KRM_SERVER 10/09/2025 15:45:02 10/09/2025 15:45:02 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 09/09/2025 15:45:03 09/09/2025 15:45:03 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 08/09/2025 15:45:04 08/09/2025 15:45:04 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 07/09/2025 15:45:05 07/09/2025 15:45:05 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 06/09/2025 15:45:07 06/09/2025 15:45:07 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 05/09/2025 15:45:12 05/09/2025 15:45:12 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 04/09/2025 15:46:45 04/09/2025 15:46:45 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 04/09/2025 15:45:09 04/09/2025 15:45:09 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 03/09/2025 15:46:52 03/09/2025 15:46:52 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 02/09/2025 15:46:54 02/09/2025 15:46:54 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 01/09/2025 15:46:55 01/09/2025 15:46:55 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 31/08/2025 15:46:56 31/08/2025 15:46:56 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 30/08/2025 15:46:57 30/08/2025 15:46:57 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 29/08/2025 15:46:59 29/08/2025 15:46:59 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 28/08/2025 15:47:00 28/08/2025 15:47:00 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 27/08/2025 15:47:01 27/08/2025 15:47:01 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 26/08/2025 15:47:03 26/08/2025 15:47:03 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 25/08/2025 22:29:58 25/08/2025 22:29:58 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 25/08/2025 15:47:03 25/08/2025 15:47:03 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 24/08/2025 15:47:04 24/08/2025 15:47:04 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 23/08/2025 15:47:05 23/08/2025 15:47:06 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 22/08/2025 15:47:06 22/08/2025 15:47:06 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 21/08/2025 15:47:09 21/08/2025 15:47:09 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 20/08/2025 15:47:09 20/08/2025 15:47:09 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 19/08/2025 15:47:09 19/08/2025 15:47:09 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 18/08/2025 15:47:11 18/08/2025 15:47:11 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 17/08/2025 15:47:12 17/08/2025 15:47:13 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 16/08/2025 15:47:14 16/08/2025 15:47:14 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 15/08/2025 15:47:15 15/08/2025 15:47:15 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 14/08/2025 15:47:15 14/08/2025 15:47:15 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 13/08/2025 15:47:17 13/08/2025 15:47:18 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 12/08/2025 15:47:19 12/08/2025 15:47:19 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 11/08/2025 15:47:19 11/08/2025 15:47:19 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 10/08/2025 15:47:21 10/08/2025 15:47:21 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 07/08/2025 19:22:44 07/08/2025 19:22:47 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 07/08/2025 19:22:44 07/08/2025 19:22:52 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 04/08/2025 15:44:53 04/08/2025 15:44:53 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 03/08/2025 15:44:54 03/08/2025 15:44:54 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 02/08/2025 15:44:56 02/08/2025 15:44:56 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 01/08/2025 15:44:56 01/08/2025 15:44:56 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 31/07/2025 15:44:58 31/07/2025 15:44:58 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 30/07/2025 15:44:59 30/07/2025 15:44:59 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 29/07/2025 15:45:00 29/07/2025 15:45:00 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 28/07/2025 15:45:01 28/07/2025 15:45:01 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 27/07/2025 15:45:03 27/07/2025 15:45:03 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 26/07/2025 15:45:04 26/07/2025 15:45:04 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 25/07/2025 15:45:06 25/07/2025 15:45:07 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 24/07/2025 15:45:07 24/07/2025 15:45:07 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 23/07/2025 15:46:16 23/07/2025 15:46:16 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 23/07/2025 15:44:42 23/07/2025 15:44:42 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 22/07/2025 15:44:44 22/07/2025 15:44:44 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 19/07/2025 15:44:46 19/07/2025 15:44:46 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 18/07/2025 15:45:59 18/07/2025 15:45:59 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 18/07/2025 15:44:48 18/07/2025 15:44:48 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 17/07/2025 15:44:49 17/07/2025 15:44:49 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 16/07/2025 15:44:50 16/07/2025 15:44:50 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 15/07/2025 15:44:51 15/07/2025 15:44:51 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 14/07/2025 15:44:57 14/07/2025 15:44:57 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 13/07/2025 15:44:54 13/07/2025 15:44:54 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 12/07/2025 15:44:56 12/07/2025 15:44:56 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 10/07/2025 15:44:57 10/07/2025 15:44:58 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 09/07/2025 15:44:59 09/07/2025 15:44:59 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 08/07/2025 