Suivi Activite Telesurveillance 43475587


Liste des evenements recus sur les 3 derniers mois.

3674 evenements trouves.

Date evenement/envoi Date Reception N°Trs N° Equipement voie Code alarme Type alarme
KRM_SERVER 09/03/2026 21:09:51 09/03/2026 21:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/03/2026 21:09:52 08/03/2026 21:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/03/2026 21:09:54 07/03/2026 21:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/03/2026 21:09:56 06/03/2026 21:10:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/03/2026 21:09:57 05/03/2026 21:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/03/2026 21:09:59 04/03/2026 21:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/03/2026 21:10:00 03/03/2026 21:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/03/2026 21:10:02 02/03/2026 21:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/03/2026 21:10:03 01/03/2026 21:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/02/2026 21:10:05 28/02/2026 21:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/02/2026 21:09:31 27/02/2026 21:09:36 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/02/2026 21:09:33 26/02/2026 21:09:38 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/02/2026 21:09:35 25/02/2026 21:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/02/2026 21:09:37 24/02/2026 21:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/02/2026 21:09:38 23/02/2026 21:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/02/2026 14:07:52 23/02/2026 14:07:57 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/02/2026 21:09:40 22/02/2026 21:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/02/2026 21:09:41 21/02/2026 21:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/02/2026 23:47:18 20/02/2026 23:47:23 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/02/2026 23:47:18 20/02/2026 23:54:08 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/02/2026 21:09:43 20/02/2026 21:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/02/2026 21:09:44 19/02/2026 21:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/02/2026 21:09:45 18/02/2026 21:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/02/2026 21:09:47 17/02/2026 21:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/02/2026 21:09:49 16/02/2026 21:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/02/2026 21:09:51 15/02/2026 21:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/02/2026 21:09:52 14/02/2026 21:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/02/2026 21:09:54 13/02/2026 21:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/02/2026 21:09:56 12/02/2026 21:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/02/2026 21:09:58 11/02/2026 21:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/02/2026 21:10:00 10/02/2026 21:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/02/2026 21:10:01 09/02/2026 21:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/02/2026 21:10:02 08/02/2026 21:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/02/2026 21:10:04 07/02/2026 21:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/02/2026 22:43:29 06/02/2026 22:43:34 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/02/2026 22:43:29 06/02/2026 22:45:47 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/02/2026 21:09:30 06/02/2026 21:09:35 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/02/2026 21:09:32 05/02/2026 21:09:37 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/02/2026 21:09:35 04/02/2026 21:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/02/2026 21:09:37 03/02/2026 21:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/02/2026 21:09:38 02/02/2026 21:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/02/2026 21:09:41 01/02/2026 21:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/01/2026 21:09:41 31/01/2026 21:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/01/2026 21:09:43 30/01/2026 21:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/01/2026 21:09:44 29/01/2026 21:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/01/2026 21:09:46 28/01/2026 21:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/01/2026 21:09:47 27/01/2026 21:34:27 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/01/2026 21:09:48 26/01/2026 21:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/01/2026 21:09:52 25/01/2026 21:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/01/2026 11:31:49 25/01/2026 11:32:10 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/01/2026 11:31:49 25/01/2026 11:32:21 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/01/2026 21:09:53 24/01/2026 21:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/01/2026 21:09:54 23/01/2026 21:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/01/2026 21:09:56 22/01/2026 21:10:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/01/2026 21:09:57 21/01/2026 21:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/01/2026 21:09:59 20/01/2026 21:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/01/2026 21:10:00 19/01/2026 21:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/01/2026 21:10:03 18/01/2026 21:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/01/2026 21:10:04 17/01/2026 21:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/01/2026 21:09:30 16/01/2026 21:09:35 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/01/2026 21:09:32 15/01/2026 21:09:37 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/01/2026 21:09:33 14/01/2026 21:09:38 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/01/2026 21:09:36 13/01/2026 21:09:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/01/2026 21:09:37 12/01/2026 21:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/01/2026 21:09:39 11/01/2026 21:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/01/2026 21:09:41 10/01/2026 21:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/01/2026 21:09:41 09/01/2026 21:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/01/2026 21:09:43 08/01/2026 21:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/01/2026 21:09:46 07/01/2026 21:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/01/2026 21:09:47 06/01/2026 21:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/01/2026 21:09:49 05/01/2026 21:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/01/2026 21:09:50 04/01/2026 21:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/01/2026 21:09:52 03/01/2026 21:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/01/2026 21:09:54 02/01/2026 21:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/01/2026 21:09:55 01/01/2026 21:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/12/2025 21:09:57 31/12/2025 21:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/12/2025 10:15:58 31/12/2025 10:16:03 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 31/12/2025 10:15:58 31/12/2025 10:16:14 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/12/2025 21:09:59 30/12/2025 21:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/12/2025 21:10:01 29/12/2025 21:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/12/2025 21:10:02 28/12/2025 21:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/12/2025 08:52:35 28/12/2025 08:52:49 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 28/12/2025 08:48:15 28/12/2025 08:48:18 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/12/2025 21:10:03 27/12/2025 21:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/12/2025 22:12:15 26/12/2025 22:12:20 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/12/2025 22:12:17 25/12/2025 22:12:22 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/12/2025 18:16:11 25/12/2025 18:16:14 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/12/2025 18:16:11 25/12/2025 18:19:53 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/12/2025 22:12:18 24/12/2025 22:12:23 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/12/2025 22:12:21 23/12/2025 22:12:26 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/12/2025 22:12:22 22/12/2025 22:12:27 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/12/2025 22:12:24 21/12/2025 22:12:29 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/12/2025 22:12:25 20/12/2025 22:12:30 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/12/2025 22:12:27 19/12/2025 22:12:32 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/12/2025 20:35:17 19/12/2025 20:35:24 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 19/12/2025 20:35:17 19/12/2025 20:35:35 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/12/2025 22:12:28 18/12/2025 22:12:33 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/12/2025 22:12:30 17/12/2025 22:12:35 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/12/2025 22:12:31 16/12/2025 22:12:36 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/12/2025 15:49:04 16/12/2025 15:49:04 43475587 43475587 1,0 102 Temporary Fault Test Alarm
KRM_SERVER 16/12/2025 13:12:46 16/12/2025 13:12:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/12/2025 16:54:46 15/12/2025 14:52:18 43475587 43475587 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 14/12/2025 21:09:50 14/12/2025 21:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/12/2025 21:09:52 13/12/2025 21:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/12/2025 14:55:52 13/12/2025 14:55:56 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 13/12/2025 14:55:52 13/12/2025 14:56:02 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 13/12/2025 14:55:52 13/12/2025 14:56:07 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 13/12/2025 14:55:52 13/12/2025 14:56:13 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 12/12/2025 21:09:54 12/12/2025 21:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/12/2025 22:09:55 11/12/2025 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/12/2025 21:09:55 11/12/2025 21:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/12/2025 22:09:57 10/12/2025 22:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/12/2025 21:09:57 10/12/2025 21:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/12/2025 22:09:59 09/12/2025 22:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/12/2025 21:09:59 09/12/2025 21:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/12/2025 22:10:00 08/12/2025 22:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/12/2025 21:10:00 08/12/2025 21:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/12/2025 22:10:02 07/12/2025 22:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/12/2025 21:10:02 07/12/2025 21:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/12/2025 22:10:03 06/12/2025 22:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/12/2025 21:10:03 06/12/2025 21:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/12/2025 18:39:39 06/12/2025 18:40:32 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/12/2025 18:39:39 06/12/2025 18:42:29 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 05/12/2025 22:09:34 05/12/2025 22:09:39 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/12/2025 21:09:34 05/12/2025 21:09:39 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/12/2025 22:09:35 04/12/2025 22:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/12/2025 21:09:35 04/12/2025 21:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/12/2025 22:09:38 03/12/2025 22:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/12/2025 21:09:38 03/12/2025 21:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/12/2025 22:09:39 02/12/2025 22:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/12/2025 21:09:39 02/12/2025 21:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/12/2025 21:09:41 01/12/2025 21:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/11/2025 21:09:43 30/11/2025 21:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/11/2025 21:09:43 29/11/2025 21:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/11/2025 21:09:45 28/11/2025 21:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/11/2025 21:09:48 27/11/2025 21:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/11/2025 21:09:49 26/11/2025 21:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/11/2025 21:09:50 25/11/2025 21:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/11/2025 21:09:52 24/11/2025 21:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/11/2025 07:51:41 24/11/2025 07:51:46 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/11/2025 07:51:41 24/11/2025 07:52:41 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/11/2025 21:09:53 23/11/2025 21:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/11/2025 21:09:55 22/11/2025 21:10:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/11/2025 21:09:56 21/11/2025 21:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/11/2025 21:09:59 20/11/2025 21:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/11/2025 21:10:00 19/11/2025 21:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/11/2025 21:10:02 18/11/2025 21:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/11/2025 21:10:03 17/11/2025 21:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/11/2025 18:29:56 17/11/2025 18:30:01 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/11/2025 18:29:56 17/11/2025 18:33:09 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 16/11/2025 21:10:05 16/11/2025 21:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/11/2025 15:21:29 16/11/2025 15:21:34 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 16/11/2025 15:21:29 16/11/2025 15:22:28 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 16/11/2025 12:01:13 16/11/2025 12:01:18 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 16/11/2025 12:01:13 16/11/2025 12:01:30 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 15/11/2025 21:10:07 15/11/2025 21:10:13 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/11/2025 21:09:32 14/11/2025 21:09:37 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/11/2025 21:09:34 13/11/2025 21:09:39 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/11/2025 21:09:35 12/11/2025 21:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/11/2025 08:37:15 12/11/2025 08:37:20 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/11/2025 08:37:15 12/11/2025 08:37:26 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/11/2025 21:09:37 11/11/2025 21:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/11/2025 21:09:38 10/11/2025 21:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/11/2025 21:09:40 09/11/2025 21:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/11/2025 21:09:41 08/11/2025 21:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/11/2025 13:46:43 08/11/2025 13:46:49 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 08/11/2025 13:46:43 08/11/2025 13:47:17 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 07/11/2025 21:09:43 07/11/2025 21:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/11/2025 21:09:44 06/11/2025 21:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/11/2025 21:09:46 05/11/2025 21:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/11/2025 21:09:48 04/11/2025 21:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/11/2025 21:09:49 03/11/2025 21:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/11/2025 13:09:26 03/11/2025 13:09:31 43475587 43475587 1,0 1613 Elevator Failure Car light failed
KRM_SERVER 03/11/2025 13:09:26 03/11/2025 13:09:37 43475587 43475587 1,0 1613 Elevator Failure Car light failed
KRM_SERVER 02/11/2025 21:09:51 02/11/2025 21:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/11/2025 21:09:53 01/11/2025 21:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/10/2025 21:09:53 31/10/2025 21:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/10/2025 21:09:55 30/10/2025 21:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/10/2025 21:09:57 29/10/2025 21:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/10/2025 21:09:58 28/10/2025 21:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/10/2025 21:10:01 27/10/2025 21:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/10/2025 22:10:02 26/10/2025 22:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/10/2025 22:10:03 25/10/2025 22:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/10/2025 22:09:32 24/10/2025 22:09:37 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/10/2025 18:57:24 24/10/2025 18:57:32 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 24/10/2025 18:57:24 24/10/2025 18:57:37 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 23/10/2025 22:09:34 23/10/2025 22:09:39 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/10/2025 22:09:35 22/10/2025 22:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/10/2025 22:09:36 21/10/2025 22:09:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/10/2025 22:09:39 20/10/2025 22:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/10/2025 22:09:40 19/10/2025 22:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/10/2025 16:18:16 19/10/2025 16:18:21 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 19/10/2025 16:18:16 19/10/2025 16:19:16 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/10/2025 22:09:42 18/10/2025 22:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/10/2025 22:09:43 17/10/2025 22:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/10/2025 22:09:45 16/10/2025 22:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/10/2025 22:09:46 15/10/2025 22:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/10/2025 22:09:48 14/10/2025 22:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/10/2025 22:09:50 13/10/2025 22:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/10/2025 22:09:51 12/10/2025 22:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/10/2025 22:09:53 11/10/2025 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/10/2025 22:09:54 10/10/2025 22:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/10/2025 07:49:32 10/10/2025 07:49:37 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/10/2025 22:09:57 09/10/2025 22:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/10/2025 22:09:58 08/10/2025 22:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/10/2025 22:09:59 07/10/2025 22:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/10/2025 22:10:01 06/10/2025 22:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/10/2025 22:10:03 05/10/2025 22:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/10/2025 22:10:03 04/10/2025 22:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/10/2025 22:09:31 03/10/2025 22:09:37 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/10/2025 22:09:33 02/10/2025 22:09:38 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/10/2025 22:09:35 01/10/2025 22:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/09/2025 22:09:36 30/09/2025 22:09:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/09/2025 22:09:38 29/09/2025 22:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/09/2025 22:09:39 28/09/2025 22:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/09/2025 22:09:41 27/09/2025 22:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/09/2025 22:09:42 26/09/2025 22:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/09/2025 22:09:44 25/09/2025 22:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/09/2025 22:09:46 24/09/2025 22:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/09/2025 22:09:48 23/09/2025 22:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/09/2025 22:09:49 22/09/2025 22:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/09/2025 14:47:27 22/09/2025 14:47:27 43475587 43475587 1,0 100 Temporary Fault Unclassified Alarm
KRM_SERVER 21/09/2025 22:09:51 21/09/2025 22:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/09/2025 22:09:52 20/09/2025 22:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/09/2025 07:11:44 20/09/2025 07:11:52 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 20/09/2025 07:11:44 20/09/2025 07:11:57 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 20/09/2025 07:11:44 20/09/2025 07:12:03 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 20/09/2025 07:11:44 20/09/2025 07:12:08 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 19/09/2025 22:09:54 19/09/2025 22:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/09/2025 22:09:55 18/09/2025 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/09/2025 13:00:36 18/09/2025 13:00:42 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/09/2025 13:00:36 18/09/2025 13:01:38 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/09/2025 22:09:57 17/09/2025 22:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/09/2025 22:09:58 16/09/2025 22:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/09/2025 22:09:59 15/09/2025 22:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/09/2025 22:10:01 14/09/2025 22:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/09/2025 22:10:03 13/09/2025 22:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/09/2025 13:12:25 13/09/2025 13:12:43 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 13/09/2025 13:12:25 13/09/2025 13:13:24 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/09/2025 22:10:03 12/09/2025 22:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/09/2025 22:10:04 11/09/2025 22:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/09/2025 22:10:05 10/09/2025 22:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/09/2025 22:10:07 09/09/2025 22:10:12 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/09/2025 22:10:09 08/09/2025 22:10:14 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/09/2025 22:10:10 07/09/2025 22:10:15 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/09/2025 22:10:11 06/09/2025 22:10:16 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/09/2025 22:10:13 05/09/2025 22:10:18 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/09/2025 22:10:16 04/09/2025 22:10:21 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/09/2025 22:10:17 03/09/2025 22:10:22 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/09/2025 22:08:54 03/09/2025 22:09:00 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/09/2025 22:10:17 02/09/2025 22:10:23 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/09/2025 22:10:03 02/09/2025 22:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/09/2025 22:09:50 01/09/2025 22:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/08/2025 22:09:51 31/08/2025 22:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/08/2025 22:09:53 30/08/2025 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/08/2025 22:09:54 29/08/2025 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/08/2025 22:09:56 28/08/2025 22:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/08/2025 15:54:40 28/08/2025 15:54:45 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/08/2025 23:44:39 27/08/2025 23:44:47 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/08/2025 23:44:39 27/08/2025 23:44:59 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/08/2025 22:09:57 27/08/2025 22:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/08/2025 22:09:59 26/08/2025 22:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/08/2025 22:10:01 25/08/2025 22:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/08/2025 22:10:02 24/08/2025 22:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/08/2025 22:10:04 23/08/2025 22:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/08/2025 22:12:08 22/08/2025 22:12:13 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/08/2025 22:12:10 21/08/2025 22:12:15 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/08/2025 22:12:11 20/08/2025 22:12:16 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/08/2025 18:05:04 20/08/2025 18:05:10 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 20/08/2025 18:05:04 20/08/2025 18:05:15 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 19/08/2025 22:12:13 19/08/2025 22:12:18 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/08/2025 22:12:14 18/08/2025 22:12:19 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/08/2025 14:04:38 18/08/2025 14:04:59 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 18/08/2025 14:04:38 18/08/2025 14:05:04 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 18/08/2025 14:04:38 18/08/2025 14:05:10 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 18/08/2025 14:04:38 18/08/2025 14:05:15 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 17/08/2025 22:12:16 17/08/2025 22:12:21 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/08/2025 22:09:41 17/08/2025 22:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/08/2025 07:43:29 17/08/2025 07:43:51 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/08/2025 07:43:29 17/08/2025 07:45:00 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/08/2025 02:02:12 16/08/2025 23:59:59 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 17/08/2025 02:00:02 17/08/2025 00:00:23 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 16/08/2025 22:09:42 16/08/2025 22:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/08/2025 00:16:17 16/08/2025 00:16:22 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 16/08/2025 00:16:17 16/08/2025 00:16:49 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 15/08/2025 22:09:44 15/08/2025 22:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/08/2025 22:09:45 14/08/2025 22:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/08/2025 22:09:47 13/08/2025 22:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/08/2025 22:09:48 12/08/2025 22:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/08/2025 22:09:51 11/08/2025 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/08/2025 22:09:51 10/08/2025 22:21:30 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/08/2025 22:09:53 09/08/2025 22:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/08/2025 22:09:54 08/08/2025 22:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/08/2025 22:09:57 07/08/2025 22:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/08/2025 22:09:58 06/08/2025 22:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/08/2025 22:09:59 05/08/2025 22:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/08/2025 20:49:54 05/08/2025 20:50:04 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 05/08/2025 20:49:54 05/08/2025 20:50:59 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 05/08/2025 13:14:42 05/08/2025 13:14:52 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 05/08/2025 13:14:42 05/08/2025 13:15:12 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 05/08/2025 12:19:34 05/08/2025 12:19:44 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 05/08/2025 12:19:34 05/08/2025 12:22:03 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 04/08/2025 22:10:01 04/08/2025 22:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/08/2025 22:10:02 03/08/2025 22:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/08/2025 22:10:03 02/08/2025 22:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/08/2025 22:09:33 01/08/2025 22:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/07/2025 22:09:35 31/07/2025 22:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/07/2025 22:09:37 30/07/2025 22:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/07/2025 21:47:30 30/07/2025 21:47:35 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/07/2025 21:47:30 30/07/2025 21:49:12 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 29/07/2025 22:09:38 29/07/2025 22:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/07/2025 22:09:39 28/07/2025 22:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/07/2025 22:09:40 27/07/2025 22:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/07/2025 22:09:43 26/07/2025 22:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/07/2025 22:09:44 25/07/2025 22:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/07/2025 22:09:45 24/07/2025 22:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/07/2025 22:09:47 23/07/2025 22:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/07/2025 22:09:48 22/07/2025 22:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/07/2025 22:09:50 21/07/2025 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/07/2025 22:09:51 20/07/2025 22:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/07/2025 22:09:53 19/07/2025 22:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/07/2025 22:09:55 18/07/2025 22:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/07/2025 22:09:56 17/07/2025 22:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/07/2025 22:09:57 16/07/2025 22:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/07/2025 22:09:59 15/07/2025 22:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/07/2025 22:10:00 14/07/2025 22:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/07/2025 22:10:03 13/07/2025 22:10:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/07/2025 22:10:04 12/07/2025 22:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/07/2025 22:09:40 11/07/2025 22:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/07/2025 22:09:41 10/07/2025 22:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/07/2025 22:09:44 09/07/2025 22:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/07/2025 22:09:44 08/07/2025 22:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/07/2025 22:09:46 07/07/2025 22:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/07/2025 22:09:48 06/07/2025 22:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/07/2025 22:09:49 05/07/2025 22:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/07/2025 22:09:51 04/07/2025 22:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/07/2025 22:09:52 03/07/2025 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/07/2025 22:09:53 02/07/2025 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/07/2025 22:09:55 01/07/2025 22:10:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/06/2025 22:09:57 30/06/2025 22:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/06/2025 22:09:59 29/06/2025 22:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/06/2025 22:10:00 28/06/2025 22:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/06/2025 22:10:01 27/06/2025 22:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/06/2025 22:10:02 26/06/2025 22:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/06/2025 22:10:05 25/06/2025 22:10:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/06/2025 22:10:06 24/06/2025 22:10:12 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/06/2025 22:10:07 23/06/2025 22:10:16 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/06/2025 22:10:09 22/06/2025 22:10:15 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/06/2025 22:10:09 21/06/2025 22:10:16 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/06/2025 22:09:32 20/06/2025 22:09:39 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/06/2025 22:09:34 19/06/2025 22:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/06/2025 22:09:36 18/06/2025 22:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/06/2025 22:09:37 17/06/2025 22:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/06/2025 22:09:38 16/06/2025 22:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/06/2025 22:09:40 15/06/2025 22:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/06/2025 10:48:14 15/06/2025 10:48:20 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 15/06/2025 10:48:14 15/06/2025 10:48:59 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 14/06/2025 22:09:42 14/06/2025 22:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/06/2025 22:09:44 13/06/2025 22:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/06/2025 22:09:45 12/06/2025 22:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/06/2025 22:09:46 11/06/2025 22:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/06/2025 22:09:48 10/06/2025 22:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/06/2025 22:09:49 09/06/2025 22:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/06/2025 22:09:51 08/06/2025 22:10:19 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/06/2025 22:09:53 07/06/2025 22:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/06/2025 22:09:54 06/06/2025 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/06/2025 22:09:55 05/06/2025 22:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/06/2025 22:09:57 04/06/2025 22:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/06/2025 22:09:58 03/06/2025 22:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/06/2025 22:10:01 02/06/2025 22:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/06/2025 22:10:02 01/06/2025 22:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/05/2025 22:10:03 31/05/2025 22:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/05/2025 22:10:04 30/05/2025 22:10:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/05/2025 22:09:34 29/05/2025 22:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/05/2025 22:09:36 28/05/2025 22:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/05/2025 22:09:37 27/05/2025 22:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/05/2025 22:09:37 26/05/2025 22:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/05/2025 22:09:39 25/05/2025 22:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/05/2025 09:24:41 25/05/2025 09:24:59 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/05/2025 09:24:41 25/05/2025 09:25:40 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/05/2025 22:09:41 24/05/2025 22:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/05/2025 22:09:42 23/05/2025 22:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/05/2025 22:09:44 22/05/2025 22:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/05/2025 22:11:47 21/05/2025 22:13:18 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/05/2025 22:09:47 20/05/2025 22:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/05/2025 22:09:49 19/05/2025 22:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/05/2025 22:09:50 18/05/2025 22:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/05/2025 22:09:52 17/05/2025 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/05/2025 22:09:53 16/05/2025 22:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/05/2025 22:09:55 15/05/2025 22:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/05/2025 14:48:49 15/05/2025 14:49:08 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 15/05/2025 14:48:49 15/05/2025 14:49:36 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 15/05/2025 14:48:48 15/05/2025 14:48:58 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 15/05/2025 14:48:48 15/05/2025 14:49:26 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 14/05/2025 22:09:57 14/05/2025 22:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/05/2025 22:09:58 13/05/2025 22:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/05/2025 22:09:59 12/05/2025 22:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/05/2025 22:10:02 11/05/2025 22:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/05/2025 22:10:03 10/05/2025 22:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/05/2025 14:55:04 10/05/2025 14:55:12 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/05/2025 14:55:04 10/05/2025 14:55:33 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/05/2025 22:10:04 09/05/2025 22:10:12 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/05/2025 22:16:36 08/05/2025 22:16:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/05/2025 22:04:33 08/05/2025 22:04:39 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/05/2025 06:59:51 08/05/2025 04:48:07 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 06:59:07 08/05/2025 04:47:56 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 06:55:58 08/05/2025 04:47:53 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 06:15:53 08/05/2025 04:36:20 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 06:11:27 08/05/2025 04:36:18 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 06:10:48 08/05/2025 04:36:15 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 06:07:37 08/05/2025 04:36:14 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 06:05:45 08/05/2025 04:36:11 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 06:03:05 08/05/2025 04:26:13 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 06:02:21 08/05/2025 04:16:24 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 05:58:28 08/05/2025 04:15:31 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 05:54:47 08/05/2025 04:07:34 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 05:53:05 08/05/2025 04:01:37 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 05:52:23 08/05/2025 03:56:31 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 05:49:42 08/05/2025 03:56:17 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 05:47:52 08/05/2025 03:52:46 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 05:45:49 08/05/2025 03:52:06 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 05:43:55 08/05/2025 03:47:38 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 05:42:17 08/05/2025 03:41:58 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 05:42:17 08/05/2025 03:47:11 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 08/05/2025 05:31:13 08/05/2025 03:24:43 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 07/05/2025 22:09:34 07/05/2025 22:09:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/05/2025 22:09:36 06/05/2025 22:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/05/2025 22:09:37 05/05/2025 22:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/05/2025 22:09:47 04/05/2025 22:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/05/2025 14:52:54 04/05/2025 14:53:05 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 04/05/2025 14:52:54 04/05/2025 14:53:12 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 03/05/2025 22:09:49 03/05/2025 22:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/05/2025 22:09:50 02/05/2025 22:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/05/2025 22:09:44 01/05/2025 22:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/04/2025 22:09:46 30/04/2025 22:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/04/2025 22:09:47 29/04/2025 22:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/04/2025 22:09:49 28/04/2025 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/04/2025 22:09:50 27/04/2025 22:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/04/2025 22:09:52 26/04/2025 22:10:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/04/2025 19:06:37 26/04/2025 19:06:55 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 26/04/2025 19:06:37 26/04/2025 19:07:39 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/04/2025 22:09:53 25/04/2025 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/04/2025 22:09:54 24/04/2025 22:10:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/04/2025 22:09:57 23/04/2025 22:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/04/2025 22:09:58 22/04/2025 22:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/04/2025 22:09:59 21/04/2025 22:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/04/2025 06:48:10 21/04/2025 06:48:21 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/04/2025 06:48:10 21/04/2025 06:48:34 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/04/2025 06:45:07 21/04/2025 06:45:19 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/04/2025 06:45:07 21/04/2025 06:45:55 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/04/2025 22:10:01 20/04/2025 22:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/04/2025 22:10:03 19/04/2025 22:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/04/2025 07:14:30 19/04/2025 07:14:42 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 19/04/2025 07:14:30 19/04/2025 07:15:10 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/04/2025 22:09:32 18/04/2025 22:09:38 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/04/2025 22:09:33 17/04/2025 22:09:39 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/04/2025 22:09:35 16/04/2025 22:10:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/04/2025 22:09:36 15/04/2025 22:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/04/2025 13:35:33 15/04/2025 13:35:39 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 15/04/2025 13:35:33 15/04/2025 13:35:45 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 14/04/2025 22:09:38 14/04/2025 22:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/04/2025 22:09:39 13/04/2025 22:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/04/2025 22:09:41 12/04/2025 22:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/04/2025 22:09:42 11/04/2025 22:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/04/2025 22:09:44 10/04/2025 22:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/04/2025 22:09:47 09/04/2025 22:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/04/2025 22:09:47 08/04/2025 22:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/04/2025 22:09:48 07/04/2025 22:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/04/2025 22:09:51 06/04/2025 22:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/04/2025 22:09:52 05/04/2025 22:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/04/2025 22:09:54 04/04/2025 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/04/2025 22:09:55 03/04/2025 22:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/04/2025 22:09:57 02/04/2025 22:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/04/2025 22:09:58 01/04/2025 22:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/03/2025 22:10:00 31/03/2025 22:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/03/2025 21:00:11 31/03/2025 21:00:22 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 31/03/2025 21:00:11 31/03/2025 21:00:35 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/03/2025 21:10:02 30/03/2025 21:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/03/2025 21:10:03 29/03/2025 21:10:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/03/2025 21:09:30 28/03/2025 21:09:37 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/03/2025 21:09:31 27/03/2025 21:09:38 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/03/2025 16:39:13 27/03/2025 16:39:51 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 27/03/2025 16:39:13 27/03/2025 16:40:04 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 27/03/2025 16:39:11 27/03/2025 16:39:25 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 27/03/2025 16:39:11 27/03/2025 16:39:31 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 27/03/2025 16:39:11 27/03/2025 16:39:45 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 27/03/2025 16:39:11 27/03/2025 16:39:57 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 27/03/2025 16:38:28 27/03/2025 16:38:53 43475587 43475587 1,0 1703 Elevator Failure Start failed
