Liste des Ordres de Service de l'équipement 10575735
Liste des Ordres de Service
123 ordres de services trouvés
| Type | Act. | sensemble | Date Planif/Appel | Date arrivée | Date Départ | OS | Cas THD | Description | constat | Défaut | Action | Composant | Type appel | Condition au départ | Dernier Technicien |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YSM1 | Y03 | 01/04/2026 00:00:00 | 05/03/2026 13:59:52 | 05/03/2026 14:38:13 | 867860921 | LC : Legal complementaire - MC LC | Vauzou Florent (TM) | ||||||||
| YSM1 | Y03 | 01/04/2026 00:00:00 | 05/03/2026 13:59:52 | 05/03/2026 14:38:13 | 867860921 | MC : module complet - MC LC | Vauzou Florent (TM) | ||||||||
| YSM1 | Y03 | 06/03/2026 00:00:00 | 05/03/2026 13:47:26 | 05/03/2026 13:59:52 | 870598086 | MB : module de base - | Vauzou Florent (TM) | ||||||||
| YSM6 | Y04 | 05/02/2026 00:00:00 | 09/02/2026 10:21:00 | 09/02/2026 11:20:49 | 325302204 | SPOT LED SPL,6W 230V H.40 D.56 IP64 - ECLAIRAGE CABINE - BRIVE HABITAT - 19 B | M. Eric VERNHES () | ||||||||
| YSM1 | Y03 | 23/01/2026 00:00:00 | 21/01/2026 10:49:24 | 21/01/2026 11:00:34 | 867125152 | MB : module de base - | Vauzou Florent (TM) | ||||||||
| YSM3 | Y01 | 09/01/2026 11:22:09 | 09/01/2026 13:33:26 | 09/01/2026 14:12:52 | 9AFR75667063 | - MR LYOUBI ,Eclairage cabine HS// ET PORTE CAB SOUVRE DIFFICILEMENT RDC - | Disponible - Dysfonctionnement autre | Defaut technique | Vérifier | Système de commande - Autres composants électriques - Disjoncteur | Urgence Sécurité | Remis en service |
()
(+) |
||
| YSM3 | Y01 | 04/01/2026 15:37:14 | 04/01/2026 16:59:20 | 04/01/2026 17:15:45 | 9AFR75655874 | - ME LALLEMAND ,Ascenseur à l'étage porte fermée/ PROBLEME DE FERMETURE DES PORTES AU RDC - | Disponible - Dysfonctionnement autre | Vetuste | Régler | Porte et huisserie - Porte palière (battante) - Porte palière (battante) | Haute priorité | Remis en service |
VAUZOU Florent (TM)
(+) |
||
| YSM1 | Y03 | 01/04/2025 00:00:00 | 10/12/2025 14:42:00 | 10/12/2025 15:09:44 | 828924376 | LC : Legal complementaire - MC LC | Barougier Jean Christophe (TS THD) | ||||||||
| YSM1 | Y03 | 01/04/2025 00:00:00 | 10/12/2025 14:42:00 | 10/12/2025 15:09:44 | 828924376 | MC : module complet - MC LC | Barougier Jean Christophe (TS THD) | ||||||||
| YSM1 | Y03 | 12/12/2025 00:00:00 | 10/12/2025 14:30:17 | 10/12/2025 14:42:00 | 863934061 | MB : module de base - | Barougier Jean Christophe (TS THD) | ||||||||
| YSM1 | Y03 | 31/10/2025 00:00:00 | 27/10/2025 10:03:40 | 27/10/2025 10:07:54 | 860586055 | MB : module de base - | Barougier Jean Christophe (TS THD) | ||||||||
| YSM3 | Y01 | 27/10/2025 06:56:14 | 27/10/2025 09:24:39 | 27/10/2025 10:03:40 | 9AFR75541762 | MME OUKHALLEF ,Ascenseur Bruyant UGT RESONNE DANS LE BAT - | Disponible - Bruit au fonctionnement | Defaut technique | Graisser/Lubrifier | Guides et fixations - Guides cabine | Haute priorité | Remis en service |
BAROUGIER Jean Christophe (TS THD)
(+) |
||
| YSM3 | Y01 | 21/10/2025 16:29:41 | 21/10/2025 17:50:00 | 21/10/2025 18:25:09 | 9AFR75533705 | MME NELMONT ,Ascenseur à l'étage porte fermée // RDC - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Régler | Porte et huisserie - Porte paliere (battante) - Mecanisme de porte | Urgence Sécurité | Remis en service |
JUBERTIE Philippe (TM)
(+) |
||
| YSM3 | Y01 | 08/10/2025 10:13:26 | 08/10/2025 13:43:05 | 08/10/2025 13:56:02 | 9AFR75511798 | MME OUKHALLES ,Ascenseur Bruyant / ALARME SONNE EN CONTINUE / S'ENTEND DANS LES LOGEMENTS - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Régler | Porte et huisserie - Porte paliere (battante) - Serrure | Haute priorité | Remis en service |
VAUZOU Florent (TM)
(+) |
||
| YSM6 | Y04 | 08/09/2025 00:00:00 | 26/09/2025 10:59:00 | 26/09/2025 12:32:38 | 325077027 | REMPL SER ASCINTER - REMPLACEMENT SERRURE - BRIVE HABITAT - 1 | M. Francois Xavier VERNAY (TM) | ||||||||
| YSM1 | Y03 | 26/09/2025 00:00:00 | 16/09/2025 15:41:22 | 16/09/2025 15:56:36 | 858571531 | MB : module de base - | Barougier Jean Christophe (TS THD) | ||||||||
| YSM6 | Y04 | 08/09/2025 00:00:00 | 12/09/2025 09:00:00 | 12/09/2025 10:17:00 | 325076957 | REMPL SER ASCINTER - ARRET - SERRURE - BRIVE HABITAT - 19 BRI | M. Francois Xavier VERNAY (TM) | ||||||||
