étage porte fermée / URGENT - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Machinerie - Treuil - Tachymétre, encodeur et résolveur - Balais tachymétre | Haute priorité | Remis en service |
TRANCHANT Stéphane (TM)
(+) |
||
| YSM3 | Y02 | 12/08/2025 07:22:32 | 12/08/2025 08:30:00 | 12/08/2025 10:38:50 | 9AFR75419770 | TS ,TS Personne bloquée - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Cabine - Système de positionnement - Encodeur | Urgence Sécurité | Remis en service |
TRANCHANT Stéphane (TM)
(+) |
||
| YSM1 | Y03 | 04/07/2025 00:00:00 | 01/07/2025 16:43:00 | 01/07/2025 16:56:06 | 852456905 | MB : module de base - | TRANCHANT Stéphane (TM) | ||||||||
| YSM3 | Y01 | 01/07/2025 14:21:10 | 01/07/2025 15:43:50 | 01/07/2025 16:42:40 | 9AFR75355611 | MR ANDOUARD ,Panne / BLOQUE / 5EME / GALET CASSE - | Disponible - Dysfonctionnement autre | Utilisation anormale | Réparer | Porte et huisserie - Porte cabine - Porte cabine | Haute priorité | Remis en service |
TRANCHANT Stéphane (TM)
(+) |
||
| YSM6 | Y04 | 14/02/2025 00:00:00 | 23/05/2025 13:30:00 | 23/05/2025 18:00:00 | 324680991 | Package personnalisé - CCPA Remplacment Groupe de traction asc | M. Gwendal BOUYAULT (TS THD) | ||||||||
| YSM1 | Y03 | 16/05/2025 00:00:00 | 22/05/2025 16:37:00 | 22/05/2025 16:48:33 | 848846301 | MB : module de base - | TRANCHANT Stéphane (TM) | ||||||||
| YSM3 | Y01 | 22/05/2025 12:40:31 | 22/05/2025 15:10:20 | 22/05/2025 16:36:31 | 9AFR75276447 | MR ANDOUARD ,Ascenseur à l'étage porte fermée//URGENT - | Indisponible - Arrêté au niveau - Porte fermée | Composant use (remplacement preventif) | Remise a zero (reset) | Machinerie - Autres composants machinerie | Haute priorité | Remis en service |
TRANCHANT Stéphane (TM)
(+) |
||
| YSM3 | Y01 | 23/04/2025 12:11:14 | 23/04/2025 13:44:14 | 23/04/2025 16:11:38 | 9AFR75225172 | ts ,Ascenseur à l'étage porte ouverte - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Réparer | Porte et huisserie - Porte cabine - Porte cabine | Haute priorité | Remis en service |
TRANCHANT Stéphane (TM)
(+) |
||
| YSM1 | Y03 | 28/03/2025 00:00:00 | 04/04/2025 16:10:37 | 04/04/2025 16:30:45 | 845118314 | MB : module de base - | TRANCHANT Stéphane (TM) | ||||||||
| YSM1 | Y03 | 31/01/2025 00:00:00 | 13/02/2025 10:07:10 | 13/02/2025 10:20:03 | 829079832 | MB : module de base - | TRANCHANT Stéphane (TM) | ||||||||
| YSM3 | Y01 | 24/01/2025 09:21:47 | 24/01/2025 10:31:28 | 24/01/2025 12:00:37 | 9AFR75062623 | MR ANDOUARD ,Défaut fermeture porte : présence d'un cable métallique - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Régler | Porte et huisserie - Porte palière (auto) - Rail de suspente, panneaux, seuil - Composants de synchronisation | Haute priorité | Remis en service |
JOYEUX Guillaume (TM)
(+) |
||
| YSM3 | Y01 | 02/01/2025 11:03:33 | 02/01/2025 15:26:00 | 02/01/2025 17:06:46 | 9AFR75017712 | MR ANDOUAR ,Panne// SATTETE AU PALIER - | Disponible - Dysfonctionnement autre | Defaut technique | Régler | Porte et huisserie - Porte cabine - Opérateur de porte cabine - Composant électrique opérateur | Haute priorité | Remis en service |
BOUYAULT Gwendal (TS THD)
(+) |
||
| YSM1 | Y03 | 13/12/2024 00:00:00 | 19/12/2024 08:40:25 | 19/12/2024 09:00:19 | 825641662 | MB : module de base - | BARBOTIN Ludwig (TM) | ||||||||
