Liste des Ordres de Service de l'équipement 10526912
Liste des Ordres de Service
132 ordres de services trouvés
| Type | Act. | sensemble | Date Planif/Appel | Date arrivée | Date Départ | OS | Cas THD | Description | constat | Défaut | Action | Composant | Type appel | Condition au départ | Dernier Technicien | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YSM3 | Y09 | SN_CALLIN | 04/03/2026 09:02:42 | 04/03/2026 17:36:00 | 04/03/2026 17:47:24 | 9AFR75757506 | SN004064 - #CALL_IN# Protection retardée de la cabine active | Remis en service |
Keneut Matthieu (TM)
(+) |
|
||||||
| YSM1 | Y03 | 01/03/2026 00:00:00 | 25/02/2026 16:29:17 | 25/02/2026 16:31:09 | 867872159 | SI : signalisation - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 27/02/2026 00:00:00 | 25/02/2026 16:13:16 | 25/02/2026 16:29:17 | 869878432 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 16/01/2026 00:00:00 | 15/01/2026 16:33:29 | 15/01/2026 16:45:50 | 866293292 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 11/01/2026 17:59:14 | 12/01/2026 13:49:34 | 12/01/2026 14:43:44 | 9AFR75669926 | - ACCUEIL ,ASC DE NOUVEAU BLQ / PAR INTERM CLTE DDE GROSSE VERIF - | Disponible - Dysfonctionnement autre | Vetuste | Régler | Porte et huisserie - Porte cabine - Sécurité porte cabine - Rideau de cellule | Haute priorité | Remis en service |
PUCHAUX Nicolas (TM)
(+) |
|||
| YSM3 | Y01 | 11/01/2026 10:46:39 | 11/01/2026 13:52:43 | 11/01/2026 14:06:02 | 9AFR75669531 | - MME BEERENS ,Panne 2 ASC HS - | Indisponible - Arrêté au niveau - Porte ouverte | Utilisation anormale | Réparer | Porte et huisserie - Porte paliere (auto) - Cadre et linteaux | Haute priorité | Remis en service |
MONNIER CORENTIN (TM)
(+) |
|||
| YSM3 | Y01 | 10/01/2026 10:52:47 | 10/01/2026 12:30:00 | 10/01/2026 13:16:00 | 9AFR75668651 | - MME BEERENS ,Panne AU RDC URGENT L AUTRE APPAREIL A L ARRET - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Nettoyer - Portes | Porte et huisserie - Porte palière (auto) - Porte palière | Haute priorité | Remis en service |
PUCHAUX Nicolas (TM)
(+) |
|||
| YSM1 | Y04 | KCO_CLINICA | 18/03/2025 00:00:00 | 01/12/2025 15:41:00 | 01/12/2025 16:42:00 | 832339153 | Action Clinica Parc Prioritaire - CLI : Action Clinica Prioritaire | Keneut Matthieu (TM) | ||||||||
| YSM3 | Y04 | 01/12/2025 15:07:27 | 01/12/2025 15:18:38 | 01/12/2025 15:30:39 | 9AFR75602454 | Travail non prévu effectué pendant l'opération de maintenance n° 863962020 - | Composant use (remplacement preventif) | Remplacer | Signalisation - Cabine - Boutons d'appel - Pressel ou base | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||||
| YSM1 | Y03 | 05/12/2025 00:00:00 | 01/12/2025 15:08:27 | 01/12/2025 15:18:38 | 863962020 | MB : module de base - | M. Matthieu KENEUT (TM) | |||||||||
| YSM1 | Y03 | 24/10/2025 00:00:00 | 23/10/2025 15:14:11 | 23/10/2025 15:22:16 | 860613660 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/09/2025 00:00:00 | 15/09/2025 15:29:47 | 15/09/2025 16:31:38 | 854235458 | LC : Legal complementaire - MC LC | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/09/2025 00:00:00 | 15/09/2025 15:29:47 | 15/09/2025 16:31:38 | 854235458 | MC : module complet - MC LC | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y04 | 11/09/2025 10:44:13 | 11/09/2025 11:01:45 | 11/09/2025 11:28:20 | 9AFR75466235 | Travail non prévu effectué pendant l'opération de maintenance n° 856112637 - | Aucun defaut constate | Vérifier | Equipement gaine - Limiteur de vitesse - Poulie tendeuse | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||||
| YSM1 | Y03 | 22/08/2025 00:00:00 | 11/09/2025 10:45:13 | 11/09/2025 11:01:45 | 856112637 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 11/07/2025 00:00:00 | 09/07/2025 16:27:06 | 09/07/2025 16:38:15 | 852605981 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 30/05/2025 11:56:15 | 30/05/2025 12:13:12 | 30/05/2025 12:50:25 | 9AFR75290382 | Mme BERTHé ,Défaut porte au RDC/ frotte/ s'ouvre se ferme aléatoirement - | Disponible - Dysfonctionnement autre | Defaut technique | Régler | Porte et huisserie - Porte palière (auto) - Rail de suspente, panneaux, seuil - Panneaux | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM1 | Y03 | 23/05/2025 00:00:00 | 27/05/2025 11:53:29 | 27/05/2025 12:08:32 | 849326158 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y06 | 15/05/2025 00:00:00 | 15/05/2025 12:06:00 | 15/05/2025 12:30:00 | 9AFR75263295 | contrôle veritas - Aucun defaut constate |
Keneut Matthieu (TM)
(+) |
|||||||||