15:45:00 08/07/2025 15:45:00 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 07/07/2025 15:45:02 07/07/2025 15:45:02 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 06/07/2025 15:45:02 06/07/2025 15:45:02 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 05/07/2025 15:45:04 05/07/2025 15:45:04 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 04/07/2025 15:45:05 04/07/2025 15:45:05 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 03/07/2025 15:45:06 03/07/2025 15:45:06 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 02/07/2025 15:44:42 02/07/2025 15:44:42 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 01/07/2025 15:44:43 01/07/2025 15:44:44 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 30/06/2025 15:44:43 30/06/2025 15:44:43 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 29/06/2025 15:46:18 29/06/2025 15:46:18 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 29/06/2025 15:44:44 29/06/2025 15:44:44 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 28/06/2025 15:44:47 28/06/2025 15:44:47 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 27/06/2025 15:44:51 27/06/2025 15:44:51 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 26/06/2025 15:44:49 26/06/2025 15:44:49 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 25/06/2025 15:44:49 25/06/2025 15:44:49 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 24/06/2025 15:44:50 24/06/2025 15:44:50 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 23/06/2025 15:44:53 23/06/2025 15:44:53 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 22/06/2025 15:44:53 22/06/2025 15:44:54 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 21/06/2025 15:44:59 21/06/2025 15:44:59 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 20/06/2025 15:44:55 20/06/2025 15:44:55 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 19/06/2025 15:44:57 19/06/2025 15:44:57 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 18/06/2025 15:44:59 18/06/2025 15:44:59 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 17/06/2025 15:45:00 17/06/2025 15:45:00 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 16/06/2025 15:45:00 16/06/2025 15:45:01 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 15/06/2025 15:45:01 15/06/2025 15:45:01 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 13/06/2025 15:45:04 13/06/2025 15:45:04 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 12/06/2025 15:45:05 12/06/2025 15:45:05 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 11/06/2025 15:45:07 11/06/2025 15:45:07 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 10/06/2025 15:44:22 10/06/2025 15:44:22 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 09/06/2025 15:44:25 09/06/2025 15:44:25 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 08/06/2025 15:44:25 08/06/2025 15:44:25 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 07/06/2025 15:44:26 07/06/2025 15:44:26 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 06/06/2025 15:44:27 06/06/2025 15:44:27 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 05/06/2025 15:44:29 05/06/2025 15:44:30 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 04/06/2025 15:44:30 04/06/2025 15:44:30 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 03/06/2025 15:44:31 03/06/2025 15:44:31 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 02/06/2025 15:44:32 02/06/2025 15:44:32 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 01/06/2025 15:44:34 01/06/2025 15:44:34 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 31/05/2025 15:44:35 31/05/2025 15:44:35 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 30/05/2025 15:44:36 30/05/2025 15:44:36 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 29/05/2025 15:44:38 29/05/2025 15:44:38 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 28/05/2025 15:44:39 28/05/2025 15:44:39 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 27/05/2025 15:44:40 27/05/2025 15:44:40 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 26/05/2025 15:44:42 26/05/2025 15:44:42 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 25/05/2025 15:44:43 25/05/2025 15:44:43 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 24/05/2025 15:44:44 24/05/2025 15:44:44 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 23/05/2025 15:44:45 23/05/2025 15:44:45 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 22/05/2025 15:44:47 22/05/2025 15:44:47 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 21/05/2025 15:44:49 21/05/2025 15:44:49 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 20/05/2025 15:44:49 20/05/2025 15:44:49 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 19/05/2025 15:44:50 19/05/2025 15:44:50 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 18/05/2025 15:44:52 18/05/2025 15:44:52 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 17/05/2025 15:44:53 17/05/2025 15:44:53 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 16/05/2025 15:44:54 16/05/2025 15:44:54 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 15/05/2025 15:44:55 15/05/2025 15:44:55 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 14/05/2025 15:44:58 14/05/2025 15:44:58 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 13/05/2025 15:44:58 13/05/2025 15:44:58 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 12/05/2025 15:46:33 12/05/2025 15:46:33 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 12/05/2025 15:44:59 12/05/2025 15:44:59 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 07/05/2025 15:45:07 07/05/2025 15:45:07 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 06/05/2025 15:45:13 06/05/2025 15:45:13 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 05/05/2025 14:46:18 05/05/2025 14:46:18 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 04/05/2025 14:46:19 