| YSM3 | Y06 | 05/12/2024 00:00:00 | 05/12/2024 16:31:00 | 05/12/2024 16:59:00 | 9AFR74968594 | Service Client - Defaut technique |
M. Anthony MENAGER (TM)
(+) |
||||||||
| YSM3 | Y02 | 03/12/2024 16:46:36 | 03/12/2024 17:32:39 | 03/12/2024 18:28:18 | 9AFR74963932 | TS ,TS Personne bloquée / CLIENT NE M'ENTTEND PAS BIEN - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Systeme de commande - Carte electronique | Urgence Sécurité | Mis en sécurité |
JOYEUX Guillaume (TM)
(+) |
||
| YSM1 | Y03 | 11/10/2024 00:00:00 | 30/10/2024 09:02:00 | 30/10/2024 09:17:21 | 820686426 | MB : module de base - | BARBOTIN Ludwig (TM) | ||||||||
| YSM1 | Y04 | 20/07/2023 00:00:00 | 10/07/2024 09:18:00 | 03/10/2024 08:55:00 | 792588828 | REMP.LAMPE : JANZE CCPA MC 2000 KG | Joyeux Guillaume (TM) | ||||||||
| YSM1 | Y04 | 20/07/2023 00:00:00 | 03/10/2024 08:27:00 | 03/10/2024 08:55:00 | 792994072 | Commande - Commande JEU 3 CLES,3319 PRIC LINK V2 FO | Joyeux Guillaume (TM) | ||||||||
| YSM1 | Y04 | 11/10/2023 00:00:00 | 17/10/2023 19:00:00 | 03/10/2024 08:55:00 | 798568873 | livraison materiel | Joyeux Guillaume (TM) | ||||||||
| YSM1 | Y04 | 05/09/2024 00:00:00 | 06/09/2024 13:58:00 | 06/09/2024 13:59:00 | 821258418 | relevé poids sur arbre | Bouyault Gwendal (TS THD) | ||||||||
| YSM1 | Y03 | 16/08/2024 00:00:00 | 26/08/2024 15:26:00 | 26/08/2024 15:37:32 | 817188688 | MB : module de base - | Joyeux Guillaume (TM) | ||||||||
| YSM3 | Y01 | 26/08/2024 10:28:14 | 26/08/2024 13:36:42 | 26/08/2024 15:21:38 | 9AFR74767995 | MR NOEL ,Ascenseur à l'étage porte ouverte//ASC BLQ AU 5°//URGENT BLOQUE LA PRODUCTION DU SITE - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Régler | Porte et huisserie - Porte cabine - Rail de suspente, panneaux, seuil - Navette | Haute priorité | Remis en service |
JOYEUX Guillaume (TM)
(+) |
||
| YSM6 | Y04 | 19/07/2024 00:00:00 | 16/07/2024 08:30:00 | 16/07/2024 12:30:00 | 324470146 | Rplt roulement palier moteur - ROULEMENT PALIER CCPA 35 JANZE | M. Gwendal BOUYAULT (TS THD) | ||||||||
| YSM3 | Y01 | 20/06/2024 12:58:35 | 20/06/2024 13:50:06 | 16/07/2024 10:03:59 | 9AFR74646613 | MR LECHEVALIER ,Ascenseur à l'étage porte ouverteAU RDC ET FAIT LEGEREMENT LA NAVETTE ENTRE LE RDC ET 1ER - | Indisponible - Arrêté au niveau - Porte fermée | Aucun defaut constate | Vérifier | Porte et huisserie - Porte palière (auto) - Rail de suspente, panneaux, seuil - Composants de synchronisation | Haute priorité | Remis en service |
BARBOTIN Ludwig (TM)
(+) |
||
| YSM1 | Y03 | 01/07/2024 00:00:00 | 10/07/2024 16:36:43 | 10/07/2024 17:19:00 | 815675349 | LC : Legal complementaire - MC LC | Mace Pascal (RE) | ||||||||
| YSM1 | Y03 | 01/07/2024 00:00:00 | 10/07/2024 16:36:43 | 10/07/2024 17:19:00 | 815675349 | MC : module complet - MC LC | Mace Pascal (RE) | ||||||||
| YSM1 | Y03 | 01/01/2024 00:00:00 | 10/07/2024 14:38:02 | 10/07/2024 16:35:38 | 803055774 | EG : équipement gaine - PC PP EG TR MA SI | Mace Pascal (RE) | ||||||||
| YSM1 | Y03 | 01/01/2024 00:00:00 | 10/07/2024 14:38:02 | 10/07/2024 16:35:38 | 803055774 | MA : manoeuvre - PC PP EG TR MA SI | Mace Pascal (RE) | ||||||||