| YSM3 | Y01 | 01/09/2025 14:21:01 | 01/09/2025 15:13:06 | 01/09/2025 16:03:23 | 9AFR75449231 | MME MATAZIN ,Ascenseur à l'étage porte fermée 2 ETAGES - | Disponible - Dysfonctionnement autre | Vetuste | Vérifier | Porte et huisserie - Porte paliere (battante) - Serrure | Haute priorité | Mis en sécurité |
VAUZOU Florent (TM)
(+) |
||
| YSM3 | Y01 | 25/08/2025 10:45:56 | 25/08/2025 11:31:14 | 25/08/2025 14:37:34 | 9AFR75437930 | MR BOUMRAH ,Ascenseur à l'étage porte fermée - | Disponible - Dysfonctionnement autre | Defaut technique | Vérifier | Porte et huisserie - Porte paliere (battante) - Serrure | Haute priorité | Remis en service |
VAUZOU Florent (TM)
(+) |
||
| YSM1 | Y03 | 15/08/2025 00:00:00 | 14/08/2025 16:05:56 | 14/08/2025 16:21:12 | 855205964 | MB : module de base - | Barougier Jean Christophe (TS THD) | ||||||||
| YSM3 | Y02 | 28/07/2025 19:36:52 | 28/07/2025 19:42:56 | 29/07/2025 09:27:05 | 9AFR75399638 | TS ,ASC ARRETER PAR POMPIER SUITE TS 2 Personne bloquée ENFANT 7 ANS - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Porte et huisserie - Porte paliere (battante) - Serrure | Urgence Sécurité | Remis en service |
SOULISSE Victor (TM)
(+) |
||
| YSM1 | Y03 | 04/07/2025 00:00:00 | 01/07/2025 16:56:13 | 01/07/2025 17:17:58 | 852581936 | MB : module de base - | Vauzou Florent (TM) | ||||||||
| YSM1 | Y03 | 23/05/2025 00:00:00 | 22/05/2025 11:02:53 | 22/05/2025 11:12:14 | 848911662 | MB : module de base - | Vauzou Florent (TM) | ||||||||
| YSM1 | Y03 | 11/04/2025 00:00:00 | 08/04/2025 15:06:36 | 08/04/2025 15:14:31 | 846413055 | MB : module de base - | Vauzou Florent (TM) | ||||||||
| YSM1 | Y03 | 07/03/2025 00:00:00 | 28/02/2025 14:28:29 | 28/02/2025 14:41:09 | 831296421 | MB : module de base - | Vauzou Florent (TM) | ||||||||
| YSM3 | Y01 | 28/02/2025 12:13:33 | 28/02/2025 13:41:27 | 28/02/2025 14:28:29 | 9AFR75129113 | MME LALLEMAND ,Ascenseur à l'étage porte fermée/ RECURRENT - | Indisponible - Arrêté au niveau - Porte fermée | Utilisation anormale | Régler | Porte et huisserie - Porte paliere (battante) - Cadre et linteaux | Haute priorité | Remis en service |
VAUZOU Florent (TM)
(+) |
||
| YSM3 | Y01 | 16/02/2025 10:49:31 | 16/02/2025 14:08:43 | 16/02/2025 15:10:22 | 9AFR75106146 | ME LALLEMAND ,Ascenseur à l'étage porte fermée/PMR 5 ETG - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Systeme de commande - Module de commande | Haute priorité | Remis en service |
BAROUGIER Jean Christophe (TS THD)
(+) |
||
| YSM3 | Y01 | 06/02/2025 18:26:26 | 06/02/2025 18:55:02 | 07/02/2025 11:12:45 | 9AFR75089475 | MME PATRICIA LALLEMAND ,Ascenseur à l'étage porte fermée RDC - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Etrier cabine - Coulisseaux | Haute priorité | Remis en service |
VAUZOU Florent (TM)
(+) |
||
| YSM6 | Y04 | 05/02/2025 00:00:00 | 06/02/2025 09:34:55 | 06/02/2025 10:53:16 | 324755944 | GARNITURE CESTIDUR - ARR // Garniture coulisseau tête de cabi | Mr Jean Christophe BAROUGIER (TS THD) | ||||||||
| YSM3 | Y01 | 21/01/2025 09:25:07 | 21/01/2025 11:05:35 | 21/01/2025 12:01:11 | 9AFR75055235 | MR LIOUBI ,Ascenseur Bruyant/GENE LES LOCATAIRES - | Disponible - Bruit au fonctionnement | Vetuste | Vérifier | Etrier cabine - Coulisseaux | Haute priorité | Mis en sécurité |
VAUZOU Florent (TM)
(+) |
||
| YSM1 | Y03 | 24/01/2025 00:00:00 | 20/01/2025 16:43:37 | 20/01/2025 16:55:32 | 828498180 | MB : module de base - | Vauzou Florent (TM) | ||||||||
| YSM1 | Y04 | 07/01/2025 00:00:00 | 08/01/2025 13:37:00 | 08/01/2025 14:59:00 | 830260254 | REMPL.FERME PORTE LEVASS PH90 CORP F4 G/ | Lasnier Jean Francois (TM) | ||||||||
| YSM3 | Y01 | 04/01/2025 16:26:08 | 04/01/2025 17:02:42 | 06/01/2025 08:00:00 | 9AFR75022178 | MME LALLEMAND ,Panne - | Disponible - Dysfonctionnement autre | Defaut technique | Vérifier | Porte et huisserie - Porte palière (battante) - Ferme porte - Ferme porte | Haute priorité | Remis en service |
BAROUGIER Jean Christophe (TS THD)
(+) |
||
| YSM1 | Y03 | 20/12/2024 00:00:00 | 11/12/2024 16:17:19 | 11/12/2024 16:32:16 | 825709653 | MB : module de base - | Bonneval Frédéric (TS) | ||||||||