04/05/2025 14:46:19 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 03/05/2025 14:46:21 03/05/2025 14:46:21 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 02/05/2025 14:46:27 02/05/2025 14:46:27 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 01/05/2025 14:46:22 01/05/2025 14:46:22 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 30/04/2025 14:49:19 30/04/2025 14:49:19 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 29/04/2025 14:46:25 29/04/2025 14:46:25 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 28/04/2025 14:46:27 28/04/2025 14:46:27 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 27/04/2025 14:46:31 27/04/2025 14:46:31 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 26/04/2025 14:46:28 26/04/2025 14:46:28 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 25/04/2025 14:46:30 25/04/2025 14:46:30 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 24/04/2025 14:46:31 24/04/2025 14:46:31 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 23/04/2025 14:46:33 23/04/2025 14:46:33 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 22/04/2025 14:46:35 22/04/2025 14:46:35 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 02/12/2024 16:46:25 02/12/2024 16:46:26 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 02/12/2024 15:46:25 02/12/2024 15:46:26 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 01/12/2024 16:51:30 01/12/2024 16:51:30 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 01/12/2024 15:51:30 01/12/2024 15:51:30 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 30/11/2024 16:46:39 30/11/2024 16:46:39 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 30/11/2024 15:46:39 30/11/2024 15:46:39 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 29/11/2024 15:46:34 29/11/2024 15:46:34 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 28/11/2024 15:51:06 28/11/2024 15:51:06 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 28/11/2024 15:48:23 28/11/2024 15:48:23 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 28/11/2024 15:46:39 28/11/2024 15:46:40 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 27/11/2024 16:21:50 27/11/2024 16:21:50 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 27/11/2024 15:50:57 27/11/2024 15:50:57 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 27/11/2024 15:48:23 27/11/2024 15:48:23 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 27/11/2024 15:46:47 27/11/2024 15:46:48 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 26/11/2024 15:46:42 26/11/2024 15:46:42 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 26/11/2024 14:55:00 26/11/2024 14:55:01 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 26/11/2024 13:55:58 26/11/2024 12:52:33 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 26/11/2024 13:55:40 26/11/2024 12:52:20 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 26/11/2024 07:52:06 26/11/2024 07:52:10 43731847 43731847 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 26/11/2024 05:35:16 26/11/2024 05:35:16 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 24/11/2024 14:44:55 24/11/2024 14:44:56 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 23/11/2024 15:03:25 23/11/2024 15:03:25 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 22/11/2024 14:44:58 22/11/2024 14:44:58 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 21/11/2024 14:45:03 21/11/2024 14:45:04 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 20/11/2024 14:45:12 20/11/2024 14:45:12 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 19/11/2024 14:45:16 19/11/2024 14:45:17 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 18/11/2024 14:45:13 18/11/2024 14:45:14 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 17/11/2024 14:45:10 17/11/2024 14:45:11 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 16/11/2024 14:49:32 16/11/2024 14:49:33 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 16/11/2024 14:46:48 16/11/2024 14:46:49 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 16/11/2024 14:45:12 16/11/2024 14:45:13 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 11/11/2024 14:44:47 11/11/2024 14:44:48 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 10/11/2024 14:44:49 10/11/2024 14:44:50 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 09/11/2024 14:48:40 09/11/2024 14:48:40 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 08/11/2024 14:44:52 08/11/2024 14:44:53 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 07/11/2024 14:45:01 07/11/2024 14:45:01 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 06/11/2024 14:49:13 06/11/2024 14:49:14 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 06/11/2024 14:46:38 06/11/2024 14:46:38 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 06/11/2024 14:44:55 06/11/2024 14:44:55 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 05/11/2024 14:44:56 05/11/2024 14:44:56 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 04/11/2024 14:44:55 04/11/2024 14:44:55 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 03/11/2024 14:44:58 03/11/2024 14:44:58 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 02/11/2024 14:45:00 02/11/2024 14:45:01 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 01/11/2024 14:45:00 01/11/2024 14:45:00 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 31/10/2024 14:49:23 31/10/2024 14:49:23 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 31/10/2024 14:46:46 31/10/2024 14:46:47 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 31/10/2024 14:45:10 31/10/2024 14:45:11 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 30/10/2024 15:02:16 30/10/2024 15:02:16 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 30/10/2024 14:46:44 30/10/2024 14:46:44 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 30/10/2024 14:45:03 