| YSM1 | Y03 | 01/01/2024 00:00:00 | 10/07/2024 14:38:02 | 10/07/2024 16:35:38 | 803055774 | PC : opérateur porte cabine - PC PP EG TR MA SI | Mace Pascal (RE) | ||||||||
| YSM1 | Y03 | 01/01/2024 00:00:00 | 10/07/2024 14:38:02 | 10/07/2024 16:35:38 | 803055774 | PP : portes palières - PC PP EG TR MA SI | Mace Pascal (RE) | ||||||||
| YSM1 | Y03 | 01/01/2024 00:00:00 | 10/07/2024 14:38:02 | 10/07/2024 16:35:38 | 803055774 | SI : signalisation - PC PP EG TR MA SI | Mace Pascal (RE) | ||||||||
| YSM1 | Y03 | 01/01/2024 00:00:00 | 10/07/2024 14:38:02 | 10/07/2024 16:35:38 | 803055774 | TR : treuil ou machine - PC PP EG TR MA SI | Mace Pascal (RE) | ||||||||
| YSM1 | Y03 | 28/06/2024 00:00:00 | 02/07/2024 12:30:54 | 02/07/2024 12:46:07 | 813527426 | MB : module de base - | M. Gwendal BOUYAULT (TS THD) | ||||||||
| YSM3 | Y01 | 02/07/2024 09:30:30 | 02/07/2024 10:34:31 | 02/07/2024 12:30:54 | 9AFR74669479 | MR ANDOUARD ,Ascenseur bloqué entre étages//ENTRE RDC ET 1ER//CABLETTE CASSEE - | Indisponible - Arrêté au niveau - Porte fermée | Composant use (remplacement preventif) | Remplacer | Porte et huisserie - Porte palière (auto) - Rail de suspente, panneaux, seuil - Composants de synchronisation | Haute priorité | Remis en service |
BOUYAULT Gwendal (TS THD)
(+) |
||
| YSM1 | Y04 | 23/05/2024 00:00:00 | 23/05/2024 08:42:00 | 12/06/2024 09:52:00 | 813760520 | Réglage porte | Bouyault Gwendal (TS THD) | ||||||||
| YSM3 | Y01 | 06/06/2024 09:39:17 | 06/06/2024 11:02:45 | 06/06/2024 12:31:05 | 9AFR74619381 | M LECHEVALLIER ,Panne au RDC/ 3 fois ce matin et 2x personnes bloquées/ descend plus bas que le niveau/ se présenter à l'accueil - | Disponible - Vibre au fonctionnement | Defaut technique | Vérifier | Cabine - Electrification | Haute priorité | Remis en service |
MACE Pascal (RE)
(+) |
||
| YSM1 | Y03 | 26/04/2024 00:00:00 | 14/05/2024 10:06:29 | 14/05/2024 10:22:01 | 809213176 | MB : module de base - | Bouyault Gwendal (TS THD) | ||||||||
| YSM1 | Y03 | 15/03/2024 00:00:00 | 12/03/2024 08:45:41 | 12/03/2024 09:16:27 | 806513288 | MB : module de base - | BARBOTIN Ludwig (TM) | ||||||||
| YSM1 | Y03 | 26/01/2024 00:00:00 | 31/01/2024 10:22:45 | 31/01/2024 12:07:11 | 802969229 | MB : module de base - | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y04 | 21/04/2023 00:00:00 | 15/12/2023 13:15:00 | 15/12/2023 17:07:00 | 787207238 | - COMMANDE PATIN DE PORTE,SANS INSERT ECOS | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y03 | 15/12/2023 00:00:00 | 13/12/2023 14:09:23 | 13/12/2023 15:07:09 | 800394503 | MB : module de base - | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y04 | 23/11/2023 00:00:00 | 05/12/2023 16:39:00 | 05/12/2023 16:41:00 | 801381182 | COMMANDE SUIVANT DEVIS SOCOM | Mace Pascal (RE) | ||||||||
| YSM1 | Y03 | 03/11/2023 00:00:00 | 02/11/2023 10:26:10 | 02/11/2023 10:43:45 | 797553342 | MB : module de base - | Marcel Frédéric (TM) | ||||||||
| YSM6 | Y04 | 23/10/2023 00:00:00 | 27/10/2023 13:40:00 | 27/10/2023 16:40:00 | 323992917 | Rplt porte palière complète - PORTE PALIERE CCPA 35 JANZE | Bouyault Gwendal (TS THD) | ||||||||
| YSM3 | Y01 | 03/10/2023 08:52:33 | 03/10/2023 10:31:00 | 03/10/2023 12:49:38 |
9AFR74145078
Repet. |