| YSM3 | Y01 | 24/04/2025 11:19:40 | 24/04/2025 17:30:18 | 24/04/2025 18:09:09 | 9AFR75227058 | ACCEUIL ,Ascenseur à l'étage porte fermée/ 3E ETG ACCEUI - | Indisponible - Arrêté entre étage - Porte palière fermée | Defaut technique | Remise a zero (reset) | Système de commande - Système de commande | Haute priorité | Remis en service |
DESCHAMPS Aymeric (TS)
(+) |
|||
| YSM1 | Y03 | 11/04/2025 00:00:00 | 11/04/2025 15:39:53 | 11/04/2025 15:56:51 | 846443345 | MB : module de base - | M. Matthieu KENEUT (TM) | |||||||||
| YSM1 | Y03 | 28/02/2025 00:00:00 | 27/02/2025 11:51:00 | 27/02/2025 12:09:28 | 830797096 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2025 00:00:00 | 27/02/2025 10:45:52 | 27/02/2025 11:51:00 | 828934670 | EG : équipement gaine - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2025 00:00:00 | 27/02/2025 10:45:52 | 27/02/2025 11:51:00 | 828934670 | MA : manoeuvre - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2025 00:00:00 | 27/02/2025 10:45:52 | 27/02/2025 11:51:00 | 828934670 | SI : signalisation - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2025 00:00:00 | 27/02/2025 10:45:52 | 27/02/2025 11:51:00 | 828934670 | PC : opérateur porte cabine - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2025 00:00:00 | 27/02/2025 10:45:52 | 27/02/2025 11:51:00 | 828934670 | PP : portes palières - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2025 00:00:00 | 27/02/2025 10:45:52 | 27/02/2025 11:51:00 | 828934670 | TR : treuil ou machine - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 18/02/2025 13:43:55 | 18/02/2025 15:00:00 | 18/02/2025 16:18:07 | 9AFR75110522 | Service Client présence d'eaux en cuvette - | Disponible - Dysfonctionnement autre | Defaut technique | Vérifier | Equipement gaine - Limiteur de vitesse - Poulie tendeuse | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
||||
| YSM3 | Y01 | 03/02/2025 08:20:11 | 03/02/2025 09:28:51 | 03/02/2025 09:41:44 | 9AFR75080012 | MME VANTARI ,Panne / BLOQUE / RDC - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Porte et huisserie - Porte cabine - Porte cabine | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM3 | Y04 | 13/01/2025 10:18:03 | 13/01/2025 10:34:30 | 13/01/2025 11:08:51 | 9AFR75038581 | Travail non prévu effectué pendant l'opération de maintenance n° 827681621 - | Aucun defaut constate | Graisser/Lubrifier | Guides et fixations - Guides contrepoids | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||||
| YSM1 | Y03 | 17/01/2025 00:00:00 | 13/01/2025 10:19:03 | 13/01/2025 10:34:30 | 827681621 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y04 | 19/12/2024 20:16:58 | 20/12/2024 14:17:49 | 20/12/2024 14:19:05 | 9AFR74997272 | ACCUEIL ,Service Client / RALENTISSEMENT AU NIVEAU DE LA PORTE AU RDC - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Porte et huisserie - Porte cabine - Opérateur de porte cabine - Carte opérateur de porte | Basse priorité | Remis en service |
DESCHAMPS Aymeric (TM)
(+) |
|||
| YSM1 | Y03 | 06/12/2024 00:00:00 | 02/12/2024 14:20:20 | 02/12/2024 14:37:29 | 825358514 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y04 | KCO_CLINICA | 12/11/2024 00:00:00 | 12/11/2024 15:48:00 | 12/11/2024 16:40:00 | 823231396 | Action Clinica Parc Prioritaire - CLI : Action Clinica Prioritaire | Keneut Matthieu (TM) | ||||||||
| YSM3 | Y01 | 04/11/2024 16:43:08 | 04/11/2024 17:55:15 | 04/11/2024 18:20:30 | 9AFR74904740 | MME BERTHE ,Ascenseur à l'étage porte ouverte // RDC / SE RE OUVRE - | Indisponible - Arrêté au niveau - Porte ouverte | Utilisation anormale | Réparer | Porte et huisserie - Porte palière (auto) - Rail de suspente, panneaux, seuil - Panneaux | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM3 | Y01 | 25/10/2024 08:58:09 | 25/10/2024 09:25:42 | 25/10/2024 11:18:28 | 9AFR74887044 | M. VANDEVERGE ,Ascenseur à l'étage porte ouverte AU 0 + BRUYANT - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Régler | Porte et huisserie - Porte cabine - Sécurité porte cabine - Rideau de cellule | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM3 | Y01 | 23/10/2024 13:25:33 | 23/10/2024 14:47:29 | 23/10/2024 16:34:28 | 9AFR74883507 | MR LAVERRE ,Ascenseur à l'étage porte ouverte - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Régler | Porte et huisserie - Porte cabine - Sécurité porte cabine - Rideau de cellule | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM1 | Y03 | 25/10/2024 00:00:00 | 23/10/2024 09:32:00 | 23/10/2024 09:43:31 | 822015523 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 06/10/2024 15:48:50 | 06/10/2024 16:29:37 | 06/10/2024 17:25:53 | 9AFR74848477 | MME BEERENS ,Panne - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Régler | Porte et huisserie - Porte cabine - Sécurité porte cabine - Cellule photo électrique | Haute priorité | Remis en service |
