Liste des Ordres de Service de l'équipement 44970384
Liste des Ordres de Service
15 ordres de services trouvés
| Type | Act. | sensemble | Date Planif/Appel | Date arrivée | Date Départ | OS | Cas THD | Description | constat | Défaut | Action | Composant | Type appel | Condition au départ | Dernier Technicien | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YSM1 | Y03 | 01/01/2026 00:00:00 | 20/02/2026 11:18:00 | 20/02/2026 11:41:00 | 868045386 | LC : Legal complementaire - MC LC | Abdul Kamran (TM) | |||||||||
| YSM1 | Y03 | 01/01/2026 00:00:00 | 20/02/2026 11:18:00 | 20/02/2026 11:41:00 | 868045386 | MC : module complet - MC LC | Abdul Kamran (TM) | |||||||||
| YSM1 | Y03 | 30/01/2026 00:00:00 | 20/02/2026 11:07:00 | 20/02/2026 11:18:00 | 871082883 | MB : module de base - | Abdul Kamran (TM) | |||||||||
| YSM3 | Y01 | 19/01/2026 10:12:58 | 10/02/2026 14:02:22 | 10/02/2026 15:29:03 | 9AFR75682769 | - MR TOURET KARIM ,Ascenseur à l'étage porte ouverte // BLQ AU 1ER ETAGE // PORTE N ARRIVE PAS A SE FERMER // BLQ ASC - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Régler | Porte et huisserie - Porte palière (auto) - Porte palière | Haute priorité | Remis en service |
DURCIN Mickael (RE)
(+) |
|||
| YSM1 | Y03 | FR_NV | 30/01/2026 00:00:00 | 30/01/2026 11:04:00 | 30/01/2026 11:09:00 | 867223458 | 94 NV : Non Visité equipement indisponi - MB | Abdul Kamran (TM) | ||||||||
| YSM3 | Y01 | 14/01/2026 11:05:49 | 15/01/2026 20:36:33 | 15/01/2026 21:02:31 | 9AFR75675448 | - MR TOURE ,Panne ETAG1 - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Systeme de commande - Module de commande | Haute priorité | Remis en service |
WILLOT Christophe (TM)
(+) |
|||
| YSM3 | Y01 | 13/01/2026 13:07:41 | 13/01/2026 19:11:09 | 13/01/2026 19:47:49 | 9AFR75673683 | - MR TOURET ,Ascenseur à l'étage porte ouverte - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Systeme de commande - Module de commande | Haute priorité | Remis en service |
()
(+) |
|||
| YSM3 | Y09 | SN_CALLIN | 01/04/2025 13:10:15 | 17/12/2025 12:33:00 | 17/12/2025 12:42:00 | 9AFR75186147 | - #CALL_IN# Défaut au démarrage | Remis en service |
ABDUL Kamran (TM)
(+) |
|
||||||
| YSM1 | Y03 | 01/07/2025 00:00:00 | 17/12/2025 08:30:00 | 17/12/2025 10:16:00 | 854407774 | EG : équipement gaine - PC PP EG TR MA SI | Abdul Kamran (TM) | |||||||||
| YSM1 | Y03 | 01/07/2025 00:00:00 | 17/12/2025 08:30:00 | 17/12/2025 10:16:00 | 854407774 | MA : manoeuvre - PC PP EG TR MA SI | Abdul Kamran (TM) | |||||||||
| YSM1 | Y03 | 01/07/2025 00:00:00 | 17/12/2025 08:30:00 | 17/12/2025 10:16:00 | 854407774 | PC : opérateur porte cabine - PC PP EG TR MA SI | Abdul Kamran (TM) | |||||||||
| YSM1 | Y03 | 01/07/2025 00:00:00 | 17/12/2025 08:30:00 | 17/12/2025 10:16:00 | 854407774 | PP : portes palières - PC PP EG TR MA SI | Abdul Kamran (TM) | |||||||||
| YSM1 | Y03 | 01/07/2025 00:00:00 | 17/12/2025 08:30:00 | 17/12/2025 10:16:00 | 854407774 | SI : signalisation - PC PP EG TR MA SI | Abdul Kamran (TM) | |||||||||
| YSM1 | Y03 | 01/07/2025 00:00:00 | 17/12/2025 08:30:00 | 17/12/2025 10:16:00 | 854407774 | TR : treuil ou machine - PC PP EG TR MA SI | Abdul Kamran (TM) | |||||||||
| YSM1 | Y03 | 12/12/2025 00:00:00 | 17/12/2025 08:13:00 | 17/12/2025 08:29:00 | 864027806 | MB : module de base - | Abdul Kamran (TM) | |||||||||
| YSM3 | Y09 | SN_URGENT | 18/08/2025 11:58:47 | 28/10/2025 12:24:00 | 28/10/2025 12:39:00 | 9AFR75428138 | SN003131 - Défaut d"appel cyclique: KCECPUc | Remis en service |
ABDUL Kamran (TM)
(+) |
|||||||
| YSM1 | Y03 | 22/08/2025 00:00:00 | 28/10/2025 12:11:00 | 28/10/2025 12:24:00 | 861962732 | MB : module de base - | Abdul Kamran (TM) | |||||||||
| YSM1 | Y03 | FR_NV | 22/08/2025 00:00:00 | 30/09/2025 11:54:00 | 30/09/2025 11:58:00 | 856246920 | 92 NV : Non Visité pas d'accès - MB | Abdul Kamran (TM) | ||||||||
| YSM3 | Y04 | 10/07/2025 11:12:26 | 10/07/2025 09:15:00 | 10/07/2025 10:33:00 | 9AFR75372836 | Travail non prévu effectué pendant l'opération de maintenance n° 853952351 - | Aucun defaut constate | Vérifier | Signalisation - Cabine - Boutons d'appel - Pressel ou base | Remis en service |
ABDUL Kamran (TM)
(+) |
|||||
| YSM1 | Y03 | 01/07/2025 00:00:00 | 10/07/2025 08:57:00 | 10/07/2025 09:15:00 | 853952351 | MB : module de base - | Abdul Kamran (TM) | |||||||||
| AS1 : Installation neuve réalisée le 18/02/2025 (Pt 5 du S-plan). Réseau 72354340 | ||||||||||||||||
| YSM4 | Y01 | 18/07/2024 09:19:10 | 03/08/2024 08:42:49 | 23/08/2024 14:28:00 | 9AFR74699791 | MME GRANDCLEC ,Ascenseur à l'étage porte fermée - | Aucun defaut constate | Vérifier | Porte et huisserie - Porte palière (auto) - Porte palière | Haute priorité | Remis en service | ABDUL Kamran (TM) | ||||
Pour des raisons de performances, l'affichage est restreint dans le temps (5 ans).
Si vous recherchez des ordres de services antérieurs, alors la totalité des OS est disponible via
--> e.Carnet