MR ANDOIR ,Ascenseur retombé en panne / BLOQ FERM - | Indisponible - Arrêté entre étage - Porte palière fermée | Vetuste | Vérifier | Porte et huisserie - Porte palière (auto) - Porte palière | Haute priorité | Remis en service |
MARCEL Frédéric (TM)
(+) |
||
| YSM3 | Y01 | 28/09/2023 18:18:22 | 29/09/2023 08:37:01 | 29/09/2023 10:20:23 |
9AFR74137899
Repet. |
MR ANDOUARD ,Ascenseur à l'étage porte fermée / 4EME / PB RECCURENT / - | Disponible - Dysfonctionnement autre | Defaut technique | Vérifier | Système de commande - Système de commande | Haute priorité | Remis en service |
BARBOTIN Ludwig (TM)
(+) |
||
| YSM3 | Y01 | 27/09/2023 09:44:06 | 27/09/2023 10:29:21 | 27/09/2023 15:13:11 | 9AFR74134148 | M NOEL ,Ascenseur à l'étage porte fermée ENTRE 2 ET 3 E // URGENT - | Indisponible - Arrêté entre étage - Porte palière fermée | Defaut technique | Vérifier | Porte et huisserie - Porte palière (auto) - Porte palière | Haute priorité | Remis en service |
MARCEL Frédéric (TM)
(+) |
||
| YSM1 | Y03 | 01/01/2023 00:00:00 | 22/09/2023 10:14:00 | 22/09/2023 10:35:00 | 777274438 | EG : équipement gaine - PC PP EG TR MA SI | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y03 | 01/01/2023 00:00:00 | 22/09/2023 10:14:00 | 22/09/2023 10:35:00 | 777274438 | MA : manoeuvre - PC PP EG TR MA SI | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y03 | 01/01/2023 00:00:00 | 22/09/2023 10:14:00 | 22/09/2023 10:35:00 | 777274438 | PC : opérateur porte cabine - PC PP EG TR MA SI | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y03 | 01/01/2023 00:00:00 | 22/09/2023 10:14:00 | 22/09/2023 10:35:00 | 777274438 | PP : portes palières - PC PP EG TR MA SI | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y03 | 01/01/2023 00:00:00 | 22/09/2023 10:14:00 | 22/09/2023 10:35:00 | 777274438 | SI : signalisation - PC PP EG TR MA SI | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y03 | 01/01/2023 00:00:00 | 22/09/2023 10:14:00 | 22/09/2023 10:35:00 | 777274438 | TR : treuil ou machine - PC PP EG TR MA SI | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y03 | 22/09/2023 00:00:00 | 22/09/2023 09:52:38 | 22/09/2023 10:13:33 | 794638862 | MB : module de base - | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y03 | 11/08/2023 00:00:00 | 09/08/2023 13:49:32 | 09/08/2023 14:12:58 | 792027417 | MB : module de base - | BARBOTIN Ludwig (TM) | ||||||||
| YSM1 | Y03 | 01/07/2023 00:00:00 | 30/06/2023 14:14:59 | 30/06/2023 15:40:25 | 791043858 | LC : Legal complementaire - MC LC | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y03 | 01/07/2023 00:00:00 | 30/06/2023 14:14:59 | 30/06/2023 15:40:25 | 791043858 | MC : module complet - MC LC | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y03 | 30/06/2023 00:00:00 | 30/06/2023 13:59:30 | 30/06/2023 14:14:59 | 789339765 | MB : module de base - | Marcel Frédéric (TM) | ||||||||
| YSM3 | Y04 | 17/05/2023 08:41:50 | 17/05/2023 08:58:19 | 17/05/2023 10:00:07 | 9AFR73883235 | Travail non prévu effectué pendant l'opération de maintenance n° 787448120 - | Aucun defaut constate | Vérifier | Porte et huisserie - Porte cabine - Contact de porte | Remis en service |
BARBOTIN Ludwig (TM)
(+) |
||||
| YSM1 | Y03 | 19/05/2023 00:00:00 | 17/05/2023 08:42:50 | 17/05/2023 08:58:19 | 787448120 | MB : module de base - | BARBOTIN Ludwig (TM) | ||||||||