DESCHAMPS Nathan (TM)
(+) |
|||
| YSM3 | Y01 | 28/09/2024 12:35:28 | 29/09/2024 15:17:33 | 29/09/2024 15:41:26 | 9AFR74833848 | ACCUEIL ,Porte se ferme doucement TRES LENTE - | Disponible - Dysfonctionnement autre | Defaut technique | Régler | Porte et huisserie - Porte cabine - Sécurité porte cabine - Rideau de cellule | Basse priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM1 | Y03 | 13/09/2024 00:00:00 | 12/09/2024 11:34:15 | 12/09/2024 11:53:26 | 818870389 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 11/09/2024 16:28:09 | 11/09/2024 16:40:35 | 11/09/2024 17:02:12 |
9AFR74800582
Repet. |
M LAVERRE ,Personnes bloquées//1 PERS BLQ PMR BLQ - | Indisponible - Arrêté entre étage - Porte palière fermée | Defaut technique | Vérifier | Porte et huisserie - Porte cabine - Porte cabine | Urgence Sécurité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM3 | Y01 | 05/09/2024 14:56:48 | 05/09/2024 15:00:06 | 05/09/2024 15:49:15 |
9AFR74788874
Repet. |
Asc. à l'étage porte ouverte - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Régler | Porte et huisserie - Porte cabine - Sécurité porte cabine - Rideau de cellule | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
||||
| YSM1 | Y03 | 01/09/2024 00:00:00 | 02/09/2024 15:47:45 | 02/09/2024 16:45:18 | 815879518 | LC : Legal complementaire - MC LC | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/09/2024 00:00:00 | 02/09/2024 15:47:45 | 02/09/2024 16:45:18 | 815879518 | MC : module complet - MC LC | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 02/09/2024 12:32:56 | 02/09/2024 15:20:19 | 02/09/2024 15:47:45 |
9AFR74780893
Repet. |
M. VANDEVERGE ,Ascenseur à l'étage porte ouverte// -1 - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Régler | Porte et huisserie - Porte palière (auto) - Serrure - Serrure | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM3 | Y01 | 28/08/2024 15:26:42 | 28/08/2024 16:02:27 | 28/08/2024 16:26:16 | 9AFR74773151 | MR VANDENBERGE ,Ascenseur à l'étage porte ouverte - | Disponible - Dysfonctionnement autre | Defaut technique | Régler | Porte et huisserie - Porte palière (auto) - Rail de suspente, panneaux, seuil - Panneaux | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM1 | Y03 | 02/08/2024 00:00:00 | 29/07/2024 11:39:16 | 29/07/2024 11:51:14 | 815606027 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 14/06/2024 00:00:00 | 18/06/2024 10:37:48 | 18/06/2024 10:50:45 | 812691234 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y09 | SN_CALLIN | 11/05/2024 22:27:22 | 14/05/2024 10:01:52 | 14/05/2024 10:38:17 | 9AFR74571998 | SN004064 - Protection retardée de la cabine active | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|
||||||
| YSM1 | Y03 | 26/04/2024 00:00:00 | 02/05/2024 11:08:59 | 02/05/2024 11:30:12 | 809308760 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y09 | SN_URGENT | 15/03/2024 14:52:34 | 24/03/2024 14:35:47 | 24/03/2024 14:50:23 | 9AFR74474647 | SN004055 - Wibe ne communique pas | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|
||||||
| YSM3 | Y09 | SN_URGENT | 14/03/2024 14:06:57 | 14/03/2024 15:47:46 | 14/03/2024 16:31:24 | 9AFR74472213 | SN004055 - Wibe ne communique pas | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|
||||||
| YSM3 | Y09 | SN_URGENT | 11/03/2024 15:19:33 | 13/03/2024 10:04:15 | 13/03/2024 10:09:24 | 9AFR74465863 | SN004055 - Wibe ne communique pas | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|
||||||
| YSM1 | Y03 | 15/03/2024 00:00:00 | 13/03/2024 09:47:03 | 13/03/2024 10:04:15 | 806618874 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2024 00:00:00 | 08/03/2024 13:36:32 | 08/03/2024 14:30:15 | 803181150 | EG : équipement gaine - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2024 00:00:00 | 08/03/2024 13:36:32 | 08/03/2024 14:30:15 | 803181150 | MA : manoeuvre - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2024 00:00:00 | 08/03/2024 13:36:32 | 08/03/2024 14:30:15 | 803181150 | PC : opérateur porte cabine - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2024 00:00:00 | 08/03/2024 13:36:32 | 08/03/2024 14:30:15 | 803181150 | SI : signalisation - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2024 00:00:00 | 08/03/2024 