KRM_SERVER 27/03/2025 16:38:28 27/03/2025 16:39:38 43475587 43475587 1,0 1703 Elevator Failure Start failed
KRM_SERVER 27/03/2025 16:37:51 27/03/2025 16:37:55 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 27/03/2025 16:37:51 27/03/2025 16:39:06 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 27/03/2025 16:37:51 27/03/2025 16:39:12 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 26/03/2025 21:09:33 26/03/2025 21:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/03/2025 21:09:34 25/03/2025 21:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/03/2025 21:09:36 24/03/2025 21:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/03/2025 21:09:38 23/03/2025 21:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/03/2025 21:09:40 22/03/2025 21:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/03/2025 21:09:41 21/03/2025 21:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/03/2025 21:09:42 20/03/2025 21:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/03/2025 21:09:44 19/03/2025 21:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/03/2025 21:09:48 18/03/2025 21:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/03/2025 21:09:48 17/03/2025 21:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/03/2025 21:09:49 16/03/2025 21:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/03/2025 21:09:50 15/03/2025 21:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/03/2025 21:09:53 14/03/2025 21:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/03/2025 21:09:55 13/03/2025 21:10:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/03/2025 21:09:57 12/03/2025 21:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/03/2025 21:09:58 11/03/2025 21:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/03/2025 05:05:41 11/03/2025 05:05:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/03/2025 21:10:00 10/03/2025 21:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/03/2025 21:10:02 09/03/2025 21:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/03/2025 21:10:03 08/03/2025 21:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/03/2025 21:09:31 07/03/2025 21:09:37 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/03/2025 21:09:32 06/03/2025 21:09:39 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/03/2025 21:09:34 05/03/2025 21:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/03/2025 21:09:35 04/03/2025 21:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/03/2025 21:09:37 03/03/2025 21:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/03/2025 21:09:39 02/03/2025 21:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/03/2025 21:09:41 01/03/2025 21:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/02/2025 22:14:06 28/02/2025 22:14:12 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 28/02/2025 22:14:06 28/02/2025 22:14:47 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 28/02/2025 21:09:42 28/02/2025 21:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/02/2025 21:09:43 27/02/2025 21:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/02/2025 21:09:46 26/02/2025 21:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/02/2025 21:09:47 25/02/2025 21:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/02/2025 21:09:49 24/02/2025 21:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/02/2025 21:09:50 23/02/2025 21:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/02/2025 21:09:52 22/02/2025 21:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/02/2025 21:09:53 21/02/2025 21:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/02/2025 21:09:55 20/02/2025 21:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/02/2025 21:09:57 19/02/2025 21:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/02/2025 16:16:26 19/02/2025 16:16:32 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/02/2025 16:15:51 19/02/2025 16:15:51 43475587 43475587 1,0 102 Temporary Fault Test Alarm
KRM_SERVER 19/02/2025 10:17:28 19/02/2025 10:17:45 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 19/02/2025 10:17:28 19/02/2025 10:18:20 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 08/02/2025 16:28:45 08/02/2025 16:28:50 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 08/02/2025 16:28:45 08/02/2025 16:29:17 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 08/02/2025 11:39:14 08/02/2025 11:39:19 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 08/02/2025 11:39:14 08/02/2025 11:39:59 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/01/2025 18:29:38 30/01/2025 18:29:56 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/01/2025 18:29:38 30/01/2025 18:31:19 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 29/01/2025 12:26:42 29/01/2025 12:27:01 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 29/01/2025 12:26:42 29/01/2025 12:27:13 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/01/2025 11:44:28 20/01/2025 11:44:32 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 20/01/2025 11:44:28 20/01/2025 11:44:38 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 20/01/2025 11:44:28 20/01/2025 11:44:43 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 11/01/2025 11:15:00 11/01/2025 11:15:07 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/01/2025 11:15:00 11/01/2025 11:16:06 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 08/01/2025 14:57:53 08/01/2025 14:57:53 43475587 43475587 1,0 103 False Alarm False Alarm
KRM_SERVER 07/01/2025 21:09:58 07/01/2025 21:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/01/2025 21:10:00 06/01/2025 21:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/01/2025 21:10:02 05/01/2025 21:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/01/2025 21:10:03 04/01/2025 21:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/01/2025 12:45:43 04/01/2025 12:45:48 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 04/01/2025 12:45:43 04/01/2025 12:45:59 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 04/01/2025 12:41:30 04/01/2025 12:41:35 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 04/01/2025 12:41:30 04/01/2025 12:42:23 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 03/01/2025 21:09:28 03/01/2025 21:09:35 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/01/2025 21:09:31 02/01/2025 21:09:37 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/01/2025 21:09:32 01/01/2025 21:09:39 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/12/2024 21:09:34 31/12/2024 21:09:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/12/2024 21:09:36 30/12/2024 21:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/12/2024 21:09:38 29/12/2024 21:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/12/2024 21:09:38 28/12/2024 21:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/12/2024 21:09:41 27/12/2024 21:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/12/2024 21:09:43 26/12/2024 21:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/12/2024 21:09:43 25/12/2024 21:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/12/2024 21:09:51 24/12/2024 21:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/12/2024 21:09:47 23/12/2024 21:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/12/2024 21:09:48 22/12/2024 21:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/12/2024 21:28:45 21/12/2024 21:29:01 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/12/2024 21:28:45 21/12/2024 21:32:44 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/12/2024 21:09:51 21/12/2024 21:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/12/2024 21:09:52 20/12/2024 21:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/12/2024 13:05:00 20/12/2024 13:05:05 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/12/2024 13:05:00 20/12/2024 13:06:07 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/12/2024 13:01:19 20/12/2024 13:01:24 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/12/2024 13:01:19 20/12/2024 13:02:26 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 19/12/2024 21:09:54 19/12/2024 21:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/12/2024 21:09:55 18/12/2024 21:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/12/2024 21:09:57 17/12/2024 21:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/12/2024 21:09:59 16/12/2024 21:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/12/2024 21:10:00 15/12/2024 21:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/12/2024 21:10:01 14/12/2024 21:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/12/2024 23:08:54 13/12/2024 23:08:59 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 13/12/2024 21:09:30 13/12/2024 21:09:38 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/12/2024 21:09:32 12/12/2024 21:09:38 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/12/2024 21:09:33 11/12/2024 21:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/12/2024 21:09:34 10/12/2024 21:09:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/12/2024 21:09:36 09/12/2024 21:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/12/2024 21:09:45 04/12/2024 21:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/12/2024 18:29:51 04/12/2024 18:29:57 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 04/12/2024 18:29:51 04/12/2024 18:30:02 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 03/12/2024 21:09:46 03/12/2024 21:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/12/2024 21:09:48 02/12/2024 21:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/12/2024 21:09:49 01/12/2024 21:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/11/2024 21:09:51 30/11/2024 21:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/11/2024 21:09:53 29/11/2024 21:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/11/2024 21:09:54 28/11/2024 21:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/11/2024 21:09:56 27/11/2024 21:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/11/2024 22:09:57 26/11/2024 22:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/11/2024 21:09:57 26/11/2024 21:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/11/2024 16:03:54 26/11/2024 16:04:03 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 26/11/2024 16:03:54 26/11/2024 16:04:10 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 26/11/2024 15:03:54 26/11/2024 15:04:03 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 26/11/2024 15:03:54 26/11/2024 15:04:10 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 25/11/2024 22:10:04 25/11/2024 22:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/11/2024 21:10:04 25/11/2024 21:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/11/2024 23:10:01 24/11/2024 23:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/11/2024 22:10:01 24/11/2024 22:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/11/2024 21:10:01 24/11/2024 21:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/11/2024 19:30:07 24/11/2024 19:30:13 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/11/2024 19:30:07 24/11/2024 19:30:55 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/11/2024 18:30:07 24/11/2024 18:30:13 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/11/2024 18:30:07 24/11/2024 18:30:55 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/11/2024 17:30:07 24/11/2024 17:30:13 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/11/2024 17:30:07 24/11/2024 17:30:55 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/11/2024 23:10:02 23/11/2024 23:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/11/2024 22:10:02 23/11/2024 22:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/11/2024 21:10:02 23/11/2024 21:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/11/2024 23:09:34 22/11/2024 23:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/11/2024 22:09:34 22/11/2024 22:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/11/2024 21:09:34 22/11/2024 21:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/11/2024 23:09:36 21/11/2024 23:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/11/2024 22:09:36 21/11/2024 22:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/11/2024 21:09:36 21/11/2024 21:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/11/2024 23:09:37 20/11/2024 23:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/11/2024 22:09:37 20/11/2024 22:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/11/2024 21:09:37 20/11/2024 21:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/11/2024 23:09:39 19/11/2024 23:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/11/2024 22:09:39 19/11/2024 22:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/11/2024 21:09:39 19/11/2024 21:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/11/2024 23:09:40 18/11/2024 23:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/11/2024 22:09:40 18/11/2024 22:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/11/2024 21:09:40 18/11/2024 21:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/11/2024 23:09:43 17/11/2024 23:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/11/2024 22:09:43 17/11/2024 22:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/11/2024 21:09:43 17/11/2024 21:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/11/2024 23:09:44 16/11/2024 23:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/11/2024 22:09:44 16/11/2024 22:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/11/2024 21:09:44 16/11/2024 21:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/11/2024 23:09:45 15/11/2024 23:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/11/2024 22:09:45 15/11/2024 22:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/11/2024 21:09:45 15/11/2024 21:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/11/2024 21:09:47 14/11/2024 21:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/11/2024 21:09:49 13/11/2024 21:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/11/2024 21:09:50 12/11/2024 21:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/11/2024 21:09:52 11/11/2024 21:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/11/2024 21:09:53 10/11/2024 21:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/11/2024 21:09:56 09/11/2024 21:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/11/2024 21:09:57 08/11/2024 21:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/11/2024 21:09:58 07/11/2024 21:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/11/2024 21:10:00 06/11/2024 21:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/11/2024 21:10:02 05/11/2024 21:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/11/2024 21:10:04 04/11/2024 21:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/11/2024 21:10:05 03/11/2024 21:10:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/11/2024 21:10:07 02/11/2024 21:10:13 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/11/2024 21:10:08 01/11/2024 21:10:15 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/10/2024 21:09:33 31/10/2024 21:09:39 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/10/2024 21:09:35 30/10/2024 21:09:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/10/2024 21:09:36 29/10/2024 21:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/10/2024 21:09:37 28/10/2024 21:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/10/2024 22:09:39 27/10/2024 22:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/10/2024 22:09:40 26/10/2024 22:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/10/2024 22:09:43 25/10/2024 22:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/10/2024 22:09:50 24/10/2024 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/10/2024 22:09:45 23/10/2024 22:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/10/2024 22:09:48 22/10/2024 22:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/10/2024 09:47:44 22/10/2024 09:47:49 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 22/10/2024 09:47:44 22/10/2024 09:48:08 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/10/2024 22:09:49 21/10/2024 22:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/10/2024 22:09:50 20/10/2024 22:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/10/2024 22:09:52 19/10/2024 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/10/2024 22:09:53 18/10/2024 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/10/2024 22:09:55 17/10/2024 22:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/10/2024 22:09:57 16/10/2024 22:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/10/2024 22:09:58 15/10/2024 22:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/10/2024 22:10:00 14/10/2024 22:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/10/2024 22:10:01 13/10/2024 22:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/10/2024 22:10:02 12/10/2024 22:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/10/2024 22:10:03 11/10/2024 22:10:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/10/2024 22:09:32 10/10/2024 22:09:38 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/10/2024 22:09:33 09/10/2024 22:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/10/2024 22:09:35 08/10/2024 22:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/10/2024 15:35:11 08/10/2024 15:35:11 43475587 43475587 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 07/10/2024 22:09:36 07/10/2024 22:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/10/2024 22:09:39 06/10/2024 22:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/10/2024 22:09:40 05/10/2024 22:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/10/2024 22:09:42 04/10/2024 22:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/10/2024 22:09:44 03/10/2024 22:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/10/2024 22:09:45 02/10/2024 22:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/10/2024 22:09:46 01/10/2024 22:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/09/2024 22:09:48 30/09/2024 22:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/09/2024 22:09:49 29/09/2024 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/09/2024 22:09:50 28/09/2024 22:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/09/2024 22:09:53 27/09/2024 22:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/09/2024 22:09:54 26/09/2024 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/09/2024 22:09:57 25/09/2024 22:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/09/2024 22:09:57 24/09/2024 22:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/09/2024 22:09:59 23/09/2024 22:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/09/2024 22:10:00 22/09/2024 22:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/09/2024 14:24:37 22/09/2024 14:24:42 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 22/09/2024 14:24:37 22/09/2024 14:29:28 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 22/09/2024 14:21:14 22/09/2024 14:21:20 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 22/09/2024 14:21:14 22/09/2024 14:22:00 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/09/2024 22:10:01 21/09/2024 22:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/09/2024 22:10:02 20/09/2024 22:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/09/2024 22:09:33 19/09/2024 22:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/09/2024 22:09:35 18/09/2024 22:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/09/2024 22:09:36 17/09/2024 22:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/09/2024 22:09:38 16/09/2024 22:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/09/2024 22:09:39 15/09/2024 22:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/09/2024 22:09:41 14/09/2024 22:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/09/2024 22:09:43 13/09/2024 22:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/09/2024 22:09:44 12/09/2024 22:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/09/2024 22:09:45 11/09/2024 22:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/09/2024 22:09:48 10/09/2024 22:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/09/2024 22:09:49 09/09/2024 22:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/09/2024 22:09:50 08/09/2024 22:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/09/2024 22:09:51 07/09/2024 22:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/09/2024 22:09:54 06/09/2024 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/09/2024 22:09:55 05/09/2024 22:10:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/09/2024 22:09:56 04/09/2024 22:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/09/2024 22:09:58 03/09/2024 22:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/09/2024 08:44:33 03/09/2024 08:44:38 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 03/09/2024 08:44:33 03/09/2024 08:45:31 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/09/2024 22:09:59 02/09/2024 22:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/09/2024 22:10:01 01/09/2024 22:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/08/2024 22:10:02 31/08/2024 22:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/08/2024 12:13:32 31/08/2024 12:13:36 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 31/08/2024 12:13:32 31/08/2024 12:14:04 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 31/08/2024 12:10:33 31/08/2024 12:10:37 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 31/08/2024 12:10:33 31/08/2024 12:11:06 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/08/2024 22:10:04 30/08/2024 22:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/08/2024 21:15:47 29/08/2024 21:15:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/08/2024 15:20:48 29/08/2024 15:20:48 43475587 43475587 1,0 100 Temporary Fault Unclassified Alarm
KRM_SERVER 29/08/2024 14:34:39 29/08/2024 14:20:27 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/08/2024 14:32:09 29/08/2024 14:20:26 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/08/2024 14:31:29 29/08/2024 14:20:23 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/08/2024 14:28:47 29/08/2024 14:20:21 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/08/2024 14:28:06 29/08/2024 14:20:18 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/08/2024 14:25:26 29/08/2024 14:20:17 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/08/2024 14:23:34 29/08/2024 14:20:14 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/08/2024 14:21:55 29/08/2024 14:20:13 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/08/2024 14:20:29 29/08/2024 14:20:10 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/08/2024 14:18:33 29/08/2024 14:20:07 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/08/2024 14:17:50 29/08/2024 14:11:03 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/08/2024 14:15:58 29/08/2024 14:10:49 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/08/2024 14:09:18 29/08/2024 13:37:48 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/08/2024 14:06:20 29/08/2024 13:26:15 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/08/2024 14:01:53 29/08/2024 13:09:05 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/08/2024 14:01:53 29/08/2024 13:12:08 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/08/2024 13:58:55 29/08/2024 13:08:51 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/08/2024 13:49:16 29/08/2024 12:42:48 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 28/08/2024 22:09:05 28/08/2024 22:09:13 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/08/2024 22:09:06 27/08/2024 22:09:14 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/08/2024 22:09:06 26/08/2024 22:09:13 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/08/2024 22:09:09 25/08/2024 22:09:17 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/08/2024 22:09:10 24/08/2024 22:09:19 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/08/2024 02:09:41 24/08/2024 02:09:47 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/08/2024 02:09:41 24/08/2024 02:10:57 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/08/2024 02:06:07 24/08/2024 02:06:13 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/08/2024 02:06:07 24/08/2024 02:07:17 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/08/2024 22:09:12 23/08/2024 22:09:18 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/08/2024 22:09:13 22/08/2024 22:09:19 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/08/2024 17:21:40 22/08/2024 17:21:46 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 22/08/2024 17:21:40 22/08/2024 17:22:14 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/08/2024 22:09:15 21/08/2024 22:09:21 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/08/2024 22:09:16 20/08/2024 22:09:22 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/08/2024 22:09:18 19/08/2024 22:09:24 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/08/2024 22:09:19 18/08/2024 22:09:25 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/08/2024 22:09:21 17/08/2024 22:09:28 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/08/2024 22:09:22 16/08/2024 22:09:30 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/08/2024 22:09:24 15/08/2024 22:09:30 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/08/2024 22:09:25 14/08/2024 22:09:33 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/08/2024 22:09:28 13/08/2024 22:09:34 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/08/2024 22:09:28 14/08/2024 10:13:12 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/08/2024 22:09:35 11/08/2024 22:09:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/08/2024 22:09:31 14/08/2024 01:29:12 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/08/2024 22:09:33 13/08/2024 21:10:17 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/08/2024 22:09:34 08/08/2024 22:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/08/2024 22:09:36 07/08/2024 22:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/08/2024 22:09:37 06/08/2024 22:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/08/2024 22:09:38 05/08/2024 22:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/08/2024 22:09:40 04/08/2024 22:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/08/2024 22:09:41 03/08/2024 22:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/08/2024 22:09:43 02/08/2024 22:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/08/2024 22:09:44 01/08/2024 22:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/07/2024 22:09:46 31/07/2024 22:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/07/2024 22:09:48 30/07/2024 22:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/07/2024 22:09:54 29/07/2024 22:56:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/07/2024 22:09:53 28/07/2024 22:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/07/2024 22:09:54 27/07/2024 22:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/07/2024 22:09:57 26/07/2024 22:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/07/2024 22:09:58 25/07/2024 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/07/2024 22:10:00 24/07/2024 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/07/2024 22:10:00 23/07/2024 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/07/2024 22:10:02 22/07/2024 22:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/07/2024 22:10:13 21/07/2024 22:10:13 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/07/2024 22:10:05 20/07/2024 22:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/07/2024 22:09:44 19/07/2024 22:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/07/2024 22:09:46 18/07/2024 22:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/07/2024 22:09:38 17/07/2024 22:09:38 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/07/2024 22:09:41 16/07/2024 22:09:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/07/2024 22:09:43 15/07/2024 22:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/07/2024 22:09:44 14/07/2024 22:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/07/2024 22:09:45 13/07/2024 22:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/07/2024 22:09:47 12/07/2024 22:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/07/2024 22:09:49 11/07/2024 22:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/07/2024 22:09:49 10/07/2024 22:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/07/2024 22:09:51 09/07/2024 22:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/07/2024 22:09:53 08/07/2024 22:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/07/2024 08:30:03 08/07/2024 08:30:09 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 08/07/2024 08:30:03 08/07/2024 08:30:22 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 07/07/2024 22:10:04 07/07/2024 22:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/07/2024 22:09:55 06/07/2024 22:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/07/2024 22:10:06 05/07/2024 22:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/07/2024 22:09:58 04/07/2024 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/07/2024 09:11:51 04/07/2024 09:11:55 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 04/07/2024 09:11:51 04/07/2024 09:12:37 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 03/07/2024 22:10:00 03/07/2024 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/07/2024 22:10:11 02/07/2024 22:10:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/07/2024 22:10:02 01/07/2024 22:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/06/2024 22:10:05 30/06/2024 22:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/06/2024 22:10:07 29/06/2024 22:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/06/2024 22:09:34 28/06/2024 22:09:34 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/06/2024 09:34:52 28/06/2024 09:34:58 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 28/06/2024 09:34:52 28/06/2024 09:35:10 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/06/2024 22:09:35 27/06/2024 22:09:35 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/06/2024 22:09:37 26/06/2024 22:09:37 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/06/2024 14:54:46 26/06/2024 14:54:46 43475587 43475587 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 25/06/2024 22:23:57 25/06/2024 22:24:01 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/06/2024 22:23:57 25/06/2024 22:24:49 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/06/2024 22:09:38 25/06/2024 22:09:38 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/06/2024 22:09:40 24/06/2024 22:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/06/2024 09:41:01 24/06/2024 09:41:05 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/06/2024 09:41:01 24/06/2024 09:41:42 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/06/2024 22:09:51 23/06/2024 22:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/06/2024 22:09:44 22/06/2024 22:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/06/2024 22:09:45 21/06/2024 22:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/06/2024 22:09:47 20/06/2024 22:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/06/2024 22:09:46 19/06/2024 22:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/06/2024 22:09:47 18/06/2024 22:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/06/2024 22:09:49 17/06/2024 22:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/06/2024 22:09:53 16/06/2024 22:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/06/2024 22:09:54 15/06/2024 22:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/06/2024 09:31:33 15/06/2024 09:31:36 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 15/06/2024 09:31:33 15/06/2024 09:32:31 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 14/06/2024 22:09:56 14/06/2024 22:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/06/2024 22:09:57 13/06/2024 22:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/06/2024 22:10:07 12/06/2024 22:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/06/2024 22:10:00 11/06/2024 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/06/2024 22:10:02 10/06/2024 22:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/06/2024 22:10:13 09/06/2024 22:10:13 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/06/2024 22:10:06 08/06/2024 22:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/06/2024 20:16:11 08/06/2024 20:16:15 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 08/06/2024 20:16:11 08/06/2024 20:16:55 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 07/06/2024 22:09:33 07/06/2024 22:09:33 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/06/2024 22:09:44 06/06/2024 22:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/06/2024 22:09:40 05/06/2024 22:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/06/2024 22:09:38 04/06/2024 22:09:38 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/06/2024 22:09:40 03/06/2024 22:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/06/2024 22:09:41 02/06/2024 22:09:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/06/2024 22:09:43 01/06/2024 22:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/05/2024 22:09:45 31/05/2024 22:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/05/2024 22:09:54 30/05/2024 22:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/05/2024 22:09:48 29/05/2024 22:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/05/2024 22:09:53 28/05/2024 22:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/05/2024 22:09:52 27/05/2024 22:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/05/2024 22:09:53 26/05/2024 22:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/05/2024 22:09:54 25/05/2024 22:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/05/2024 22:09:54 24/05/2024 22:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/05/2024 22:09:58 23/05/2024 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/05/2024 22:10:07 22/05/2024 22:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/05/2024 22:10:09 21/05/2024 22:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/05/2024 22:10:11 20/05/2024 22:10:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/05/2024 22:10:03 19/05/2024 22:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/05/2024 22:10:06 18/05/2024 22:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/05/2024 22:09:41 17/05/2024 22:09:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/05/2024 22:09:43 16/05/2024 22:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/05/2024 22:09:36 15/05/2024 22:09:36 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/05/2024 22:09:40 14/05/2024 22:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/05/2024 15:45:58 14/05/2024 15:45:58 43475587 43475587 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 13/05/2024 22:09:39 13/05/2024 22:09:39 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/05/2024 22:09:41 12/05/2024 22:09:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/05/2024 22:09:50 11/05/2024 22:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/05/2024 22:09:45 10/05/2024 22:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/05/2024 22:09:47 09/05/2024 22:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/05/2024 22:09:48 08/05/2024 22:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/05/2024 00:13:06 08/05/2024 00:13:12 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 08/05/2024 00:13:06 08/05/2024 00:13:17 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 07/05/2024 22:09:48 07/05/2024 22:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/05/2024 22:10:00 06/05/2024 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/05/2024 22:09:52 05/05/2024 22:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/05/2024 22:09:55 04/05/2024 22:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/05/2024 22:09:55 03/05/2024 22:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/05/2024 22:09:58 02/05/2024 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/05/2024 22:09:58 01/05/2024 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/04/2024 22:10:00 30/04/2024 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/04/2024 22:10:10 29/04/2024 22:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/04/2024 22:10:04 28/04/2024 22:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/04/2024 22:10:05 27/04/2024 22:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/04/2024 22:09:42 26/04/2024 22:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/04/2024 22:09:44 25/04/2024 22:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/04/2024 22:09:37 24/04/2024 22:09:37 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/04/2024 22:09:47 23/04/2024 22:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/04/2024 22:09:40 22/04/2024 22:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/04/2024 22:09:41 21/04/2024 22:09:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/04/2024 22:09:44 20/04/2024 22:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/04/2024 22:09:45 19/04/2024 22:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/04/2024 22:09:47 18/04/2024 22:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/04/2024 15:57:45 18/04/2024 15:57:45 43475587 43475587 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 18/04/2024 15:56:57 18/04/2024 15:56:57 43475587 43475587 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 17/04/2024 22:09:48 17/04/2024 22:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/04/2024 22:09:49 16/04/2024 22:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/04/2024 22:09:51 15/04/2024 22:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/04/2024 22:09:52 14/04/2024 22:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/04/2024 22:09:54 13/04/2024 22:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/04/2024 22:09:56 