Liste des Ordres de Service de l'équipement 43732155
Liste des Ordres de Service
74 ordres de services trouvés
| Type | Act. | sensemble | Date Planif/Appel | Date arrivée | Date Départ | OS | Cas THD | Description | constat | Défaut | Action | Composant | Type appel | Condition au départ | Dernier Technicien | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YSM1 | Y03 | 20/02/2026 00:00:00 | 17/02/2026 10:33:58 | 17/02/2026 10:57:45 | 869384670 | MB : module de base - | Deubras Romuald (TM) | |||||||||
| YSM1 | Y03 | 09/01/2026 00:00:00 | 08/01/2026 10:58:29 | 08/01/2026 11:19:53 | 865966721 | MB : module de base - | Deubras Romuald (TM) | |||||||||
| YSM1 | Y03 | 01/11/2025 00:00:00 | 13/12/2025 09:57:06 | 13/12/2025 10:27:37 | 854402600 | EG : équipement gaine - PC PP EG TR MA SI | Bollaert Cedric () | |||||||||
| YSM1 | Y03 | 01/11/2025 00:00:00 | 13/12/2025 09:57:06 | 13/12/2025 10:27:37 | 854402600 | MA : manoeuvre - PC PP EG TR MA SI | Bollaert Cedric () | |||||||||
| YSM1 | Y03 | 01/11/2025 00:00:00 | 13/12/2025 09:57:06 | 13/12/2025 10:27:37 | 854402600 | PC : opérateur porte cabine - PC PP EG TR MA SI | Bollaert Cedric () | |||||||||
| YSM1 | Y03 | 01/11/2025 00:00:00 | 13/12/2025 09:57:06 | 13/12/2025 10:27:37 | 854402600 | PP : portes palières - PC PP EG TR MA SI | Bollaert Cedric () | |||||||||
| YSM1 | Y03 | 01/11/2025 00:00:00 | 13/12/2025 09:57:06 | 13/12/2025 10:27:37 | 854402600 | SI : signalisation - PC PP EG TR MA SI | Bollaert Cedric () | |||||||||
| YSM1 | Y03 | 01/11/2025 00:00:00 | 13/12/2025 09:57:06 | 13/12/2025 10:27:37 | 854402600 | TR : treuil ou machine - PC PP EG TR MA SI | Bollaert Cedric () | |||||||||
| YSM6 | Y04 | 24/11/2025 00:00:00 | 05/12/2025 13:53:31 | 05/12/2025 15:18:17 | 325204770 | MODULE GSM 4G POUR KCE - GSM - VIROFLAY - 133/135 AV DU GEN LECLE | Chabila Abdelhadi (RE) | |||||||||
| YSM6 | Y04 | 05/12/2025 00:00:00 | 03/12/2025 13:26:00 | 03/12/2025 16:52:33 | 325207217 | RIDEAU CELLULES,STATIQUE SLIMSCREEN AMD - REMP RIDEAU CELLULE- PICKERING REAL ESTA | Chabila Abdelhadi (RE) | |||||||||
| YSM1 | Y03 | 28/11/2025 00:00:00 | 25/11/2025 14:15:03 | 25/11/2025 14:30:06 | 863223618 | MB : module de base - | DELMAS Simon (TM) | |||||||||
| YSM1 | Y03 | 17/10/2025 00:00:00 | 16/10/2025 12:43:04 | 16/10/2025 12:54:11 | 859867259 | MB : module de base - | DELMAS Simon (TM) | |||||||||
| YSM1 | Y03 | 05/09/2025 00:00:00 | 01/09/2025 08:18:46 | 01/09/2025 08:30:43 | 857481715 | MB : module de base - | DELMAS Simon (TM) | |||||||||
| YSM3 | Y01 | 21/07/2025 17:16:52 | 21/07/2025 17:53:44 | 27/07/2025 10:28:50 | 9AFR75389138 | MME BOVIN ,Sécurité // CELLULE + CONTACT CHOC HS - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Porte et huisserie - Porte cabine - Sécurité porte cabine - Rideau de cellule | Urgence Sécurité | Remis en service |
LEGENDRE Dan (TM)
(+) |
|||
| YSM1 | Y03 | 25/07/2025 00:00:00 | 26/07/2025 10:13:44 | 26/07/2025 10:15:46 | 853950174 | MB : module de base - | M. Romuald DEUBRAS (TM) | |||||||||