13:36:32 | 08/03/2024 14:30:15 | 803181150 | PP : portes palières - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2024 00:00:00 | 08/03/2024 13:36:32 | 08/03/2024 14:30:15 | 803181150 | TR : treuil ou machine - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 02/02/2024 00:00:00 | 01/02/2024 10:44:42 | 01/02/2024 10:55:37 | 803106640 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 28/12/2023 10:57:43 | 28/12/2023 13:25:04 | 28/12/2023 13:50:35 | 9AFR74322682 | MR LAVERS ,Ascenseur à l'étage porte fermée//RDC - | Disponible - Dysfonctionnement autre | Defaut technique | Régler | Porte et huisserie - Porte palière (auto) - Porte palière | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM1 | Y03 | 22/12/2023 00:00:00 | 19/12/2023 11:36:20 | 19/12/2023 11:46:44 | 800478435 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/09/2023 00:00:00 | 08/11/2023 14:09:52 | 08/11/2023 14:51:01 | 791133536 | MC : module complet - MC LC | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/09/2023 00:00:00 | 08/11/2023 14:09:52 | 08/11/2023 14:51:01 | 791133536 | LC : Legal complementaire - MC LC | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y06 | 08/11/2023 00:00:00 | 08/11/2023 10:54:00 | 08/11/2023 12:01:00 | 9AFR74217345 | Service Client contrôle veritas annuel - Aucun defaut constate |
Keneut Matthieu (TM)
(+) |
|||||||||
| YSM1 | Y03 | 10/11/2023 00:00:00 | 06/11/2023 11:15:01 | 06/11/2023 11:35:41 | 797802304 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y09 | SN_URGENT | 26/10/2023 11:23:02 | 26/10/2023 14:38:47 | 26/10/2023 14:48:21 | 9AFR74192305 | SN000208 - Pas d'appel cyclique KRM, Force de signal ou problème d'unité du site | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||||||
| YSM3 | Y01 | 19/10/2023 08:52:48 | 19/10/2023 13:30:11 | 19/10/2023 13:59:21 | 9AFR74177030 | M LAVERRE ,Ascenseur à l'étage porte ouverte // RDC // PORTES S OUVRENT ET SE REFERMENT // ASC COUPE PAR LE RESP TECH DU SITE EN ATTENDANT TM - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Porte et huisserie - Porte cabine - Porte cabine | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM1 | Y04 | KCO_IL_000618 | 25/09/2023 00:00:00 | 02/10/2023 08:09:00 | 02/10/2023 11:09:00 | 795746634 | LIFTSENSE Acceleration | Diaz Jean Christophe (TS THD) | ||||||||
| YSM3 | Y01 | 27/09/2023 09:25:18 | 27/09/2023 10:00:00 | 27/09/2023 10:33:30 | 9AFR74134097 | CHRISTELLE ,Panne - | Disponible - Dysfonctionnement autre | Defaut technique | Régler | Signalisation - Cabine - Boutons d'appel - Carte | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM3 | Y04 | 26/09/2023 10:13:54 | 26/09/2023 10:27:28 | 26/09/2023 11:23:57 | 9AFR74132553 | Travail non prévu effectué pendant l'opération de maintenance n° 795229695 - | Composant use (remplacement preventif) | Remplacer | Signalisation - Cabine - Boutons d'appel - Carte | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||||
| YSM1 | Y03 | 29/09/2023 00:00:00 | 26/09/2023 10:14:54 | 26/09/2023 10:27:28 | 795229695 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 11/08/2023 00:00:00 | 18/08/2023 08:47:04 | 18/08/2023 09:02:43 | 791721558 | MB : module de base - | M. Aymeric DESCHAMPS (TM) | |||||||||
| YSM1 | Y04 | 19/07/2023 00:00:00 | 20/07/2023 13:59:00 | 20/07/2023 15:00:00 | 792947379 | TEMPORISATEUR CROUZET 24/240V 0,05S/60H | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y04 | KCO_CLINICA | 30/08/2023 00:00:00 | 20/07/2023 14:28:00 | 20/07/2023 15:00:00 | 792954492 | Action Clinica Parc Prioritaire - CLI : Action Clinica Prioritaire | Keneut Matthieu (TM) | ||||||||
| YSM1 | Y04 | 18/07/2023 00:00:00 | 19/07/2023 10:00:00 | 19/07/2023 13:10:00 | 792844657 | CONTACTEUR,110VCA 40A 3NO+1NO/1NF | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 16/07/2023 20:00:01 | 16/07/2023 20:55:00 | 17/07/2023 16:21:56 | 9AFR73999864 | ACCUEIL ,ARRET TM : defaut technique / TS Personne bloquée 3 PERSONNES BLQ AU RDC - | Indisponible - Arrêté entre étage - Porte palière fermée | Composant use (remplacement preventif) | Vérifier | Système de commande - Système de commande | Urgence Sécurité | Mis en sécurité |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM1 | Y03 | 01/03/2023 00:00:00 | 28/06/2023 10:21:18 | 28/06/2023 12:00:54 | 777399421 | EG : équipement gaine - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2023 00:00:00 | 28/06/2023 10:21:18 | 28/06/2023 12:00:54 | 777399421 | PC : opérateur porte cabine - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2023 