12/04/2024 22:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/04/2024 22:09:57 11/04/2024 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/04/2024 17:21:09 11/04/2024 17:21:12 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 11/04/2024 17:21:09 11/04/2024 17:21:18 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 10/04/2024 22:09:59 10/04/2024 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/04/2024 22:10:09 09/04/2024 22:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/04/2024 22:10:03 08/04/2024 22:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/04/2024 22:10:03 07/04/2024 22:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/04/2024 22:10:05 06/04/2024 22:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/04/2024 16:26:46 06/04/2024 16:26:52 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/04/2024 16:26:46 06/04/2024 16:27:28 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 05/04/2024 22:09:31 05/04/2024 22:09:31 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/04/2024 22:09:33 04/04/2024 22:09:33 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/04/2024 22:09:35 03/04/2024 22:09:35 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/04/2024 22:09:38 02/04/2024 22:09:38 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/04/2024 22:09:38 01/04/2024 22:09:38 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/03/2024 22:50:28 31/03/2024 22:50:33 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 31/03/2024 22:50:28 31/03/2024 22:50:49 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 31/03/2024 22:44:28 31/03/2024 22:44:33 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 31/03/2024 22:44:28 31/03/2024 22:47:55 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 31/03/2024 22:09:40 31/03/2024 22:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/03/2024 22:09:42 30/03/2024 22:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/03/2024 22:09:43 29/03/2024 22:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/03/2024 22:09:45 28/03/2024 22:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/03/2024 22:09:46 27/03/2024 22:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/03/2024 10:46:47 27/03/2024 10:46:53 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/03/2024 10:46:47 27/03/2024 10:47:09 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 26/03/2024 22:09:47 26/03/2024 22:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/03/2024 22:09:51 25/03/2024 22:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/03/2024 10:22:38 25/03/2024 10:22:41 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/03/2024 10:22:38 25/03/2024 10:25:26 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/03/2024 21:09:59 24/03/2024 21:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/03/2024 21:09:52 23/03/2024 21:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/03/2024 21:09:54 22/03/2024 21:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/03/2024 21:09:57 21/03/2024 21:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/03/2024 21:10:06 20/03/2024 21:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/03/2024 21:09:59 19/03/2024 21:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/03/2024 21:10:00 18/03/2024 21:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/03/2024 21:10:03 17/03/2024 21:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/03/2024 21:10:04 16/03/2024 21:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/03/2024 20:25:58 16/03/2024 20:26:02 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 16/03/2024 20:25:58 16/03/2024 20:26:58 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 16/03/2024 16:35:59 16/03/2024 16:36:04 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 16/03/2024 16:35:59 16/03/2024 16:37:18 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 15/03/2024 21:09:31 15/03/2024 21:09:31 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/03/2024 21:09:33 14/03/2024 21:09:33 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/03/2024 14:30:33 14/03/2024 14:30:37 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 14/03/2024 14:30:33 14/03/2024 14:30:42 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 13/03/2024 21:09:45 13/03/2024 21:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/03/2024 21:09:37 12/03/2024 21:09:37 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/03/2024 21:09:40 11/03/2024 21:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/03/2024 21:09:40 10/03/2024 21:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/03/2024 21:09:43 09/03/2024 21:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/03/2024 21:09:43 08/03/2024 21:09:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/03/2024 21:09:45 07/03/2024 21:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/03/2024 21:09:46 06/03/2024 21:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/03/2024 21:09:49 05/03/2024 21:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/03/2024 22:01:04 04/03/2024 22:01:04 43475587 43475587 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 04/03/2024 21:09:50 04/03/2024 21:09:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/03/2024 21:09:52 03/03/2024 21:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/03/2024 21:09:53 02/03/2024 21:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/03/2024 21:09:55 01/03/2024 21:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/02/2024 21:09:57 29/02/2024 21:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/02/2024 21:09:57 28/02/2024 21:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/02/2024 21:10:01 27/02/2024 21:10:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/02/2024 21:10:13 26/02/2024 21:10:13 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/02/2024 21:10:04 25/02/2024 21:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/02/2024 21:10:04 24/02/2024 21:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/02/2024 21:10:07 23/02/2024 21:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/02/2024 11:08:00 23/02/2024 11:08:05 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/02/2024 11:08:00 23/02/2024 11:08:42 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 22/02/2024 21:09:34 22/02/2024 21:09:34 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/02/2024 21:09:35 21/02/2024 21:09:35 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/02/2024 21:09:45 20/02/2024 21:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/02/2024 21:10:05 19/02/2024 21:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/02/2024 21:09:40 18/02/2024 21:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/02/2024 21:44:45 17/02/2024 21:44:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/02/2024 21:09:44 16/02/2024 21:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/02/2024 21:10:14 15/02/2024 21:10:14 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/02/2024 00:22:22 15/02/2024 00:22:22 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/02/2024 21:09:47 14/02/2024 21:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/02/2024 21:10:15 13/02/2024 21:10:15 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/02/2024 21:10:12 12/02/2024 21:10:12 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/02/2024 21:10:01 11/02/2024 21:10:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/02/2024 21:09:53 10/02/2024 21:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/02/2024 11:03:09 10/02/2024 11:03:14 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/02/2024 11:03:09 10/02/2024 11:05:06 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/02/2024 21:09:55 09/02/2024 21:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/02/2024 21:09:56 08/02/2024 21:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/02/2024 21:09:59 07/02/2024 21:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/02/2024 21:10:00 06/02/2024 21:10:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/02/2024 19:07:49 06/02/2024 19:07:54 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/02/2024 18:49:59 06/02/2024 18:50:04 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/02/2024 18:49:59 06/02/2024 19:05:54 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 05/02/2024 21:10:01 05/02/2024 21:10:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/02/2024 21:10:12 04/02/2024 21:10:12 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/02/2024 14:54:47 04/02/2024 14:54:52 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 04/02/2024 14:54:47 04/02/2024 14:56:01 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 03/02/2024 21:10:06 03/02/2024 21:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/02/2024 21:10:06 02/02/2024 21:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/02/2024 21:09:32 01/02/2024 21:09:32 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/01/2024 21:09:34 31/01/2024 21:09:34 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/01/2024 21:09:41 30/01/2024 21:09:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/01/2024 21:09:37 29/01/2024 21:09:37 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/01/2024 21:09:48 28/01/2024 21:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/01/2024 21:09:46 27/01/2024 21:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/01/2024 21:09:42 26/01/2024 21:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/01/2024 21:09:46 25/01/2024 21:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/01/2024 21:09:46 24/01/2024 21:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/01/2024 21:09:56 23/01/2024 21:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/01/2024 21:09:49 22/01/2024 21:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/01/2024 14:23:02 22/01/2024 14:23:02 43475587 43475587 1,0 102 Temporary Fault Test Alarm
KRM_SERVER 21/01/2024 21:10:01 21/01/2024 21:10:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/01/2024 21:09:52 20/01/2024 21:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/01/2024 21:10:02 19/01/2024 21:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/01/2024 21:10:04 18/01/2024 21:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/01/2024 21:09:57 17/01/2024 21:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/01/2024 21:10:10 16/01/2024 21:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/01/2024 10:02:33 16/01/2024 10:02:38 43475587 43475587 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 16/01/2024 10:02:33 16/01/2024 10:02:44 43475587 43475587 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 16/01/2024 10:02:33 16/01/2024 10:02:49 43475587 43475587 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 16/01/2024 10:02:33 16/01/2024 10:02:55 43475587 43475587 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 16/01/2024 09:56:46 16/01/2024 09:57:02 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 16/01/2024 09:56:46 16/01/2024 09:57:07 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 16/01/2024 09:56:46 16/01/2024 11:18:15 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 16/01/2024 09:56:46 16/01/2024 11:18:20 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 16/01/2024 09:56:35 16/01/2024 09:56:51 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 16/01/2024 09:56:35 16/01/2024 09:57:18 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 16/01/2024 09:56:34 16/01/2024 09:56:40 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 16/01/2024 09:56:34 16/01/2024 09:57:13 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 15/01/2024 21:10:01 15/01/2024 21:10:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/01/2024 14:12:31 15/01/2024 14:12:45 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 15/01/2024 14:12:31 15/01/2024 14:12:50 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 15/01/2024 14:12:31 15/01/2024 14:26:15 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 15/01/2024 14:12:31 15/01/2024 14:26:21 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 14/01/2024 21:10:33 14/01/2024 21:10:33 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/01/2024 14:30:49 14/01/2024 14:30:54 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 14/01/2024 14:30:49 14/01/2024 14:31:05 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 13/01/2024 21:10:23 13/01/2024 21:10:23 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/01/2024 21:10:46 12/01/2024 21:10:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/01/2024 22:11:52 11/01/2024 22:11:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/01/2024 22:12:03 10/01/2024 22:12:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/01/2024 22:11:56 09/01/2024 22:11:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/01/2024 22:11:58 08/01/2024 22:11:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/01/2024 22:11:59 07/01/2024 22:11:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/01/2024 22:12:05 06/01/2024 22:12:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/01/2024 22:12:28 05/01/2024 22:12:28 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/01/2024 22:12:06 04/01/2024 22:12:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/01/2024 22:12:06 03/01/2024 22:12:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/01/2024 22:12:17 02/01/2024 22:12:17 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/01/2024 14:41:41 02/01/2024 14:41:45 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 02/01/2024 14:41:41 02/01/2024 14:41:51 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 02/01/2024 14:41:41 02/01/2024 14:42:02 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 02/01/2024 14:41:41 02/01/2024 14:42:07 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 01/01/2024 22:12:25 01/01/2024 22:12:25 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/12/2023 22:12:11 31/12/2023 22:12:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/12/2023 22:12:12 30/12/2023 22:12:12 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/12/2023 22:12:15 29/12/2023 22:12:15 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/12/2023 22:12:16 28/12/2023 22:12:16 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/12/2023 14:07:53 28/12/2023 14:07:59 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/12/2023 14:07:53 28/12/2023 14:08:04 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/12/2023 14:07:53 28/12/2023 14:08:52 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/12/2023 14:07:53 28/12/2023 14:08:57 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/12/2023 13:58:35 28/12/2023 13:59:22 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 13:58:34 28/12/2023 13:59:16 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 13:58:32 28/12/2023 13:58:48 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 28/12/2023 13:58:32 28/12/2023 13:59:11 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 28/12/2023 13:58:31 28/12/2023 13:58:37 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 28/12/2023 13:58:31 28/12/2023 13:59:05 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 28/12/2023 13:28:18 28/12/2023 13:28:35 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 13:28:18 28/12/2023 13:58:59 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 13:28:17 28/12/2023 13:28:24 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 13:28:17 28/12/2023 13:58:54 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 12:28:05 28/12/2023 12:28:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 12:28:05 28/12/2023 12:28:31 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 12:27:58 28/12/2023 12:28:14 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 12:27:58 28/12/2023 12:28:20 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 12:27:51 28/12/2023 12:27:58 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 12:27:51 28/12/2023 12:28:09 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 11:27:39 28/12/2023 11:27:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 11:27:39 28/12/2023 11:27:59 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 11:27:32 28/12/2023 11:27:42 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 11:27:32 28/12/2023 11:27:48 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 11:27:25 28/12/2023 11:27:31 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 11:27:25 28/12/2023 11:27:37 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 10:27:12 28/12/2023 10:27:28 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 10:27:12 28/12/2023 10:27:33 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 10:27:06 28/12/2023 10:27:16 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 10:27:06 28/12/2023 10:27:22 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 10:26:59 28/12/2023 10:27:05 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 10:26:59 28/12/2023 10:27:11 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 09:26:46 28/12/2023 09:27:01 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 09:26:46 28/12/2023 09:27:06 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 09:26:40 28/12/2023 09:26:50 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 09:26:40 28/12/2023 09:26:55 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 09:26:33 28/12/2023 09:26:39 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 09:26:33 28/12/2023 09:26:45 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 08:26:20 28/12/2023 08:26:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 08:26:20 28/12/2023 08:26:46 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 08:26:13 28/12/2023 08:26:29 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 08:26:13 28/12/2023 08:26:35 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 08:26:06 28/12/2023 08:26:13 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 08:26:06 28/12/2023 08:26:24 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 07:25:54 28/12/2023 07:26:14 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 07:25:54 28/12/2023 07:26:20 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 07:25:47 28/12/2023 07:26:03 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 07:25:47 28/12/2023 07:26:09 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 07:25:40 28/12/2023 07:25:47 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 07:25:40 28/12/2023 07:25:58 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 06:25:27 28/12/2023 06:25:43 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 06:25:27 28/12/2023 06:25:48 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 06:25:21 28/12/2023 06:25:32 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 06:25:21 28/12/2023 06:25:37 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 06:25:14 28/12/2023 06:25:21 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 06:25:14 28/12/2023 06:25:26 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 05:25:01 28/12/2023 05:25:16 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 05:25:01 28/12/2023 05:25:22 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 05:24:55 28/12/2023 05:25:05 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 05:24:55 28/12/2023 05:25:11 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 05:24:48 28/12/2023 05:24:54 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 05:24:48 28/12/2023 05:25:00 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 04:24:35 28/12/2023 04:24:50 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 04:24:35 28/12/2023 04:24:57 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 04:24:28 28/12/2023 04:24:39 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 04:24:28 28/12/2023 04:24:45 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 04:24:22 28/12/2023 04:24:28 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 04:24:22 28/12/2023 04:24:34 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 03:24:08 28/12/2023 03:24:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 03:24:08 28/12/2023 03:24:36 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 03:24:01 28/12/2023 03:24:19 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 03:24:01 28/12/2023 03:24:24 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 03:23:55 28/12/2023 03:24:02 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 03:23:55 28/12/2023 03:24:13 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 02:23:42 28/12/2023 02:24:04 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 02:23:42 28/12/2023 02:24:09 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 02:23:35 28/12/2023 02:23:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 02:23:35 28/12/2023 02:23:58 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 02:23:28 28/12/2023 02:23:36 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 02:23:28 28/12/2023 02:23:47 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 01:23:16 28/12/2023 01:23:37 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 01:23:16 28/12/2023 01:23:43 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 01:23:09 28/12/2023 01:23:26 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 01:23:09 28/12/2023 01:23:32 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 01:23:02 28/12/2023 01:23:10 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 01:23:02 28/12/2023 01:23:21 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 00:22:50 28/12/2023 00:23:11 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 00:22:50 28/12/2023 00:23:17 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 00:22:43 28/12/2023 00:23:00 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 00:22:43 28/12/2023 00:23:06 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 00:22:36 28/12/2023 00:22:44 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/12/2023 00:22:36 28/12/2023 00:22:55 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 23:22:23 27/12/2023 23:22:39 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 23:22:23 27/12/2023 23:22:45 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 23:22:16 27/12/2023 23:22:28 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 23:22:16 27/12/2023 23:22:34 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 23:22:10 27/12/2023 23:22:17 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 23:22:10 27/12/2023 23:22:23 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 22:21:57 27/12/2023 22:22:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 22:21:57 27/12/2023 22:22:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 22:21:50 27/12/2023 22:22:14 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 22:21:50 27/12/2023 22:22:19 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 22:21:44 27/12/2023 22:21:51 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 22:21:44 27/12/2023 22:22:08 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 22:12:26 27/12/2023 22:12:26 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/12/2023 21:21:31 27/12/2023 21:21:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 21:21:31 27/12/2023 21:21:58 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 21:21:24 27/12/2023 21:21:42 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 21:21:24 27/12/2023 21:21:47 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 21:21:17 27/12/2023 21:21:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 21:21:17 27/12/2023 21:21:36 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 20:21:05 27/12/2023 20:21:27 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 20:21:05 27/12/2023 20:21:32 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 20:20:58 27/12/2023 20:21:15 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 20:20:58 27/12/2023 20:21:21 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 20:20:51 27/12/2023 20:20:59 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 20:20:51 27/12/2023 20:21:10 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 19:20:38 27/12/2023 19:20:55 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 19:20:38 27/12/2023 19:21:00 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 19:20:32 27/12/2023 19:20:44 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 19:20:32 27/12/2023 19:20:49 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 19:20:25 27/12/2023 19:20:33 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 19:20:25 27/12/2023 19:20:38 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 18:20:12 27/12/2023 18:20:28 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 18:20:12 27/12/2023 18:20:34 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 18:20:06 27/12/2023 18:20:17 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 18:20:06 27/12/2023 18:20:23 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 18:19:59 27/12/2023 18:20:06 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 18:19:59 27/12/2023 18:20:12 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 17:19:46 27/12/2023 17:20:08 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 17:19:46 27/12/2023 17:20:13 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 17:19:39 27/12/2023 17:19:57 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 17:19:39 27/12/2023 17:20:02 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 17:19:33 27/12/2023 17:19:40 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 17:19:33 27/12/2023 17:19:51 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 16:19:20 27/12/2023 16:19:42 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 16:19:20 27/12/2023 16:19:47 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 16:19:13 27/12/2023 16:19:31 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 16:19:13 27/12/2023 16:19:36 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 16:19:06 27/12/2023 16:19:14 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 16:19:06 27/12/2023 16:19:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 15:18:54 27/12/2023 15:19:10 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 15:18:54 27/12/2023 15:19:15 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 15:18:47 27/12/2023 15:18:59 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 15:18:47 27/12/2023 15:19:04 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 15:18:40 27/12/2023 15:18:48 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 15:18:40 27/12/2023 15:18:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 14:18:28 27/12/2023 14:18:44 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 14:18:28 27/12/2023 14:18:49 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 14:18:21 27/12/2023 14:18:33 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 14:18:21 27/12/2023 14:18:38 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 14:18:14 27/12/2023 14:18:22 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 14:18:14 27/12/2023 14:18:27 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 13:18:01 27/12/2023 13:18:18 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 13:18:01 27/12/2023 13:18:24 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 13:17:54 27/12/2023 13:18:07 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 13:17:54 27/12/2023 13:18:13 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 13:17:48 27/12/2023 13:17:56 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 13:17:48 27/12/2023 13:18:01 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 12:17:35 27/12/2023 12:17:57 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 12:17:35 27/12/2023 12:18:03 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 12:17:28 27/12/2023 12:17:46 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 12:17:28 27/12/2023 12:17:52 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 12:17:22 27/12/2023 12:17:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 12:17:22 27/12/2023 12:17:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 11:17:09 27/12/2023 11:17:32 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 11:17:09 27/12/2023 11:17:37 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 11:17:02 27/12/2023 11:17:20 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 11:17:02 27/12/2023 11:17:26 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 11:16:56 27/12/2023 11:17:03 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 11:16:56 27/12/2023 11:17:14 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 10:16:43 27/12/2023 10:16:59 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 10:16:43 27/12/2023 10:17:05 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 10:16:36 27/12/2023 10:16:48 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 10:16:36 27/12/2023 10:16:54 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 10:16:29 27/12/2023 10:16:42 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 10:16:29 27/12/2023 10:16:43 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 09:16:17 27/12/2023 09:16:39 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 09:16:17 27/12/2023 09:16:44 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 09:16:10 27/12/2023 09:16:28 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 09:16:10 27/12/2023 09:16:33 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 09:16:03 27/12/2023 09:16:11 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 09:16:03 27/12/2023 09:16:22 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 08:15:50 27/12/2023 08:16:07 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 08:15:50 27/12/2023 08:16:12 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 08:15:44 27/12/2023 08:15:56 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 08:15:44 27/12/2023 08:16:02 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 08:15:37 27/12/2023 08:15:45 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 08:15:37 27/12/2023 08:15:50 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 07:15:24 27/12/2023 07:15:46 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 07:15:24 27/12/2023 07:15:52 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 07:15:17 27/12/2023 07:15:35 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 07:15:17 27/12/2023 07:15:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 07:15:11 27/12/2023 07:15:19 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 07:15:11 27/12/2023 07:15:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 06:14:58 27/12/2023 06:15:20 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 06:14:58 27/12/2023 06:15:26 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 06:14:51 27/12/2023 06:15:09 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 06:14:51 27/12/2023 06:15:14 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 06:14:45 27/12/2023 06:14:52 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 06:14:45 27/12/2023 06:15:03 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 05:14:32 27/12/2023 05:14:49 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 05:14:32 27/12/2023 05:14:55 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 05:14:25 27/12/2023 05:14:38 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 05:14:25 27/12/2023 05:14:43 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 05:14:18 27/12/2023 05:14:27 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 05:14:18 27/12/2023 05:14:32 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 04:14:06 27/12/2023 04:14:28 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 04:14:06 27/12/2023 04:14:33 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 04:13:59 27/12/2023 04:14:17 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 04:13:59 27/12/2023 04:14:22 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 04:13:52 27/12/2023 04:14:00 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 04:13:52 27/12/2023 04:14:12 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 03:13:39 27/12/2023 03:13:56 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 03:13:39 27/12/2023 03:14:01 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 03:13:33 27/12/2023 03:13:45 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 03:13:33 27/12/2023 03:13:50 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 03:13:26 27/12/2023 03:13:34 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 03:13:26 27/12/2023 03:13:39 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 02:13:13 27/12/2023 02:13:35 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 02:13:13 27/12/2023 02:13:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 02:13:06 27/12/2023 02:13:24 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 02:13:06 27/12/2023 02:13:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 02:13:00 27/12/2023 02:13:08 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 02:13:00 27/12/2023 02:13:19 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 01:12:47 27/12/2023 01:13:04 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 01:12:40 27/12/2023 01:12:58 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 01:12:40 27/12/2023 01:13:09 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 01:12:34 27/12/2023 01:12:42 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 01:12:34 27/12/2023 01:12:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 00:12:21 27/12/2023 00:21:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 00:12:14 27/12/2023 00:21:59 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 00:12:07 27/12/2023 00:22:04 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 00:11:05 27/12/2023 00:22:10 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 00:10:59 27/12/2023 00:22:15 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/12/2023 00:10:46 27/12/2023 00:12:30 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 27/12/2023 00:10:46 27/12/2023 00:12:36 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 27/12/2023 00:10:46 27/12/2023 00:22:32 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 27/12/2023 00:10:46 27/12/2023 00:22:37 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 27/12/2023 00:10:45 27/12/2023 00:12:14 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 27/12/2023 00:10:45 27/12/2023 00:12:19 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 27/12/2023 00:10:44 27/12/2023 00:11:46 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 27/12/2023 00:10:44 27/12/2023 00:11:52 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 27/12/2023 00:10:44 27/12/2023 00:12:03 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 27/12/2023 00:10:44 27/12/2023 00:12:08 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 27/12/2023 00:10:44 27/12/2023 00:22:43 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 27/12/2023 00:10:43 27/12/2023 00:10:51 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/12/2023 00:10:43 27/12/2023 00:11:07 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/12/2023 00:10:43 27/12/2023 00:11:30 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 27/12/2023 00:10:43 27/12/2023 00:11:57 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/12/2023 00:10:43 27/12/2023 00:12:47 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/12/2023 00:10:43 27/12/2023 00:22:48 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 27/12/2023 00:05:38 27/12/2023 00:11:35 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/12/2023 00:05:38 27/12/2023 00:12:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 00:05:37 27/12/2023 00:11:02 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/12/2023 00:05:21 27/12/2023 00:06:01 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/12/2023 00:05:19 27/12/2023 00:05:45 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/12/2023 00:05:19 27/12/2023 00:05:50 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/12/2023 00:05:18 27/12/2023 00:05:33 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/12/2023 00:05:14 27/12/2023 00:05:22 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/12/2023 00:05:14 27/12/2023 00:05:39 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/12/2023 00:04:57 27/12/2023 00:05:06 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/12/2023 00:04:57 27/12/2023 00:05:11 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/12/2023 00:04:57 27/12/2023 00:05:28 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/12/2023 00:04:57 27/12/2023 00:21:36 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/12/2023 00:00:32 27/12/2023 00:00:40 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 00:00:32 27/12/2023 00:00:45 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/12/2023 00:00:32 27/12/2023 00:01:02 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 00:00:32 27/12/2023 00:01:07 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/12/2023 00:00:32 27/12/2023 00:05:17 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/12/2023 00:00:32 27/12/2023 00:12:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 00:00:32 27/12/2023 00:21:42 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 27/12/2023 00:00:32 27/12/2023 00:21:48 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 26/12/2023 23:00:19 26/12/2023 23:00:36 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 23:00:19 26/12/2023 23:00:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 23:00:12 26/12/2023 23:00:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 23:00:12 26/12/2023 23:00:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 23:00:06 26/12/2023 23:00:14 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 23:00:06 26/12/2023 23:00:19 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 22:12:19 26/12/2023 22:12:19 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/12/2023 21:59:53 26/12/2023 22:00:09 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 21:59:53 26/12/2023 22:00:15 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 21:59:46 26/12/2023 21:59:58 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 21:59:46 26/12/2023 22:00:04 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 21:59:39 26/12/2023 21:59:48 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 21:59:39 26/12/2023 21:59:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 20:59:27 26/12/2023 20:59:43 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 20:59:27 26/12/2023 20:59:49 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 20:59:20 26/12/2023 20:59:32 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 20:59:20 26/12/2023 20:59:38 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 20:59:13 26/12/2023 20:59:21 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 20:59:13 26/12/2023 20:59:27 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 19:59:00 26/12/2023 19:59:23 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 19:59:00 26/12/2023 19:59:28 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 19:58:53 26/12/2023 19:59:12 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 19:58:53 26/12/2023 19:59:17 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 19:58:47 26/12/2023 19:58:55 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 19:58:47 26/12/2023 19:59:06 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 18:58:34 26/12/2023 18:58:57 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 18:58:34 26/12/2023 18:59:02 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 18:58:27 26/12/2023 18:58:46 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 18:58:27 26/12/2023 18:58:51 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 18:58:21 26/12/2023 18:58:29 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 18:58:21 26/12/2023 18:58:40 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 17:58:08 26/12/2023 17:58:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 17:58:08 26/12/2023 17:58:36 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 17:58:01 26/12/2023 17:58:19 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 17:58:01 26/12/2023 17:58:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 17:57:54 26/12/2023 17:58:03 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 17:57:54 26/12/2023 17:58:14 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 16:57:42 26/12/2023 16:57:59 