| YSM3 | Y01 | 13/07/2025 12:58:07 | 13/07/2025 16:13:03 | 13/07/2025 17:03:01 | 9AFR75377058 | MME KRAUT ,Ascenseur à l'étage porte ouverte RDC - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Vérifier | Porte et huisserie - Porte cabine - Sécurité porte cabine - Cellule photo électrique | Haute priorité | Remis en service |
BERDAOUCH Soufiane (TM)
(+) |
|||
| YSM3 | Y01 | 23/06/2025 14:24:18 | 24/06/2025 11:53:22 | 24/06/2025 11:58:37 | 9AFR75337123 | MME KRAUT ,Défaut porte//PORTE QUI BLOQUE AU RDC // USAGER RESTE BLOQUER - | Disponible - Dysfonctionnement autre | Utilisation anormale | Nettoyer - Autres composants | Porte et huisserie - Porte cabine - Sécurité porte cabine - Rideau de cellule | Haute priorité | Remis en service |
LEGENDRE Dan (TM)
(+) |
|||
| YSM1 | Y03 | 13/06/2025 00:00:00 | 13/06/2025 14:28:28 | 13/06/2025 14:44:58 | 850696864 | MB : module de base - | Legendre Dan (TM) | |||||||||
| YSM3 | Y09 | SN_URGENT | 10/04/2025 14:16:20 | 03/05/2025 17:07:02 | 03/05/2025 18:11:19 | 9AFR75204298 | SN000224 - Défaut d'appel cyclique: KCE, le système ne fait pas d'appel cyclique | Remis en service |
LEGENDRE Dan (TM)
(+) |
|||||||
| YSM1 | Y03 | 25/04/2025 00:00:00 | 28/04/2025 09:33:12 | 28/04/2025 10:16:35 | 846912531 | MB : module de base - | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 01/05/2025 00:00:00 | 28/04/2025 08:36:43 | 28/04/2025 09:33:12 | 829067731 | LC : Legal complementaire - MC LC | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 01/05/2025 00:00:00 | 28/04/2025 08:36:43 | 28/04/2025 09:33:12 | 829067731 | MC : module complet - MC LC | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 14/03/2025 00:00:00 | 11/03/2025 16:37:18 | 11/03/2025 16:47:46 | 832138504 | MB : module de base - | M. Cedric BOLLAERT (TM) | |||||||||
| YSM1 | Y03 | 31/01/2025 00:00:00 | 28/01/2025 17:10:35 | 28/01/2025 17:24:03 | 828612066 | MB : module de base - | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 27/12/2024 00:00:00 | 17/12/2024 11:18:42 | 17/12/2024 11:51:31 | 826193957 | MB : module de base - | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 08/11/2024 00:00:00 | 13/11/2024 09:57:25 | 13/11/2024 10:04:21 | 822847060 | MB : module de base - | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 01/11/2024 00:00:00 | 24/09/2024 15:17:38 | 24/09/2024 15:45:39 | 816038234 | EG : équipement gaine - PC PP EG TR MA SI | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 01/11/2024 00:00:00 | 24/09/2024 15:17:38 | 24/09/2024 15:45:39 | 816038234 | MA : manoeuvre - PC PP EG TR MA SI | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 01/11/2024 00:00:00 | 24/09/2024 15:17:38 | 24/09/2024 15:45:39 | 816038234 | PC : opérateur porte cabine - PC PP EG TR MA SI | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 01/11/2024 00:00:00 | 24/09/2024 15:17:38 | 24/09/2024 15:45:39 | 816038234 | PP : portes palières - PC PP EG TR MA SI | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 01/11/2024 00:00:00 | 24/09/2024 15:17:38 | 24/09/2024 15:45:39 | 816038234 | SI : signalisation - PC PP EG TR MA SI | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 01/11/2024 00:00:00 | 24/09/2024 15:17:38 | 24/09/2024 15:45:39 | 816038234 | TR : treuil ou machine - PC PP EG TR MA SI | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 04/10/2024 00:00:00 | 24/09/2024 14:25:43 | 24/09/2024 15:00:19 | 820250721 | MB : module de base - | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 09/08/2024 00:00:00 | 19/08/2024 11:37:56 | 19/08/2024 11:48:51 | 816988020 | MB : module de base - | Samy Pierre (TM) | |||||||||