30/10/2024 14:45:03 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 29/10/2024 15:19:27 29/10/2024 15:19:27 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 29/10/2024 14:49:45 29/10/2024 14:49:45 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 29/10/2024 14:47:05 29/10/2024 14:47:05 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 29/10/2024 14:45:17 29/10/2024 14:45:17 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 28/10/2024 14:45:29 28/10/2024 14:45:29 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 27/10/2024 15:46:24 27/10/2024 15:46:25 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 26/10/2024 15:46:40 26/10/2024 15:46:40 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 25/10/2024 15:44:48 25/10/2024 15:44:48 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 24/10/2024 15:46:21 24/10/2024 15:46:21 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 24/10/2024 15:44:44 24/10/2024 15:44:45 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 23/10/2024 15:44:44 23/10/2024 15:44:44 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 22/10/2024 15:48:53 22/10/2024 15:48:54 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 22/10/2024 15:46:40 22/10/2024 15:46:41 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 22/10/2024 15:44:54 22/10/2024 15:44:55 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 21/10/2024 15:44:48 21/10/2024 15:44:49 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 20/10/2024 15:44:48 20/10/2024 15:44:48 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 19/10/2024 15:44:49 19/10/2024 15:44:49 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 18/10/2024 15:44:51 18/10/2024 15:44:51 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 17/10/2024 15:44:51 17/10/2024 15:44:52 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 16/10/2024 15:46:33 16/10/2024 15:46:33 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 16/10/2024 15:44:53 16/10/2024 15:44:54 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 15/10/2024 15:49:14 15/10/2024 15:49:15 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 15/10/2024 15:46:30 15/10/2024 15:46:31 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 15/10/2024 15:44:54 15/10/2024 15:44:55 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 14/10/2024 15:48:54 14/10/2024 15:48:54 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 13/10/2024 15:44:56 13/10/2024 15:44:56 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 12/10/2024 15:44:57 12/10/2024 15:44:58 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 11/10/2024 15:44:59 11/10/2024 15:45:00 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 10/10/2024 15:00:14 10/10/2024 15:00:17 43731847 43731847 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/10/2024 15:00:14 10/10/2024 15:01:50 43731847 43731847 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/10/2024 14:02:57 10/10/2024 14:02:59 43731847 43731847 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/10/2024 14:02:57 10/10/2024 14:10:24 43731847 43731847 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/10/2024 14:02:49 10/10/2024 14:02:51 43731847 43731847 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/10/2024 14:02:49 10/10/2024 14:10:29 43731847 43731847 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/10/2024 15:55:00 09/10/2024 15:55:00 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 09/10/2024 15:50:10 09/10/2024 15:50:10 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 08/10/2024 15:45:04 08/10/2024 15:45:04 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 07/10/2024 15:48:39 07/10/2024 15:48:39 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 06/10/2024 15:45:06 06/10/2024 15:45:06 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 05/10/2024 15:45:08 05/10/2024 15:45:08 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 04/10/2024 15:46:07 04/10/2024 15:46:08 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 03/10/2024 15:44:44 03/10/2024 15:44:44 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 02/10/2024 15:44:54 02/10/2024 15:44:55 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 01/10/2024 15:53:31 01/10/2024 15:53:32 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 01/10/2024 15:48:58 01/10/2024 15:48:59 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 01/10/2024 15:46:23 01/10/2024 15:46:23 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 01/10/2024 15:44:47 01/10/2024 15:44:48 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 30/09/2024 15:44:48 30/09/2024 15:44:48 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 29/09/2024 15:44:49 29/09/2024 15:44:49 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 28/09/2024 15:44:51 28/09/2024 15:44:52 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 27/09/2024 15:44:52 27/09/2024 15:44:52 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 26/09/2024 15:44:57 26/09/2024 15:44:58 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 25/09/2024 15:46:53 25/09/2024 15:46:53 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 25/09/2024 15:45:02 25/09/2024 15:45:02 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 24/09/2024 15:46:39 24/09/2024 15:46:39 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 24/09/2024 15:44:56 24/09/2024 15:44:56 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 23/09/2024 15:44:57 23/09/2024 15:44:57 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 22/09/2024 15:44:59 22/09/2024 15:45:00 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 21/09/2024 15:45:00 21/09/2024 15:45:00 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 20/09/2024 15:45:01 20/09/2024 15:45:02 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 19/09/2024 15:45:02 19/09/2024 15:45:02 