| YSM3 | Y01 | 16/05/2023 14:03:28 | 16/05/2023 16:05:26 | 16/05/2023 18:05:36 | 9AFR73881733 | MR ANDOIR ,Ascenseur à l'étage porte ouverte // PORTE NAVETTE AU 3EME ETG - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Régler | Porte et huisserie - Porte paliere (auto) - Cadre et linteaux | Haute priorité | Remis en service |
BOUYAULT Gwendal (TS THD)
(+) |
||
| YSM1 | Y03 | 21/04/2023 00:00:00 | 21/04/2023 08:46:37 | 21/04/2023 09:12:20 | 783830296 | MB : module de base - | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y03 | 03/03/2023 00:00:00 | 10/03/2023 09:02:23 | 10/03/2023 09:33:07 | 779322574 | MB : module de base - | Marcel Frédéric (TM) | ||||||||
| YSM3 | Y01 | 13/02/2023 09:21:59 | 13/02/2023 13:15:06 | 13/02/2023 15:07:26 | 9AFR73718791 | MR LECHEVALIER ,Ascenseur à l'étage porte ouverte AU RDC - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Porte et huisserie - Porte palière (auto) - Porte palière | Haute priorité | Remis en service |
MARCEL Frédéric (TM)
(+) |
||
| YSM3 | Y01 | 03/02/2023 10:04:10 | 03/02/2023 10:20:46 | 03/02/2023 11:27:59 | 9AFR73701970 | MR LECHEVALLIER ,Marche superieure à 15 cm 3 ETG / FONCTIONNE - | Disponible - Dysfonctionnement autre | Defaut technique | Vérifier | Equipement gaine - Electrification gaine - Sélection gaine | Urgence Sécurité | Remis en service |
MARCEL Frédéric (TM)
(+) |
||
| YSM1 | Y03 | 13/01/2023 00:00:00 | 16/01/2023 15:57:24 | 16/01/2023 16:39:34 | 776150402 | MB : module de base - | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y03 | 25/11/2022 00:00:00 | 30/11/2022 15:53:02 | 30/11/2022 16:22:46 | 772592594 | MB : module de base - | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y03 | 01/07/2022 00:00:00 | 12/10/2022 16:32:18 | 12/10/2022 16:50:00 | 762478867 | LC : Legal complementaire - MC LC | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y03 | 01/07/2022 00:00:00 | 12/10/2022 16:32:18 | 12/10/2022 16:50:00 | 762478867 | MC : module complet - MC LC | Marcel Frédéric (TM) | ||||||||
| YSM3 | Y04 | 03/08/2022 14:59:50 | 12/10/2022 16:24:00 | 12/10/2022 16:25:00 | 9AFR73355294 | MR MAUSSION ,Service Client - MR MAUSSION souhaite faire le point sur la télésurveillance lors de la MB - merci de le contacter - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Système périphérique - Telesurveillance | Basse priorité | Remis en service |
MARCEL Frédéric (TM)
(+) |
||
| YSM3 | Y09 | SN_URGENT | 03/08/2022 14:08:56 | 12/10/2022 16:23:00 | 12/10/2022 16:24:00 | 9AFR73355117 | SN000223 - Défaut d'appel cyclique: AMPHITECH, le système ne fait pas d'appel cyclique | Remis en service |
MARCEL Frédéric (TM)
(+) |
||||||
| YSM1 | Y03 | 14/10/2022 00:00:00 | 12/10/2022 16:12:59 | 12/10/2022 16:22:00 | 769410820 | MB : module de base - | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y04 | 01/07/2022 00:00:00 | 02/09/2022 10:16:00 | 02/09/2022 11:12:00 | 763463355 | Campagne TS GSM - Campagne TS GSM - Reprogrammation | Bouyault Gwendal (TS THD) | ||||||||
| YSM1 | Y03 | 02/09/2022 00:00:00 | 02/09/2022 10:01:12 | 02/09/2022 10:16:53 | 765419272 | MB : module de base - | Bouyault Gwendal (TS THD) | ||||||||