| YSM3 | Y01 | 15/11/2024 12:34:24 | 15/11/2024 16:12:00 | 15/11/2024 16:23:13 | 9AFR74925695 | MME NAIMA ,Ascenseur Bruyant / EN DES ET EN MONTER DEPUIS 2 JOURS DERANGE CLT LA NUIT URGT - | Disponible - Bruit au fonctionnement | Defaut technique | Graisser/Lubrifier | Guides et fixations - Guides cabine | Haute priorité | Remis en service |
JUBERTIE Philippe (TM)
(+) |
||
| YSM1 | Y03 | 08/11/2024 00:00:00 | 04/11/2024 16:01:51 | 04/11/2024 16:15:33 | 823276565 | MB : module de base - | Barougier Jean Christophe (TS THD) | ||||||||
| YSM3 | Y01 | 10/10/2024 12:30:19 | 10/10/2024 14:30:00 | 10/10/2024 15:03:04 | 9AFR74858111 | MME PATRICIA ,Ascenseur à l'étage porte ouvertes au RDC - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Porte et huisserie - Porte palière (battante) - Ferme porte - Ferme porte | Haute priorité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM1 | Y03 | 01/10/2024 00:00:00 | 01/10/2024 13:31:21 | 01/10/2024 14:23:25 | 815813094 | PC : opérateur porte cabine - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/10/2024 00:00:00 | 01/10/2024 13:31:21 | 01/10/2024 14:23:25 | 815813094 | EG : équipement gaine - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/10/2024 00:00:00 | 01/10/2024 13:31:21 | 01/10/2024 14:23:25 | 815813094 | PP : portes palières - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/10/2024 00:00:00 | 01/10/2024 13:31:21 | 01/10/2024 14:23:25 | 815813094 | MA : manoeuvre - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/10/2024 00:00:00 | 01/10/2024 13:31:21 | 01/10/2024 14:23:25 | 815813094 | SI : signalisation - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/10/2024 00:00:00 | 01/10/2024 13:31:21 | 01/10/2024 14:23:25 | 815813094 | TR : treuil ou machine - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 27/09/2024 00:00:00 | 25/09/2024 11:44:18 | 25/09/2024 12:01:23 | 820086517 | MB : module de base - | Bonneval Frédéric (TS) | ||||||||
| YSM3 | Y01 | 25/09/2024 08:15:16 | 25/09/2024 11:10:43 | 25/09/2024 11:44:18 | 9AFR74826438 | MR LOUBY ,Sécurité///LIEN VOCAL ARACHER FIL APARENT - | Disponible - Dysfonctionnement autre | Vandalisme | Remplacer | Système périphérique - Telesurveillance | Urgence Sécurité | Remis en service |
BONNEVAL Frédéric (TS)
(+) |
||
| YSM1 | Y03 | 16/08/2024 00:00:00 | 14/08/2024 10:10:00 | 14/08/2024 10:18:00 | 816902250 | MB : module de base - | Bonneval Frédéric (TS) | ||||||||
| YSM3 | Y01 | 13/08/2024 16:33:53 | 13/08/2024 17:47:48 | 14/08/2024 10:08:32 | 9AFR74748744 | MR BOUMRAH ,ARRET TM / Panne - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Porte et huisserie - Porte cabine - Opérateur de porte cabine - Composant mécanique opérateur | Haute priorité | Remis en service |
BONNEVAL Frédéric (TS)
(+) |
||
| YSM1 | Y03 | 05/07/2024 00:00:00 | 01/07/2024 09:14:44 | 01/07/2024 09:45:53 | 813687971 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM3 | Y01 | 19/06/2024 16:13:54 | 19/06/2024 17:10:21 | 19/06/2024 17:16:30 | 9AFR74644931 | MR LOUBY ,Sécurité / SOL ARRACHE / LES GENS TOMBENT - | Disponible - Dysfonctionnement autre | Vetuste | Vérifier | Cabine - Habillage - Sol | Urgence Sécurité | Remis en service |
BOURDIAL Jean Francois (TM)
(+) |
||
| YSM1 | Y03 | 24/05/2024 00:00:00 | 21/05/2024 13:35:18 | 21/05/2024 14:01:11 | 811227951 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM3 | Y01 | 06/05/2024 15:08:28 | 06/05/2024 16:13:20 | 06/05/2024 16:59:01 | 9AFR74565265 | MR LOUBY ,Défaut UN CACHE NEOM ARRACHE ET UN NEOM A REMPLACER - | Disponible - Dysfonctionnement autre | Defaut technique | Remplacer | Cabine - Habillage - Eclairage | Basse priorité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM1 | Y03 | 05/04/2024 00:00:00 | 10/04/2024 14:33:06 | 10/04/2024 14:41:21 | 807344797 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/04/2024 00:00:00 | 10/04/2024 13:42:04 | 10/04/2024 14:33:06 | 803169359 | LC : Legal complementaire - MC LC | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/04/2024 00:00:00 | 10/04/2024 13:42:04 | 10/04/2024 14:33:06 | 803169359 | MC : module complet - MC LC | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 23/02/2024 00:00:00 | 19/02/2024 15:20:00 | 19/02/2024 15:41:10 | 804638504 | MB : module de base - | Jubertie Philippe (TM) | ||||||||
| YSM3 | Y01 | 10/01/2024 12:32:19 | 10/01/2024 17:14:43 | 10/01/2024 17:34:04 |
9AFR74348962
Repet. |