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 18/09/2024 15:46:39 18/09/2024 15:46:39 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 18/09/2024 15:45:04 18/09/2024 15:45:04 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 17/09/2024 15:46:55 17/09/2024 15:46:58 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 17/09/2024 15:46:55 17/09/2024 15:47:04 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 17/09/2024 15:46:55 17/09/2024 15:47:10 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 17/09/2024 15:46:45 17/09/2024 15:46:46 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 17/09/2024 15:45:09 17/09/2024 15:45:10 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 16/09/2024 15:46:48 16/09/2024 15:46:48 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 16/09/2024 15:45:07 16/09/2024 15:45:07 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 15/09/2024 15:45:07 15/09/2024 15:45:07 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 14/09/2024 15:45:07 14/09/2024 15:45:08 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 13/09/2024 15:45:26 13/09/2024 15:45:26 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 12/09/2024 15:45:29 12/09/2024 15:45:29 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 12/09/2024 15:44:43 12/09/2024 15:44:44 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 12/09/2024 11:03:12 12/09/2024 09:02:41 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 12/09/2024 11:02:34 12/09/2024 09:03:06 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 11/09/2024 15:44:46 11/09/2024 15:44:46 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 10/09/2024 15:44:47 10/09/2024 15:44:47 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 09/09/2024 15:44:50 09/09/2024 15:44:50 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 08/09/2024 15:44:49 08/09/2024 15:44:49 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 07/09/2024 15:44:51 07/09/2024 15:44:51 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 06/09/2024 15:44:51 06/09/2024 15:44:51 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 05/09/2024 15:44:53 05/09/2024 15:44:53 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 04/09/2024 15:44:53 04/09/2024 15:44:53 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 03/09/2024 15:44:54 03/09/2024 15:44:55 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 02/09/2024 15:44:57 02/09/2024 15:44:57 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 01/09/2024 15:44:56 01/09/2024 15:44:57 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 31/08/2024 15:45:03 31/08/2024 15:45:04 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 30/08/2024 15:46:29 30/08/2024 15:46:30 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 29/08/2024 15:45:00 29/08/2024 15:45:01 43731847 43731847 1,0 Cyclic Call Reception
KRM_SERVER 28/08/2024 15:45:03 28/08/2024 15:45:03 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 27/08/2024 15:45:03 27/08/2024 15:45:03 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 26/08/2024 15:45:05 26/08/2024 15:45:05 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 25/08/2024 15:45:06 25/08/2024 15:45:06 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 24/08/2024 15:45:06 24/08/2024 15:45:07 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 23/08/2024 15:45:16 23/08/2024 15:45:17 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 22/08/2024 15:45:18 22/08/2024 15:45:19 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 21/08/2024 15:45:20 21/08/2024 15:45:20 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 20/08/2024 15:45:21 20/08/2024 15:45:22 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 19/08/2024 15:45:21 19/08/2024 15:45:21 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 18/08/2024 22:25:17 18/08/2024 22:25:19 43731847 43731847 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 18/08/2024 22:25:17 18/08/2024 22:25:58 43731847 43731847 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 18/08/2024 15:45:23 18/08/2024 15:45:23 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 17/08/2024 15:45:25 17/08/2024 15:45:25 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 16/08/2024 15:45:25 16/08/2024 15:45:25 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 15/08/2024 15:45:27 15/08/2024 15:45:27 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 14/08/2024 15:45:28 14/08/2024 15:45:28 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 13/08/2024 15:45:29 13/08/2024 15:45:29 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 12/08/2024 15:45:32 12/08/2024 15:45:32 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 11/08/2024 15:45:31 11/08/2024 15:45:32 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 10/08/2024 15:45:32 10/08/2024 15:45:32 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 09/08/2024 15:45:33 09/08/2024 15:45:34 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 08/08/2024 15:45:35 08/08/2024 15:45:35 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 07/08/2024 15:45:35 07/08/2024 15:45:35 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 06/08/2024 15:45:37 06/08/2024 15:45:37 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 06/08/2024 15:45:02 06/08/2024 15:45:02 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 05/08/2024 19:22:27 05/08/2024 17:22:09 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 05/08/2024 18:09:08 05/08/2024 16:08:50 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 05/08/2024 15:45:04 05/08/2024 15:45:04 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 04/08/2024 15:45:06 04/08/2024 15:45:06 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 03/08/2024 15:46:28 03/08/2024 15:46:28 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 02/08/2024 15:44:41 