| YSM3 | Y01 | 08/08/2024 15:18:46 | 09/08/2024 10:21:09 | 09/08/2024 11:10:44 |
9AFR74740182
Repet. |
ME BOVIN ,Panne /ASC BLQ /135 B/URGENT - | Disponible - Dysfonctionnement autre | Defaut technique | Régler | Machinerie - Autres composants machinerie | Haute priorité | Remis en service |
BEKHOUCH Abdelhakim (TM)
(+) |
|||
| YSM3 | Y01 | 07/08/2024 16:47:21 | 08/08/2024 14:14:48 | 08/08/2024 14:58:28 |
9AFR74738368
Repet. |
ME BOVIN ,Ascenseur à l'étage porte fermée - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Porte et huisserie - Porte cabine - Porte cabine | Haute priorité | Remis en service |
BEKHOUCH Abdelhakim (TM)
(+) |
|||
| YSM3 | Y01 | 02/08/2024 17:54:54 | 03/08/2024 10:25:02 | 03/08/2024 12:21:55 | 9AFR74730423 | M PARMENTIER ,Ascenseur RDC porte fermée sens interdit sur l'affichage - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Régler | Cabine - Electrification | Haute priorité | Remis en service |
SAMY Pierre (TM)
(+) |
|||
| YSM1 | Y03 | 05/07/2024 00:00:00 | 27/06/2024 09:53:22 | 27/06/2024 10:02:34 | 814295941 | MB : module de base - | Samy Pierre (TM) | |||||||||
| YSM3 | Y01 | 26/06/2024 17:38:44 | 27/06/2024 08:35:55 | 27/06/2024 09:53:22 | 9AFR74659059 | MR GASNOT ,Panne / HS AU 3E - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Régler | Porte et huisserie - Porte cabine - Contact de porte | Haute priorité | Remis en service |
SAMY Pierre (TM)
(+) |
|||
| YSM1 | Y03 | 05/04/2024 00:00:00 | 23/05/2024 11:07:55 | 23/05/2024 11:20:56 | 808204104 | MB : module de base - | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 01/05/2024 00:00:00 | 23/05/2024 10:33:45 | 23/05/2024 10:53:30 | 803426895 | LC : Legal complementaire - MC LC | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 01/05/2024 00:00:00 | 23/05/2024 10:33:45 | 23/05/2024 10:53:30 | 803426895 | MC : module complet - MC LC | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 23/02/2024 00:00:00 | 22/02/2024 10:49:47 | 22/02/2024 11:00:05 | 804713964 | MB : module de base - | Bollaert Cedric (TM) | |||||||||
| YSM3 | Y01 | 14/01/2024 08:53:51 | 14/01/2024 12:10:34 | 14/01/2024 13:52:11 | 9AFR74356904 | MR GASNOT ,Ascenseur à l'étage porte ouverte AU 1ER - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Système de commande - Système de commande | Haute priorité | Remis en service |
SAINT PAUL Éric (TM)
(+) |
|||
| YSM1 | Y03 | 12/01/2024 00:00:00 | 09/01/2024 15:49:55 | 09/01/2024 16:02:03 | 801978365 | MB : module de base - | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y03 | 01/12/2023 00:00:00 | 28/11/2023 16:30:22 | 28/11/2023 16:48:35 | 799064906 | MB : module de base - | M. Cedric BOLLAERT (TM) | |||||||||