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 16:57:42 26/12/2023 16:58:04 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 16:57:35 26/12/2023 16:57:48 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 16:57:35 26/12/2023 16:57:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 16:57:28 26/12/2023 16:57:37 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 16:57:28 26/12/2023 16:57:42 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 15:57:16 26/12/2023 15:57:32 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 15:57:16 26/12/2023 15:57:38 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 15:57:09 26/12/2023 15:57:21 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 15:57:09 26/12/2023 15:57:27 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 15:57:02 26/12/2023 15:57:10 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 15:57:02 26/12/2023 15:57:16 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 14:56:50 26/12/2023 14:57:12 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 14:56:50 26/12/2023 14:57:17 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 14:56:43 26/12/2023 14:57:01 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 14:56:43 26/12/2023 14:57:06 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 14:56:36 26/12/2023 14:56:44 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 14:56:36 26/12/2023 14:56:55 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 13:56:23 26/12/2023 13:56:45 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 13:56:23 26/12/2023 13:56:51 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 13:56:16 26/12/2023 13:56:34 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 13:56:16 26/12/2023 13:56:40 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 13:56:10 26/12/2023 13:56:18 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 13:56:10 26/12/2023 13:56:29 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 12:55:57 26/12/2023 12:56:14 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 12:55:57 26/12/2023 12:56:19 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 12:55:50 26/12/2023 12:56:03 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 12:55:50 26/12/2023 12:56:08 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 12:55:43 26/12/2023 12:55:52 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 12:55:43 26/12/2023 12:55:58 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 11:55:31 26/12/2023 11:55:47 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 11:55:31 26/12/2023 11:55:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 11:55:24 26/12/2023 11:55:37 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 11:55:24 26/12/2023 11:55:42 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 11:55:17 26/12/2023 11:55:26 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 11:55:17 26/12/2023 11:55:31 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 10:55:05 26/12/2023 10:55:22 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 10:55:05 26/12/2023 10:55:27 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 10:54:58 26/12/2023 10:55:10 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 10:54:58 26/12/2023 10:55:16 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 10:54:51 26/12/2023 10:55:00 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 10:54:51 26/12/2023 10:55:05 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 09:54:38 26/12/2023 09:55:01 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 09:54:38 26/12/2023 09:55:06 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 09:54:32 26/12/2023 09:54:50 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 09:54:32 26/12/2023 09:54:55 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 09:54:25 26/12/2023 09:54:33 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 09:54:25 26/12/2023 09:54:44 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 08:54:12 26/12/2023 08:54:35 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 08:54:12 26/12/2023 08:54:40 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 08:54:06 26/12/2023 08:54:24 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 08:54:06 26/12/2023 08:54:29 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 08:53:59 26/12/2023 08:54:07 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 08:53:59 26/12/2023 08:54:18 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 07:53:46 26/12/2023 07:54:03 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 07:53:46 26/12/2023 07:54:08 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 07:53:39 26/12/2023 07:53:52 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 07:53:39 26/12/2023 07:53:57 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 07:53:32 26/12/2023 07:53:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 07:53:32 26/12/2023 07:53:46 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 06:53:20 26/12/2023 06:53:37 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 06:53:20 26/12/2023 06:53:42 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 06:53:13 26/12/2023 06:53:26 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 06:53:13 26/12/2023 06:53:31 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 06:53:06 26/12/2023 06:53:15 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 06:53:06 26/12/2023 06:53:20 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 05:52:53 26/12/2023 05:53:11 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 05:52:53 26/12/2023 05:53:16 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 05:52:47 26/12/2023 05:53:00 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 05:52:47 26/12/2023 05:53:06 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 05:52:40 26/12/2023 05:52:49 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 05:52:40 26/12/2023 05:52:54 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 04:52:27 26/12/2023 04:52:50 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 04:52:27 26/12/2023 04:52:56 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 04:52:21 26/12/2023 04:52:39 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 04:52:21 26/12/2023 04:52:45 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 04:52:14 26/12/2023 04:52:23 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 04:52:14 26/12/2023 04:52:33 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 03:52:01 26/12/2023 03:52:24 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 03:51:54 26/12/2023 03:52:19 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 03:51:54 26/12/2023 03:52:35 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 03:51:48 26/12/2023 03:51:56 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 03:51:48 26/12/2023 03:52:13 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 02:51:37 26/12/2023 02:51:52 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 02:51:30 26/12/2023 02:51:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 02:51:23 26/12/2023 02:51:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 01:51:11 26/12/2023 02:05:43 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 01:51:04 26/12/2023 02:05:48 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 01:50:57 26/12/2023 02:05:54 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 01:49:55 26/12/2023 02:05:59 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 26/12/2023 01:49:55 26/12/2023 02:06:05 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 01:49:55 27/12/2023 00:00:56 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 26/12/2023 01:49:48 26/12/2023 02:06:10 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 01:49:42 26/12/2023 02:06:16 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 26/12/2023 01:49:42 26/12/2023 02:06:21 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 26/12/2023 01:49:42 27/12/2023 00:01:13 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 26/12/2023 01:49:36 26/12/2023 02:06:27 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 26/12/2023 01:49:36 26/12/2023 02:06:32 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 26/12/2023 01:49:36 26/12/2023 02:06:37 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 01:49:35 26/12/2023 02:06:43 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 26/12/2023 01:44:30 26/12/2023 01:54:52 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 26/12/2023 01:44:30 26/12/2023 01:54:57 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 01:44:30 26/12/2023 01:55:03 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 26/12/2023 01:39:47 26/12/2023 01:40:26 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 26/12/2023 01:39:47 26/12/2023 01:40:42 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 26/12/2023 01:39:26 26/12/2023 01:40:20 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 26/12/2023 01:39:26 26/12/2023 01:40:37 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 26/12/2023 01:39:25 26/12/2023 01:39:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 01:39:25 26/12/2023 01:40:04 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 26/12/2023 01:39:24 26/12/2023 01:39:47 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 26/12/2023 01:39:15 26/12/2023 01:39:25 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 26/12/2023 01:39:15 26/12/2023 01:39:31 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 26/12/2023 01:39:07 26/12/2023 01:39:14 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 26/12/2023 01:39:07 26/12/2023 01:40:09 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 26/12/2023 01:39:07 26/12/2023 01:40:15 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 26/12/2023 01:34:19 26/12/2023 01:34:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 01:34:19 26/12/2023 01:34:36 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 01:34:19 26/12/2023 01:34:41 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 26/12/2023 01:34:19 26/12/2023 01:34:47 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 26/12/2023 01:34:19 26/12/2023 01:39:20 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 26/12/2023 01:34:19 26/12/2023 01:39:36 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 01:34:19 26/12/2023 01:39:58 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 26/12/2023 00:34:06 26/12/2023 00:34:27 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 00:34:06 26/12/2023 00:34:32 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 00:33:59 26/12/2023 00:34:16 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 00:33:59 26/12/2023 00:34:21 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 00:33:53 26/12/2023 00:33:59 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 26/12/2023 00:33:53 26/12/2023 00:34:10 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 23:33:40 25/12/2023 23:33:55 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 23:33:40 25/12/2023 23:34:00 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 23:33:33 25/12/2023 23:33:44 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 23:33:33 25/12/2023 23:33:49 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 23:33:26 25/12/2023 23:33:33 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 23:33:26 25/12/2023 23:33:38 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 22:33:13 25/12/2023 22:33:29 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 22:33:13 25/12/2023 22:33:35 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 22:33:07 25/12/2023 22:33:18 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 22:33:07 25/12/2023 22:33:24 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 22:33:00 25/12/2023 22:33:07 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 22:33:00 25/12/2023 22:33:13 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 22:12:21 25/12/2023 22:12:21 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/12/2023 21:32:48 25/12/2023 21:33:03 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 21:32:48 25/12/2023 21:33:08 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 21:32:41 25/12/2023 21:32:52 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 21:32:41 25/12/2023 21:32:57 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 21:32:34 25/12/2023 21:32:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 21:32:34 25/12/2023 21:32:46 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 20:32:21 25/12/2023 20:32:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 20:32:21 25/12/2023 20:32:47 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 20:32:15 25/12/2023 20:32:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 20:32:15 25/12/2023 20:32:36 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 20:32:08 25/12/2023 20:32:14 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 20:32:08 25/12/2023 20:32:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 19:31:55 25/12/2023 19:32:16 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 19:31:55 25/12/2023 19:32:21 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 19:31:48 25/12/2023 19:32:05 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 19:31:48 25/12/2023 19:32:10 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 19:31:41 25/12/2023 19:31:48 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 19:31:41 25/12/2023 19:31:59 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 18:31:29 25/12/2023 18:31:44 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 18:31:29 25/12/2023 18:31:50 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 18:31:22 25/12/2023 18:31:33 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 18:31:22 25/12/2023 18:31:39 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 18:31:16 25/12/2023 18:31:22 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 18:31:16 25/12/2023 18:31:28 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 17:31:03 25/12/2023 17:31:19 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 17:31:03 25/12/2023 17:31:24 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 17:30:56 25/12/2023 17:31:07 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 17:30:56 25/12/2023 17:31:13 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 17:30:49 25/12/2023 17:30:58 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 17:30:49 25/12/2023 17:31:02 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 16:30:36 25/12/2023 16:30:52 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 16:30:36 25/12/2023 16:30:57 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 16:30:30 25/12/2023 16:30:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 16:30:30 25/12/2023 16:30:46 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 16:30:23 25/12/2023 16:30:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 16:30:23 25/12/2023 16:30:35 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 15:30:10 25/12/2023 15:30:31 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 15:30:10 25/12/2023 15:30:36 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 15:30:04 25/12/2023 15:30:20 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 15:30:04 25/12/2023 15:30:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 15:29:57 25/12/2023 15:30:03 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 15:29:57 25/12/2023 15:30:14 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 14:29:44 25/12/2023 14:30:05 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 14:29:44 25/12/2023 14:30:11 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 14:29:37 25/12/2023 14:29:54 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 14:29:37 25/12/2023 14:30:00 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 14:29:31 25/12/2023 14:29:37 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 14:29:31 25/12/2023 14:29:49 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 13:29:18 25/12/2023 13:29:39 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 13:29:18 25/12/2023 13:29:44 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 13:29:11 25/12/2023 13:29:28 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 13:29:11 25/12/2023 13:29:34 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 13:29:05 25/12/2023 13:29:11 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 13:29:05 25/12/2023 13:29:22 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 12:28:52 25/12/2023 12:29:07 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 12:28:52 25/12/2023 12:29:12 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 12:28:45 25/12/2023 12:28:56 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 12:28:45 25/12/2023 12:29:02 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 12:28:38 25/12/2023 12:28:45 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 12:28:38 25/12/2023 12:28:51 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 11:28:26 25/12/2023 11:28:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 11:28:26 25/12/2023 11:28:47 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 11:28:19 25/12/2023 11:28:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 11:28:19 25/12/2023 11:28:36 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 11:28:12 25/12/2023 11:28:19 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 11:28:12 25/12/2023 11:28:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 10:27:59 25/12/2023 10:28:22 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 10:27:59 25/12/2023 10:28:28 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 10:27:53 25/12/2023 10:28:11 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 10:27:53 25/12/2023 10:28:17 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 10:27:46 25/12/2023 10:27:55 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 10:27:46 25/12/2023 10:28:06 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 10:26:44 25/12/2023 10:50:47 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 25/12/2023 10:26:44 25/12/2023 10:50:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 10:26:44 26/12/2023 01:34:58 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 25/12/2023 10:26:24 25/12/2023 10:51:04 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 25/12/2023 10:26:24 25/12/2023 10:51:09 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 25/12/2023 10:26:24 25/12/2023 10:51:15 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 25/12/2023 10:26:24 25/12/2023 10:51:20 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 10:26:24 25/12/2023 10:51:26 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 25/12/2023 10:26:24 25/12/2023 10:51:31 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 25/12/2023 10:26:24 26/12/2023 01:34:52 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 25/12/2023 10:21:19 25/12/2023 10:39:02 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 25/12/2023 10:21:19 25/12/2023 10:39:07 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 10:21:19 25/12/2023 10:39:13 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 25/12/2023 10:16:13 25/12/2023 10:17:22 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 10:16:13 25/12/2023 10:17:28 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 25/12/2023 10:16:06 25/12/2023 10:16:55 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 25/12/2023 10:16:01 25/12/2023 10:16:38 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 25/12/2023 10:16:00 25/12/2023 10:16:27 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 25/12/2023 10:16:00 25/12/2023 10:16:44 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 25/12/2023 10:15:57 25/12/2023 10:16:16 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 25/12/2023 10:15:57 25/12/2023 10:16:33 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 25/12/2023 10:15:53 25/12/2023 10:16:00 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 25/12/2023 10:15:53 25/12/2023 10:16:05 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 25/12/2023 10:15:53 25/12/2023 10:16:22 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 25/12/2023 10:11:08 25/12/2023 10:11:15 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 25/12/2023 10:11:08 25/12/2023 10:11:26 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 25/12/2023 10:11:08 25/12/2023 10:11:31 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 25/12/2023 10:11:08 25/12/2023 10:16:11 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 25/12/2023 10:11:08 25/12/2023 10:17:06 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 22:12:22 24/12/2023 22:12:22 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/12/2023 20:05:13 24/12/2023 20:05:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 20:05:06 24/12/2023 20:05:19 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 20:05:06 24/12/2023 20:05:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 20:05:00 24/12/2023 20:05:08 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 20:05:00 24/12/2023 20:05:14 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 19:04:47 24/12/2023 19:05:10 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 19:04:47 24/12/2023 19:05:15 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 19:04:40 24/12/2023 19:04:58 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 19:04:40 24/12/2023 19:05:04 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 19:04:34 24/12/2023 19:04:42 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 19:04:34 24/12/2023 19:04:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 18:04:21 24/12/2023 18:04:38 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 18:04:14 24/12/2023 18:04:32 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 18:04:14 24/12/2023 18:04:44 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 18:04:07 24/12/2023 18:04:16 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 18:04:07 24/12/2023 18:04:27 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 17:03:55 24/12/2023 17:04:17 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 17:03:48 24/12/2023 17:04:06 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 17:03:48 24/12/2023 17:04:12 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 17:03:41 24/12/2023 17:03:49 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 17:03:41 24/12/2023 17:04:00 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 17:02:39 24/12/2023 17:03:22 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 17:02:33 24/12/2023 17:03:27 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 17:02:32 24/12/2023 17:03:33 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 17:02:26 24/12/2023 17:03:38 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 17:02:20 24/12/2023 17:03:44 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 24/12/2023 17:02:20 24/12/2023 17:04:33 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 24/12/2023 17:02:19 24/12/2023 17:04:39 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 24/12/2023 17:02:19 24/12/2023 17:04:44 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 17:02:19 24/12/2023 17:04:55 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 17:02:19 24/12/2023 17:05:01 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 24/12/2023 17:02:19 24/12/2023 17:05:07 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 24/12/2023 16:57:14 24/12/2023 17:22:24 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 16:57:14 24/12/2023 17:22:29 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 16:57:13 24/12/2023 17:22:35 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 16:54:49 24/12/2023 16:55:22 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 16:54:49 24/12/2023 16:55:38 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 16:54:45 24/12/2023 16:55:11 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 16:54:45 24/12/2023 16:55:27 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 16:54:44 24/12/2023 16:55:00 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 16:54:44 24/12/2023 16:55:16 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 16:54:41 24/12/2023 16:54:49 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 16:54:41 24/12/2023 16:55:05 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 16:52:08 24/12/2023 16:52:16 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 16:52:08 24/12/2023 16:52:27 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 16:52:08 24/12/2023 16:52:33 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 16:52:08 24/12/2023 16:52:44 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 16:52:08 24/12/2023 16:54:54 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 15:51:55 24/12/2023 15:52:12 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 15:51:55 24/12/2023 15:52:18 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 15:51:48 24/12/2023 15:52:01 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 15:51:48 24/12/2023 15:52:07 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 15:51:42 24/12/2023 15:51:50 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 15:51:42 24/12/2023 15:51:56 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 14:51:29 24/12/2023 14:51:51 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 14:51:29 24/12/2023 14:51:57 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 14:51:22 24/12/2023 14:51:40 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 14:51:22 24/12/2023 14:51:46 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 14:51:15 24/12/2023 14:51:23 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 14:51:15 24/12/2023 14:51:34 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 13:51:03 24/12/2023 13:51:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 13:51:03 24/12/2023 13:51:31 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 13:50:56 24/12/2023 13:51:14 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 13:50:56 24/12/2023 13:51:20 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 13:50:49 24/12/2023 13:50:58 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 13:50:49 24/12/2023 13:51:09 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 12:50:36 24/12/2023 12:50:54 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 12:50:36 24/12/2023 12:50:59 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 12:50:30 24/12/2023 12:50:43 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 12:50:30 24/12/2023 12:50:48 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 12:50:23 24/12/2023 12:50:32 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 12:50:23 24/12/2023 12:50:37 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 11:50:10 24/12/2023 11:50:27 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 11:50:10 24/12/2023 11:50:33 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 11:50:04 24/12/2023 11:50:16 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 11:50:04 24/12/2023 11:50:22 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 11:49:57 24/12/2023 11:50:05 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 11:49:57 24/12/2023 11:50:11 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 10:49:31 24/12/2023 10:49:51 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 10:48:29 24/12/2023 10:49:34 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 10:48:29 24/12/2023 10:49:40 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 10:48:22 24/12/2023 10:49:12 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 10:48:22 24/12/2023 10:49:18 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 10:48:22 24/12/2023 10:49:29 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 10:48:22 24/12/2023 16:52:22 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 10:48:15 24/12/2023 10:48:50 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 10:48:15 24/12/2023 10:49:01 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 10:48:10 24/12/2023 10:48:23 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 24/12/2023 10:48:10 24/12/2023 10:48:28 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 24/12/2023 10:48:10 24/12/2023 10:48:45 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 24/12/2023 10:48:10 24/12/2023 10:49:07 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 24/12/2023 10:48:09 24/12/2023 10:48:39 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 10:48:09 24/12/2023 10:51:21 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 24/12/2023 10:48:09 24/12/2023 16:52:38 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 24/12/2023 10:48:08 24/12/2023 10:48:34 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 10:48:08 24/12/2023 10:48:56 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 24/12/2023 10:48:08 24/12/2023 10:49:23 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 24/12/2023 10:43:03 24/12/2023 11:08:53 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 10:43:03 24/12/2023 11:08:59 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 10:43:03 24/12/2023 11:09:04 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 10:40:45 24/12/2023 10:41:26 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 10:40:44 24/12/2023 10:41:15 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 10:40:40 24/12/2023 10:41:04 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 10:40:34 24/12/2023 10:40:47 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 10:40:34 24/12/2023 10:40:53 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 10:40:34 24/12/2023 11:14:57 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 10:37:58 24/12/2023 10:38:22 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 10:37:57 24/12/2023 10:38:11 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 10:37:57 24/12/2023 11:15:03 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 10:37:57 24/12/2023 11:15:08 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 05:34:38 24/12/2023 10:38:06 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 05:34:38 24/12/2023 10:38:17 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 05:34:38 24/12/2023 10:38:33 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 05:34:38 24/12/2023 10:48:17 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 05:34:31 24/12/2023 10:38:44 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 05:34:25 24/12/2023 10:38:50 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 24/12/2023 05:34:25 24/12/2023 10:38:55 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 24/12/2023 05:34:24 24/12/2023 10:38:28 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 24/12/2023 05:34:24 24/12/2023 10:39:01 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 24/12/2023 05:34:23 24/12/2023 10:39:06 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 05:34:23 24/12/2023 10:39:12 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 05:34:23 24/12/2023 10:39:17 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 24/12/2023 05:34:23 24/12/2023 10:39:23 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 24/12/2023 05:34:16 24/12/2023 10:39:28 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 05:34:14 24/12/2023 10:39:39 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 05:34:12 24/12/2023 10:39:45 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 05:34:11 24/12/2023 10:39:51 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 05:29:18 24/12/2023 05:29:46 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 05:29:18 24/12/2023 05:29:57 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 05:29:18 24/12/2023 05:30:02 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 05:27:25 24/12/2023 05:28:12 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 05:27:24 24/12/2023 05:27:55 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 05:27:24 24/12/2023 05:28:01 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 05:27:23 24/12/2023 05:27:44 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 05:27:20 24/12/2023 05:27:33 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 05:27:20 24/12/2023 05:27:50 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 05:27:08 24/12/2023 05:27:17 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 05:27:08 24/12/2023 05:27:28 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 05:27:08 24/12/2023 05:27:39 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 05:27:08 24/12/2023 05:30:08 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 24/12/2023 05:24:13 24/12/2023 05:24:31 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 05:24:13 24/12/2023 05:24:37 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 05:24:13 24/12/2023 05:27:22 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 05:24:13 24/12/2023 05:29:29 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 05:24:12 24/12/2023 05:24:20 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 05:24:12 24/12/2023 05:24:48 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 05:24:12 24/12/2023 05:29:51 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 24/12/2023 04:23:59 24/12/2023 04:24:16 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 04:23:59 24/12/2023 04:24:22 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 04:23:52 24/12/2023 04:24:05 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 04:23:52 24/12/2023 04:24:11 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 04:23:46 24/12/2023 04:23:54 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 04:23:46 24/12/2023 04:24:00 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 03:23:32 24/12/2023 03:23:58 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 03:23:32 24/12/2023 03:24:03 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 03:23:25 24/12/2023 03:23:47 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 03:23:25 24/12/2023 03:23:52 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 03:23:18 24/12/2023 03:23:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 03:23:18 24/12/2023 03:23:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 02:23:06 24/12/2023 02:23:29 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 02:23:06 24/12/2023 02:23:35 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 02:22:59 24/12/2023 02:23:18 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 02:22:59 24/12/2023 02:23:24 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 02:22:52 24/12/2023 02:23:02 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 02:22:52 24/12/2023 02:23:13 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 01:22:39 24/12/2023 01:23:04 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 01:22:39 24/12/2023 01:23:11 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 01:22:33 24/12/2023 01:22:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 01:22:33 24/12/2023 01:22:58 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 01:22:26 24/12/2023 01:22:36 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 01:22:26 24/12/2023 01:22:47 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 00:22:13 24/12/2023 00:22:37 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 00:22:13 24/12/2023 00:22:43 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 00:22:07 24/12/2023 00:22:26 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 00:22:07 24/12/2023 00:22:32 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 00:22:00 24/12/2023 00:22:10 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/12/2023 00:22:00 24/12/2023 00:22:21 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 23:21:47 23/12/2023 23:22:11 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 23:21:47 23/12/2023 23:22:17 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 23:21:40 23/12/2023 23:22:00 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 23:21:40 23/12/2023 23:22:06 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 23:21:33 23/12/2023 23:21:43 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 23:21:33 23/12/2023 23:21:54 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 23:20:32 23/12/2023 23:44:49 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 23:20:25 23/12/2023 23:44:54 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 23:20:12 23/12/2023 23:45:11 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 23/12/2023 23:20:12 23/12/2023 23:45:16 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 23/12/2023 23:20:11 23/12/2023 23:45:22 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 23/12/2023 23:20:11 23/12/2023 23:45:27 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 23:20:10 23/12/2023 23:21:26 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 23:20:10 23/12/2023 23:21:32 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 23:20:10 23/12/2023 23:21:38 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 23/12/2023 23:20:10 23/12/2023 23:45:33 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 23:15:05 23/12/2023 23:38:21 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 23:15:05 23/12/2023 23:38:26 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 23:15:05 23/12/2023 23:38:32 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 23:13:27 23/12/2023 23:13:58 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 23:13:27 23/12/2023 23:14:14 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 23:13:25 23/12/2023 23:13:46 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 23:13:25 23/12/2023 23:14:03 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 23:13:24 23/12/2023 23:13:35 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 23:13:24 23/12/2023 23:13:52 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 23:13:09 23/12/2023 23:13:19 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 23:13:09 23/12/2023 23:13:30 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 23:13:09 23/12/2023 23:13:41 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 23:13:09 23/12/2023 23:44:26 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 23:10:00 23/12/2023 23:10:31 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 23:10:00 23/12/2023 23:13:25 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 23:09:59 23/12/2023 23:10:09 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 23:09:59 23/12/2023 23:10:14 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 23:09:59 23/12/2023 23:10:20 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 23:09:59 23/12/2023 23:44:32 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 23:09:59 23/12/2023 23:44:38 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 23:09:59 23/12/2023 23:44:43 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 22:12:24 23/12/2023 22:12:24 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/12/2023 22:09:46 23/12/2023 22:10:10 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 22:09:46 23/12/2023 22:10:15 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 22:09:40 23/12/2023 22:09:59 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 22:09:40 23/12/2023 22:10:04 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 22:09:33 23/12/2023 22:09:42 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 22:09:33 23/12/2023 22:09:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 21:09:20 23/12/2023 21:09:44 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 21:09:20 23/12/2023 21:09:50 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 21:09:13 23/12/2023 21:09:33 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 21:09:13 23/12/2023 21:09:39 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 21:09:07 23/12/2023 21:09:16 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 21:09:07 23/12/2023 21:09:28 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 20:08:54 23/12/2023 20:09:18 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 20:08:54 23/12/2023 20:09:23 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 20:08:47 23/12/2023 20:09:07 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 20:08:47 23/12/2023 20:09:12 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 20:08:40 23/12/2023 20:08:50 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 20:08:40 23/12/2023 20:09:01 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 19:08:28 23/12/2023 19:08:46 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 19:08:28 23/12/2023 