02/08/2024 15:44:41 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 01/08/2024 15:44:42 01/08/2024 15:44:43 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 31/07/2024 15:44:43 31/07/2024 15:44:43 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 30/07/2024 15:44:45 30/07/2024 15:44:46 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 29/07/2024 15:44:46 29/07/2024 15:44:47 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 28/07/2024 15:46:10 28/07/2024 15:46:11 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 27/07/2024 15:44:49 27/07/2024 15:44:49 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 26/07/2024 15:44:49 26/07/2024 15:44:49 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 25/07/2024 15:44:51 25/07/2024 15:44:52 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 24/07/2024 15:44:52 24/07/2024 15:44:52 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 23/07/2024 15:46:16 23/07/2024 15:46:16 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 22/07/2024 15:44:58 22/07/2024 15:44:58 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 21/07/2024 15:44:55 21/07/2024 15:44:55 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 20/07/2024 15:44:56 20/07/2024 15:44:57 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 19/07/2024 15:44:58 19/07/2024 15:44:59 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 18/07/2024 15:44:59 18/07/2024 15:44:59 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 17/07/2024 15:45:00 17/07/2024 15:45:01 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 16/07/2024 15:45:01 16/07/2024 15:45:01 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 15/07/2024 15:45:03 15/07/2024 15:45:03 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 14/07/2024 15:45:04 14/07/2024 15:45:04 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 12/07/2024 15:45:06 12/07/2024 15:45:06 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 11/07/2024 15:45:34 11/07/2024 15:45:34 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 10/07/2024 17:52:40 10/07/2024 17:52:40 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 10/07/2024 15:45:36 10/07/2024 15:45:37 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 09/07/2024 15:47:03 09/07/2024 15:47:04 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 08/07/2024 15:45:38 08/07/2024 15:45:39 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 07/07/2024 15:45:40 07/07/2024 15:45:40 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 06/07/2024 15:45:41 06/07/2024 15:45:41 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 05/07/2024 15:48:13 05/07/2024 15:48:13 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 04/07/2024 15:45:43 04/07/2024 15:45:44 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 03/07/2024 15:45:44 03/07/2024 15:45:44 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 02/07/2024 15:45:49 02/07/2024 15:45:49 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 01/07/2024 15:45:48 01/07/2024 15:45:48 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 30/06/2024 15:45:48 30/06/2024 15:45:49 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 29/06/2024 15:45:50 29/06/2024 15:45:51 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 29/06/2024 01:34:22 28/06/2024 23:34:07 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/06/2024 23:34:22 28/06/2024 21:34:07 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/06/2024 21:34:22 28/06/2024 19:34:07 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/06/2024 19:34:22 28/06/2024 17:34:07 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/06/2024 17:34:22 28/06/2024 15:34:07 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/06/2024 15:34:22 28/06/2024 13:34:07 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 27/06/2024 15:45:05 27/06/2024 15:45:05 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 26/06/2024 15:45:01 26/06/2024 15:45:02 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 25/06/2024 15:45:03 25/06/2024 15:45:03 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 24/06/2024 15:45:04 24/06/2024 15:45:05 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 23/06/2024 15:45:05 23/06/2024 15:45:06 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 22/06/2024 15:45:07 22/06/2024 15:45:07 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 21/06/2024 15:45:08 21/06/2024 15:45:08 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 20/06/2024 15:44:42 20/06/2024 15:44:42 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 19/06/2024 15:44:42 19/06/2024 15:44:43 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 18/06/2024 15:44:44 18/06/2024 15:44:44 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 17/06/2024 15:44:46 17/06/2024 15:44:46 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 16/06/2024 15:44:45 16/06/2024 15:44:45 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 15/06/2024 15:44:47 15/06/2024 15:44:47 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 14/06/2024 15:44:50 14/06/2024 15:44:50 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 13/06/2024 15:44:55 13/06/2024 15:44:55 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 12/06/2024 15:44:50 12/06/2024 15:44:50 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 11/06/2024 15:44:53 11/06/2024 15:44:54 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 10/06/2024 15:44:54 10/06/2024 15:44:54 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 09/06/2024 15:44:56 09/06/2024 15:44:56 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 08/06/2024 15:45:00 08/06/2024 15:45:01 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 07/06/2024 15:44:57 07/06/2024 15:44:57 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 06/06/2024 15:44:59 06/06/2024 15:44:59 