| YSM1 | Y03 | 01/11/2023 00:00:00 | 16/10/2023 17:07:48 | 16/10/2023 17:38:19 | 791430921 | EG : équipement gaine - PC PP EG TR MA SI | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y03 | 01/11/2023 00:00:00 | 16/10/2023 17:07:48 | 16/10/2023 17:38:19 | 791430921 | MA : manoeuvre - PC PP EG TR MA SI | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y03 | 01/11/2023 00:00:00 | 16/10/2023 17:07:48 | 16/10/2023 17:38:19 | 791430921 | PC : opérateur porte cabine - PC PP EG TR MA SI | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y03 | 01/11/2023 00:00:00 | 16/10/2023 17:07:48 | 16/10/2023 17:38:19 | 791430921 | PP : portes palières - PC PP EG TR MA SI | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y03 | 01/11/2023 00:00:00 | 16/10/2023 17:07:48 | 16/10/2023 17:38:19 | 791430921 | SI : signalisation - PC PP EG TR MA SI | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y03 | 01/11/2023 00:00:00 | 16/10/2023 17:07:48 | 16/10/2023 17:38:19 | 791430921 | TR : treuil ou machine - PC PP EG TR MA SI | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y03 | 20/10/2023 00:00:00 | 16/10/2023 15:45:48 | 16/10/2023 15:59:10 | 796295807 | MB : module de base - | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y04 | 06/09/2023 00:00:00 | 21/09/2023 15:44:00 | 21/09/2023 15:45:00 | 796218903 | CARTE SIM VODAPHONE GLOBAL KRM | M. Cedric BOLLAERT (TM) | |||||||||
| YSM3 | Y09 | SN_URGENT | 16/08/2023 11:19:26 | 05/09/2023 10:37:10 | 21/09/2023 15:44:32 | 9AFR74054275 | SN000224 - Défaut d'appel cyclique: KCE, le système ne fait pas d'appel cyclique | Remis en service |
BOLLAERT Cedric (TM)
(+) |
|||||||
| YSM1 | Y03 | 01/09/2023 00:00:00 | 05/09/2023 11:12:39 | 05/09/2023 11:24:32 | 792974229 | MB : module de base - | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y03 | 21/07/2023 00:00:00 | 19/07/2023 08:28:55 | 19/07/2023 08:39:36 | 790067736 | MB : module de base - | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y03 | 09/06/2023 00:00:00 | 06/06/2023 10:37:20 | 06/06/2023 10:48:49 | 788378679 | MB : module de base - | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y03 | 01/05/2023 00:00:00 | 27/04/2023 14:14:30 | 27/04/2023 14:46:49 | 777668784 | LC : Legal complementaire - MC LC | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 01/05/2023 00:00:00 | 27/04/2023 14:14:30 | 27/04/2023 14:46:49 | 777668784 | MC : module complet - MC LC | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 28/04/2023 00:00:00 | 27/04/2023 08:42:48 | 27/04/2023 08:56:25 | 784050972 | MB : module de base - | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 17/03/2023 00:00:00 | 13/03/2023 10:25:34 | 13/03/2023 10:40:39 | 781168531 | MB : module de base - | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y03 | 03/02/2023 00:00:00 | 02/02/2023 09:02:00 | 02/02/2023 09:13:16 | 778056294 | MB : module de base - | Bollaert Cedric (TM) | |||||||||
| YSM3 | Y09 | SN_URGENT | 13/01/2023 14:54:42 | 17/01/2023 10:17:37 | 17/01/2023 10:31:59 | 9AFR73661099 | SN000201 - Le KC210 a perdu la communication avec le contrôleur | Remis en service |
BOLLAERT Cedric (TM)
(+) |
|
||||||