MME OUKHALLEF ,Ascenseur Bruyant SENTEND DANS LES LOGEMENTS - | Disponible - Bruit au fonctionnement | Defaut technique | Graisser/Lubrifier | Contrepoids - Coulisseaux - Coulisseaux | Haute priorité | Remis en service |
JUBERTIE Philippe (TM)
(+) |
||
| YSM1 | Y03 | 05/01/2024 00:00:00 | 08/01/2024 15:40:44 | 08/01/2024 15:43:48 | 801257860 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM3 | Y01 | 08/01/2024 12:15:09 | 08/01/2024 14:54:48 | 08/01/2024 15:40:44 | 9AFR74341295 | MME OUKALEFF ,Défaut porte // RDC S OUVRE PAS - | Disponible - Dysfonctionnement autre | Defaut technique | Régler | Porte et huisserie - Porte paliere (battante) - Serrure | Haute priorité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM1 | Y03 | 17/11/2023 00:00:00 | 21/11/2023 11:27:32 | 21/11/2023 11:46:17 | 798492474 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/10/2023 00:00:00 | 11/10/2023 08:30:34 | 11/10/2023 09:07:37 | 791124992 | EG : équipement gaine - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/10/2023 00:00:00 | 11/10/2023 08:30:34 | 11/10/2023 09:07:37 | 791124992 | MA : manoeuvre - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/10/2023 00:00:00 | 11/10/2023 08:30:34 | 11/10/2023 09:07:37 | 791124992 | PC : opérateur porte cabine - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/10/2023 00:00:00 | 11/10/2023 08:30:34 | 11/10/2023 09:07:37 | 791124992 | PP : portes palières - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/10/2023 00:00:00 | 11/10/2023 08:30:34 | 11/10/2023 09:07:37 | 791124992 | SI : signalisation - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/10/2023 00:00:00 | 11/10/2023 08:30:34 | 11/10/2023 09:07:37 | 791124992 | TR : treuil ou machine - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 06/10/2023 00:00:00 | 04/10/2023 12:49:01 | 04/10/2023 12:53:22 | 795209120 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM3 | Y01 | 04/10/2023 08:53:02 | 04/10/2023 11:57:12 | 04/10/2023 12:49:01 |
9AFR74147360
Repet. |
MME LAFONT ,Ascenseur à l'étage porte ouverte // BLOQUE 1 ER ETAGE - | Indisponible - Arrêté au niveau - Porte ouverte | Vetuste | Régler | Porte et huisserie - Porte cabine - Opérateur de porte cabine - Composant mécanique opérateur | Haute priorité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM3 | Y01 | 03/10/2023 17:48:26 | 03/10/2023 18:33:06 | 03/10/2023 18:58:43 |
9AFR74146804
Repet. |
MR BOUMRAH ,Ascenseur à l'étage porte ouverte // AU 2 ETG // + LA PLATINE HS - | Disponible - Aucun défaut constaté | Vetuste | Vérifier | Porte et huisserie - Porte paliere (auto) - Contact de porte | Haute priorité | Remis en service |
BAROUGIER Jean Christophe (TS THD)
(+) |
||
| YSM3 | Y01 | 01/10/2023 11:14:43 | 01/10/2023 13:06:00 | 01/10/2023 13:31:00 |
9AFR74141850
Repet. |
MR BOUMRAH ,Ascenseur à l'étage porte fermée 1 ER ETG - | Indisponible - Arrêté entre étage - Porte palière fermée | Defaut technique | Remise a zero (reset) | Systeme de commande - Carte electronique | Haute priorité | Remis en service |
ROUSEYROL Adrien (TM)
(+) |
||
| YSM3 | Y01 | 26/09/2023 12:35:00 | 26/09/2023 16:42:52 | 26/09/2023 17:05:42 |
9AFR74132650
Repet. |
ME RAYMOND ,Ascenseur retombé en panne/2EME - | Disponible - Dysfonctionnement autre | Defaut technique | Graisser/Lubrifier | Porte et huisserie - Porte cabine - Opérateur de porte cabine - Composant mécanique opérateur | Haute priorité | Remis en service |
BOURDIAL Jean Francois (TM)
(+) |
||
| YSM3 | Y01 | 25/09/2023 16:17:22 | 25/09/2023 18:58:20 | 25/09/2023 19:17:18 | 9AFR74130838 | M SEMACHE ,Panne //ASC BLOQUE 2 EME ETAGE - | Disponible - Dysfonctionnement autre | Defaut technique | Graisser/Lubrifier | Porte et huisserie - Porte palière (auto) - Porte palière | Haute priorité | Remis en service |
ROUSEYROL Adrien (TM)
(+) |
||
| YSM1 | Y04 | FR_REPARATION | 24/05/2023 00:00:00 | 21/08/2023 12:55:00 | 21/08/2023 12:56:00 | 789330476 | remplt batteries GSM parc Brive habitat | Lasnier Jean Francois (TM) | |||||||
| YSM1 | Y04 | FR_REPARATION | 26/06/2023 00:00:00 | 21/08/2023 12:34:00 | 21/08/2023 12:56:00 | 791518385 | remplt batteries GSM parc Brive habitat | Lasnier Jean Francois (TM) | |||||||