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 05/06/2024 15:45:00 05/06/2024 15:45:01 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 04/06/2024 15:45:02 04/06/2024 15:45:03 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 03/06/2024 15:45:04 03/06/2024 15:45:04 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 02/06/2024 15:45:05 02/06/2024 15:45:05 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 01/06/2024 15:45:06 01/06/2024 15:45:06 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 31/05/2024 15:45:07 31/05/2024 15:45:08 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 30/05/2024 14:46:49 30/05/2024 14:46:49 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 29/05/2024 14:46:50 29/05/2024 14:46:50 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 28/05/2024 16:45:10 28/05/2024 14:45:27 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 15:44:46 28/05/2024 15:44:46 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 28/05/2024 15:21:51 28/05/2024 13:22:08 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 14:45:10 28/05/2024 12:45:27 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 14:23:14 28/05/2024 13:21:25 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 14:22:53 28/05/2024 13:20:58 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 13:21:51 28/05/2024 11:22:08 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 12:45:10 28/05/2024 10:45:27 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 12:23:14 28/05/2024 11:21:25 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 12:22:53 28/05/2024 11:20:58 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 11:21:51 28/05/2024 09:22:08 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 10:45:10 28/05/2024 08:45:27 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 10:23:14 28/05/2024 09:21:25 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 10:22:53 28/05/2024 09:20:58 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 09:21:51 28/05/2024 07:22:08 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 08:45:10 28/05/2024 06:45:27 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 08:23:14 28/05/2024 07:21:25 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 08:22:53 28/05/2024 07:20:58 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 07:21:51 28/05/2024 05:22:08 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 06:23:14 28/05/2024 05:21:25 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 28/05/2024 06:22:53 28/05/2024 05:20:58 43731847 43731847 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 27/05/2024 15:44:52 27/05/2024 15:44:52 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 26/05/2024 15:44:49 26/05/2024 15:44:49 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 25/05/2024 15:44:49 25/05/2024 15:44:50 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 24/05/2024 23:19:18 24/05/2024 23:19:24 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/05/2024 23:19:18 24/05/2024 23:19:30 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 24/05/2024 23:19:18 24/05/2024 23:19:36 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/05/2024 23:19:18 24/05/2024 23:19:42 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 24/05/2024 21:19:18 24/05/2024 21:19:24 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/05/2024 21:19:18 24/05/2024 21:19:30 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 24/05/2024 21:19:18 24/05/2024 21:19:36 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/05/2024 21:19:18 24/05/2024 21:19:42 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 24/05/2024 19:19:18 24/05/2024 19:19:24 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/05/2024 19:19:18 24/05/2024 19:19:30 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 24/05/2024 19:19:18 24/05/2024 19:19:36 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/05/2024 19:19:18 24/05/2024 19:19:42 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 24/05/2024 17:19:18 24/05/2024 17:19:24 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/05/2024 17:19:18 24/05/2024 17:19:30 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 24/05/2024 17:19:18 24/05/2024 17:19:36 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/05/2024 17:19:18 24/05/2024 17:19:42 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 24/05/2024 15:44:51 24/05/2024 15:44:51 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 24/05/2024 15:19:18 24/05/2024 15:19:24 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/05/2024 15:19:18 24/05/2024 15:19:30 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 24/05/2024 15:19:18 24/05/2024 15:19:36 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/05/2024 15:19:18 24/05/2024 15:19:42 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 23/05/2024 15:44:53 23/05/2024 15:44:53 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 22/05/2024 15:44:53 22/05/2024 15:44:53 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 21/05/2024 15:44:55 21/05/2024 15:44:55 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 20/05/2024 15:44:55 20/05/2024 15:44:56 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 19/05/2024 15:44:56 19/05/2024 15:44:57 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 18/05/2024 15:44:58 18/05/2024 15:44:59 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 17/05/2024 15:44:59 17/05/2024 15:45:00 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 16/05/2024 15:45:00 16/05/2024 15:45:01 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 15/05/2024 15:45:01 15/05/2024 15:45:02 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 14/05/2024 15:45:03 14/05/2024 15:45:04 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 13/05/2024 15:45:04 13/05/2024 15:45:05 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 