19:08:52 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 19:08:21 23/12/2023 19:08:35 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 19:08:21 23/12/2023 19:08:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 19:08:14 23/12/2023 19:08:24 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 19:08:14 23/12/2023 19:08:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 18:08:02 23/12/2023 18:33:00 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 18:07:55 23/12/2023 18:33:06 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 18:07:48 23/12/2023 18:33:11 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 18:06:40 23/12/2023 18:08:24 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 18:06:40 23/12/2023 18:08:29 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 18:06:40 23/12/2023 23:10:26 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 18:06:33 23/12/2023 18:08:02 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 18:06:33 23/12/2023 18:08:18 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 18:06:27 23/12/2023 18:07:34 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 23/12/2023 18:06:27 23/12/2023 18:07:40 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 23/12/2023 18:06:27 23/12/2023 18:07:56 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 23/12/2023 18:06:27 23/12/2023 18:08:13 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 23/12/2023 18:06:26 23/12/2023 18:06:44 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 23/12/2023 18:06:26 23/12/2023 18:06:50 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 18:06:26 23/12/2023 18:06:55 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 18:06:26 23/12/2023 18:07:01 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 18:06:26 23/12/2023 18:07:12 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 18:06:26 23/12/2023 18:07:45 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 18:06:26 23/12/2023 18:07:51 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 18:06:26 23/12/2023 18:08:07 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 18:06:26 23/12/2023 18:33:28 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 23/12/2023 18:06:26 23/12/2023 23:10:37 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 18:01:21 23/12/2023 18:07:18 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 18:01:20 23/12/2023 18:07:07 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 18:01:20 23/12/2023 18:22:19 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 17:58:31 23/12/2023 17:59:05 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 17:58:29 23/12/2023 17:58:43 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 17:58:29 23/12/2023 17:58:49 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 17:58:17 23/12/2023 17:58:27 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 17:58:16 23/12/2023 17:58:32 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 17:57:57 23/12/2023 17:58:21 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 17:57:55 23/12/2023 17:58:05 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 17:57:55 23/12/2023 17:58:10 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 17:56:15 23/12/2023 17:56:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 17:56:15 23/12/2023 17:56:30 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 17:56:15 23/12/2023 17:56:36 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 17:56:15 23/12/2023 17:56:41 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 17:56:15 23/12/2023 17:58:16 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 17:56:15 23/12/2023 18:07:29 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 16:56:02 23/12/2023 16:56:31 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 16:56:02 23/12/2023 16:56:36 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 16:55:55 23/12/2023 16:56:20 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 16:55:55 23/12/2023 16:56:26 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 16:55:48 23/12/2023 16:55:58 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 16:55:48 23/12/2023 16:56:15 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 15:55:36 23/12/2023 15:56:00 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 15:55:36 23/12/2023 15:56:05 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 15:55:29 23/12/2023 15:55:48 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 15:55:29 23/12/2023 15:55:54 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 15:55:22 23/12/2023 15:55:32 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 15:55:22 23/12/2023 15:55:43 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 14:55:10 23/12/2023 14:55:37 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 14:55:10 23/12/2023 14:55:42 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 14:55:03 23/12/2023 14:55:26 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 14:55:03 23/12/2023 14:55:31 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 14:54:56 23/12/2023 14:55:09 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 14:54:56 23/12/2023 14:55:20 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 14:53:55 23/12/2023 15:18:10 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 14:53:55 23/12/2023 17:56:47 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 14:53:54 23/12/2023 15:18:21 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 14:53:35 23/12/2023 14:54:37 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 23/12/2023 14:53:35 23/12/2023 15:18:38 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 23/12/2023 14:53:34 23/12/2023 14:54:42 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 23/12/2023 14:53:33 23/12/2023 14:54:47 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 14:53:33 23/12/2023 14:54:53 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 14:53:33 23/12/2023 14:54:58 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 14:53:33 23/12/2023 14:55:04 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 23/12/2023 14:53:33 23/12/2023 14:55:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 14:53:33 23/12/2023 17:56:53 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 14:48:28 23/12/2023 14:49:39 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 14:48:28 23/12/2023 14:49:45 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 14:48:28 23/12/2023 14:49:56 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 14:48:28 23/12/2023 15:12:02 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 14:48:28 23/12/2023 15:12:08 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 14:48:28 23/12/2023 15:12:13 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 14:46:36 23/12/2023 14:47:27 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 14:46:34 23/12/2023 14:47:11 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 14:46:34 23/12/2023 14:47:16 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 14:46:32 23/12/2023 14:47:00 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 14:46:30 23/12/2023 14:46:49 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 14:46:30 23/12/2023 14:47:05 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 14:46:23 23/12/2023 14:46:33 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 14:46:23 23/12/2023 14:46:38 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 14:46:23 23/12/2023 14:46:54 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 14:46:23 23/12/2023 14:50:01 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 14:43:23 23/12/2023 14:43:43 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 14:43:23 23/12/2023 14:43:48 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 14:43:23 23/12/2023 14:46:44 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 14:43:23 23/12/2023 14:49:23 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 14:43:22 23/12/2023 14:43:32 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 14:43:22 23/12/2023 14:43:59 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 14:43:22 23/12/2023 14:49:50 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 14:43:22 23/12/2023 15:18:05 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 13:43:09 23/12/2023 13:43:33 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 13:43:09 23/12/2023 13:43:38 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 13:43:02 23/12/2023 13:43:22 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 13:43:02 23/12/2023 13:43:27 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 13:42:56 23/12/2023 13:43:06 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 13:42:56 23/12/2023 13:43:16 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 12:42:43 23/12/2023 12:43:01 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 12:42:43 23/12/2023 12:43:07 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 12:42:36 23/12/2023 12:42:50 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 12:42:36 23/12/2023 12:42:56 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 12:42:29 23/12/2023 12:42:39 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 12:42:29 23/12/2023 12:42:45 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 11:42:17 23/12/2023 11:42:42 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 11:42:17 23/12/2023 11:42:48 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 11:42:10 23/12/2023 11:42:31 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 11:42:10 23/12/2023 11:42:36 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 11:42:03 23/12/2023 11:42:14 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 11:42:03 23/12/2023 11:42:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 10:41:44 23/12/2023 10:42:03 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 10:41:44 23/12/2023 10:42:09 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 10:41:37 23/12/2023 10:41:47 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 10:41:37 23/12/2023 10:41:58 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 10:40:35 23/12/2023 10:41:03 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 10:40:35 23/12/2023 10:41:08 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 10:40:29 23/12/2023 10:40:40 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 10:40:29 23/12/2023 10:40:46 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 10:40:29 23/12/2023 10:40:57 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 10:40:29 23/12/2023 14:43:37 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 10:40:16 23/12/2023 11:07:08 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 23/12/2023 10:40:16 23/12/2023 11:07:13 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 23/12/2023 10:40:15 23/12/2023 11:07:19 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 23/12/2023 10:40:15 23/12/2023 11:07:24 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 10:40:15 23/12/2023 11:07:30 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 10:40:15 23/12/2023 11:07:36 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 10:40:15 23/12/2023 14:43:54 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 10:40:14 23/12/2023 10:40:52 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 23/12/2023 10:40:14 23/12/2023 11:07:41 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 10:35:09 23/12/2023 10:57:27 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 10:35:09 23/12/2023 10:57:33 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 10:35:09 23/12/2023 10:57:38 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 10:32:16 23/12/2023 10:32:41 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 10:32:14 23/12/2023 10:32:35 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 10:31:40 23/12/2023 10:32:13 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 10:31:39 23/12/2023 10:32:07 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 10:31:39 23/12/2023 10:32:19 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 10:31:37 23/12/2023 10:31:56 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 10:31:29 23/12/2023 10:31:39 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 10:31:29 23/12/2023 10:31:45 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 10:31:29 23/12/2023 10:32:02 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 10:30:04 23/12/2023 10:30:21 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 10:30:04 23/12/2023 10:30:41 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 10:30:04 23/12/2023 10:31:50 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 10:30:04 23/12/2023 10:36:28 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 10:30:03 23/12/2023 10:30:13 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 10:30:03 23/12/2023 10:30:25 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 10:30:03 23/12/2023 10:38:32 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 10:30:03 23/12/2023 10:41:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 09:29:51 23/12/2023 09:30:11 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 09:29:51 23/12/2023 09:30:16 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 09:29:44 23/12/2023 09:29:59 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 09:29:44 23/12/2023 09:30:05 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 09:29:37 23/12/2023 09:29:47 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 09:29:37 23/12/2023 09:29:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 08:29:24 23/12/2023 08:29:51 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 08:29:24 23/12/2023 08:29:57 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 08:29:18 23/12/2023 08:29:40 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 08:29:18 23/12/2023 08:29:46 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 08:29:11 23/12/2023 08:29:24 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 08:29:11 23/12/2023 08:29:35 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 08:28:09 23/12/2023 08:29:13 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 08:28:03 23/12/2023 08:29:18 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 08:28:03 23/12/2023 10:30:30 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 08:28:02 23/12/2023 08:30:09 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 08:27:50 23/12/2023 08:30:24 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 23/12/2023 08:27:50 23/12/2023 08:30:30 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 23/12/2023 08:27:48 23/12/2023 08:30:35 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 23/12/2023 08:27:48 23/12/2023 08:30:41 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 08:27:48 23/12/2023 08:30:47 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 08:27:48 23/12/2023 10:30:36 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 08:27:47 23/12/2023 08:30:52 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 23/12/2023 08:27:47 23/12/2023 08:30:58 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 23/12/2023 08:27:47 23/12/2023 08:31:03 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 08:27:47 23/12/2023 08:31:09 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 08:27:46 23/12/2023 08:31:14 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 08:22:42 23/12/2023 08:47:48 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 08:22:41 23/12/2023 08:47:53 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 08:22:41 23/12/2023 08:47:59 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 08:21:04 23/12/2023 08:21:39 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 08:21:04 23/12/2023 08:21:55 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 08:21:03 23/12/2023 08:21:28 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 08:21:03 23/12/2023 08:21:44 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 08:20:57 23/12/2023 08:21:17 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 08:20:57 23/12/2023 08:21:33 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 08:20:56 23/12/2023 08:21:06 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 08:20:56 23/12/2023 08:21:22 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 08:20:56 23/12/2023 08:53:27 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 08:17:36 23/12/2023 08:17:51 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 08:17:36 23/12/2023 08:17:56 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 08:17:36 23/12/2023 08:18:02 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 08:17:36 23/12/2023 08:21:11 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 08:17:36 23/12/2023 08:53:32 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 08:17:36 23/12/2023 08:53:38 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 08:17:35 23/12/2023 08:17:45 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 07:17:23 23/12/2023 07:17:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 07:17:23 23/12/2023 07:17:46 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 07:17:16 23/12/2023 07:17:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 07:17:16 23/12/2023 07:17:35 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 07:17:09 23/12/2023 07:17:19 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 07:17:09 23/12/2023 07:17:24 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 06:16:56 23/12/2023 06:17:21 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 06:16:49 23/12/2023 06:17:09 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 06:16:43 23/12/2023 06:16:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 05:16:30 23/12/2023 05:42:26 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 05:16:23 23/12/2023 05:42:32 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 05:16:17 23/12/2023 05:42:37 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 05:15:15 23/12/2023 05:42:43 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 05:15:08 23/12/2023 05:42:48 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 05:15:08 23/12/2023 08:18:13 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 05:14:56 23/12/2023 05:43:05 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 23/12/2023 05:14:55 23/12/2023 05:43:10 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 23/12/2023 05:14:55 23/12/2023 05:43:16 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 05:14:55 23/12/2023 05:43:21 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 05:14:55 23/12/2023 05:43:27 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 05:14:55 23/12/2023 08:18:08 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 05:14:54 23/12/2023 05:43:32 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 05:14:54 23/12/2023 05:43:38 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 23/12/2023 05:09:49 23/12/2023 05:30:57 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 05:09:49 23/12/2023 05:31:02 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 05:09:49 23/12/2023 05:31:08 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 05:04:44 23/12/2023 05:06:24 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 05:04:43 23/12/2023 05:06:14 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 05:03:07 23/12/2023 05:03:50 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 05:03:07 23/12/2023 05:04:07 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 05:03:05 23/12/2023 05:03:39 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 05:03:05 23/12/2023 05:03:56 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 05:03:02 23/12/2023 05:03:28 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 05:03:02 23/12/2023 05:03:33 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 05:03:01 23/12/2023 05:03:11 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 05:03:01 23/12/2023 05:03:17 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 05:03:01 23/12/2023 05:03:44 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 04:59:38 23/12/2023 04:59:48 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 04:59:38 23/12/2023 04:59:53 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 04:59:38 23/12/2023 04:59:59 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 04:59:38 23/12/2023 05:00:04 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 04:59:38 23/12/2023 05:03:22 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 04:59:38 23/12/2023 05:05:52 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 04:59:38 23/12/2023 05:06:19 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 04:59:38 23/12/2023 05:26:26 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 03:59:25 23/12/2023 03:59:43 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 03:59:25 23/12/2023 03:59:49 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 03:59:18 23/12/2023 03:59:33 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 03:59:18 23/12/2023 03:59:38 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 03:59:11 23/12/2023 03:59:22 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 03:59:11 23/12/2023 03:59:27 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 02:59:00 23/12/2023 02:59:17 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 02:59:00 23/12/2023 02:59:23 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 02:58:53 23/12/2023 02:59:07 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 02:58:53 23/12/2023 02:59:12 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 02:58:47 23/12/2023 02:58:56 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 02:58:47 23/12/2023 02:59:01 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 01:58:34 23/12/2023 01:58:58 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 01:58:34 23/12/2023 01:59:03 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 01:58:27 23/12/2023 01:58:47 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 01:58:27 23/12/2023 01:58:52 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 01:58:20 23/12/2023 01:58:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 01:58:20 23/12/2023 01:58:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 01:57:18 23/12/2023 02:07:31 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 01:57:12 23/12/2023 02:07:36 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 01:57:12 23/12/2023 02:07:42 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 01:57:12 23/12/2023 05:00:15 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 01:56:59 23/12/2023 02:07:53 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 23/12/2023 01:56:59 23/12/2023 02:07:59 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 23/12/2023 01:56:58 23/12/2023 02:08:10 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 23/12/2023 01:56:58 23/12/2023 02:08:16 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 01:56:58 23/12/2023 02:08:21 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 01:56:58 23/12/2023 02:08:27 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 01:56:58 23/12/2023 02:08:32 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 01:56:58 23/12/2023 05:00:10 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 23/12/2023 01:56:57 23/12/2023 02:08:38 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 23/12/2023 01:51:52 23/12/2023 02:25:48 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 01:51:52 23/12/2023 02:25:54 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 01:46:46 23/12/2023 02:13:46 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 01:46:27 23/12/2023 01:46:55 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 01:46:27 23/12/2023 01:47:12 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 01:46:26 23/12/2023 01:46:39 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 01:46:26 23/12/2023 01:47:01 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 01:46:25 23/12/2023 01:46:33 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 01:46:25 23/12/2023 01:46:44 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 01:46:05 23/12/2023 01:46:14 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 23/12/2023 01:46:05 23/12/2023 01:46:20 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 01:46:05 23/12/2023 01:46:50 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 01:41:42 23/12/2023 01:42:22 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 01:41:42 23/12/2023 01:46:25 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 01:41:41 23/12/2023 01:41:50 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 01:41:41 23/12/2023 01:42:06 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 23/12/2023 01:41:41 23/12/2023 01:42:11 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 00:41:28 23/12/2023 00:41:51 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 00:41:28 23/12/2023 00:41:56 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 00:41:21 23/12/2023 00:41:40 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 00:41:21 23/12/2023 00:41:46 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 00:41:15 23/12/2023 00:41:24 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/12/2023 00:41:15 23/12/2023 00:41:35 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 23:41:02 22/12/2023 23:41:19 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 23:41:02 22/12/2023 23:41:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 23:40:55 22/12/2023 23:41:08 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 23:40:55 22/12/2023 23:41:14 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 23:40:48 22/12/2023 23:40:57 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 23:40:48 22/12/2023 23:41:03 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 22:40:36 22/12/2023 22:56:46 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 22:40:29 22/12/2023 22:56:52 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 22:40:22 22/12/2023 22:56:57 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 22:39:20 22/12/2023 22:57:03 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 22:39:14 22/12/2023 22:57:08 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 22:39:14 23/12/2023 01:42:17 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 22:39:01 22/12/2023 22:40:54 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 22:39:01 22/12/2023 22:57:25 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 22/12/2023 22:39:01 22/12/2023 22:57:31 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 22:39:00 22/12/2023 22:40:37 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 22:39:00 23/12/2023 01:42:28 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 22:38:59 22/12/2023 22:39:53 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 22:38:59 22/12/2023 22:40:04 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 22:38:59 22/12/2023 22:40:09 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 22:38:59 22/12/2023 22:40:26 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 22:38:59 22/12/2023 22:40:32 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 22/12/2023 22:38:59 22/12/2023 22:40:43 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 22/12/2023 22:38:59 22/12/2023 22:57:36 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 22:38:59 22/12/2023 22:57:42 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 22:38:59 22/12/2023 22:57:47 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 22:38:59 22/12/2023 22:57:53 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 22:33:54 22/12/2023 22:40:15 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 22:33:53 22/12/2023 22:39:37 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 22:33:53 22/12/2023 22:39:58 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 22:29:17 22/12/2023 22:30:20 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 22:29:13 22/12/2023 22:29:58 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 22:29:12 22/12/2023 22:29:47 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 22:29:12 22/12/2023 22:30:03 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 22:28:49 22/12/2023 22:29:41 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 22:28:49 22/12/2023 22:29:52 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 22:28:48 22/12/2023 22:29:08 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 22:28:48 22/12/2023 22:29:14 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 22:28:48 22/12/2023 22:29:25 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 22:28:48 22/12/2023 22:56:24 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 22:28:48 22/12/2023 22:56:35 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 22:28:48 22/12/2023 22:56:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 22:28:37 22/12/2023 22:28:46 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 22:28:37 22/12/2023 22:29:30 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 22:28:37 22/12/2023 22:29:36 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 22:23:43 22/12/2023 22:24:13 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 22:23:43 22/12/2023 22:28:52 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 22:23:42 22/12/2023 22:23:51 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 22:23:42 22/12/2023 22:23:56 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 22:23:42 22/12/2023 22:24:02 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 22:23:42 22/12/2023 22:28:57 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 22:23:42 22/12/2023 22:29:20 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 22:23:42 22/12/2023 22:40:48 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 22:12:26 22/12/2023 22:12:26 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/12/2023 21:23:29 22/12/2023 21:23:47 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 21:23:29 22/12/2023 21:23:52 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 21:23:23 22/12/2023 21:23:36 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 21:23:23 22/12/2023 21:23:41 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 21:23:16 22/12/2023 21:23:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 21:23:16 22/12/2023 21:23:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 21:10:06 22/12/2023 21:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/12/2023 20:23:03 22/12/2023 20:23:26 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 20:23:03 22/12/2023 20:23:32 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 20:22:56 22/12/2023 20:23:15 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 20:22:56 22/12/2023 20:23:21 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 20:22:50 22/12/2023 20:22:59 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 20:22:50 22/12/2023 20:23:10 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 19:22:37 22/12/2023 19:40:28 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 19:22:30 22/12/2023 19:40:34 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 19:22:23 22/12/2023 19:40:40 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 19:21:15 22/12/2023 19:22:54 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 19:21:15 22/12/2023 19:23:00 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 19:21:15 22/12/2023 22:24:07 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 19:21:08 22/12/2023 19:22:32 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 19:21:08 22/12/2023 19:22:44 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 19:21:02 22/12/2023 19:22:05 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 19:21:02 22/12/2023 19:22:10 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 22/12/2023 19:21:02 22/12/2023 19:22:27 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 22/12/2023 19:21:02 22/12/2023 19:22:49 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 19:21:01 22/12/2023 19:21:25 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 19:21:01 22/12/2023 19:21:42 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 22/12/2023 19:21:01 22/12/2023 19:21:48 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 19:21:01 22/12/2023 19:21:53 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 22/12/2023 19:21:01 22/12/2023 19:22:21 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 19:21:01 22/12/2023 22:24:18 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 19:21:00 22/12/2023 19:21:14 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 19:21:00 22/12/2023 19:22:16 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 19:21:00 22/12/2023 19:22:38 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 19:21:00 22/12/2023 19:23:06 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 19:15:55 22/12/2023 19:21:20 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 19:15:55 22/12/2023 19:21:31 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 19:15:55 22/12/2023 19:31:06 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 19:10:53 22/12/2023 19:11:55 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 19:10:52 22/12/2023 19:11:38 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 19:10:51 22/12/2023 19:11:00 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 19:05:44 22/12/2023 19:11:22 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 19:02:52 22/12/2023 19:04:41 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 19:02:48 22/12/2023 19:04:30 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 19:02:47 22/12/2023 19:04:19 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 19:02:46 22/12/2023 19:04:02 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 19:02:45 22/12/2023 19:03:57 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 19:00:40 22/12/2023 19:00:49 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 18:55:33 22/12/2023 19:01:05 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 18:50:28 22/12/2023 18:50:42 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 18:45:23 22/12/2023 19:01:16 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 18:40:17 22/12/2023 18:40:31 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 18:35:12 22/12/2023 18:35:34 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 18:35:12 22/12/2023 18:35:40 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 18:25:01 22/12/2023 18:25:30 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 18:25:01 22/12/2023 18:31:14 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 18:21:24 22/12/2023 18:21:38 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 18:20:55 22/12/2023 18:21:05 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 18:19:57 22/12/2023 18:20:48 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 18:19:56 22/12/2023 18:20:15 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 18:19:56 22/12/2023 18:20:26 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 18:19:56 22/12/2023 18:20:32 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 18:19:38 22/12/2023 18:19:48 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 18:14:52 22/12/2023 18:20:21 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 18:14:51 22/12/2023 18:20:04 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 18:09:47 22/12/2023 18:10:29 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 18:09:46 22/12/2023 18:10:24 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 18:09:45 22/12/2023 18:10:01 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 18:09:45 22/12/2023 18:10:06 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 18:09:45 22/12/2023 18:10:34 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 18:09:45 22/12/2023 18:15:00 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 18:05:42 22/12/2023 16:03:57 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 22/12/2023 18:05:42 22/12/2023 16:03:44 43475587 43475587 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 22/12/2023 18:04:49 22/12/2023 16:02:51 43475587 43475587 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 22/12/2023 18:04:42 22/12/2023 18:10:12 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 18:04:40 22/12/2023 18:09:50 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 18:04:40 22/12/2023 18:20:37 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 17:59:35 22/12/2023 18:00:23 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 17:59:34 22/12/2023 18:00:06 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 17:59:34 22/12/2023 18:00:17 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 17:59:34 22/12/2023 18:04:44 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 17:54:29 22/12/2023 18:00:12 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 17:51:08 22/12/2023 18:03:49 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 17:51:07 22/12/2023 18:03:54 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 17:51:04 22/12/2023 18:04:05 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 17:51:02 22/12/2023 18:04:11 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 17:51:00 22/12/2023 18:04:16 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 17:49:24 22/12/2023 17:59:55 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 17:44:19 22/12/2023 18:00:29 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 17:44:19 22/12/2023 18:21:27 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 17:44:18 22/12/2023 18:21:32 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 17:12:19 22/12/2023 17:12:36 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 17:12:16 22/12/2023 17:12:25 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 17:11:45 22/12/2023 17:11:55 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 17:08:42 22/12/2023 17:09:35 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 17:08:42 22/12/2023 17:09:40 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 17:08:41 22/12/2023 17:09:02 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 17:08:41 22/12/2023 17:09:13 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 17:08:41 22/12/2023 17:09:19 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 17:08:41 22/12/2023 17:09:46 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 17:08:36 22/12/2023 17:09:24 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 17:08:36 22/12/2023 17:09:30 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 17:03:48 22/12/2023 16:04:24 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 22/12/2023 17:03:36 22/12/2023 17:04:00 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 17:03:36 22/12/2023 17:04:11 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 17:03:36 22/12/2023 17:08:51 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 17:03:36 22/12/2023 17:09:07 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 17:03:35 22/12/2023 17:03:49 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 17:03:35 22/12/2023 17:10:02 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 17:03:34 22/12/2023 18:02:09 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 17:03:34 22/12/2023 19:21:59 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 16:03:44 22/12/2023 16:03:56 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 16:03:44 22/12/2023 16:04:02 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 16:03:44 22/12/2023 17:03:55 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 16:03:44 22/12/2023 17:04:05 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 16:00:56 22/12/2023 16:02:29 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 15:49:40 22/12/2023 15:50:15 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 15:49:20 22/12/2023 17:03:44 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 15:49:19 22/12/2023 17:04:16 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 15:49:18 22/12/2023 17:08:45 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 15:47:47 22/12/2023 15:49:36 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 15:47:46 22/12/2023 15:49:20 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 15:47:44 22/12/2023 15:49:03 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 15:47:38 22/12/2023 15:49:14 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 15:43:00 22/12/2023 15:49:42 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 15:37:25 22/12/2023 15:38:40 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 15:37:24 22/12/2023 15:38:34 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 15:37:23 