| YSM1 | Y03 | 11/08/2023 00:00:00 | 21/08/2023 12:16:11 | 21/08/2023 12:34:00 | 792093092 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y07 | 12/06/2023 00:00:00 | 28/06/2023 10:16:00 | 28/06/2023 10:42:02 | 786426509 | RES eclairage cabine - KONE mainteneur(IR310212196) | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y07 | 12/06/2023 00:00:00 | 28/06/2023 10:16:00 | 28/06/2023 10:42:02 | 786426509 | RES eclairage secours cabine - KONE mainteneur(IR310212196) | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y07 | 12/06/2023 00:00:00 | 28/06/2023 10:16:00 | 28/06/2023 10:42:02 | 786426509 | Vérif etat telealarme cabine - KONE mainteneur(IR310212196) | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 09/06/2023 00:00:00 | 28/06/2023 09:59:23 | 28/06/2023 10:16:00 | 787551536 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/04/2023 00:00:00 | 02/05/2023 16:49:28 | 02/05/2023 17:27:51 | 777390808 | LC : Legal complementaire - MC LC | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/04/2023 00:00:00 | 02/05/2023 16:49:28 | 02/05/2023 17:27:51 | 777390808 | MC : module complet - MC LC | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 28/04/2023 00:00:00 | 25/04/2023 16:05:00 | 25/04/2023 16:19:26 | 784579508 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 03/03/2023 00:00:00 | 15/03/2023 08:14:49 | 15/03/2023 08:27:51 | 781057860 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM3 | Y01 | 06/02/2023 10:08:41 | 06/02/2023 12:00:08 | 06/02/2023 12:31:39 | 9AFR73705666 | MR BOUMRAH ,Défaut porte PAL RDC NE S'OUVRE PAS - | Disponible - Dysfonctionnement autre | Defaut technique | Régler | Porte et huisserie - Porte paliere (battante) - Serrure | Haute priorité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM1 | Y03 | 03/02/2023 00:00:00 | 01/02/2023 16:41:01 | 01/02/2023 16:59:43 | 777094403 | MB : module de base - | Jubertie Philippe (TM) | ||||||||
| YSM6 | Y04 | 23/01/2023 00:00:00 | 25/01/2023 10:00:00 | 25/01/2023 12:44:00 | 323759978 | remplacement du limiteur de vitesse - remplacement limiteur | Artaud Pascal () | ||||||||
| YSM3 | Y04 | 18/01/2023 09:08:16 | 18/01/2023 08:30:00 | 18/01/2023 09:50:00 | 9AFR73669160 | Travail non prévu effectué pendant l'opération de maintenance n° 777094403 - | Aucun defaut constate | Vérifier | Etrier cabine - Parachute - Tringlerie / boîte | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||||
| YSM3 | Y01 | 16/01/2023 10:19:35 | 16/01/2023 13:40:26 | 16/01/2023 14:54:20 | 9AFR73663928 | ME RAYMOND ,Ascenseur à l'étage porte fermée // RDC - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Régler | Porte et huisserie - Porte paliere (battante) - Serrure | Haute priorité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM1 | Y04 | KCO_CLINICA | 09/09/2022 00:00:00 | 28/12/2022 10:50:00 | 28/12/2022 12:12:00 | 765896125 | Action Clinica Parc Prioritaire - CLI : Action Clinica Prioritaire | Barougier Jean Christophe (TS THD) | |||||||
| YSM1 | Y03 | 30/12/2022 00:00:00 | 19/12/2022 13:31:00 | 19/12/2022 13:45:09 | 774613806 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM3 | Y04 | 21/11/2022 09:14:58 | 21/11/2022 09:47:20 | 21/11/2022 10:41:18 | 9AFR73553904 | MME OUKHALLES ,Ascenseur Bruyant AU 3E - | Disponible - Bruit au fonctionnement | Defaut technique | Graisser/Lubrifier | Guides et fixations - Guides cabine | Haute priorité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM1 | Y03 | 18/11/2022 00:00:00 | 15/11/2022 10:21:52 | 15/11/2022 10:24:48 | 772158629 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM6 | Y04 | 02/11/2022 00:00:00 | 15/11/2022 08:30:00 | 15/11/2022 10:21:52 | 323666072 | remplacement de la poignée de porte rdc - remplt poignée de porte rdc | Lasnier Jean Francois (TM) | ||||||||
| YSM3 | Y01 | 27/10/2022 15:57:46 | 28/10/2022 09:16:17 | 28/10/2022 09:31:40 | 9AFR73513345 | MR LYOUVI ,Défaut porte // RDC // FONCTIONNE MAL // POIGNEE HS - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Porte et huisserie - Porte palière (battante) - Porte palière (battante) | Haute priorité | Remis en service |
BOURDIAL Jean Francois (TM)
(+) |
||