| YSM1 | Y03 | 22/07/2022 00:00:00 | 21/07/2022 15:27:54 | 21/07/2022 15:44:17 | 761802045 | MB : module de base - | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y03 | 03/06/2022 00:00:00 | 10/06/2022 08:05:30 | 10/06/2022 08:36:52 | 758329216 | MB : module de base - | Marcel Frédéric (TM) | ||||||||
| YSM1 | Y03 | 15/04/2022 00:00:00 | 22/04/2022 14:04:19 | 22/04/2022 14:26:00 | 754852461 | MB : module de base - | Mouhadji Hamada () | ||||||||
| YSM1 | Y03 | 04/03/2022 00:00:00 | 04/03/2022 09:48:25 | 04/03/2022 10:13:54 | 751710656 | MB : module de base - | Mouhadji Hamada () | ||||||||
| YSM3 | Y02 | 24/01/2022 07:10:57 | 24/01/2022 07:40:13 | 24/01/2022 08:21:14 | 9AFR73006055 | M GARCIA ,TS 1 Personne bloquée ENTRE LE RDC ET LE 1ER ETAGE - | Indisponible - Arrêté entre étage - Porte palière fermée | Defaut technique | Vérifier | Porte et huisserie - Porte cabine - Contact de porte | Urgence Sécurité | Remis en service |
MOUHADJI Hamada ()
(+) |
||
| YSM3 | Y04 | 21/01/2022 10:12:03 | 21/01/2022 10:31:18 | 21/01/2022 11:01:48 | 9AFR73003211 | MOUHADJI Hamada ,Travail non prévu effectué pendant l'opération de maintenance n° 748463062 , ExWk - | Defaut technique | Vérifier | Système périphérique - Eclairage de secours - Batterie de secours | Remis en service |
MOUHADJI Hamada ()
(+) |
||||
| YSM1 | Y03 | 21/01/2022 00:00:00 | 21/01/2022 10:13:03 | 21/01/2022 10:31:18 | 748463062 | MB : module de base - | Mouhadji Hamada () | ||||||||
| YSM3 | Y09 | SN_URGENT | 07/01/2022 12:31:59 | 08/01/2022 14:15:22 | 08/01/2022 14:16:00 | 9AFR72977508 | SN000223 - Défaut d'appel cyclique: AMPHITECH le système ne fait pas d'appel cyclique | Remis en service |
BOUYAULT Gwendal (TS THD)
(+) |
||||||
| YSM3 | Y01 | 31/12/2021 08:50:36 | 31/12/2021 09:03:00 | 31/12/2021 10:20:44 | 9AFR72963752 | M.SEBASTIEN ,Ascenseur à l'étage porte fermée - | Indisponible - Arrêté au niveau - Porte fermée | Composant use (remplacement preventif) | Remplacer | Porte et huisserie - Porte paliere (auto) - Contact de porte | Haute priorité | Remis en service |
MOUHADJI Hamada ()
(+) |
||
| YSM3 | Y04 | 08/12/2021 14:52:05 | 08/12/2021 15:11:36 | 08/12/2021 16:12:15 | 9AFR72921899 | MOUHADJI Hamada ,Travail non prévu effectué pendant l'opération de maintenance n° 744696061 , ExWk - | Defaut technique | Régler | Porte et huisserie - Porte cabine - Porte cabine | Remis en service |
MOUHADJI Hamada ()
(+) |
||||
| YSM1 | Y03 | 03/12/2021 00:00:00 | 08/12/2021 14:53:05 | 08/12/2021 15:11:36 | 744696061 | MB : module de base - | Mouhadji Hamada () | ||||||||
| YSM3 | Y04 | 21/10/2021 15:10:00 | 21/10/2021 15:10:00 | 21/10/2021 17:32:21 | 9AFR72809370 | BOUYAULT Gwendal ,Service Client , 121 - | Disponible - Dysfonctionnement autre | Defaut technique | Régler | Porte et huisserie - Porte palière (auto) - Porte palière | Remis en service |
BOUYAULT Gwendal (TS THD)
(+) |
|||
| YSM1 | Y04 | 09/10/2021 00:00:00 | 18/10/2021 14:19:00 | 18/10/2021 15:20:00 | 744206912 | FUSIBLES 3.15A CONDITIONNEMENT DE 10 | Mouhadji Hamada () | ||||||||
| YSM1 | Y03 | 22/10/2021 00:00:00 | 18/10/2021 14:08:24 | 18/10/2021 14:19:09 | 742411868 | MB : module de base - | Mouhadji Hamada () | ||||||||
| YSM1 | Y03 | 01/01/2021 00:00:00 | 18/10/2021 13:52:25 | 18/10/2021 14:08:24 | 724173440 | MA : manoeuvre - PC PP EG TR MA SI | Mouhadji Hamada () | ||||||||