| YSM1 | Y04 | KCO_1ST_INST | 23/06/2022 00:00:00 | 06/01/2023 15:33:00 | 06/01/2023 16:50:00 | 759541333 | FYCOR : 1ere visite Monospace | Bollaert Cedric (TM) | ||||||||
| YSM3 | Y09 | SN_URGENT | 06/01/2023 14:24:56 | 06/01/2023 14:54:15 | 06/01/2023 15:33:16 | 9AFR73647988 | SN000201 - Le KC210 a perdu la communication avec le contrôleur | Remis en service |
BOLLAERT Cedric (TM)
(+) |
|
||||||
| YSM3 | Y09 | SN_URGENT | 27/12/2022 15:17:50 | 28/12/2022 14:56:16 | 28/12/2022 15:07:08 | 9AFR73630229 | SN000201 - Le KC210 a perdu la communication avec le contrôleur | Remis en service |
BOLLAERT Cedric (TM)
(+) |
|
||||||
| YSM3 | Y04 | 15/11/2022 15:22:03 | 23/12/2022 08:49:30 | 23/12/2022 09:19:49 | 9AFR73544236 | MR BEKOUR ,Baisser son de la synthèse vocale + sirène - | Disponible - Bruit au fonctionnement | Aucun defaut constate | Vérifier | Signalisation - Palière - Synthése vocale | Basse priorité | Remis en service |
BOLLAERT Cedric (TM)
(+) |
|||
| YSM1 | Y03 | 23/12/2022 00:00:00 | 23/12/2022 08:35:32 | 23/12/2022 08:49:30 | 774732074 | MB : module de base - | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y04 | KCO_24_7_ACT | 14/09/2022 00:00:00 | 09/12/2022 11:19:00 | 09/12/2022 13:31:00 | 769969524 | KONE 24/7 activation | Labrana Kevin (TS THD) | ||||||||
| YSM1 | Y03 | 01/11/2022 00:00:00 | 10/11/2022 16:03:08 | 10/11/2022 16:33:17 | 762762353 | EG : équipement gaine - PC PP EG TR MA SI | M. Cedric BOLLAERT (TM) | |||||||||
| YSM1 | Y03 | 01/11/2022 00:00:00 | 10/11/2022 16:03:08 | 10/11/2022 16:33:17 | 762762353 | MA : manoeuvre - PC PP EG TR MA SI | M. Cedric BOLLAERT (TM) | |||||||||
| YSM1 | Y03 | 01/11/2022 00:00:00 | 10/11/2022 16:03:08 | 10/11/2022 16:33:17 | 762762353 | PC : opérateur porte cabine - PC PP EG TR MA SI | M. Cedric BOLLAERT (TM) | |||||||||
| YSM1 | Y03 | 01/11/2022 00:00:00 | 10/11/2022 16:03:08 | 10/11/2022 16:33:17 | 762762353 | PP : portes palières - PC PP EG TR MA SI | M. Cedric BOLLAERT (TM) | |||||||||
| YSM1 | Y03 | 01/11/2022 00:00:00 | 10/11/2022 16:03:08 | 10/11/2022 16:33:17 | 762762353 | SI : signalisation - PC PP EG TR MA SI | M. Cedric BOLLAERT (TM) | |||||||||
| YSM1 | Y03 | 01/11/2022 00:00:00 | 10/11/2022 16:03:08 | 10/11/2022 16:33:17 | 762762353 | TR : treuil ou machine - PC PP EG TR MA SI | M. Cedric BOLLAERT (TM) | |||||||||
| YSM1 | Y03 | 28/10/2022 00:00:00 | 10/11/2022 15:44:00 | 10/11/2022 15:52:50 | 770013733 | MB : module de base - | M. Cedric BOLLAERT (TM) | |||||||||
| YSM1 | Y03 | 02/09/2022 00:00:00 | 14/09/2022 15:49:29 | 14/09/2022 15:59:41 | 764968711 | MB : module de base - | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y03 | 22/07/2022 00:00:00 | 20/07/2022 16:16:07 | 20/07/2022 16:26:16 | 761556599 | MB : module de base - | M. Cedric BOLLAERT (TM) | |||||||||
| YSM1 | Y03 | 10/06/2022 00:00:00 | 07/06/2022 17:46:08 | 07/06/2022 18:05:25 | 758984355 | MB : module de base - | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y03 | 01/05/2022 00:00:00 | 11/05/2022 15:09:34 | 11/05/2022 15:28:53 | 749645812 | LC : Legal complementaire - MC LC | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y03 | 01/05/2022 00:00:00 | 11/05/2022 15:09:34 | 11/05/2022 15:28:53 | 749645812 | MC : module complet - MC LC | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y03 | 29/04/2022 00:00:00 | 28/04/2022 11:07:19 | 28/04/2022 11:09:03 | 755387248 | MB : module de base - | Bollaert Cedric (TM) | |||||||||