| YSM1 | Y03 | 01/10/2022 00:00:00 | 06/10/2022 11:31:09 | 06/10/2022 12:04:00 | 762587209 | EG : équipement gaine - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/10/2022 00:00:00 | 06/10/2022 11:31:09 | 06/10/2022 12:04:00 | 762587209 | PC : opérateur porte cabine - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/10/2022 00:00:00 | 06/10/2022 11:31:09 | 06/10/2022 12:04:00 | 762587209 | MA : manoeuvre - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/10/2022 00:00:00 | 06/10/2022 11:31:09 | 06/10/2022 12:04:00 | 762587209 | PP : portes palières - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/10/2022 00:00:00 | 06/10/2022 11:31:09 | 06/10/2022 12:04:00 | 762587209 | TR : treuil ou machine - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/10/2022 00:00:00 | 06/10/2022 11:31:09 | 06/10/2022 12:04:00 | 762587209 | SI : signalisation - PC PP EG TR MA SI | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 21/10/2022 00:00:00 | 05/10/2022 11:44:00 | 05/10/2022 12:26:59 | 769486724 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 02/09/2022 00:00:00 | 06/09/2022 14:01:20 | 06/09/2022 14:15:52 | 765594350 | MB : module de base - | M. Jean Francois LASNIER (TM) | ||||||||
| YSM3 | Y01 | 09/08/2022 15:18:53 | 09/08/2022 17:35:04 | 09/08/2022 17:41:06 | 9AFR73365395 | MR BRUGET ,Panne MANQUE POIGNET PTE PALIER RDC EXT - | Disponible - Dysfonctionnement autre | Causes exterieures - En attente de reparation | Vérifier | Porte et huisserie - Porte palière (battante) - Porte palière (battante) | Haute priorité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM3 | Y02 | 31/07/2022 14:14:06 | 31/07/2022 14:25:13 | 31/07/2022 15:04:24 | 9AFR73348682 | USAGER ,TS Personne bloquée 1 PERSONNE BLQ - | Indisponible - Arrêté entre étage - Porte palière fermée | Defaut technique | Vérifier | Porte et huisserie - Porte paliere (battante) - Contact de porte | Urgence Sécurité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM3 | Y01 | 28/07/2022 11:19:53 | 28/07/2022 15:21:43 | 28/07/2022 15:55:25 | 9AFR73343908 | MR BOUMRAH ,Ascenseur disjoncté - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Régler | Porte et huisserie - Porte paliere (battante) - Serrure | Haute priorité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM3 | Y01 | 27/07/2022 11:01:05 | 27/07/2022 11:47:29 | 27/07/2022 12:31:35 | 9AFR73341758 | ME LAFONT ,Ascenseur à l'étage porte fermée CHARIOT DE MENAGE A L INTERIEUR - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Régler | Porte et huisserie - Porte paliere (battante) - Serrure | Haute priorité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM1 | Y03 | 22/07/2022 00:00:00 | 22/07/2022 08:56:34 | 22/07/2022 09:15:57 | 761866566 | MB : module de base - | Rouseyrol Adrien (TM) | ||||||||
| YSM1 | Y04 | 12/04/2022 00:00:00 | 11/07/2022 16:56:00 | 11/07/2022 16:57:00 | 757373528 | traitement machoires de frein | Artaud Pascal () | ||||||||
| YSM3 | Y01 | 19/06/2022 17:13:15 | 19/06/2022 18:01:56 | 19/06/2022 18:28:36 | 9AFR73268085 | MME.ARRAS ,Ascenseur à l'étage porte fermée / PMR - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Régler | Porte et huisserie - Porte palière (battante) - Ferme porte - Ferme porte | Haute priorité | Remis en service |
BOURDIAL Jean Francois (TM)
(+) |
||
| YSM3 | Y01 | 18/06/2022 14:48:45 | 18/06/2022 17:44:28 | 18/06/2022 18:08:48 | 9AFR73266942 | MR BRUGET ,Panne NE MONTE PAS RESTE STATIQUE PORTES FONCTIONNE - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Porte et huisserie - Porte cabine - Porte cabine | Haute priorité | Remis en service |
BOURDIAL Jean Francois (TM)
(+) |
||
| YSM1 | Y03 | 13/05/2022 00:00:00 | 08/06/2022 08:12:57 | 08/06/2022 08:17:52 | 761002152 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 06/05/2022 00:00:00 | 30/05/2022 10:24:06 | 30/05/2022 10:56:03 | 756436828 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y04 | FR_REPARATION | 31/03/2022 00:00:00 | 04/04/2022 09:37:00 | 04/04/2022 10:34:00 | 756547210 | remplt came mobile | GIBELIN Christophe (RE) | |||||||
| YSM1 | Y04 | FR_REPARATION | 31/03/2022 00:00:00 | 31/03/2022 08:30:00 | 31/03/2022 17:50:00 | 756514933 | équilibrage | GIBELIN Christophe (RE) | |||||||
| YSM3 | Y04 | 01/04/2022 17:26:50 | 31/03/2022 09:02:00 | 31/03/2022 12:30:00 | 9AFR73128818 | LENAIN Francis ,Travail non prévu effectué pendant l'opération de maintenance n° 756436828 , ExWk - | Defaut technique | Régler | Système de traction - Module de traction | Remis en service |