| YSM1 | Y03 | 01/01/2021 00:00:00 | 18/10/2021 13:52:25 | 18/10/2021 14:08:24 | 724173440 | PC : opérateur porte cabine - PC PP EG TR MA SI | Mouhadji Hamada () | ||||||||
| YSM1 | Y03 | 01/07/2021 00:00:00 | 18/10/2021 13:18:50 | 18/10/2021 13:52:25 | 736409012 | LC : Legal complementaire - MC LC | Mouhadji Hamada () | ||||||||
| YSM1 | Y03 | 01/07/2021 00:00:00 | 18/10/2021 13:18:50 | 18/10/2021 13:52:25 | 736409012 | MC : module complet - MC LC | Mouhadji Hamada () | ||||||||
| YSM3 | Y04 | 18/10/2021 11:00:33 | 18/10/2021 11:20:40 | 18/10/2021 13:18:50 | 9AFR72800596 | MOUHADJI Hamada ,Défaut porte paliere , 102 - | Disponible - Dysfonctionnement autre | Utilisation anormale | Régler | Porte et huisserie - Porte palière (auto) - Rail de suspente, panneaux, seuil - Rail de suspente | Remis en service |
MOUHADJI Hamada ()
(+) |
|||
| YSM3 | Y01 | 07/09/2021 09:17:28 | 07/09/2021 11:00:14 | 07/09/2021 12:18:23 | 9AFR72717043 | MR ANDOUARD ,Ascenseur à l'étage porte fermée RDC SE PRESENTER A L ACCEUIL ADMINISTRATIF POUR RENTRER - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Régler | Porte et huisserie - Porte palière (auto) - Porte palière | Haute priorité | Remis en service |
BOUYAULT Gwendal (TS THD)
(+) |
||
| YSM1 | Y03 | 10/09/2021 00:00:00 | 07/09/2021 12:03:00 | 07/09/2021 12:18:00 | 739714703 | MB : module de base - | Bouyault Gwendal (TS THD) | ||||||||
| YSM1 | Y04 | 05/07/2021 00:00:00 | 29/07/2021 12:11:00 | 29/07/2021 12:25:00 | 736338446 | REMPL SHUNT + CONTACT PORTE SLYCMA ECOSI | Mouhadji Hamada () | ||||||||
| YSM3 | Y04 | 29/07/2021 11:14:39 | 29/07/2021 11:35:49 | 29/07/2021 12:11:24 | 9AFR72650953 | MOUHADJI Hamada ,Travail non prévu effectué pendant l'opération de maintenance n° 735900417 , ExWk - | Defaut technique | Régler | Porte et huisserie - Porte cabine - Sécurité porte cabine - Cellule photo électrique | Remis en service |
MOUHADJI Hamada ()
(+) |
||||
| YSM1 | Y03 | 23/07/2021 00:00:00 | 29/07/2021 11:15:39 | 29/07/2021 11:35:49 | 735900417 | MB : module de base - | Mouhadji Hamada () | ||||||||
| YSM3 | Y01 | 20/07/2021 16:07:03 | 20/07/2021 17:01:47 | 20/07/2021 18:36:50 | 9AFR72634073 | M LECHEVALLIER ,Ascenseur à l'étage porte fermée 4EME PERS DEBLOQUEE PAR TM DU SITE - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Remplacer | Machinerie - Autres composants machinerie | Haute priorité | Remis en service |
MOUHADJI Hamada ()
(+) |
||
| YSM1 | Y04 | 21/06/2021 00:00:00 | 25/06/2021 10:07:00 | 25/06/2021 12:31:00 | 736370632 | - SHUNT + CONTACT PORTE SLYCMA ECOSIL | Mouhadji Hamada () | ||||||||
| YSM3 | Y04 | 25/06/2021 10:22:08 | 25/06/2021 11:48:44 | 25/06/2021 12:30:38 | 9AFR72586975 | MOUHADJI Hamada ,Travail non prévu effectué pendant l'opération de maintenance n° 724173440 , ExWk - | Aucun defaut constate | Nettoyer - Machinerie | Machinerie - Autres composants machinerie | Remis en service |
MOUHADJI Hamada ()
(+) |
||||
| YSM1 | Y03 | 01/01/2021 00:00:00 | 25/06/2021 10:23:08 | 25/06/2021 11:48:44 | 724173440 | EG : équipement gaine - PC PP EG TR MA SI | Mouhadji Hamada () | ||||||||
| YSM1 | Y03 | 01/01/2021 00:00:00 | 25/06/2021 10:23:08 | 25/06/2021 11:48:44 | 724173440 | PP : portes palières - PC PP EG TR MA SI | Mouhadji Hamada () | ||||||||