22/12/2023 15:38:18 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 15:37:22 22/12/2023 15:38:12 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 15:37:21 22/12/2023 15:37:56 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 15:19:08 22/12/2023 15:19:33 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 15:19:08 22/12/2023 15:19:44 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 15:14:03 22/12/2023 15:19:50 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 15:08:59 22/12/2023 15:09:32 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 15:08:57 22/12/2023 15:09:10 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 15:08:57 22/12/2023 15:09:37 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 15:03:54 22/12/2023 15:04:23 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 15:03:54 22/12/2023 15:09:15 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 15:03:52 22/12/2023 15:04:00 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 15:03:52 22/12/2023 15:04:28 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 14:58:49 22/12/2023 14:59:09 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 14:58:49 22/12/2023 15:04:06 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 14:53:41 22/12/2023 14:53:54 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 14:53:41 22/12/2023 14:59:14 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 14:48:36 22/12/2023 14:48:45 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 14:48:36 22/12/2023 14:49:12 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 14:48:36 22/12/2023 14:49:18 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 14:41:30 22/12/2023 14:49:07 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 14:41:28 22/12/2023 14:49:29 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 14:41:27 22/12/2023 14:49:45 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 14:41:08 22/12/2023 14:49:01 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 14:40:46 22/12/2023 14:48:56 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 14:38:26 22/12/2023 14:38:51 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 14:36:40 22/12/2023 14:38:24 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 14:36:39 22/12/2023 14:38:12 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 14:36:38 22/12/2023 14:38:01 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 14:36:35 22/12/2023 14:37:56 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 14:33:20 22/12/2023 14:48:50 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 14:33:20 22/12/2023 14:49:23 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 14:18:04 22/12/2023 14:18:14 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 14:12:59 22/12/2023 14:18:36 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 14:07:55 22/12/2023 14:08:40 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 14:07:54 22/12/2023 14:08:18 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 14:07:53 22/12/2023 14:08:07 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 14:07:53 22/12/2023 14:08:45 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 14:02:49 22/12/2023 14:03:14 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 14:02:49 22/12/2023 14:08:12 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 13:57:43 22/12/2023 13:58:04 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 13:57:43 22/12/2023 14:08:23 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 13:57:42 22/12/2023 13:57:53 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 13:57:42 22/12/2023 14:02:58 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 13:52:37 22/12/2023 13:57:59 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 13:52:37 22/12/2023 13:58:10 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 13:47:33 22/12/2023 13:48:24 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 13:47:32 22/12/2023 13:47:40 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 13:47:32 22/12/2023 13:47:51 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 13:47:23 22/12/2023 13:47:35 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 13:47:23 22/12/2023 13:48:02 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 13:47:14 22/12/2023 13:47:24 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 13:46:36 22/12/2023 13:46:45 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 13:46:36 22/12/2023 13:47:29 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 13:42:28 22/12/2023 13:43:09 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 13:42:28 22/12/2023 13:47:46 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 13:42:27 22/12/2023 13:42:58 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 13:42:27 22/12/2023 13:47:57 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 13:42:26 22/12/2023 13:42:47 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 13:42:26 22/12/2023 13:43:15 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 13:42:21 22/12/2023 13:42:31 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 13:42:21 22/12/2023 13:42:36 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 13:42:21 22/12/2023 13:43:04 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 13:42:21 22/12/2023 13:46:51 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 13:37:21 22/12/2023 13:37:30 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 13:37:21 22/12/2023 13:37:48 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 13:37:21 22/12/2023 13:42:42 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 13:37:21 22/12/2023 13:42:53 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 11:35:20 22/12/2023 12:02:20 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 11:35:20 22/12/2023 13:37:36 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 11:35:07 22/12/2023 12:02:25 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 22/12/2023 11:35:07 22/12/2023 12:02:31 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 11:35:07 22/12/2023 12:02:36 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 11:35:06 22/12/2023 12:02:42 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 22/12/2023 11:35:05 22/12/2023 12:02:47 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 11:35:05 22/12/2023 12:02:53 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 22/12/2023 11:35:05 22/12/2023 12:02:58 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 11:35:05 22/12/2023 13:37:42 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 11:35:04 22/12/2023 12:03:04 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 11:35:04 22/12/2023 12:03:15 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 11:35:03 22/12/2023 12:03:21 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 11:34:33 22/12/2023 11:37:33 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 11:34:32 22/12/2023 11:37:38 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 11:34:31 22/12/2023 11:37:43 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 11:34:30 22/12/2023 11:37:49 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 11:34:29 22/12/2023 11:37:55 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 11:32:14 22/12/2023 11:33:18 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 11:32:12 22/12/2023 11:33:07 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 11:32:11 22/12/2023 11:32:45 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 11:32:05 22/12/2023 11:32:34 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 11:29:59 22/12/2023 11:30:27 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 11:29:59 22/12/2023 11:53:58 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 11:29:58 22/12/2023 11:30:10 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 11:29:58 22/12/2023 11:30:21 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 10:59:26 22/12/2023 10:59:37 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 10:59:26 22/12/2023 10:59:43 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 10:59:26 22/12/2023 11:30:16 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 10:59:26 22/12/2023 11:30:32 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 10:49:16 22/12/2023 10:49:25 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 10:49:16 22/12/2023 10:49:36 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 10:49:16 22/12/2023 10:59:48 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 10:44:11 22/12/2023 10:49:58 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 10:44:10 22/12/2023 10:49:30 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 10:39:05 22/12/2023 10:39:20 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 10:39:05 22/12/2023 10:39:26 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 10:37:05 22/12/2023 10:38:08 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 10:37:03 22/12/2023 10:37:52 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 10:37:02 22/12/2023 10:37:41 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 10:37:00 22/12/2023 10:37:29 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 10:36:49 22/12/2023 10:37:57 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 10:32:54 22/12/2023 10:33:08 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 10:31:05 22/12/2023 10:32:52 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 10:31:04 22/12/2023 10:32:41 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 10:31:03 22/12/2023 10:32:24 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 10:03:27 22/12/2023 10:08:44 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 09:58:22 22/12/2023 09:58:32 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 09:58:22 22/12/2023 10:39:37 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 09:37:36 22/12/2023 09:38:11 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 09:37:32 22/12/2023 09:38:00 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 09:37:31 22/12/2023 09:37:49 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 09:35:41 22/12/2023 09:37:27 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 09:32:55 22/12/2023 09:58:38 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 09:31:35 22/12/2023 09:33:12 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 09:31:33 22/12/2023 09:32:51 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 09:31:32 22/12/2023 09:32:39 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 09:31:31 22/12/2023 09:32:28 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 09:31:30 22/12/2023 09:32:17 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 09:29:21 22/12/2023 09:37:38 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 08:40:10 22/12/2023 08:40:38 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 08:40:10 22/12/2023 08:40:55 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 08:40:08 22/12/2023 08:40:28 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 08:40:08 22/12/2023 08:40:33 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 08:40:07 22/12/2023 08:40:17 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 08:40:07 22/12/2023 08:40:22 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 08:36:58 22/12/2023 08:37:28 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 08:36:58 22/12/2023 08:37:34 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 08:36:58 22/12/2023 08:40:44 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 08:36:57 22/12/2023 08:37:17 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 08:36:56 22/12/2023 08:37:06 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 08:36:56 22/12/2023 08:37:39 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 08:31:51 22/12/2023 08:32:00 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 08:31:51 22/12/2023 08:32:17 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 08:31:51 22/12/2023 08:37:11 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 08:31:51 22/12/2023 08:37:22 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 05:29:30 22/12/2023 05:30:45 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 05:29:30 22/12/2023 08:32:12 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 05:29:11 22/12/2023 05:30:01 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 05:29:11 22/12/2023 05:30:07 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 05:29:11 22/12/2023 05:30:12 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 22/12/2023 05:29:11 22/12/2023 05:30:23 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 05:29:11 22/12/2023 05:30:29 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 22/12/2023 05:29:11 22/12/2023 05:30:40 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 05:29:10 22/12/2023 05:29:50 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 22/12/2023 05:29:10 22/12/2023 05:29:56 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 22/12/2023 05:29:09 22/12/2023 05:29:23 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 05:29:09 22/12/2023 05:29:39 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 22/12/2023 05:29:09 22/12/2023 05:29:45 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 22/12/2023 05:29:09 22/12/2023 05:30:34 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 05:29:09 22/12/2023 08:32:06 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 05:29:08 22/12/2023 05:30:18 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 05:29:08 22/12/2023 05:30:51 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 05:24:03 22/12/2023 05:29:28 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 05:24:03 22/12/2023 05:36:10 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 05:18:58 22/12/2023 05:19:22 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 05:18:57 22/12/2023 05:19:12 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 05:13:52 22/12/2023 05:19:17 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 05:13:52 22/12/2023 05:19:28 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 05:10:49 22/12/2023 05:11:15 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 05:10:49 22/12/2023 05:11:32 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 05:10:45 22/12/2023 05:11:04 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 05:10:45 22/12/2023 05:11:26 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 05:10:43 22/12/2023 05:10:53 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 05:10:43 22/12/2023 05:11:09 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 05:08:48 22/12/2023 05:09:18 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 05:08:48 22/12/2023 05:09:24 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 05:08:48 22/12/2023 05:10:58 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 05:08:47 22/12/2023 05:08:56 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 05:08:47 22/12/2023 05:09:07 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 05:08:47 22/12/2023 05:09:29 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 05:03:41 22/12/2023 05:03:51 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 05:03:41 22/12/2023 05:03:56 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 05:03:41 22/12/2023 05:09:02 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 05:03:41 22/12/2023 05:09:13 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 02:02:22 22/12/2023 02:02:39 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 02:02:22 22/12/2023 05:04:02 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 02:01:00 22/12/2023 02:01:32 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 02:01:00 22/12/2023 02:01:37 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 02:01:00 22/12/2023 02:01:55 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 02:01:00 22/12/2023 02:02:00 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 02:01:00 22/12/2023 02:02:06 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 22/12/2023 02:01:00 22/12/2023 02:02:11 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 02:01:00 22/12/2023 02:02:17 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/12/2023 02:01:00 22/12/2023 02:02:22 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 22/12/2023 02:01:00 22/12/2023 02:02:33 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 02:01:00 22/12/2023 05:04:07 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 02:00:59 22/12/2023 02:01:21 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 22/12/2023 02:00:59 22/12/2023 02:01:26 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 22/12/2023 02:00:58 22/12/2023 02:01:10 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 02:00:58 22/12/2023 02:01:15 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 02:00:58 22/12/2023 02:02:28 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 22/12/2023 02:00:58 22/12/2023 02:02:45 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 22/12/2023 01:55:53 22/12/2023 02:01:43 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 01:55:53 22/12/2023 02:17:35 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 01:51:31 22/12/2023 01:51:57 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 01:51:31 22/12/2023 01:52:14 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 01:51:28 22/12/2023 01:51:46 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 01:51:28 22/12/2023 01:52:03 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 01:51:26 22/12/2023 01:51:35 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 01:51:26 22/12/2023 01:51:52 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 01:50:49 22/12/2023 01:51:20 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 01:50:49 22/12/2023 01:51:41 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 01:50:48 22/12/2023 01:50:58 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 01:50:48 22/12/2023 01:51:09 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 22/12/2023 01:45:43 22/12/2023 01:46:04 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 01:45:43 22/12/2023 01:51:14 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 01:45:42 22/12/2023 01:45:52 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 22/12/2023 01:45:42 22/12/2023 01:51:03 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 21:42:55 22/12/2023 01:45:58 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 21:42:39 21/12/2023 21:44:09 43475587 43475587 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 21/12/2023 21:42:39 21/12/2023 21:44:15 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 21/12/2023 21:42:39 21/12/2023 21:44:20 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 21/12/2023 21:42:38 21/12/2023 21:44:26 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 21/12/2023 21:42:37 21/12/2023 21:44:31 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 21/12/2023 21:42:37 21/12/2023 21:44:37 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 21/12/2023 21:42:37 21/12/2023 21:44:42 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 21/12/2023 21:42:37 22/12/2023 01:46:09 43475587 43475587 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 21/12/2023 21:42:36 21/12/2023 21:44:48 43475587 43475587 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 21/12/2023 21:42:36 21/12/2023 21:44:53 43475587 43475587 1,0 1072 Elevator Failure Energy saving failure
KRM_SERVER 21/12/2023 21:42:36 21/12/2023 21:44:59 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 21:39:50 21/12/2023 21:53:14 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 21:27:20 21/12/2023 21:27:40 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 21:27:20 21/12/2023 21:28:08 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 21:22:14 21/12/2023 21:22:24 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 21:22:14 21/12/2023 21:22:57 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 21:22:14 21/12/2023 21:23:02 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 21:17:10 21/12/2023 21:17:35 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 21:17:10 21/12/2023 21:22:40 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 21:17:09 21/12/2023 21:17:19 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 21:17:09 21/12/2023 21:17:46 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 21:12:04 21/12/2023 21:12:24 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 21:12:04 21/12/2023 21:12:35 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 21:12:03 21/12/2023 21:12:13 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 21:12:03 21/12/2023 21:12:52 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 21:09:56 21/12/2023 21:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/12/2023 21:06:59 21/12/2023 21:07:30 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 21:06:59 21/12/2023 21:07:41 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 21:06:59 21/12/2023 21:07:52 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 21:06:59 21/12/2023 21:12:19 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 21:06:59 21/12/2023 21:12:30 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 21:06:59 21/12/2023 21:27:57 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 21:06:58 21/12/2023 21:07:08 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 21:06:58 21/12/2023 21:07:19 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 21:06:58 21/12/2023 21:08:03 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 21:01:52 21/12/2023 21:02:03 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 21:01:52 21/12/2023 21:07:13 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:56:47 21/12/2023 20:56:57 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:56:47 21/12/2023 21:02:08 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:46:37 21/12/2023 20:46:58 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:46:37 21/12/2023 21:02:19 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:46:36 21/12/2023 20:46:47 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:46:36 21/12/2023 20:57:03 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:41:32 21/12/2023 20:41:52 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:41:32 21/12/2023 20:47:03 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:41:31 21/12/2023 20:41:47 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:41:31 21/12/2023 20:46:52 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:36:26 21/12/2023 20:36:47 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:36:26 21/12/2023 20:41:58 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:31:21 21/12/2023 20:31:41 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:31:21 21/12/2023 20:36:52 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:15:59 21/12/2023 20:16:09 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:15:59 21/12/2023 20:21:14 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:15:00 21/12/2023 20:15:16 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:15:00 21/12/2023 20:15:32 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:13:47 21/12/2023 20:13:57 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:13:47 21/12/2023 20:14:42 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:04:32 21/12/2023 20:04:59 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 21/12/2023 20:04:28 21/12/2023 20:04:48 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:04:28 21/12/2023 20:04:54 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:04:28 21/12/2023 20:05:05 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 20:04:28 21/12/2023 20:09:43 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 19:41:28 21/12/2023 19:41:44 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 21/12/2023 19:41:28 21/12/2023 20:04:37 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 21/12/2023 19:41:23 21/12/2023 19:41:33 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 19:41:23 21/12/2023 19:41:39 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 19:41:23 21/12/2023 19:43:10 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 19:41:23 21/12/2023 19:46:39 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 19:32:42 21/12/2023 19:32:57 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 19:32:42 21/12/2023 19:37:58 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 19:25:05 21/12/2023 19:25:18 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 19:25:05 21/12/2023 19:30:21 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 19:06:06 21/12/2023 19:06:27 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 19:06:06 21/12/2023 19:11:06 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 19:01:08 21/12/2023 19:01:18 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 19:01:08 21/12/2023 19:01:24 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 19:01:08 21/12/2023 19:05:43 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 18:51:53 21/12/2023 18:52:16 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 18:51:53 21/12/2023 18:55:37 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 18:46:43 21/12/2023 18:46:54 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 18:46:43 21/12/2023 18:51:59 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 18:38:34 21/12/2023 18:38:50 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 18:38:34 21/12/2023 18:38:55 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 18:35:10 21/12/2023 18:35:31 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 18:35:10 21/12/2023 18:37:31 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 18:30:05 21/12/2023 18:35:20 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 18:19:54 21/12/2023 18:20:04 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 18:14:49 21/12/2023 18:15:10 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 18:14:49 21/12/2023 18:20:10 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 18:04:38 21/12/2023 18:04:59 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 18:04:38 21/12/2023 18:15:15 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 17:59:32 21/12/2023 17:59:48 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 17:59:32 21/12/2023 18:05:05 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 17:44:16 21/12/2023 17:44:26 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 17:44:16 21/12/2023 17:44:37 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 17:44:16 21/12/2023 17:59:53 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 17:39:12 21/12/2023 17:39:43 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 17:39:12 21/12/2023 17:44:32 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 17:39:11 21/12/2023 17:39:21 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 17:39:11 21/12/2023 17:39:38 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 17:34:07 21/12/2023 17:34:55 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 17:34:07 21/12/2023 17:39:27 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 17:34:06 21/12/2023 17:44:43 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 17:34:05 21/12/2023 17:34:16 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 17:34:05 21/12/2023 17:34:49 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 17:29:01 21/12/2023 17:29:38 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 17:29:01 21/12/2023 17:34:21 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 17:29:01 21/12/2023 17:34:38 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 17:13:44 21/12/2023 17:13:55 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 17:13:44 21/12/2023 17:14:23 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 17:08:39 21/12/2023 17:08:54 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 17:08:39 21/12/2023 17:09:21 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 17:03:34 21/12/2023 17:03:57 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 17:03:34 21/12/2023 17:29:27 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 17:03:33 21/12/2023 17:03:46 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 17:03:33 21/12/2023 17:04:25 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 16:58:28 21/12/2023 16:58:39 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 16:58:28 21/12/2023 16:58:50 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 16:58:28 21/12/2023 16:58:56 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:58:28 21/12/2023 16:59:17 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:58:28 21/12/2023 16:59:23 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 16:58:28 21/12/2023 17:04:03 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 16:53:23 21/12/2023 16:53:43 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:53:23 21/12/2023 16:59:01 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:53:22 21/12/2023 16:53:32 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 16:53:22 21/12/2023 16:53:59 43475587 43475587 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 21/12/2023 16:48:17 21/12/2023 16:48:37 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:48:17 21/12/2023 16:53:48 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:44:35 21/12/2023 16:44:45 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:44:35 21/12/2023 16:48:32 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:43:12 21/12/2023 16:43:34 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:43:12 21/12/2023 16:43:39 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:43:12 21/12/2023 16:43:45 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:43:12 21/12/2023 16:48:43 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:42:50 21/12/2023 16:43:01 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:42:50 21/12/2023 16:43:18 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:42:45 21/12/2023 16:42:56 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:42:45 21/12/2023 16:43:12 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:32:10 21/12/2023 16:32:20 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:32:10 21/12/2023 16:32:31 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:30:52 21/12/2023 16:31:02 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 16:30:52 21/12/2023 16:31:07 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 14:25:11 21/12/2023 14:25:21 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 14:25:11 21/12/2023 14:25:42 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 10:12:14 21/12/2023 10:12:45 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 10:12:14 21/12/2023 10:12:50 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 10:12:14 21/12/2023 10:12:55 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 10:12:14 21/12/2023 10:13:06 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 10:11:38 21/12/2023 10:11:52 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 10:11:38 21/12/2023 10:12:28 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 10:11:36 21/12/2023 10:11:47 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 10:11:36 21/12/2023 10:12:23 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 09:35:05 21/12/2023 09:35:15 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 09:35:05 21/12/2023 09:35:29 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 09:34:33 21/12/2023 09:34:43 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 09:34:33 21/12/2023 09:34:54 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 09:05:47 21/12/2023 09:06:13 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 21/12/2023 09:05:47 21/12/2023 09:06:35 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 21/12/2023 09:04:50 21/12/2023 09:05:13 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 21/12/2023 09:04:50 21/12/2023 09:07:14 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 21/12/2023 09:01:38 21/12/2023 09:02:30 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 09:01:28 21/12/2023 09:01:51 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 21/12/2023 09:01:28 21/12/2023 09:02:13 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 21/12/2023 09:01:26 21/12/2023 09:01:45 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 09:01:26 21/12/2023 09:02:02 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 09:00:34 21/12/2023 09:01:29 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 09:00:19 21/12/2023 09:00:50 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 21/12/2023 09:00:19 21/12/2023 09:01:12 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 21/12/2023 09:00:16 21/12/2023 09:00:44 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 09:00:16 21/12/2023 09:01:00 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 08:59:31 21/12/2023 09:00:11 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 08:59:31 21/12/2023 09:00:22 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 08:59:15 21/12/2023 08:59:32 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 21/12/2023 08:59:15 21/12/2023 08:59:54 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 21/12/2023 08:59:14 21/12/2023 08:59:27 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 08:59:14 21/12/2023 08:59:43 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 08:49:22 21/12/2023 08:49:32 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 08:49:22 21/12/2023 08:49:52 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 08:48:55 21/12/2023 08:49:05 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 08:48:55 21/12/2023 08:49:17 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 08:46:02 21/12/2023 08:46:13 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 08:46:02 21/12/2023 08:46:22 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 08:35:26 21/12/2023 08:35:37 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 08:35:26 21/12/2023 08:35:57 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 08:26:17 21/12/2023 08:26:28 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 21/12/2023 08:26:17 21/12/2023 08:26:38 43475587 43475587 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 20/12/2023 21:09:34 20/12/2023 21:09:34 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/12/2023 21:09:47 19/12/2023 21:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/12/2023 21:09:37 18/12/2023 21:09:37 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/12/2023 10:22:36 18/12/2023 10:22:44 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/12/2023 10:22:36 18/12/2023 10:23:07 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/12/2023 21:10:52 17/12/2023 21:10:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/12/2023 21:10:54 16/12/2023 21:10:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/12/2023 21:09:41 15/12/2023 21:09:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/12/2023 21:09:49 14/12/2023 21:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/12/2023 21:09:45 13/12/2023 21:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/12/2023 21:09:47 12/12/2023 21:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/12/2023 21:10:27 11/12/2023 21:10:27 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/12/2023 21:11:26 10/12/2023 21:11:26 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/12/2023 21:09:52 09/12/2023 21:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/12/2023 21:09:53 08/12/2023 21:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/12/2023 21:09:55 07/12/2023 21:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/12/2023 09:42:33 07/12/2023 09:42:33 43475587 43475587 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 07/12/2023 09:40:50 07/12/2023 09:41:50 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/12/2023 21:10:08 06/12/2023 21:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/12/2023 21:09:59 05/12/2023 21:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/12/2023 21:10:12 04/12/2023 21:10:12 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/12/2023 21:10:02 03/12/2023 21:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/12/2023 21:10:12 02/12/2023 21:10:12 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/12/2023 21:10:05 01/12/2023 21:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/11/2023 21:09:33 30/11/2023 21:09:33 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/11/2023 21:09:34 29/11/2023 21:09:34 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/11/2023 21:09:45 28/11/2023 21:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/11/2023 21:09:46 27/11/2023 21:09:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/11/2023 21:09:49 26/11/2023 21:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/11/2023 21:09:41 25/11/2023 21:09:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/11/2023 10:52:19 25/11/2023 10:52:26 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/11/2023 10:52:19 25/11/2023 10:54:36 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/11/2023 21:09:52 24/11/2023 21:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/11/2023 21:10:13 23/11/2023 21:10:13 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/11/2023 21:11:59 22/11/2023 21:11:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/11/2023 21:09:49 21/11/2023 21:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/11/2023 21:09:49 20/11/2023 21:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/11/2023 21:09:51 19/11/2023 21:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/11/2023 21:10:05 18/11/2023 21:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/11/2023 07:32:43 18/11/2023 07:32:48 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/11/2023 07:32:43 18/11/2023 07:34:25 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/11/2023 21:10:02 17/11/2023 21:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/11/2023 21:09:56 16/11/2023 21:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/11/2023 12:12:31 16/11/2023 12:12:36 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 16/11/2023 12:12:31 16/11/2023 12:13:32 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 15/11/2023 21:09:57 15/11/2023 21:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/11/2023 21:10:07 14/11/2023 21:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/11/2023 21:10:09 13/11/2023 21:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/11/2023 19:41:32 13/11/2023 19:41:39 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 13/11/2023 19:41:32 13/11/2023 19:41:45 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 13/11/2023 19:41:32 13/11/2023 19:41:56 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 13/11/2023 19:41:32 13/11/2023 19:42:02 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 13/11/2023 10:30:56 13/11/2023 10:31:03 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 13/11/2023 10:30:56 13/11/2023 10:32:06 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/11/2023 21:12:03 12/11/2023 21:12:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/11/2023 21:10:15 11/11/2023 21:10:15 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/11/2023 21:12:07 10/11/2023 21:12:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/11/2023 21:10:05 09/11/2023 21:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/11/2023 21:10:28 08/11/2023 21:10:28 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/11/2023 21:10:39 07/11/2023 21:10:39 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/11/2023 21:10:19 06/11/2023 21:10:19 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/11/2023 21:10:35 05/11/2023 21:10:35 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/11/2023 21:10:35 04/11/2023 21:10:35 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/11/2023 21:10:14 03/11/2023 21:10:14 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/11/2023 21:10:34 02/11/2023 21:10:34 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/11/2023 21:10:17 01/11/2023 21:10:17 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/10/2023 21:12:21 31/10/2023 21:12:21 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/10/2023 21:10:42 30/10/2023 21:10:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/10/2023 18:50:24 30/10/2023 18:50:36 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/10/2023 18:50:24 30/10/2023 18:50:52 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 29/10/2023 22:10:23 29/10/2023 22:10:23 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/10/2023 22:11:03 28/10/2023 22:11:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/10/2023 22:10:44 27/10/2023 22:10:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/10/2023 22:11:08 26/10/2023 22:11:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/10/2023 22:10:38 25/10/2023 22:10:38 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/10/2023 22:10:31 24/10/2023 22:10:31 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/10/2023 22:10:33 23/10/2023 22:10:33 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/10/2023 22:10:34 22/10/2023 22:10:34 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/10/2023 22:10:45 21/10/2023 22:10:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/10/2023 22:10:47 20/10/2023 22:10:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/10/2023 22:10:39 19/10/2023 22:10:39 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/10/2023 16:16:57 19/10/2023 16:17:07 43475587 43475587 1,0 2000 Elevator Failure Missing COP