LENAIN Francis (RGL)
(+) |
||||
| YSM6 | Y04 | 15/10/2021 00:00:00 | 31/03/2022 07:58:00 | 31/03/2022 07:59:00 | 323226012 | Package personnalisé - BRIVE LA 2 PAUL GANET COURTELINE remplt | GIBELIN Christophe (RE) | ||||||||
| YSM1 | Y03 | 25/03/2022 00:00:00 | 25/03/2022 08:26:00 | 25/03/2022 08:46:25 | 752867598 | MB : module de base - | M. Jean Francois LASNIER (TM) | ||||||||
| YSM3 | Y01 | 09/02/2022 14:47:55 | 09/02/2022 17:31:05 | 09/02/2022 18:08:43 | 9AFR73037540 | MR BRUGET ,Ascenseur Bruyant GENE LES USAGERS - | Disponible - Bruit au fonctionnement | Defaut technique | Régler | Porte et huisserie - Porte cabine - Opérateur de porte cabine - Composant mécanique opérateur | Haute priorité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM1 | Y03 | 18/02/2022 00:00:00 | 08/02/2022 11:17:00 | 08/02/2022 11:18:00 | 750769748 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/04/2022 00:00:00 | 08/02/2022 10:29:26 | 08/02/2022 11:17:23 | 749267312 | LC : Legal complementaire - MC LC | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/04/2022 00:00:00 | 08/02/2022 10:29:26 | 08/02/2022 11:17:23 | 749267312 | MC : module complet - MC LC | Lasnier Jean Francois (TM) | ||||||||
| YSM6 | Y04 | 02/12/2021 00:00:00 | 02/02/2022 08:23:00 | 02/02/2022 12:03:10 | 323277671 | Remplacement de la porte palière du 6ème - REMPLT PORTE PALIERE 6EME | Jubertie Philippe (TM) | ||||||||
| YSM1 | Y03 | 21/01/2022 00:00:00 | 06/01/2022 15:09:05 | 06/01/2022 15:26:31 | 748507634 | MB : module de base - | M. Jean Francois LASNIER (TM) | ||||||||
| YSM1 | Y03 | 24/12/2021 00:00:00 | 10/12/2021 09:08:22 | 10/12/2021 09:40:07 | 746251512 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM3 | Y01 | 17/11/2021 10:09:38 | 17/11/2021 10:16:07 | 17/11/2021 11:59:30 | 9AFR72876057 | MR YOUBY ,Ascenseur à l'étage porte fermée - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Régler | Porte et huisserie - Porte palière (battante) - Panneaux et seuil - Panneaux | Haute priorité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM3 | Y01 | 13/11/2021 11:31:07 | 13/11/2021 13:40:54 | 15/11/2021 11:22:13 | 9AFR72851888 | MR BRUVET ,Ascenseur à l'étage porte ouverte 6E - | Indisponible - Arrêté au niveau - Porte fermée | Causes exterieures - En attente de reparation | Régler | Porte et huisserie - Porte palière (auto) - Ferme porte (contrepoids,ressort) | Haute priorité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM1 | Y03 | 03/12/2021 00:00:00 | 09/11/2021 17:25:13 | 09/11/2021 17:42:20 | 744749098 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM3 | Y04 | 03/11/2021 12:07:10 | 03/11/2021 14:00:26 | 03/11/2021 14:22:59 | 9AFR72832729 | ME RAYMOND ,Panne // PLUS D ALIMENTATION // - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Système de traction - Autres composants électriques - Disjoncteur | Haute priorité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM1 | Y03 | 01/10/2021 00:00:00 | 19/10/2021 09:53:19 | 19/10/2021 10:45:59 | 736493693 | SI : signalisation - PC PP EG TR MA SI | M. Jean Francois LASNIER (TM) | ||||||||
| YSM1 | Y03 | 01/10/2021 00:00:00 | 19/10/2021 09:53:19 | 19/10/2021 10:45:59 | 736493693 | EG : équipement gaine - PC PP EG TR MA SI | M. Jean Francois LASNIER (TM) | ||||||||
| YSM1 | Y03 | 01/10/2021 00:00:00 | 19/10/2021 09:53:19 | 19/10/2021 10:45:59 | 736493693 | MA : manoeuvre - PC PP EG TR MA SI | M. Jean Francois LASNIER (TM) | ||||||||
| YSM1 | Y03 | 01/10/2021 00:00:00 | 19/10/2021 09:53:19 | 19/10/2021 10:45:59 | 736493693 | PC : opérateur porte cabine - PC PP EG TR MA SI | M. Jean Francois LASNIER (TM) | ||||||||
| YSM1 | Y03 | 01/10/2021 00:00:00 | 19/10/2021 09:53:19 | 19/10/2021 10:45:59 | 736493693 | PP : portes palières - PC PP EG TR MA SI | M. Jean Francois LASNIER (TM) | ||||||||
| YSM1 | Y03 | 01/10/2021 00:00:00 | 19/10/2021 09:53:19 | 19/10/2021 10:45:59 | 736493693 | TR : treuil ou machine - PC PP EG TR MA SI | M. Jean Francois LASNIER (TM) | ||||||||
| YSM1 | Y03 | 22/10/2021 00:00:00 | 19/10/2021 09:43:43 | 19/10/2021 09:53:19 | 742452247 | MB : module de base - | M. Jean Francois LASNIER (TM) | ||||||||