00:00:00 | 28/06/2023 10:21:18 | 28/06/2023 12:00:54 | 777399421 | MA : manoeuvre - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2023 00:00:00 | 28/06/2023 10:21:18 | 28/06/2023 12:00:54 | 777399421 | PP : portes palières - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2023 00:00:00 | 28/06/2023 10:21:18 | 28/06/2023 12:00:54 | 777399421 | SI : signalisation - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2023 00:00:00 | 28/06/2023 10:21:18 | 28/06/2023 12:00:54 | 777399421 | TR : treuil ou machine - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 30/06/2023 00:00:00 | 27/06/2023 16:41:00 | 27/06/2023 16:52:25 | 789105556 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y04 | KCO_CLINICA | 16/06/2023 00:00:00 | 17/06/2023 17:07:00 | 17/06/2023 18:06:00 | 788510347 | Action Clinica Parc Prioritaire - CLI : Action Clinica Prioritaire | Keneut Matthieu (TM) | ||||||||
| YSM3 | Y01 | 26/05/2023 09:10:47 | 26/05/2023 09:37:52 | 26/05/2023 09:59:48 | 9AFR73898678 | M. CASTAIN ,Panne / LA PORTE DE L ASCENSEUR QUI NAVETTE AU RDC - | Indisponible - Arrêté au niveau - Porte ouverte | Utilisation anormale | Réparer | Porte et huisserie - Porte palière (auto) - Porte palière | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM1 | Y03 | 19/05/2023 00:00:00 | 16/05/2023 12:04:19 | 16/05/2023 12:15:19 | 786403336 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 04/05/2023 16:05:13 | 04/05/2023 16:13:12 | 04/05/2023 16:46:46 | 9AFR73862087 | défaut porte côté opposer - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Réparer | Porte et huisserie - Porte palière (auto) - Rail de suspente, panneaux, seuil - Panneaux | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
||||
| YSM1 | Y03 | 07/04/2023 00:00:00 | 05/04/2023 14:58:20 | 05/04/2023 15:11:52 | 782914289 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 24/03/2023 10:14:46 | 24/03/2023 14:21:32 | 24/03/2023 15:59:38 | 9AFR73791000 | MME BERTHE ,Défaut porte / BRUIT FROTTEMENT - | Disponible - Dysfonctionnement autre | Defaut technique | Régler | Porte et huisserie - Porte cabine - Opérateur de porte cabine - Operateur de porte cabine | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM1 | Y04 | 16/01/2023 00:00:00 | 24/02/2023 14:39:00 | 24/02/2023 16:51:00 | 778119367 | Rempl tube fluo | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y07 | 11/12/2022 00:00:00 | 24/02/2023 15:55:44 | 24/02/2023 16:50:43 | 772128040 | Nettoyer le limiteur de vitesse. - KONE mainteneur(IR309638416) | LEBOUAZDA Fares (TM) | |||||||||
| YSM1 | Y07 | 11/12/2022 00:00:00 | 24/02/2023 15:55:44 | 24/02/2023 16:50:43 | 772128040 | tracer reperes niveaux cables - KONE mainteneur(IR309638416) | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 24/02/2023 00:00:00 | 24/02/2023 15:01:11 | 24/02/2023 15:16:25 | 779424483 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 31/01/2023 11:34:06 | 31/01/2023 11:47:01 | 31/01/2023 12:50:28 |
9AFR73696004
Repet. |
MME BERTHé ,Asc ne dessert pas le 1er etg - | Disponible - Dysfonctionnement autre | Composant use (remplacement preventif) | Remplacer | Porte et huisserie - Porte palière (auto) - Rail de suspente, panneaux, seuil - Galet porteur | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM3 | Y01 | 25/01/2023 17:50:35 | 26/01/2023 08:05:01 | 26/01/2023 08:21:01 | 9AFR73685730 | MME BERTHE ,Panne NE VA PLUS AU SOUS SOL - | Disponible - Dysfonctionnement autre | Composant use (remplacement preventif) | Remplacer | Signalisation - Cabine - Boutons d'appel - Carte | Haute priorité | Remis en service |
DESCHAMPS Aymeric (TM)
(+) |
|||
| YSM3 | Y01 | 17/01/2023 16:00:15 | 17/01/2023 16:10:38 | 17/01/2023 16:48:48 | 9AFR73667515 | défaut bouton cabine -1 cassé - | Disponible - Dysfonctionnement autre | Composant use (remplacement preventif) | Remplacer | Signalisation - Cabine - Boutons d'appel - Carte | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
||||
| YSM1 | Y03 | 13/01/2023 00:00:00 | 11/01/2023 12:05:19 | 11/01/2023 12:19:16 | 776229053 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y04 | 07/10/2022 00:00:00 | 30/11/2022 11:57:00 | 30/11/2022 12:28:00 | 771841001 | Rempl galets de portes | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 02/12/2022 00:00:00 | 30/11/2022 11:47:00 | 30/11/2022 11:57:07 | 773306942 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/09/2022 00:00:00 | 02/11/2022 07:58:17 | 02/11/2022 09:01:18 | 762599018 | LC : Legal complementaire - MC LC | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/09/2022 00:00:00 | 02/11/2022 07:58:17 | 02/11/2022 09:01:18 | 762599018 | MC : module complet - MC LC | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y04 | 21/10/2022 09:44:55 | 21/10/2022 09:56:00 | 21/10/2022 10:12:41 | 9AFR73502121 | Travail non prévu effectué pendant l'opération de maintenance n° 769949938 - | Defaut technique | Graisser/Lubrifier | Guides et fixations - Guides contrepoids | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||||