| YSM1 | Y03 | 01/01/2021 00:00:00 | 25/06/2021 10:23:08 | 25/06/2021 11:48:44 | 724173440 | SI : signalisation - PC PP EG TR MA SI | Mouhadji Hamada () | ||||||||
| YSM1 | Y03 | 01/01/2021 00:00:00 | 25/06/2021 10:23:08 | 25/06/2021 11:48:44 | 724173440 | TR : treuil ou machine - PC PP EG TR MA SI | Mouhadji Hamada () | ||||||||
| YSM1 | Y03 | 04/06/2021 00:00:00 | 10/06/2021 11:56:17 | 10/06/2021 12:11:01 | 732692311 | MB : module de base - | M. Gwendal BOUYAULT (TS THD) | ||||||||
| YSM3 | Y01 | 10/06/2021 08:57:47 | 10/06/2021 10:58:50 | 10/06/2021 11:56:17 | 9AFR72551256 | MR LECHEVALIER ,Panne 3°+ BIP EN CONTINU - | Indisponible - Arrêté au niveau - Porte fermée | Composant use (remplacement preventif) | Remplacer | Porte et huisserie - Porte paliere (auto) - Contact de porte | Haute priorité | Remis en service |
BOUYAULT Gwendal (TS THD)
(+) |
||
| YSM1 | Y04 | 03/04/2021 00:00:00 | 22/04/2021 12:16:00 | 22/04/2021 12:21:00 | 731394324 | Commande SHUNT + CONTACT PORTE SLYCMA EC | Mouhadji Hamada () | ||||||||
| YSM3 | Y04 | 22/04/2021 10:10:39 | 22/04/2021 10:31:06 | 22/04/2021 12:16:58 | 9AFR72461924 | MOUHADJI Hamada ,Travail non prévu effectué pendant l'opération de maintenance n° 729731583 , ExWk - | Defaut technique | Régler | Porte et huisserie - Porte cabine - Rail de suspente, panneaux, seuil - Seuil | Remis en service |
MOUHADJI Hamada ()
(+) |
||||
| YSM1 | Y03 | 23/04/2021 00:00:00 | 22/04/2021 10:11:39 | 22/04/2021 10:31:06 | 729731583 | MB : module de base - | Mouhadji Hamada () | ||||||||
| YSM3 | Y01 | 02/04/2021 15:48:32 | 02/04/2021 16:34:42 | 02/04/2021 19:01:46 | 9AFR72427817 | MR ANDOUARD ,Ascenseur à l'étage porte fermée 3ET - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Régler | Porte et huisserie - Porte paliere (battante) - Contact de porte | Haute priorité | Remis en service |
MOUHADJI Hamada ()
(+) |
||
| YSM1 | Y04 | 03/07/2020 00:00:00 | 19/03/2021 09:52:00 | 19/03/2021 10:06:00 | 713800138 | reparation carte electronique | Mouhadji Hamada () | ||||||||
| YSM3 | Y04 | 19/03/2021 08:09:04 | 19/03/2021 08:32:56 | 19/03/2021 09:52:39 | 9AFR72398808 | MOUHADJI Hamada ,Service Client , 121 - | Disponible - Bruit au fonctionnement | Defaut technique | Régler | Porte et huisserie - Porte paliere (auto) - Cadre et linteaux | Remis en service |
MOUHADJI Hamada ()
(+) |
|||
| YSM3 | Y04 | 12/03/2021 11:19:47 | 12/03/2021 11:40:29 | 12/03/2021 12:41:37 | 9AFR72387435 | MOUHADJI Hamada ,Travail non prévu effectué pendant l'opération de maintenance n° 726655694 , ExWk - | Defaut technique | Remplacer | Contrepoids - Coulisseaux - Coulisseaux | Remis en service |
MOUHADJI Hamada ()
(+) |
||||
| YSM1 | Y03 | 12/03/2021 00:00:00 | 12/03/2021 11:20:47 | 12/03/2021 11:40:29 | 726655694 | MB : module de base - | Mouhadji Hamada () | ||||||||
| YSM1 | Y03 | 08/01/2021 00:00:00 | 25/01/2021 11:25:24 | 25/01/2021 11:39:31 | 722851996 | MB : module de base - | Mouhadji Hamada () | ||||||||
Pour des raisons de performances, l'affichage est restreint dans le temps (5 ans).
Si vous recherchez des ordres de services antérieurs, alors la totalité des OS est disponible via
--> e.Carnet