| YSM3 | Y01 | 01/10/2021 14:33:47 | 01/10/2021 15:12:12 | 01/10/2021 16:17:28 | 9AFR72767747 | BRUGET ,Défaut porte // CLAQUE FORT // 5EM ETG // FERME TROP VITE // - | Disponible - Dysfonctionnement autre | Defaut technique | Remplacer | Porte et huisserie - Porte palière (battante) - Ferme porte - Ferme porte | Haute priorité | Remis en service |
BOURDIAL Jean Francois (TM)
(+) |
||
| YSM3 | Y01 | 20/09/2021 09:51:03 | 20/09/2021 10:45:03 | 20/09/2021 16:31:00 | 9AFR72742403 | MR LYOUBI ,Ascenseur à l'étage porte ouverte 6EME, "FERMEPORTE endommage" - | Indisponible - Arrêté au niveau - Porte ouverte | Vetuste | Remplacer | Porte et huisserie - Porte palière (battante) - Ferme porte - Bras de ferme porte | Haute priorité | Remis en service |
BAROUGIER Jean Christophe (TS THD)
(+) |
||
| YSM1 | Y03 | 10/09/2021 00:00:00 | 09/09/2021 14:57:48 | 09/09/2021 15:17:48 | 739222131 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 30/07/2021 00:00:00 | 27/07/2021 15:38:11 | 27/07/2021 16:00:52 | 736492852 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 18/06/2021 00:00:00 | 17/06/2021 10:27:17 | 17/06/2021 10:42:49 | 733130160 | MB : module de base - | Bourdial Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 28/05/2021 00:00:00 | 03/05/2021 11:40:53 | 03/05/2021 11:59:29 | 731729063 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM3 | Y01 | 08/04/2021 05:55:16 | 08/04/2021 06:19:04 | 12/04/2021 09:55:33 | 9AFR72435554 | MR BOUMRAH ,INFO TM // ATTENTE ASSIISTANCE TECHNIQUE // Personnes bloquées - | Indisponible - Arrêté entre étage - Porte palière fermée | Defaut technique | Régler | Equipement gaine - Limiteur de vitesse - Poulie tendeuse | Urgence Sécurité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM1 | Y03 | 30/04/2021 00:00:00 | 12/04/2021 09:30:00 | 12/04/2021 09:44:19 | 729807319 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM3 | Y04 | 16/03/2021 13:49:00 | 16/03/2021 13:54:50 | 16/03/2021 15:45:26 | 9AFR72393475 | LASNIER Jean Francois ,vibrations importantes en cabine , KFM - | Disponible - Bruit au fonctionnement | Vetuste | Vérifier | Machinerie - Treuil - Treuil | Remis en service |
LASNIER Jean Francois (TM)
(+) |
|||
| YSM3 | Y04 | 16/03/2021 11:07:11 | 16/03/2021 11:13:12 | 16/03/2021 12:06:42 | 9AFR72392953 | LASNIER Jean Francois ,vibrations anormales , KFM - | Disponible - Dysfonctionnement autre | Vetuste | Vérifier | Machinerie - Treuil - Treuil | Remis en service |
LASNIER Jean Francois (TM)
(+) |
|||
| YSM3 | Y01 | 15/03/2021 14:45:31 | 15/03/2021 15:04:34 | 15/03/2021 16:44:04 | 9AFR72391421 | MR LOUBY ,Ascenseur Bruyant EN DESCENTE/ ET VIBRATIONS / TRES GENANT - | Disponible - Bruit au fonctionnement | Vetuste | Graisser/Lubrifier | Guides et fixations - Guides contrepoids | Haute priorité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM1 | Y03 | 02/04/2021 00:00:00 | 15/03/2021 11:56:48 | 15/03/2021 12:02:41 | 727987230 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/04/2021 00:00:00 | 15/03/2021 11:12:14 | 15/03/2021 11:56:48 | 724305863 | LC : Legal complementaire - MC LC | Lasnier Jean Francois (TM) | ||||||||
| YSM1 | Y03 | 01/04/2021 00:00:00 | 15/03/2021 11:12:14 | 15/03/2021 11:56:48 | 724305863 | MC : module complet - MC LC | Lasnier Jean Francois (TM) | ||||||||
| YSM3 | Y01 | 14/03/2021 11:02:53 | 14/03/2021 11:32:37 | 15/03/2021 11:12:14 | 9AFR72389308 | MR BOUMRAH ,ARRET TM Attente assistance technique// Ascenseur bloqué entre étages RDC ET 1ER / - | Indisponible - Arrêté entre étage - Porte palière fermée | Vetuste | Vérifier | Machinerie - Génératrice - Bobine d'excitation | Haute priorité | Remis en service |
LASNIER Jean Francois (TM)
(+) |
||
| YSM1 | Y03 | 19/02/2021 00:00:00 | 16/02/2021 16:45:41 | 16/02/2021 17:08:08 | 725393828 | MB : module de base - | Lasnier Jean Francois (TM) | ||||||||
| MOD : TRB ou FRB réalisé le 23/09/2016 (Pt 5 du S-plan). Réseau 70560245 | |||||||||||||||
| YSM1 | Y03 | 08/01/2021 00:00:00 | 04/01/2021 16:00:00 | 04/01/2021 16:12:24 | 722353480 | MB : module de base - | M. Thomas MOUSSOURS () | ||||||||
Pour des raisons de performances, l'affichage est restreint dans le temps (5 ans).
Si vous recherchez des ordres de services antérieurs, alors la totalité des OS est disponible via
--> e.Carnet