| YSM3 | Y09 | SN_URGENT | 14/04/2022 15:03:12 | 14/04/2022 15:38:56 | 28/04/2022 11:07:19 | 9AFR73152245 | SN000224 - Défaut d'appel cyclique: KCE, le système ne fait pas d'appel cyclique | Mis en sécurité |
BOLLAERT Cedric (TM)
(+) |
|||||||
| YSM3 | Y01 | FR_SEB_CTU | 28/03/2022 11:45:15 | 28/03/2022 14:08:13 | 28/03/2022 16:57:44 | 9AFR73118330 | MME LIBRATI ,Ascenseur à l'étage porte fermée // LIVRAISON PREVU CET APRES-MIDI - | Indisponible - Arrêté au niveau - Porte fermée | Causes exterieures - Disjoncteur declenche | Vérifier | Systeme de commande - Cablage | Haute priorité | Remis en service |
BOLLAERT Cedric (TM)
(+) |
||
| YSM3 | Y01 | FR_SEB_CTU | 15/03/2022 12:09:27 | 17/03/2022 16:05:22 | 17/03/2022 17:04:41 | 9AFR73095809 | MME LIBRATI ,Ascenseur à l'étage porte fermée - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Porte et huisserie - Porte palière (auto) - Porte palière | Haute priorité | Remis en service |
BOLLAERT Cedric (TM)
(+) |
||
| YSM1 | Y03 | 18/03/2022 00:00:00 | 14/03/2022 15:25:52 | 14/03/2022 15:36:04 | 752962280 | MB : module de base - | Bollaert Cedric (TM) | |||||||||
| YSM1 | Y04 | 15/02/2022 00:00:00 | 25/02/2022 09:07:00 | 25/02/2022 10:31:00 | 753229511 | CARTE KCEFCB-EU, PROGRAMMES KCE | Bollaert Cedric (TM) | |||||||||
| YSM6 | Y04 | 01/02/2022 00:00:00 | 21/02/2022 13:02:13 | 21/02/2022 17:02:47 | 323351010 | CABLETTE LIMITEUR KIT REMP COMPLET L=80M - inondation vandalisme OGIC, 135 AVENUE D | Boedec Serge (TM) | |||||||||
| YSM6 | Y04 | 01/02/2022 00:00:00 | 21/02/2022 13:02:13 | 21/02/2022 17:02:47 | 323351010 | Colonne palière - inondation vandalisme OGIC, 135 AVENUE D | Boedec Serge (TM) | |||||||||
| YSM3 | Y01 | FR_SEB_CTU | 21/02/2022 16:02:15 | 21/02/2022 16:23:45 | 21/02/2022 16:34:40 | 9AFR73057982 | MME LIBRATI ,1 Personne bloquée ENTRE LE 1ER ET LE 2EME ETG - | Indisponible - Arrêté entre étage - Porte palière fermée | Causes exterieures - Disjoncteur declenche | Vérifier | Porte et huisserie - Porte palière (auto) - Porte palière | Urgence Sécurité | Remis en service |
SAMY Pierre (TM)
(+) |
||
| YSM6 | Y04 | 01/02/2022 00:00:00 | 11/02/2022 08:51:47 | 11/02/2022 13:34:56 | 323351010 | Eclairage gaine - inondation vandalisme OGIC, 135 AVENUE D | Boedec Serge (TM) | |||||||||
| YSM6 | Y04 | 01/02/2022 00:00:00 | 11/02/2022 08:51:47 | 11/02/2022 13:34:56 | 323351010 | Poulie Tendeuse cuvette - inondation vandalisme OGIC, 135 AVENUE D | Boedec Serge (TM) | |||||||||
| YSM3 | Y01 | FR_SEB_CTU | 19/01/2022 10:45:26 | 19/01/2022 13:57:29 | 11/02/2022 10:29:18 | 9AFR72998917 | ME LIBRATI ,ARRET TM / Ascenseur inondé 0666388980 - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Equipement gaine - Limiteur de vitesse - Poulie tendeuse | Urgence Sécurité | Mis en sécurité |
BOLLAERT Cedric (TM)
(+) |
||