KRM_SERVER 19/10/2023 16:16:57 19/10/2023 16:17:12 43475587 43475587 1,0 2000 Elevator Failure Missing COP
KRM_SERVER 19/10/2023 16:14:23 19/10/2023 16:14:27 43475587 43475587 1,0 2000 Elevator Failure Missing COP
KRM_SERVER 19/10/2023 16:14:23 19/10/2023 16:14:44 43475587 43475587 1,0 2000 Elevator Failure Missing COP
KRM_SERVER 19/10/2023 16:01:24 19/10/2023 16:01:28 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 19/10/2023 16:01:24 19/10/2023 16:01:50 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 19/10/2023 16:00:13 19/10/2023 16:00:17 43475587 43475587 1,0 2000 Elevator Failure Missing COP
KRM_SERVER 19/10/2023 15:52:27 19/10/2023 15:52:46 43475587 43475587 1,0 1010 Elevator Failure Safety circuit: blocking device (C4)
KRM_SERVER 19/10/2023 15:52:26 19/10/2023 15:52:51 43475587 43475587 1,0 1010 Elevator Failure Safety circuit: blocking device (C4)
KRM_SERVER 19/10/2023 15:51:59 19/10/2023 15:52:11 43475587 43475587 1,0 1010 Elevator Failure Safety circuit: blocking device (C4)
KRM_SERVER 19/10/2023 15:51:59 19/10/2023 15:52:34 43475587 43475587 1,0 1010 Elevator Failure Safety circuit: blocking device (C4)
KRM_SERVER 19/10/2023 15:47:36 19/10/2023 15:47:40 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 19/10/2023 15:46:49 19/10/2023 15:47:01 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 19/10/2023 15:45:33 19/10/2023 15:46:05 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 19/10/2023 15:45:26 19/10/2023 15:45:49 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 19/10/2023 15:45:26 19/10/2023 15:46:00 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 19/10/2023 15:45:26 19/10/2023 15:46:11 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 19/10/2023 15:45:23 19/10/2023 15:45:27 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 19/10/2023 15:45:23 19/10/2023 15:45:32 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 19/10/2023 15:45:23 19/10/2023 15:45:38 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 19/10/2023 15:45:23 19/10/2023 15:45:43 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 19/10/2023 14:25:46 19/10/2023 14:25:55 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 19/10/2023 14:25:46 19/10/2023 14:26:01 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 19/10/2023 14:13:01 19/10/2023 14:13:23 43475587 43475587 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 19/10/2023 14:13:01 19/10/2023 14:13:29 43475587 43475587 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 19/10/2023 14:06:59 19/10/2023 14:06:59 43475587 43475587 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 18/10/2023 22:10:50 18/10/2023 22:10:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/10/2023 22:10:47 17/10/2023 22:10:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/10/2023 22:10:52 16/10/2023 22:10:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/10/2023 22:11:00 15/10/2023 22:11:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/10/2023 15:59:02 15/10/2023 15:59:07 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 15/10/2023 15:59:02 15/10/2023 15:59:43 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 14/10/2023 22:10:46 14/10/2023 22:10:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/10/2023 22:11:05 13/10/2023 22:11:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/10/2023 22:10:52 12/10/2023 22:10:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/10/2023 22:10:51 11/10/2023 22:10:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/10/2023 22:11:05 10/10/2023 22:11:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/10/2023 07:58:01 10/10/2023 07:58:09 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/10/2023 07:58:01 10/10/2023 07:58:54 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/10/2023 22:10:54 09/10/2023 22:10:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/10/2023 22:10:56 08/10/2023 22:10:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/10/2023 22:11:07 07/10/2023 22:11:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/10/2023 22:10:59 06/10/2023 22:10:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/10/2023 22:11:14 05/10/2023 22:11:14 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/10/2023 22:11:02 04/10/2023 22:11:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/10/2023 22:11:03 03/10/2023 22:11:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/10/2023 22:11:06 02/10/2023 22:11:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/10/2023 22:11:29 01/10/2023 22:11:29 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/09/2023 22:12:33 30/09/2023 22:12:33 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/09/2023 17:00:24 30/09/2023 17:00:38 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/09/2023 17:00:24 30/09/2023 17:01:22 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 29/09/2023 17:32:40 29/09/2023 15:31:55 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 29/09/2023 17:31:42 29/09/2023 15:32:23 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 28/09/2023 22:09:01 28/09/2023 22:09:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/09/2023 22:09:03 27/09/2023 22:09:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/09/2023 12:28:26 27/09/2023 12:28:32 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/09/2023 12:28:26 27/09/2023 12:28:44 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 26/09/2023 22:09:04 26/09/2023 22:09:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/09/2023 22:09:07 25/09/2023 22:09:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/09/2023 16:44:15 25/09/2023 16:44:21 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/09/2023 16:44:15 25/09/2023 16:45:23 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/09/2023 22:09:17 24/09/2023 22:09:17 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/09/2023 22:11:31 23/09/2023 22:11:31 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/09/2023 22:09:52 22/09/2023 22:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/09/2023 22:09:22 21/09/2023 22:09:22 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/09/2023 07:10:01 21/09/2023 07:13:34 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/09/2023 07:10:01 21/09/2023 07:13:49 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/09/2023 22:09:39 20/09/2023 22:09:39 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/09/2023 22:09:16 19/09/2023 22:09:16 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/09/2023 22:09:51 18/09/2023 22:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/09/2023 22:09:36 17/09/2023 22:09:36 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/09/2023 22:09:21 16/09/2023 22:09:21 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/09/2023 22:10:19 15/09/2023 22:10:19 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/09/2023 22:09:24 14/09/2023 22:09:24 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/09/2023 22:09:56 13/09/2023 22:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/09/2023 22:09:27 12/09/2023 22:09:27 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/09/2023 22:09:32 11/09/2023 22:09:32 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/09/2023 22:09:58 10/09/2023 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/09/2023 22:09:44 09/09/2023 22:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/09/2023 22:10:09 08/09/2023 22:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/09/2023 22:11:58 07/09/2023 22:11:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/09/2023 22:10:02 06/09/2023 22:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/09/2023 12:21:39 06/09/2023 12:21:46 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/09/2023 12:21:39 06/09/2023 12:24:05 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 05/09/2023 22:09:56 05/09/2023 22:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/09/2023 22:10:34 04/09/2023 22:10:34 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/09/2023 22:10:35 03/09/2023 22:10:35 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/09/2023 22:10:29 02/09/2023 22:10:29 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/09/2023 22:09:58 01/09/2023 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/08/2023 22:10:09 31/08/2023 22:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/08/2023 22:11:48 30/08/2023 22:11:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/08/2023 22:10:11 29/08/2023 22:10:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/08/2023 22:10:24 28/08/2023 22:10:24 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/08/2023 22:09:57 27/08/2023 22:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/08/2023 18:28:31 27/08/2023 18:28:37 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/08/2023 18:28:31 27/08/2023 18:30:15 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 26/08/2023 22:10:20 26/08/2023 22:10:20 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/08/2023 22:09:55 25/08/2023 22:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/08/2023 22:10:00 24/08/2023 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/08/2023 22:10:50 23/08/2023 22:10:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/08/2023 15:22:18 23/08/2023 15:22:18 43475587 43475587 1,0 102 Temporary Fault Test Alarm
KRM_SERVER 22/08/2023 22:10:14 22/08/2023 22:10:14 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/08/2023 22:12:25 21/08/2023 22:12:25 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/08/2023 22:10:02 20/08/2023 22:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/08/2023 22:10:12 19/08/2023 22:10:12 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/08/2023 22:10:14 18/08/2023 22:10:14 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/08/2023 22:10:27 17/08/2023 22:10:27 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/08/2023 19:27:54 17/08/2023 17:28:01 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 17/08/2023 19:27:45 17/08/2023 17:28:14 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 17/08/2023 17:13:22 17/08/2023 17:13:38 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 17/08/2023 17:13:22 17/08/2023 17:13:44 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 17/08/2023 17:09:20 17/08/2023 17:09:38 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 17/08/2023 17:09:20 17/08/2023 17:13:21 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 17/08/2023 17:09:19 17/08/2023 17:09:32 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 17/08/2023 17:09:19 17/08/2023 17:13:15 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 17/08/2023 16:56:17 17/08/2023 16:56:36 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 17/08/2023 16:56:17 17/08/2023 16:56:41 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 17/08/2023 16:56:17 17/08/2023 16:56:47 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 17/08/2023 16:56:17 17/08/2023 16:56:53 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 17/08/2023 15:41:03 17/08/2023 15:41:11 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 17/08/2023 15:41:03 17/08/2023 15:41:17 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 17/08/2023 15:41:03 17/08/2023 15:41:22 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 17/08/2023 15:41:03 17/08/2023 15:41:28 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 16/08/2023 22:11:07 16/08/2023 22:11:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/08/2023 22:10:29 15/08/2023 22:10:29 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/08/2023 22:10:22 14/08/2023 22:10:22 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/08/2023 22:10:23 13/08/2023 22:10:23 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/08/2023 08:11:55 13/08/2023 08:12:00 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 13/08/2023 08:11:55 13/08/2023 08:14:48 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/08/2023 22:11:09 12/08/2023 22:11:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/08/2023 19:25:49 12/08/2023 19:25:54 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 12/08/2023 19:25:49 12/08/2023 19:26:00 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 12/08/2023 19:25:49 12/08/2023 19:26:05 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 12/08/2023 19:25:49 12/08/2023 19:26:11 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 11/08/2023 22:11:10 11/08/2023 22:11:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/08/2023 22:10:26 10/08/2023 22:10:26 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/08/2023 14:05:44 10/08/2023 12:06:11 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 10/08/2023 14:05:39 10/08/2023 12:05:58 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 10/08/2023 12:38:22 10/08/2023 10:38:08 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 10/08/2023 12:38:18 10/08/2023 10:37:53 43475587 43475587 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 10/08/2023 12:37:59 10/08/2023 10:38:34 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 10/08/2023 12:37:56 10/08/2023 10:37:32 43475587 43475587 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 10/08/2023 11:14:15 10/08/2023 11:14:40 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 10/08/2023 11:14:15 10/08/2023 11:14:46 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 10/08/2023 11:14:07 10/08/2023 11:14:18 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 10/08/2023 11:14:07 10/08/2023 11:14:24 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 10/08/2023 11:08:23 10/08/2023 11:08:29 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 10/08/2023 11:08:23 10/08/2023 11:08:35 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 10/08/2023 10:47:28 10/08/2023 10:47:34 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 10/08/2023 10:47:28 10/08/2023 10:47:40 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 10/08/2023 10:47:28 10/08/2023 10:47:45 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 10/08/2023 10:47:28 10/08/2023 10:47:51 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 10/08/2023 10:47:28 10/08/2023 10:47:56 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 10/08/2023 10:47:28 10/08/2023 10:48:02 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 10/08/2023 10:47:28 10/08/2023 10:48:08 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 10/08/2023 10:47:28 10/08/2023 10:48:14 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 10/08/2023 10:36:04 10/08/2023 10:36:15 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 10/08/2023 10:36:04 10/08/2023 10:36:20 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 10/08/2023 10:36:04 10/08/2023 10:36:26 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 10/08/2023 10:36:04 10/08/2023 10:36:31 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 10/08/2023 10:17:45 10/08/2023 10:17:56 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 10/08/2023 10:17:45 10/08/2023 10:18:02 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 10/08/2023 10:17:45 10/08/2023 10:32:19 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 10/08/2023 10:17:45 10/08/2023 10:32:25 43475587 43475587 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 10/08/2023 08:41:58 10/08/2023 08:43:04 43475587 43475587 1,0 1003 Elevator Failure Serial communication broken on board (TTS-2)
KRM_SERVER 10/08/2023 08:41:58 10/08/2023 08:43:21 43475587 43475587 1,0 1003 Elevator Failure Serial communication broken on board (TTS-2)
KRM_SERVER 10/08/2023 08:41:58 10/08/2023 08:43:32 43475587 43475587 1,0 1003 Elevator Failure Serial communication broken on board (TTS-2)
KRM_SERVER 10/08/2023 08:41:58 10/08/2023 08:43:39 43475587 43475587 1,0 1003 Elevator Failure Serial communication broken on board (TTS-2)
KRM_SERVER 10/08/2023 08:41:52 10/08/2023 08:42:19 43475587 43475587 1,0 1000 Elevator Failure Serial communication broken on board (both TTS channels)
KRM_SERVER 10/08/2023 08:41:52 10/08/2023 08:42:25 43475587 43475587 1,0 1003 Elevator Failure Serial communication broken on board (TTS-2)
KRM_SERVER 10/08/2023 08:41:52 10/08/2023 08:42:30 43475587 43475587 1,0 1000 Elevator Failure Serial communication broken on board (both TTS channels)
KRM_SERVER 10/08/2023 08:41:52 10/08/2023 08:42:36 43475587 43475587 1,0 1000 Elevator Failure Serial communication broken on board (both TTS channels)
KRM_SERVER 10/08/2023 08:41:52 10/08/2023 08:42:42 43475587 43475587 1,0 1000 Elevator Failure Serial communication broken on board (both TTS channels)
KRM_SERVER 10/08/2023 08:41:52 10/08/2023 08:43:27 43475587 43475587 1,0 1003 Elevator Failure Serial communication broken on board (TTS-2)
KRM_SERVER 10/08/2023 08:41:51 10/08/2023 08:42:02 43475587 43475587 1,0 1003 Elevator Failure Serial communication broken on board (TTS-2)
KRM_SERVER 10/08/2023 08:41:51 10/08/2023 08:43:10 43475587 43475587 1,0 1003 Elevator Failure Serial communication broken on board (TTS-2)
KRM_SERVER 09/08/2023 22:09:52 09/08/2023 22:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/08/2023 22:10:19 08/08/2023 22:10:19 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/08/2023 14:49:11 08/08/2023 14:49:11 43475587 43475587 1,0 101 Real Alarm Real Alarm
KRM_SERVER 08/08/2023 14:34:12 08/08/2023 14:34:12 43475587 43475587 1,0 101 Real Alarm Real Alarm
KRM_SERVER 08/08/2023 14:23:35 08/08/2023 14:23:35 43475587 43475587 1,0 101 Real Alarm Real Alarm
KRM_SERVER 08/08/2023 14:19:57 08/08/2023 14:20:03 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 08/08/2023 14:19:57 08/08/2023 15:18:06 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 07/08/2023 22:10:09 07/08/2023 22:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/08/2023 13:42:28 07/08/2023 13:42:34 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 07/08/2023 13:42:28 07/08/2023 13:45:14 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/08/2023 22:09:53 06/08/2023 22:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/08/2023 19:05:11 06/08/2023 19:05:17 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 06/08/2023 19:05:11 06/08/2023 19:05:22 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 05/08/2023 22:10:08 05/08/2023 22:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/08/2023 22:10:05 04/08/2023 22:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/08/2023 22:10:14 03/08/2023 22:10:14 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/08/2023 22:10:19 02/08/2023 22:10:19 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/08/2023 22:09:59 01/08/2023 22:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/07/2023 22:10:14 31/07/2023 22:10:14 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/07/2023 22:12:13 30/07/2023 22:12:13 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/07/2023 22:10:24 29/07/2023 22:10:24 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/07/2023 22:10:05 28/07/2023 22:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/07/2023 22:10:09 27/07/2023 22:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/07/2023 22:10:00 26/07/2023 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/07/2023 22:10:38 25/07/2023 22:10:38 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/07/2023 22:10:07 24/07/2023 22:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/07/2023 22:10:41 23/07/2023 22:10:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/07/2023 22:11:59 22/07/2023 22:11:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/07/2023 10:55:55 21/07/2023 10:56:00 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/07/2023 10:55:55 21/07/2023 10:56:13 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/07/2023 22:10:48 20/07/2023 22:10:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/07/2023 22:10:12 19/07/2023 22:10:12 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/07/2023 22:10:17 18/07/2023 22:10:17 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/07/2023 22:12:07 17/07/2023 22:12:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/07/2023 19:02:07 17/07/2023 19:02:13 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/07/2023 19:02:07 17/07/2023 19:03:02 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 16/07/2023 22:10:23 16/07/2023 22:10:23 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/07/2023 22:10:22 15/07/2023 22:10:22 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/07/2023 22:10:10 14/07/2023 22:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/07/2023 22:10:40 13/07/2023 22:10:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/07/2023 18:58:37 13/07/2023 18:58:43 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 13/07/2023 18:58:37 13/07/2023 18:59:39 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 13/07/2023 15:08:53 13/07/2023 15:09:00 43475587 43475587 1,0 1002 Elevator Failure Serial communication broken on board (TTS-1)
KRM_SERVER 13/07/2023 15:08:53 13/07/2023 15:09:29 43475587 43475587 1,0 1002 Elevator Failure Serial communication broken on board (TTS-1)
KRM_SERVER 13/07/2023 15:08:53 13/07/2023 15:09:34 43475587 43475587 1,0 1002 Elevator Failure Serial communication broken on board (TTS-1)
KRM_SERVER 13/07/2023 15:08:53 13/07/2023 15:09:45 43475587 43475587 1,0 1002 Elevator Failure Serial communication broken on board (TTS-1)
KRM_SERVER 13/07/2023 15:07:45 13/07/2023 15:08:43 43475587 43475587 1,0 2000 Elevator Failure Missing COP
KRM_SERVER 13/07/2023 15:07:45 13/07/2023 15:09:12 43475587 43475587 1,0 2000 Elevator Failure Missing COP
KRM_SERVER 13/07/2023 15:07:42 13/07/2023 15:07:48 43475587 43475587 1,0 1161 Elevator Failure KCEDZS board failure - Self check failed
KRM_SERVER 13/07/2023 15:07:42 13/07/2023 15:07:53 43475587 43475587 1,0 2339 Elevator Failure KCEDZS 24 V power supply failure
KRM_SERVER 13/07/2023 15:07:42 13/07/2023 15:07:59 43475587 43475587 1,0 2339 Elevator Failure KCEDZS 24 V power supply failure
KRM_SERVER 13/07/2023 15:07:42 13/07/2023 15:08:04 43475587 43475587 1,0 1161 Elevator Failure KCEDZS board failure - Self check failed
KRM_SERVER 13/07/2023 15:07:42 13/07/2023 15:08:10 43475587 43475587 1,0 1002 Elevator Failure Serial communication broken on board (TTS-1)
KRM_SERVER 13/07/2023 15:07:42 13/07/2023 15:08:16 43475587 43475587 1,0 1000 Elevator Failure Serial communication broken on board (both TTS channels)
KRM_SERVER 13/07/2023 15:07:42 13/07/2023 15:08:21 43475587 43475587 1,0 1003 Elevator Failure Serial communication broken on board (TTS-2)
KRM_SERVER 13/07/2023 15:07:42 13/07/2023 15:08:27 43475587 43475587 1,0 1000 Elevator Failure Serial communication broken on board (both TTS channels)
KRM_SERVER 13/07/2023 15:07:42 13/07/2023 15:08:32 43475587 43475587 1,0 1002 Elevator Failure Serial communication broken on board (TTS-1)
KRM_SERVER 13/07/2023 15:07:42 13/07/2023 15:08:38 43475587 43475587 1,0 1003 Elevator Failure Serial communication broken on board (TTS-2)
KRM_SERVER 13/07/2023 15:07:42 13/07/2023 15:09:23 43475587 43475587 1,0 1000 Elevator Failure Serial communication broken on board (both TTS channels)
KRM_SERVER 13/07/2023 15:07:42 13/07/2023 15:09:40 43475587 43475587 1,0 1000 Elevator Failure Serial communication broken on board (both TTS channels)
KRM_SERVER 13/07/2023 15:07:42 13/07/2023 15:10:30 43475587 43475587 1,0 1161 Elevator Failure KCEDZS board failure - Self check failed
KRM_SERVER 13/07/2023 15:07:42 13/07/2023 15:10:35 43475587 43475587 1,0 2339 Elevator Failure KCEDZS 24 V power supply failure
KRM_SERVER 13/07/2023 15:07:42 13/07/2023 15:10:46 43475587 43475587 1,0 2339 Elevator Failure KCEDZS 24 V power supply failure
KRM_SERVER 13/07/2023 15:07:42 13/07/2023 15:10:52 43475587 43475587 1,0 1161 Elevator Failure KCEDZS board failure - Self check failed
KRM_SERVER 13/07/2023 15:04:56 13/07/2023 15:05:06 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 13/07/2023 15:04:56 13/07/2023 15:05:12 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 13/07/2023 15:04:56 13/07/2023 15:05:57 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 13/07/2023 15:04:56 13/07/2023 15:06:03 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 12/07/2023 22:10:24 12/07/2023 22:10:24 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/07/2023 11:57:52 12/07/2023 09:58:12 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 12/07/2023 11:57:39 12/07/2023 09:57:57 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 12/07/2023 11:57:36 12/07/2023 09:57:44 43475587 43475587 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 12/07/2023 11:52:31 12/07/2023 09:52:39 43475587 43475587 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 12/07/2023 10:12:54 12/07/2023 10:13:20 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 12/07/2023 10:12:54 12/07/2023 10:20:15 43475587 43475587 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 12/07/2023 10:09:12 12/07/2023 10:09:36 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 12/07/2023 10:09:12 12/07/2023 10:09:41 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 12/07/2023 10:09:12 12/07/2023 10:11:29 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 12/07/2023 10:09:12 12/07/2023 10:11:34 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 12/07/2023 10:09:11 12/07/2023 10:09:24 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 12/07/2023 10:09:11 12/07/2023 10:09:30 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 12/07/2023 10:09:11 12/07/2023 10:11:12 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 12/07/2023 10:09:11 12/07/2023 10:11:17 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 12/07/2023 10:05:07 12/07/2023 10:05:51 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 12/07/2023 10:05:07 12/07/2023 10:05:57 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 12/07/2023 10:05:07 12/07/2023 10:06:02 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 12/07/2023 10:05:07 12/07/2023 10:06:08 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 12/07/2023 10:04:59 12/07/2023 10:05:07 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 12/07/2023 10:04:59 12/07/2023 10:05:12 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 12/07/2023 10:04:59 12/07/2023 10:05:24 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 12/07/2023 10:04:59 12/07/2023 10:05:29 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 11/07/2023 22:10:26 11/07/2023 22:10:26 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/07/2023 15:10:01 11/07/2023 15:10:07 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/07/2023 15:10:01 11/07/2023 15:11:10 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/07/2023 22:10:04 10/07/2023 22:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/07/2023 22:10:20 08/07/2023 22:10:20 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/07/2023 22:10:25 07/07/2023 22:10:25 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/07/2023 22:10:35 05/07/2023 22:10:35 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/07/2023 19:33:48 05/07/2023 19:33:54 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 05/07/2023 19:33:48 05/07/2023 19:33:59 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 05/07/2023 19:32:34 05/07/2023 19:32:34 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/07/2023 23:28:34 04/07/2023 21:28:41 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 04/07/2023 21:48:32 04/07/2023 21:49:24 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 04/07/2023 21:48:32 04/07/2023 21:49:32 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 04/07/2023 21:48:24 04/07/2023 21:48:58 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 04/07/2023 21:48:24 04/07/2023 21:49:09 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 04/07/2023 21:48:23 04/07/2023 21:48:49 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 04/07/2023 21:48:23 04/07/2023 21:49:14 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 04/07/2023 21:48:15 04/07/2023 21:48:23 43475587 43475587 1,0 1109 Elevator Failure Landing door not opened after top of car inspection
KRM_SERVER 04/07/2023 21:48:15 04/07/2023 21:48:45 43475587 43475587 1,0 1109 Elevator Failure Landing door not opened after top of car inspection
KRM_SERVER 04/07/2023 21:43:44 04/07/2023 21:45:33 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 04/07/2023 21:43:43 04/07/2023 21:45:36 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 04/07/2023 21:43:42 04/07/2023 21:45:46 43475587 43475587 1,0 1023 Elevator Failure Car door bypass switch active
KRM_SERVER 04/07/2023 21:43:42 04/07/2023 21:45:48 43475587 43475587 1,0 1023 Elevator Failure Car door bypass switch active
KRM_SERVER 04/07/2023 21:43:35 04/07/2023 21:45:55 43475587 43475587 1,0 1082 Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs
KRM_SERVER 04/07/2023 21:43:35 04/07/2023 21:46:00 43475587 43475587 1,0 1082 Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs
KRM_SERVER 04/07/2023 21:43:35 04/07/2023 21:50:02 43475587 43475587 1,0 1082 Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs
KRM_SERVER 04/07/2023 21:43:35 04/07/2023 21:50:07 43475587 43475587 1,0 1082 Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs
KRM_SERVER 04/07/2023 21:43:18 04/07/2023 21:44:05 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:43:18 04/07/2023 21:44:47 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:43:18 04/07/2023 21:44:58 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:43:00 04/07/2023 21:43:09 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:43:00 04/07/2023 21:43:34 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:43:00 04/07/2023 21:43:41 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:43:00 04/07/2023 21:43:49 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:42:59 04/07/2023 21:43:31 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:42:42 04/07/2023 21:46:28 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:42:41 04/07/2023 21:46:43 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:42:17 04/07/2023 21:46:52 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 21:42:17 04/07/2023 21:47:00 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 21:42:17 04/07/2023 21:47:38 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 21:42:17 04/07/2023 21:47:41 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 21:41:53 04/07/2023 21:42:59 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:41:44 04/07/2023 21:41:57 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:41:44 04/07/2023 21:42:05 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:41:44 04/07/2023 21:42:09 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:41:44 04/07/2023 21:42:18 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:41:44 04/07/2023 21:42:42 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:41:44 04/07/2023 21:42:46 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:40:02 04/07/2023 21:40:51 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:40:02 04/07/2023 21:41:46 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:40:01 04/07/2023 21:40:31 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:40:01 04/07/2023 21:40:33 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:40:01 04/07/2023 21:40:40 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:40:01 04/07/2023 21:41:19 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:40:01 04/07/2023 21:41:28 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:40:01 04/07/2023 21:41:38 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:39:52 04/07/2023 21:39:58 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 21:39:52 04/07/2023 21:40:07 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 21:39:52 04/07/2023 21:40:13 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 21:39:52 04/07/2023 21:40:18 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 21:39:52 04/07/2023 21:40:45 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 21:39:52 04/07/2023 21:40:59 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 21:39:52 04/07/2023 21:50:39 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 21:39:52 04/07/2023 21:50:43 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 21:38:29 04/07/2023 21:38:43 43475587 43475587 1,0 1109 Elevator Failure Landing door not opened after top of car inspection
KRM_SERVER 04/07/2023 21:38:29 04/07/2023 21:39:13 43475587 43475587 1,0 1109 Elevator Failure Landing door not opened after top of car inspection
KRM_SERVER 04/07/2023 21:36:43 04/07/2023 21:36:51 43475587 43475587 1,0 1109 Elevator Failure Landing door not opened after top of car inspection
KRM_SERVER 04/07/2023 21:36:43 04/07/2023 21:39:08 43475587 43475587 1,0 1109 Elevator Failure Landing door not opened after top of car inspection
KRM_SERVER 04/07/2023 21:30:39 04/07/2023 21:31:00 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:30:39 04/07/2023 21:31:10 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:30:39 04/07/2023 21:38:14 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:30:39 04/07/2023 21:38:30 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:30:38 04/07/2023 21:30:46 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:30:38 04/07/2023 21:30:52 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:30:38 04/07/2023 21:38:06 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:30:38 04/07/2023 21:38:23 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:29:28 04/07/2023 21:29:43 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 21:29:28 04/07/2023 21:29:47 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 21:29:28 04/07/2023 21:29:54 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 21:29:28 04/07/2023 21:29:58 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 21:29:28 04/07/2023 21:31:03 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 21:29:28 04/07/2023 21:31:14 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 21:29:28 04/07/2023 21:31:23 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 21:29:28 04/07/2023 21:31:25 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 21:25:36 04/07/2023 21:25:53 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:24:36 04/07/2023 21:24:44 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:24:36 04/07/2023 21:24:47 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:24:36 04/07/2023 21:24:54 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:24:36 04/07/2023 21:24:58 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 04/07/2023 21:24:36 04/07/2023 21:25:43 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:24:36 04/07/2023 21:25:50 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 04/07/2023 21:18:45 04/07/2023 21:20:06 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 04/07/2023 21:18:45 04/07/2023 21:20:12 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 04/07/2023 21:18:45 04/07/2023 21:20:23 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 04/07/2023 21:18:45 04/07/2023 21:20:29 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 04/07/2023 21:18:37 04/07/2023 21:18:54 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 04/07/2023 21:18:37 04/07/2023 21:19:00 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 04/07/2023 21:18:37 04/07/2023 21:19:11 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 04/07/2023 21:18:37 04/07/2023 21:19:16 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 04/07/2023 17:10:12 04/07/2023 15:10:11 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 04/07/2023 17:09:56 04/07/2023 15:10:26 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 04/07/2023 15:32:12 04/07/2023 15:32:25 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:32:12 04/07/2023 15:32:31 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 15:32:12 04/07/2023 15:32:36 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:32:12 04/07/2023 15:32:42 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 15:32:12 04/07/2023 21:19:22 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 15:32:12 04/07/2023 21:19:27 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:32:12 04/07/2023 21:19:50 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 15:32:12 04/07/2023 21:19:55 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:07:06 04/07/2023 15:07:27 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 04/07/2023 15:07:06 04/07/2023 15:07:49 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 04/07/2023 15:07:05 04/07/2023 15:07:22 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 04/07/2023 15:07:05 04/07/2023 15:07:44 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 04/07/2023 15:06:44 04/07/2023 15:06:59 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 04/07/2023 15:06:04 04/07/2023 15:06:48 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 04/07/2023 15:06:04 04/07/2023 15:06:54 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 04/07/2023 15:05:56 04/07/2023 15:06:31 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:05:56 04/07/2023 15:06:37 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:05:48 04/07/2023 15:06:09 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:05:48 04/07/2023 15:06:14 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:05:48 04/07/2023 15:06:20 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:05:48 04/07/2023 15:06:26 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:05:25 04/07/2023 15:05:41 43475587 43475587 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/07/2023 15:05:25 04/07/2023 15:06:43 43475587 43475587 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/07/2023 15:03:29 04/07/2023 15:04:07 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 15:03:29 04/07/2023 15:04:12 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:03:29 04/07/2023 15:05:47 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:03:29 04/07/2023 15:06:03 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 15:03:28 04/07/2023 15:03:50 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 15:03:28 04/07/2023 15:03:55 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:03:28 04/07/2023 15:04:51 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:03:28 04/07/2023 15:05:58 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 15:01:01 04/07/2023 15:01:30 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 15:01:01 04/07/2023 15:01:35 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:01:01 04/07/2023 15:02:42 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:01:00 04/07/2023 15:01:13 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 04/07/2023 15:01:00 04/07/2023 15:01:19 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:01:00 04/07/2023 15:02:37 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/07/2023 15:01:00 04/07/2023 15:02:48 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 02/07/2023 22:10:36 02/07/2023 22:10:36 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/07/2023 22:10:40 01/07/2023 23:47:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/07/2023 16:45:58 01/07/2023 16:46:05 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 01/07/2023 16:45:58 01/07/2023 16:47:22 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 01/07/2023 16:42:47 01/07/2023 16:42:53 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 01/07/2023 16:42:47 01/07/2023 16:43:38 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/06/2023 22:10:29 30/06/2023 22:10:29 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/06/2023 10:54:11 30/06/2023 10:54:11 43475587 43475587 1,0 102 Test Alarm Test Alarm