| YSM1 | Y03 | 21/10/2022 00:00:00 | 21/10/2022 09:45:55 | 21/10/2022 09:56:00 | 769949938 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y06 | 07/10/2022 00:00:00 | 07/10/2022 14:39:00 | 07/10/2022 15:23:00 | 9AFR73476318 | contrôle veritas annuel - Aucun defaut constate |
M. Matthieu KENEUT (TM)
(+) |
|||||||||
| YSM1 | Y03 | 09/09/2022 00:00:00 | 08/09/2022 09:14:05 | 08/09/2022 09:26:23 | 765619187 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 29/07/2022 00:00:00 | 26/07/2022 13:49:19 | 26/07/2022 14:01:58 | 762529756 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y04 | KCO_CLINICA | 16/05/2022 00:00:00 | 15/06/2022 11:26:00 | 15/06/2022 12:06:00 | 756940706 | Action Clinica Parc Prioritaire - CLI : Action Clinica Prioritaire | Keneut Matthieu (TM) | ||||||||
| YSM1 | Y03 | 15/07/2022 00:00:00 | 15/06/2022 11:15:24 | 15/06/2022 11:26:00 | 761498924 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 03/06/2022 00:00:00 | 03/06/2022 14:40:15 | 03/06/2022 14:51:40 | 757773529 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 22/04/2022 00:00:00 | 19/04/2022 10:04:55 | 19/04/2022 10:09:14 | 754931819 | MB : module de base - | Deschamps Aymeric (TM) | |||||||||
| YSM3 | Y01 | 02/04/2022 16:05:39 | 02/04/2022 17:17:45 | 02/04/2022 18:00:47 | 9AFR73129781 | MME BERTHE ,Ascenseur au 3ème étage porte fermée - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Porte et huisserie - Porte cabine - Porte cabine | Haute priorité | Remis en service |
DIAZ Jean Christophe (TS THD)
(+) |
|||
| YSM3 | Y01 | 26/03/2022 14:56:42 | 26/03/2022 17:29:38 | 26/03/2022 18:01:58 | 9AFR73116265 | ACCUEIL ,Panne au 4ème étage - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Régler | Porte et huisserie - Porte cabine - Porte cabine | Haute priorité | Remis en service |
BAHAJ Rachid (TM)
(+) |
|||
| YSM1 | Y03 | 01/03/2022 00:00:00 | 24/03/2022 15:21:00 | 24/03/2022 16:52:39 | 749275752 | MA : manoeuvre - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2022 00:00:00 | 24/03/2022 15:21:00 | 24/03/2022 16:52:39 | 749275752 | EG : équipement gaine - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2022 00:00:00 | 24/03/2022 15:21:00 | 24/03/2022 16:52:39 | 749275752 | SI : signalisation - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2022 00:00:00 | 24/03/2022 15:21:00 | 24/03/2022 16:52:39 | 749275752 | PC : opérateur porte cabine - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2022 00:00:00 | 24/03/2022 15:21:00 | 24/03/2022 16:52:39 | 749275752 | PP : portes palières - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2022 00:00:00 | 24/03/2022 15:21:00 | 24/03/2022 16:52:39 | 749275752 | TR : treuil ou machine - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 24/03/2022 09:47:33 | 24/03/2022 13:30:28 | 24/03/2022 15:20:52 | 9AFR73112010 | MME BERTHE ,Défaut porte BLOQUEE AU RDC - | Indisponible - Arrêté au niveau - Porte ouverte | Vetuste | Remplacer | Porte et huisserie - Porte palière (auto) - Rail de suspente, panneaux, seuil - Galet porteur | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM3 | Y01 | 22/03/2022 10:35:28 | 22/03/2022 11:34:45 | 22/03/2022 12:26:50 | 9AFR73107745 | MME KENEU ,Ascenseur à l'étage porte ouverte RDC SUITE A UN CHOC - | Disponible - Dysfonctionnement autre | Causes exterieures - Porte sortie du rail | Réparer | Porte et huisserie - Porte palière (auto) - Porte palière | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM1 | Y03 | 04/03/2022 00:00:00 | 08/03/2022 14:08:00 | 08/03/2022 14:19:34 | 751868231 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 21/01/2022 00:00:00 | 20/01/2022 10:45:00 | 20/01/2022 11:00:30 | 748164030 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 01/01/2022 16:40:15 | 01/01/2022 18:30:06 | 01/01/2022 19:10:03 | 9AFR72966211 | MME BEERENS ,Ascenseur à l'étage porte ouverte - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Porte et huisserie - Porte cabine - Sécurité porte cabine - Rideau de cellule | Haute priorité | Remis en service |