| YSM6 | Y04 | 01/02/2022 00:00:00 | 10/02/2022 17:27:59 | 10/02/2022 17:43:55 | 323351010 | Pompage et décorodage - inondation vandalisme OGIC, 135 AVENUE D | Boedec Serge (TM) | |||||||||
| YSM1 | Y03 | 28/01/2022 00:00:00 | 04/02/2022 16:25:49 | 04/02/2022 16:41:02 | 748605335 | MB : module de base - | Bollaert Cedric (TM) | |||||||||
| YSM3 | Y01 | FR_SEB_CTU | 07/01/2022 14:07:50 | 09/01/2022 10:26:03 | 10/01/2022 15:32:05 | 9AFR72977819 | ME LIBRATI ,BLOQUE -2 SS PRECISION / INFO TM ouvrier on bloquer les porte volontairement pour que personne ne puisse acceder au chantier - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Porte et huisserie - Porte cabine - Contact de porte | Haute priorité | Remis en service |
SAMY Pierre (TM)
(+) |
||
| YSM1 | Y03 | 01/11/2021 00:00:00 | 14/12/2021 14:47:53 | 14/12/2021 15:03:05 | 745094163 | EG : équipement gaine - PC PP EG TR MA SI | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 01/11/2021 00:00:00 | 14/12/2021 14:47:53 | 14/12/2021 15:03:05 | 745094163 | MA : manoeuvre - PC PP EG TR MA SI | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 01/11/2021 00:00:00 | 14/12/2021 14:47:53 | 14/12/2021 15:03:05 | 745094163 | PC : opérateur porte cabine - PC PP EG TR MA SI | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 01/11/2021 00:00:00 | 14/12/2021 14:47:53 | 14/12/2021 15:03:05 | 745094163 | PP : portes palières - PC PP EG TR MA SI | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 01/11/2021 00:00:00 | 14/12/2021 14:47:53 | 14/12/2021 15:03:05 | 745094163 | SI : signalisation - PC PP EG TR MA SI | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 01/11/2021 00:00:00 | 14/12/2021 14:47:53 | 14/12/2021 15:03:05 | 745094163 | TR : treuil ou machine - PC PP EG TR MA SI | Samy Pierre (TM) | |||||||||
| YSM1 | Y03 | 24/12/2021 00:00:00 | 14/12/2021 14:27:19 | 14/12/2021 14:35:03 | 746333147 | MB : module de base - | Samy Pierre (TM) | |||||||||
| YSM3 | Y02 | FR_SEB_CTU | 18/11/2021 14:25:39 | 18/11/2021 14:46:56 | 18/11/2021 14:47:16 | 9AFR72879579 | TS ,TS Personne bloquée - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Remise a zero (reset) | Systeme de commande - Carte electronique | Urgence Sécurité | Remis en service |
SAMY Pierre (TM)
(+) |
||
| YSM1 | Y03 | 01/11/2021 00:00:00 | 08/11/2021 12:36:34 | 08/11/2021 12:48:50 | 744451864 | MB : module de base - | Samy Pierre (TM) | |||||||||
| AS1 : Installation neuve réalisée le 09/05/2022 (Pt 5 du S-plan). Réseau 71343255 | ||||||||||||||||
| YSM3 | Y04 | FR_SEB_CTU | 19/10/2021 16:40:44 | 27/10/2021 09:56:47 | 04/11/2021 10:54:50 | 9AFR72804385 | ME LIBRATI ,Ascenseur Bruyant AU NIVEAU DU SOUS SOL EN DESCENTE ET SURSAUT EN REMONTANT AU RDC - | Disponible - Bruit au fonctionnement | Defaut technique | Régler | Porte et huisserie - Porte cabine - Sécurité porte cabine - Cellule photo électrique | Haute priorité | Remis en service |
SAMY Pierre (TM)
(+) |
||
Pour des raisons de performances, l'affichage est restreint dans le temps (5 ans).
Si vous recherchez des ordres de services antérieurs, alors la totalité des OS est disponible via
--> e.Carnet