KRM_SERVER 29/06/2023 22:10:23 29/06/2023 22:10:23 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/06/2023 22:10:07 29/06/2023 02:58:23 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/06/2023 22:10:19 27/06/2023 22:10:19 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/06/2023 22:10:27 26/06/2023 22:10:27 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/06/2023 08:43:38 26/06/2023 08:43:44 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 26/06/2023 08:43:38 26/06/2023 08:44:52 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 26/06/2023 07:50:21 26/06/2023 07:50:26 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 26/06/2023 07:50:21 26/06/2023 07:52:11 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/06/2023 22:10:16 25/06/2023 22:10:16 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/06/2023 22:10:20 23/06/2023 22:10:20 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/06/2023 22:10:46 22/06/2023 22:10:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/06/2023 22:10:16 22/06/2023 05:44:15 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/06/2023 17:10:58 21/06/2023 15:11:00 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/06/2023 17:10:47 21/06/2023 15:11:13 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/06/2023 15:14:50 21/06/2023 15:14:55 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 21/06/2023 15:14:02 21/06/2023 15:14:08 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 21/06/2023 15:14:02 21/06/2023 15:14:13 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 21/06/2023 15:13:35 21/06/2023 15:13:46 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 21/06/2023 15:13:35 21/06/2023 15:13:51 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 21/06/2023 15:12:33 21/06/2023 15:12:41 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 21/06/2023 15:12:07 21/06/2023 15:12:30 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 21/06/2023 15:12:07 21/06/2023 15:12:36 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 21/06/2023 15:11:48 21/06/2023 15:12:08 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 21/06/2023 15:11:48 21/06/2023 15:12:13 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 21/06/2023 15:11:46 21/06/2023 15:11:51 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 21/06/2023 15:11:46 21/06/2023 15:12:02 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 21/06/2023 15:11:46 21/06/2023 15:12:19 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 21/06/2023 15:11:46 21/06/2023 15:12:25 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 19/06/2023 22:12:03 19/06/2023 22:12:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/06/2023 22:10:03 18/06/2023 22:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/06/2023 22:10:17 17/06/2023 22:10:17 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/06/2023 09:13:25 17/06/2023 09:13:31 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/06/2023 09:13:25 17/06/2023 09:14:07 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/06/2023 09:09:14 17/06/2023 09:09:20 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/06/2023 09:09:14 17/06/2023 09:10:41 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 16/06/2023 22:12:16 16/06/2023 22:12:16 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/06/2023 22:10:30 15/06/2023 22:10:30 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/06/2023 13:26:26 15/06/2023 13:26:32 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 15/06/2023 13:26:26 15/06/2023 13:26:47 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 14/06/2023 22:11:09 14/06/2023 22:11:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/06/2023 22:13:01 13/06/2023 22:13:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/06/2023 22:11:12 12/06/2023 22:11:12 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/06/2023 22:11:12 11/06/2023 22:11:12 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/06/2023 21:29:35 11/06/2023 21:29:41 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/06/2023 21:29:35 11/06/2023 21:31:04 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/06/2023 22:11:16 10/06/2023 22:11:16 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/06/2023 13:27:51 10/06/2023 13:27:59 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/06/2023 13:27:51 10/06/2023 13:29:14 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/06/2023 22:11:20 09/06/2023 22:11:20 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/06/2023 22:11:11 08/06/2023 22:11:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/06/2023 22:11:23 07/06/2023 22:11:23 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/06/2023 13:01:38 07/06/2023 11:01:01 43475587 43475587 1,0 4017 Elevator Failure KCEAPM 12V power failed (battery failure)
KRM_SERVER 07/06/2023 12:49:03 07/06/2023 10:48:25 43475587 43475587 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 06/06/2023 22:09:59 06/06/2023 22:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/06/2023 18:54:02 06/06/2023 18:54:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/06/2023 08:52:37 06/06/2023 08:52:37 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/06/2023 22:09:57 05/06/2023 22:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/06/2023 22:10:13 04/06/2023 22:10:13 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/06/2023 22:10:13 03/06/2023 22:10:13 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/06/2023 22:10:14 02/06/2023 22:10:14 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/06/2023 22:10:28 01/06/2023 22:10:28 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/05/2023 22:10:23 31/05/2023 22:10:23 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/05/2023 22:10:30 30/05/2023 22:10:30 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/05/2023 22:10:20 29/05/2023 22:10:20 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/05/2023 22:10:01 28/05/2023 22:10:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/05/2023 22:10:36 27/05/2023 22:10:36 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/05/2023 16:40:28 27/05/2023 16:40:39 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/05/2023 16:40:28 27/05/2023 16:40:59 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 26/05/2023 22:10:28 26/05/2023 22:10:28 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/05/2023 22:10:11 25/05/2023 22:10:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/05/2023 22:09:58 24/05/2023 22:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/05/2023 22:09:56 23/05/2023 22:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/05/2023 22:11:43 21/05/2023 22:11:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/05/2023 23:52:48 20/05/2023 23:52:54 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/05/2023 23:52:48 20/05/2023 23:53:13 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/05/2023 23:49:46 20/05/2023 23:49:50 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/05/2023 23:49:46 20/05/2023 23:50:32 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/05/2023 22:10:11 20/05/2023 22:10:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/05/2023 22:10:12 19/05/2023 22:10:12 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/05/2023 22:10:18 18/05/2023 22:10:18 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/05/2023 22:10:19 17/05/2023 22:10:19 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/05/2023 20:18:17 17/05/2023 20:18:22 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/05/2023 20:18:17 17/05/2023 20:19:53 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 16/05/2023 22:09:59 16/05/2023 22:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/05/2023 22:11:38 16/05/2023 11:50:43 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/05/2023 22:10:10 15/05/2023 22:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/05/2023 22:10:39 14/05/2023 22:10:39 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/05/2023 22:10:34 13/05/2023 22:10:34 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/05/2023 22:13:44 12/05/2023 22:13:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/05/2023 22:10:08 12/05/2023 22:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/05/2023 22:11:55 11/05/2023 22:11:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/05/2023 22:11:40 10/05/2023 22:11:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/05/2023 22:10:11 10/05/2023 22:10:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/05/2023 09:25:30 10/05/2023 09:25:35 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/05/2023 09:25:30 10/05/2023 09:25:48 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/05/2023 22:15:03 09/05/2023 22:15:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/05/2023 17:32:53 09/05/2023 15:33:01 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 09/05/2023 17:32:34 09/05/2023 15:32:43 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 09/05/2023 17:32:29 09/05/2023 15:32:37 43475587 43475587 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 09/05/2023 17:30:50 09/05/2023 15:30:58 43475587 43475587 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 09/05/2023 17:27:49 09/05/2023 15:27:58 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 09/05/2023 17:27:40 09/05/2023 15:27:53 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 09/05/2023 15:40:38 09/05/2023 15:40:49 43475587 43475587 1,0 1109 Elevator Failure Landing door not opened after top of car inspection
KRM_SERVER 09/05/2023 15:40:38 09/05/2023 15:41:12 43475587 43475587 1,0 1109 Elevator Failure Landing door not opened after top of car inspection
KRM_SERVER 09/05/2023 15:37:29 09/05/2023 15:37:36 43475587 43475587 1,0 1109 Elevator Failure Landing door not opened after top of car inspection
KRM_SERVER 09/05/2023 15:37:29 09/05/2023 15:41:07 43475587 43475587 1,0 1109 Elevator Failure Landing door not opened after top of car inspection
KRM_SERVER 09/05/2023 15:37:02 09/05/2023 15:37:19 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 09/05/2023 15:37:02 09/05/2023 15:37:31 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 09/05/2023 15:37:01 09/05/2023 15:37:14 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 09/05/2023 15:37:01 09/05/2023 15:37:25 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 09/05/2023 15:35:24 09/05/2023 15:35:40 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 09/05/2023 15:35:24 09/05/2023 15:35:51 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 09/05/2023 15:35:23 09/05/2023 15:35:29 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 09/05/2023 15:35:23 09/05/2023 15:35:46 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 09/05/2023 15:32:51 09/05/2023 15:33:01 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 09/05/2023 15:32:51 09/05/2023 15:33:07 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 09/05/2023 15:32:51 09/05/2023 15:33:12 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 09/05/2023 15:32:51 09/05/2023 15:33:18 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 09/05/2023 15:32:51 09/05/2023 15:40:13 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 09/05/2023 15:32:51 09/05/2023 15:40:19 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 09/05/2023 15:32:51 09/05/2023 15:40:30 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 09/05/2023 15:32:51 09/05/2023 15:40:35 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 08/05/2023 22:10:22 08/05/2023 22:10:22 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/05/2023 22:10:04 07/05/2023 22:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/05/2023 22:10:46 06/05/2023 22:10:46 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/05/2023 22:10:07 05/05/2023 22:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/05/2023 22:10:09 04/05/2023 22:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/05/2023 17:31:19 04/05/2023 15:31:05 43475587 43475587 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 04/05/2023 08:49:49 04/05/2023 08:50:12 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/05/2023 08:49:49 04/05/2023 08:50:18 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/05/2023 08:49:49 04/05/2023 08:53:57 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 04/05/2023 08:49:49 04/05/2023 08:54:02 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 03/05/2023 22:12:02 03/05/2023 22:12:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/05/2023 19:56:56 03/05/2023 19:57:13 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 03/05/2023 19:56:56 03/05/2023 19:57:19 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 03/05/2023 19:56:56 03/05/2023 19:57:24 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 03/05/2023 19:56:56 03/05/2023 19:57:30 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 03/05/2023 19:56:56 03/05/2023 19:57:37 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 03/05/2023 19:56:56 03/05/2023 19:57:48 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 03/05/2023 19:56:55 03/05/2023 19:57:02 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 03/05/2023 19:56:55 03/05/2023 19:57:43 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 03/05/2023 13:31:48 03/05/2023 13:32:12 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 03/05/2023 13:31:48 03/05/2023 13:32:18 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 03/05/2023 13:31:48 03/05/2023 13:41:27 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 03/05/2023 13:31:48 03/05/2023 13:41:33 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 03/05/2023 13:31:47 03/05/2023 13:32:01 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 03/05/2023 13:31:47 03/05/2023 13:32:07 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 03/05/2023 13:31:47 03/05/2023 13:41:16 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 03/05/2023 13:31:47 03/05/2023 13:41:22 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 02/05/2023 22:10:13 02/05/2023 22:10:13 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/05/2023 22:10:00 01/05/2023 22:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/05/2023 14:14:15 01/05/2023 14:14:21 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 01/05/2023 14:14:15 01/05/2023 14:15:45 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/04/2023 22:10:15 30/04/2023 22:10:15 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/04/2023 22:10:30 29/04/2023 22:10:30 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/04/2023 22:12:04 28/04/2023 22:12:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/04/2023 22:10:07 27/04/2023 22:10:07 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/04/2023 22:10:56 26/04/2023 22:10:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/04/2023 22:10:14 25/04/2023 22:10:14 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/04/2023 19:45:10 25/04/2023 19:45:16 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/04/2023 19:45:10 25/04/2023 19:45:43 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/04/2023 12:09:21 25/04/2023 12:09:26 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/04/2023 12:09:21 25/04/2023 12:10:41 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/04/2023 12:05:35 25/04/2023 12:05:39 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/04/2023 12:05:35 25/04/2023 12:06:50 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/04/2023 22:10:29 24/04/2023 22:10:29 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/04/2023 22:10:16 23/04/2023 22:10:16 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/04/2023 22:44:54 22/04/2023 22:45:00 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 22/04/2023 22:44:54 22/04/2023 22:45:12 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 22/04/2023 22:10:19 22/04/2023 22:10:19 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/04/2023 22:10:51 21/04/2023 22:10:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/04/2023 22:10:49 20/04/2023 22:10:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/04/2023 22:10:20 19/04/2023 22:10:20 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/04/2023 22:10:26 18/04/2023 22:10:26 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/04/2023 22:10:28 17/04/2023 22:10:28 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/04/2023 22:11:09 16/04/2023 22:11:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/04/2023 22:11:19 15/04/2023 22:11:19 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/04/2023 22:12:54 14/04/2023 22:12:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/04/2023 22:02:59 14/04/2023 20:03:25 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 14/04/2023 22:02:54 14/04/2023 20:03:12 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 14/04/2023 21:58:41 14/04/2023 19:58:36 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 14/04/2023 21:58:29 14/04/2023 19:58:50 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 14/04/2023 19:43:27 14/04/2023 19:43:32 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 14/04/2023 19:43:27 14/04/2023 19:43:38 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 14/04/2023 19:43:27 14/04/2023 19:43:43 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 14/04/2023 19:43:27 14/04/2023 19:43:49 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 14/04/2023 19:43:27 14/04/2023 19:44:23 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 14/04/2023 19:43:27 14/04/2023 19:44:29 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 14/04/2023 19:43:27 14/04/2023 19:44:40 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 14/04/2023 19:43:27 14/04/2023 19:44:46 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 14/04/2023 12:52:35 14/04/2023 12:52:51 43475587 43475587 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/04/2023 12:52:35 14/04/2023 12:53:13 43475587 43475587 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/04/2023 12:51:44 14/04/2023 12:52:40 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 14/04/2023 12:51:44 14/04/2023 12:53:19 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 14/04/2023 12:51:44 14/04/2023 12:53:30 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 14/04/2023 12:51:44 14/04/2023 12:53:36 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 13/04/2023 22:10:18 13/04/2023 22:10:18 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/04/2023 15:52:56 13/04/2023 15:53:02 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 13/04/2023 15:52:56 13/04/2023 15:53:27 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/04/2023 22:18:05 12/04/2023 22:18:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/04/2023 22:16:36 11/04/2023 22:16:36 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/04/2023 22:16:38 10/04/2023 22:16:38 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/04/2023 22:16:39 09/04/2023 22:16:39 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/04/2023 15:44:11 09/04/2023 15:44:16 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/04/2023 15:44:11 09/04/2023 15:44:22 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 08/04/2023 22:16:37 08/04/2023 22:16:38 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/04/2023 22:16:35 07/04/2023 22:16:35 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/04/2023 22:16:36 06/04/2023 22:16:36 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/04/2023 22:16:44 05/04/2023 22:16:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/04/2023 22:16:40 04/04/2023 22:16:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/04/2023 22:16:40 03/04/2023 22:16:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/04/2023 21:37:27 03/04/2023 21:37:36 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 03/04/2023 21:37:27 03/04/2023 21:37:56 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 03/04/2023 19:37:27 03/04/2023 19:37:36 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 03/04/2023 19:37:27 03/04/2023 19:37:56 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/04/2023 22:16:50 02/04/2023 22:16:50 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/04/2023 18:10:38 02/04/2023 18:10:43 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 02/04/2023 18:10:38 02/04/2023 18:10:49 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 01/04/2023 22:16:42 01/04/2023 22:16:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/03/2023 22:16:45 31/03/2023 22:16:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/03/2023 22:16:52 30/03/2023 22:16:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/03/2023 22:16:35 29/03/2023 22:16:35 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/03/2023 17:16:16 29/03/2023 15:10:20 43475587 43475587 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 29/03/2023 15:18:17 29/03/2023 15:19:10 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 29/03/2023 15:18:17 29/03/2023 15:19:17 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 29/03/2023 15:18:17 29/03/2023 15:19:23 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 29/03/2023 15:18:17 29/03/2023 15:19:29 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 29/03/2023 15:18:10 29/03/2023 15:18:33 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 29/03/2023 15:18:10 29/03/2023 15:18:40 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 29/03/2023 15:18:10 29/03/2023 15:18:46 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 29/03/2023 15:18:10 29/03/2023 15:18:52 43475587 43475587 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 29/03/2023 15:13:26 29/03/2023 15:13:44 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 29/03/2023 15:13:26 29/03/2023 15:13:49 43475587 43475587 1,0 1024 Elevator Failure Hoistway door bypass switch active
KRM_SERVER 29/03/2023 15:12:07 29/03/2023 15:14:02 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 29/03/2023 15:12:07 29/03/2023 15:14:15 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 29/03/2023 15:12:04 29/03/2023 15:13:49 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:12:04 29/03/2023 15:13:50 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:12:03 29/03/2023 15:13:48 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:12:03 29/03/2023 15:14:28 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:11:59 29/03/2023 15:13:42 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 29/03/2023 15:11:59 29/03/2023 15:13:43 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 29/03/2023 15:11:59 29/03/2023 15:13:44 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 29/03/2023 15:11:59 29/03/2023 15:13:45 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 29/03/2023 15:11:51 29/03/2023 15:13:41 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:11:51 29/03/2023 15:13:42 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:11:51 29/03/2023 15:13:45 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:11:51 29/03/2023 15:13:47 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:09:37 29/03/2023 15:09:48 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:09:37 29/03/2023 15:09:54 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:09:37 29/03/2023 15:09:59 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:09:37 29/03/2023 15:10:05 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:09:37 29/03/2023 15:15:00 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:09:37 29/03/2023 15:15:06 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:08:12 29/03/2023 15:08:47 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:08:12 29/03/2023 15:09:09 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:08:11 29/03/2023 15:08:42 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:08:11 29/03/2023 15:09:04 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 29/03/2023 15:08:03 29/03/2023 15:08:14 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 29/03/2023 15:08:03 29/03/2023 15:08:20 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 29/03/2023 15:08:03 29/03/2023 15:08:25 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 29/03/2023 15:08:03 29/03/2023 15:08:36 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 29/03/2023 15:08:03 29/03/2023 15:09:15 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 29/03/2023 15:08:03 29/03/2023 15:09:20 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 29/03/2023 15:08:02 29/03/2023 15:08:09 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 29/03/2023 15:08:02 29/03/2023 15:08:31 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 28/03/2023 22:09:59 28/03/2023 22:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/03/2023 22:10:14 27/03/2023 22:10:14 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/03/2023 21:10:01 30/03/2023 07:46:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/03/2023 21:10:03 25/03/2023 21:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/03/2023 21:10:18 24/03/2023 21:10:18 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/03/2023 21:15:56 23/03/2023 21:15:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/03/2023 21:10:10 22/03/2023 21:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/03/2023 21:10:11 21/03/2023 21:10:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/03/2023 21:09:58 20/03/2023 21:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/03/2023 21:10:10 19/03/2023 21:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/03/2023 21:09:42 18/03/2023 21:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/03/2023 21:09:52 17/03/2023 21:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/03/2023 21:09:54 16/03/2023 21:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/03/2023 14:17:16 16/03/2023 14:17:16 43475587 43475587 1,0 102 Test alarm Test Alarm (TAT)
KRM_SERVER 15/03/2023 21:09:55 15/03/2023 21:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/03/2023 21:09:52 14/03/2023 21:09:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/03/2023 21:09:49 13/03/2023 21:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/03/2023 21:10:00 12/03/2023 21:10:01 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/03/2023 16:18:51 12/03/2023 16:18:57 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/03/2023 16:18:51 12/03/2023 16:21:31 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/03/2023 21:10:14 11/03/2023 21:10:14 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/03/2023 21:09:55 10/03/2023 21:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/03/2023 21:09:56 09/03/2023 21:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/03/2023 19:40:35 09/03/2023 19:40:40 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/03/2023 19:40:35 09/03/2023 19:53:32 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/03/2023 19:23:14 09/03/2023 19:23:19 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/03/2023 19:23:14 09/03/2023 19:27:31 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/03/2023 13:51:49 09/03/2023 13:51:54 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/03/2023 13:51:49 09/03/2023 13:53:31 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 08/03/2023 21:09:58 08/03/2023 21:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/03/2023 21:10:09 07/03/2023 21:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/03/2023 21:10:20 06/03/2023 21:10:20 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/03/2023 21:10:09 05/03/2023 21:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/03/2023 21:10:11 04/03/2023 21:10:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/03/2023 13:57:20 04/03/2023 13:57:26 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 04/03/2023 13:57:20 04/03/2023 13:57:53 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 03/03/2023 21:10:11 03/03/2023 21:10:11 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/03/2023 21:10:25 02/03/2023 21:10:25 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/03/2023 21:09:40 01/03/2023 21:09:40 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/02/2023 23:19:22 28/02/2023 23:20:18 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 28/02/2023 23:19:21 28/02/2023 23:20:23 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 28/02/2023 23:18:42 28/02/2023 23:20:47 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 28/02/2023 23:18:42 28/02/2023 23:20:52 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 28/02/2023 23:18:41 28/02/2023 23:21:21 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 28/02/2023 23:18:41 28/02/2023 23:21:32 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 28/02/2023 23:18:20 28/02/2023 23:19:49 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 28/02/2023 23:18:20 28/02/2023 23:19:55 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 28/02/2023 23:18:20 28/02/2023 23:21:48 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 28/02/2023 23:18:20 28/02/2023 23:21:54 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 28/02/2023 23:18:20 28/02/2023 23:21:59 43475587 43475587 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 28/02/2023 23:18:20 28/02/2023 23:22:05 43475587 43475587 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 28/02/2023 23:18:11 28/02/2023 23:19:22 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/02/2023 23:18:11 28/02/2023 23:19:27 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/02/2023 23:18:11 28/02/2023 23:19:33 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/02/2023 23:18:11 28/02/2023 23:19:38 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/02/2023 23:18:03 28/02/2023 23:18:32 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 28/02/2023 23:18:03 28/02/2023 23:18:37 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 28/02/2023 23:18:03 28/02/2023 23:18:49 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 28/02/2023 23:18:03 28/02/2023 23:18:54 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 28/02/2023 23:11:04 28/02/2023 23:11:09 43475587 43475587 1,0 1109 Elevator Failure Landing door not opened after top of car inspection
KRM_SERVER 28/02/2023 23:11:04 28/02/2023 23:15:55 43475587 43475587 1,0 1109 Elevator Failure Landing door not opened after top of car inspection
KRM_SERVER 28/02/2023 23:04:15 28/02/2023 23:05:21 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 28/02/2023 23:04:15 28/02/2023 23:05:26 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 28/02/2023 23:04:15 28/02/2023 23:05:32 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 28/02/2023 23:04:15 28/02/2023 23:15:44 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 28/02/2023 23:04:15 28/02/2023 23:16:01 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 28/02/2023 23:04:15 28/02/2023 23:16:06 43475587 43475587 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 28/02/2023 23:04:14 28/02/2023 23:05:37 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 28/02/2023 23:04:14 28/02/2023 23:15:39 43475587 43475587 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 28/02/2023 23:03:20 28/02/2023 23:04:53 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/02/2023 23:03:20 28/02/2023 23:05:04 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/02/2023 23:03:19 28/02/2023 23:04:47 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/02/2023 23:03:19 28/02/2023 23:04:58 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/02/2023 23:03:11 28/02/2023 23:03:46 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 28/02/2023 23:03:11 28/02/2023 23:03:51 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 28/02/2023 23:03:11 28/02/2023 23:04:02 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 28/02/2023 23:03:11 28/02/2023 23:04:08 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 28/02/2023 23:03:07 28/02/2023 23:03:12 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/02/2023 23:03:07 28/02/2023 23:03:18 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/02/2023 23:03:07 28/02/2023 23:03:23 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/02/2023 23:03:07 28/02/2023 23:03:29 43475587 43475587 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/02/2023 23:01:04 28/02/2023 23:01:10 43475587 43475587 1,0 1082 Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs
KRM_SERVER 28/02/2023 23:01:04 28/02/2023 23:01:16 43475587 43475587 1,0 1082 Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs
KRM_SERVER 28/02/2023 23:01:04 28/02/2023 23:04:14 43475587 43475587 1,0 1082 Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs
KRM_SERVER 28/02/2023 23:01:04 28/02/2023 23:04:36 43475587 43475587 1,0 1082 Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs
KRM_SERVER 28/02/2023 22:59:33 28/02/2023 23:00:47 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/02/2023 22:59:33 28/02/2023 23:00:59 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/02/2023 22:59:33 28/02/2023 23:01:04 43475587 43475587 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/02/2023 22:59:25 28/02/2023 22:59:51 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 28/02/2023 22:59:25 28/02/2023 22:59:57 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 28/02/2023 22:59:25 28/02/2023 23:00:08 43475587 43475587 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 28/02/2023 22:59:25 28/02/2023 23:00:14 43475587 43475587 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 28/02/2023 21:11:51 28/02/2023 21:11:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/02/2023 08:03:10 28/02/2023 08:03:20 43475587 43475587 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 28/02/2023 08:03:10 28/02/2023 22:59:34 43475587 43475587 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 27/02/2023 21:09:35 27/02/2023 21:09:35 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/02/2023 21:09:49 26/02/2023 21:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/02/2023 21:09:55 24/02/2023 21:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/02/2023 11:06:35 24/02/2023 11:06:35 43475587 43475587 1,0 102 Test alarm Test Alarm (TAT)
KRM_SERVER 23/02/2023 21:11:52 23/02/2023 21:11:52 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/02/2023 21:09:45 22/02/2023 21:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/02/2023 21:09:59 21/02/2023 21:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/02/2023 21:09:49 20/02/2023 21:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/02/2023 21:10:09 19/02/2023 21:10:09 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/02/2023 21:09:58 18/02/2023 21:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/02/2023 21:09:51 17/02/2023 21:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/02/2023 21:09:54 16/02/2023 21:09:54 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/02/2023 21:10:04 15/02/2023 21:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/02/2023 21:10:06 14/02/2023 21:10:06 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/02/2023 21:09:58 13/02/2023 21:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/02/2023 21:10:07 12/02/2023 21:10:10 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/02/2023 21:10:02 11/02/2023 21:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/02/2023 08:02:58 11/02/2023 08:03:04 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/02/2023 08:02:58 11/02/2023 08:06:55 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/02/2023 21:10:13 10/02/2023 21:10:13 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/02/2023 21:10:16 09/02/2023 21:10:16 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/02/2023 21:09:45 08/02/2023 21:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/02/2023 21:09:45 07/02/2023 21:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/02/2023 19:31:07 07/02/2023 19:31:13 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 07/02/2023 19:31:07 07/02/2023 19:31:53 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/02/2023 21:09:47 06/02/2023 21:09:47 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/02/2023 21:09:48 05/02/2023 21:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/02/2023 21:09:41 04/02/2023 21:09:41 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/02/2023 21:09:42 03/02/2023 21:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 02/02/2023 21:09:44 02/02/2023 21:09:44 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/02/2023 21:09:55 01/02/2023 21:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 31/01/2023 21:09:47 31/01/2023 21:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 30/01/2023 21:09:58 30/01/2023 21:09:58 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 29/01/2023 21:09:51 29/01/2023 21:09:51 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 28/01/2023 21:09:53 28/01/2023 21:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 27/01/2023 21:10:03 27/01/2023 21:10:03 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 26/01/2023 21:10:05 26/01/2023 21:10:05 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 25/01/2023 21:09:57 25/01/2023 21:09:57 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 24/01/2023 21:10:08 24/01/2023 21:10:08 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 23/01/2023 21:10:01 23/01/2023 21:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 22/01/2023 21:10:12 22/01/2023 21:10:12 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 21/01/2023 21:10:13 21/01/2023 21:10:13 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 20/01/2023 21:10:15 20/01/2023 21:10:15 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 19/01/2023 21:10:17 19/01/2023 21:10:17 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 18/01/2023 21:09:32 18/01/2023 21:09:32 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 17/01/2023 21:09:33 17/01/2023 21:09:33 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 16/01/2023 21:09:35 16/01/2023 21:09:35 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 15/01/2023 21:09:45 15/01/2023 21:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 14/01/2023 21:09:48 14/01/2023 21:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 13/01/2023 21:09:48 13/01/2023 21:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 12/01/2023 21:09:42 12/01/2023 21:09:42 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 11/01/2023 21:09:53 11/01/2023 21:09:53 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 10/01/2023 21:09:45 10/01/2023 21:09:45 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 09/01/2023 21:09:55 09/01/2023 21:09:55 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 08/01/2023 21:09:48 08/01/2023 21:09:48 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 07/01/2023 21:09:49 07/01/2023 21:09:49 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 06/01/2023 21:10:00 06/01/2023 21:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 05/01/2023 21:10:02 05/01/2023 21:10:02 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 04/01/2023 21:10:03 04/01/2023 21:10:04 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/01/2023 21:09:56 03/01/2023 21:09:56 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 03/01/2023 15:52:05 03/01/2023 15:52:05 43475587 43475587 1,0 102 Temporary Fault Test Alarm
KRM_SERVER 02/01/2023 21:09:59 02/01/2023 21:09:59 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/01/2023 21:10:00 01/01/2023 21:10:00 43475587 43475587 1,0 Réception Appel Cyclique
KRM_SERVER 01/01/2023 17:14:01 01/01/2023 17:14:07 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 01/01/2023 17:14:01 01/01/2023 17:16:40 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 01/01/2023 13:48:04 01/01/2023 13:48:09 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 01/01/2023 13:48:04 01/01/2023 13:49:17 43475587 43475587 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 01/01/2000 01:05:55 04/07/2023 21:28:15 43475587 43475587 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 01/01/2000 01:05:51 04/07/2023 21:28:12 43475587 43475587 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 01/01/2000 01:03:48 04/07/2023 21:26:08 43475587 43475587 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
<-- Retour resume 43475587