DESCHAMPS Aymeric (TM)
(+) |
|||
| YSM1 | Y03 | 10/12/2021 00:00:00 | 07/12/2021 11:59:39 | 07/12/2021 12:10:00 | 745963929 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y07 | 17/08/2021 00:00:00 | 24/11/2021 15:39:27 | 24/11/2021 16:55:37 | 736073280 | Nettoyer le limiteur de vitesse. - KONE mainteneur(IR307578188) | M. Matthieu KENEUT (TM) | |||||||||
| YSM1 | Y07 | 17/08/2021 00:00:00 | 24/11/2021 15:39:27 | 24/11/2021 16:55:37 | 736073280 | tracer reperes niveaux cables - KONE mainteneur(IR307578188) | M. Matthieu KENEUT (TM) | |||||||||
| YSM1 | Y07 | 17/08/2021 00:00:00 | 24/11/2021 15:39:27 | 24/11/2021 16:55:37 | 736073280 | verifier fuites groupe traction - KONE mainteneur(IR307578188) | M. Matthieu KENEUT (TM) | |||||||||
| YSM3 | Y06 | 24/11/2021 00:00:00 | 24/11/2021 11:01:00 | 24/11/2021 12:02:00 | 9AFR72890553 | contrôle annuel veritas - Aucun defaut constate |
M. Matthieu KENEUT (TM)
(+) |
|||||||||
| YSM1 | Y03 | 29/10/2021 00:00:00 | 27/10/2021 09:16:41 | 27/10/2021 09:29:27 | 742477393 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y04 | 27/10/2021 08:15:41 | 27/10/2021 08:29:27 | 27/10/2021 08:49:24 | 9AFR72819346 | KENEUT MATTHIEU ,Travail non prévu effectué pendant l'opération de maintenance n° 742477393 , ExWk - | Aucun defaut constate | Graisser/Lubrifier | Guides et fixations - Guides contrepoids | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||||
| YSM1 | Y04 | KCO_CLINICA | 27/09/2021 00:00:00 | 15/10/2021 15:45:00 | 15/10/2021 16:22:00 | 740467450 | Action Clinica Parc Prioritaire - CLI : Action Clinica Prioritaire | M. Matthieu KENEUT (TM) | ||||||||
| YSM1 | Y04 | 15/09/2021 00:00:00 | 15/10/2021 14:00:00 | 15/10/2021 16:22:00 | 743729647 | Rempl galets de suspension portes | M. Matthieu KENEUT (TM) | |||||||||
| YSM1 | Y03 | 01/09/2021 00:00:00 | 21/09/2021 08:01:44 | 21/09/2021 09:30:00 | 736506722 | LC : Legal complementaire - MC LC | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/09/2021 00:00:00 | 21/09/2021 08:01:44 | 21/09/2021 08:30:51 | 736506722 | MC : module complet - MC LC | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 14/09/2021 15:13:14 | 14/09/2021 16:24:59 | 14/09/2021 17:18:53 | 9AFR72732201 | MME.QUENEU ,Ascenseur BLOQUE porte fermée AU 3E - | Disponible - Dysfonctionnement autre | Composant use (remplacement preventif) | Remplacer | Porte et huisserie - Porte palière (auto) - Rail de suspente, panneaux, seuil - Galet porteur | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM3 | Y04 | 14/09/2021 09:54:35 | 14/09/2021 10:09:17 | 14/09/2021 10:59:32 | 9AFR72731422 | KENEUT MATTHIEU ,Travail non prévu effectué pendant l'opération de maintenance n° 738123086 , ExWk - | Defaut technique | Vérifier | Porte et huisserie - Porte cabine - Porte cabine | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||||
| YSM1 | Y03 | 27/08/2021 00:00:00 | 14/09/2021 09:55:35 | 14/09/2021 10:09:17 | 738123086 | MB : module de base - | M. Matthieu KENEUT (TM) | |||||||||
| YSM3 | Y01 | 15/08/2021 14:49:05 | 15/08/2021 16:55:27 | 15/08/2021 17:26:03 | 9AFR72678274 | MME BERRRINS ,Ascenseur à l'étage porte ouverte SOUS SOL TRES BRUYANT URGENT - | Indisponible - Arrêté au niveau - Porte fermée | Defaut technique | Vérifier | Porte et huisserie - Porte cabine - Opérateur de porte cabine - Operateur de porte cabine | Haute priorité | Remis en service |
DELAVAL YVES (TM)
(+) |
|||
| YSM1 | Y03 | 16/07/2021 00:00:00 | 13/07/2021 10:28:02 | 13/07/2021 10:39:39 | 735594972 | MB : module de base - | M. Matthieu KENEUT (TM) | |||||||||
| YSM1 | Y04 | KCO_CLINICA | 08/02/2021 00:00:00 | 22/06/2021 07:57:00 | 22/06/2021 09:18:00 | 724888381 | Action Clinica Parc Prioritaire - CLI : Action Clinica Prioritaire | Keneut Matthieu (TM) | ||||||||
| YSM3 | Y04 | 02/06/2021 11:15:32 | 02/06/2021 11:27:30 | 02/06/2021 11:40:53 | 9AFR72534049 | KENEUT MATTHIEU ,Travail non prévu effectué pendant l'opération de maintenance n° 732810843 , ExWk - | Composant use (remplacement preventif) | Remplacer | Porte et huisserie - Porte palière (auto) - Rail de suspente, panneaux, seuil - Galet porteur | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||||
| YSM1 | Y03 | 04/06/2021 00:00:00 | 02/06/2021 11:16:32 | 02/06/2021 11:27:30 | 732810843 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 26/04/2021 09:41:36 | 26/04/2021 10:36:29 | 26/04/2021 11:35:07 | 9AFR72466932 | MME KENEUT ,Ascenseur à l'étage porte fermée / 1 ER - | Indisponible - Arrêté au niveau - Porte ouverte | Composant use (remplacement preventif) | Remplacer | Porte et huisserie - Porte palière (auto) - Rail de suspente, panneaux, seuil - Galet porteur | Haute priorité | Remis en service |
DESCHAMPS Aymeric (TM)
(+) |
|||
| YSM1 | Y03 | 23/04/2021 00:00:00 | 23/04/2021 16:19:09 | 23/04/2021 16:32:49 | 729821693 | MB : module de base - | Deschamps Aymeric (TM) | |||||||||
| YSM3 | Y01 | 17/04/2021 10:53:07 | 17/04/2021 15:19:39 | 17/04/2021 15:36:42 | 9AFR72453275 | MME DEMEY ,Ascenseur à l'étage porte ouverte - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Porte et huisserie - Porte cabine - Sécurité porte cabine - Rideau de cellule | Haute priorité | Remis en service |
DELAVAL YVES (TM)
(+) |
|||
| YSM3 | Y01 | 06/04/2021 09:15:24 | 06/04/2021 11:08:30 | 06/04/2021 11:30:51 | 9AFR72430765 | MME BEERENS ,Ascenseur à l'étage porte ouverte / 1 ER - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Porte et huisserie - Porte cabine - Sécurité porte cabine - Rideau de cellule | Haute priorité | Remis en service |
DESCHAMPS Aymeric (TM)
(+) |
|||
| YSM1 | Y03 | 01/03/2021 00:00:00 | 02/04/2021 09:34:31 | 02/04/2021 11:10:39 | 724320214 | TR : treuil ou machine - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2021 00:00:00 | 02/04/2021 09:34:31 | 02/04/2021 11:10:39 | 724320214 | EG : équipement gaine - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2021 00:00:00 | 02/04/2021 09:34:31 | 02/04/2021 11:10:39 | 724320214 | MA : manoeuvre - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2021 00:00:00 | 02/04/2021 09:34:31 | 02/04/2021 11:10:39 | 724320214 | PC : opérateur porte cabine - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2021 00:00:00 | 02/04/2021 09:34:31 | 02/04/2021 11:10:39 | 724320214 | PP : portes palières - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM1 | Y03 | 01/03/2021 00:00:00 | 02/04/2021 09:34:31 | 02/04/2021 11:10:39 | 724320214 | SI : signalisation - PC PP EG TR MA SI | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 20/03/2021 17:11:45 | 20/03/2021 19:17:18 | 20/03/2021 19:27:56 | 9AFR72401476 | MME KENEUT ,Ascenseur disjoncté - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Porte et huisserie - Porte palière (auto) - Porte palière | Haute priorité | Remis en service |
DELAVAL YVES (TM)
(+) |
|||
| YSM1 | Y03 | 12/03/2021 00:00:00 | 10/03/2021 17:04:11 | 10/03/2021 17:15:41 | 727320095 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 23/02/2021 08:16:55 | 23/02/2021 09:19:47 | 23/02/2021 10:13:00 | 9AFR72353788 | MME CARPENTIER ,Défaut porte PTE NAVETTE ET CLAQUE FORT - | Indisponible - Arrêté au niveau - Porte ouverte | Defaut technique | Vérifier | Porte et huisserie - Porte cabine - Opérateur de porte cabine - Composant mécanique opérateur | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM3 | Y04 | 18/02/2021 07:28:53 | 18/02/2021 08:13:12 | 18/02/2021 09:30:00 | 9AFR72345520 | DIAZ Jean Christophe ,mise en service boîtier 24/7 , KFM - | Disponible - Aucun défaut constaté | Aucun defaut constate | Régler | Système périphérique - Telesurveillance | Remis en service |
DIAZ Jean Christophe (TS THD)
(+) |
||||
| YSM3 | Y04 | 18/02/2021 07:45:24 | 18/02/2021 08:00:22 | 18/02/2021 08:56:02 | 9AFR72345542 | KENEUT MATTHIEU ,programmation 24/7 , KFM - | Disponible - Aucun défaut constaté | Aucun defaut constate | Régler | Système périphérique - Telesurveillance | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
||||
| YSM1 | Y04 | 28/01/2021 00:00:00 | 15/02/2021 17:18:00 | 15/02/2021 17:30:00 | 727396693 | Rempl tube fluo | Keneut Matthieu (TM) | |||||||||
| YSM3 | Y01 | 15/02/2021 12:43:20 | 15/02/2021 16:37:29 | 15/02/2021 17:18:05 | 9AFR72339327 | MME KENEUT ,Ascenseur à l'étage porte ouverte 4E - | Disponible - Aucun défaut constaté | Aucun defaut constate | Vérifier | Porte et huisserie - Porte palière (auto) - Porte palière | Haute priorité | Remis en service |
KENEUT MATTHIEU (TM)
(+) |
|||
| YSM1 | Y04 | KCO_24_7_ACT | 29/01/2021 00:00:00 | 15/02/2021 16:07:00 | 15/02/2021 16:32:00 | 726975544 | KONE 24/7 ACTIVATION | Diaz Jean Christophe (TS THD) | ||||||||
| MOD : TRB ou FRB réalisé le 19/12/2013 (Pt 5 du S-plan). Réseau E791052 | ||||||||||||||||
| YSM1 | Y03 | 29/01/2021 00:00:00 | 27/01/2021 11:10:45 | 27/01/2021 11:21:10 | 724349861 | MB : module de base - | Keneut Matthieu (TM) | |||||||||
Pour des raisons de performances, l'affichage est restreint dans le temps (5 ans).
Si vous recherchez des ordres de services antérieurs, alors la totalité des OS est disponible via
--> e.Carnet