12/05/2024 15:45:06 12/05/2024 15:45:06 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 11/05/2024 15:45:06 11/05/2024 15:45:06 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 10/05/2024 15:45:08 10/05/2024 15:45:09 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 09/05/2024 15:44:40 09/05/2024 15:44:41 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 08/05/2024 15:44:42 08/05/2024 15:44:42 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 07/05/2024 15:44:44 07/05/2024 15:44:44 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 06/05/2024 15:44:45 06/05/2024 15:44:45 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 05/05/2024 15:44:46 05/05/2024 15:44:46 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 04/05/2024 15:44:48 04/05/2024 15:44:48 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 03/05/2024 15:44:48 03/05/2024 15:44:49 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 02/05/2024 15:44:51 02/05/2024 15:44:51 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 01/05/2024 15:44:51 01/05/2024 15:44:51 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 30/04/2024 15:44:52 30/04/2024 15:44:52 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 29/04/2024 15:44:54 29/04/2024 15:44:54 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 28/04/2024 15:44:54 28/04/2024 15:44:55 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 27/04/2024 15:44:56 27/04/2024 15:44:56 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 26/04/2024 15:45:02 26/04/2024 15:45:03 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 25/04/2024 15:44:59 25/04/2024 15:44:59 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 24/04/2024 15:45:01 24/04/2024 15:45:01 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 24/04/2024 06:09:47 24/04/2024 06:09:52 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/04/2024 06:09:47 24/04/2024 06:09:58 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 24/04/2024 06:09:47 24/04/2024 06:10:04 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/04/2024 06:09:47 24/04/2024 06:10:10 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 24/04/2024 04:09:47 24/04/2024 04:09:52 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/04/2024 04:09:47 24/04/2024 04:09:58 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 24/04/2024 04:09:47 24/04/2024 04:10:04 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/04/2024 04:09:47 24/04/2024 04:10:10 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 24/04/2024 02:09:47 24/04/2024 02:09:52 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/04/2024 02:09:47 24/04/2024 02:09:58 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 24/04/2024 02:09:47 24/04/2024 02:10:04 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/04/2024 02:09:47 24/04/2024 02:10:10 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 24/04/2024 00:09:47 24/04/2024 00:09:52 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/04/2024 00:09:47 24/04/2024 00:09:58 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 24/04/2024 00:09:47 24/04/2024 00:10:04 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 24/04/2024 00:09:47 24/04/2024 00:10:10 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 23/04/2024 15:45:02 23/04/2024 15:45:02 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 22/04/2024 15:45:08 22/04/2024 15:45:08 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 21/04/2024 15:45:05 21/04/2024 15:45:05 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 20/04/2024 15:45:06 20/04/2024 15:45:06 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 19/04/2024 15:45:08 19/04/2024 15:45:08 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 18/04/2024 15:44:40 18/04/2024 15:44:41 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 17/04/2024 15:44:43 17/04/2024 15:44:43 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 16/04/2024 15:44:44 16/04/2024 15:44:44 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 15/04/2024 15:44:44 15/04/2024 15:44:44 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 14/04/2024 15:44:45 14/04/2024 15:44:46 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 13/04/2024 15:44:47 13/04/2024 15:44:48 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 12/04/2024 15:44:48 12/04/2024 15:44:49 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 11/04/2024 15:44:49 11/04/2024 15:44:50 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 10/04/2024 15:44:51 10/04/2024 15:44:51 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 09/04/2024 15:44:52 09/04/2024 15:44:53 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 08/04/2024 15:44:53 08/04/2024 15:44:54 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 07/04/2024 15:44:55 07/04/2024 15:44:56 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 06/04/2024 15:44:57 06/04/2024 15:44:57 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 05/04/2024 15:44:57 05/04/2024 15:44:57 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 04/04/2024 15:44:59 04/04/2024 15:45:00 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 03/04/2024 15:45:00 03/04/2024 15:45:00 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 02/04/2024 15:45:02 02/04/2024 15:45:02 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 01/04/2024 15:45:02 01/04/2024 15:45:03 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 31/03/2024 15:45:07 31/03/2024 15:45:08 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 30/03/2024 19:15:19 30/03/2024 19:15:24 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 30/03/2024 19:15:19 30/03/2024 19:15:30 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 30/03/2024 19:15:19 30/03/2024 19:15:36 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 30/03/2024 17:15:19 30/03/2024 17:15:24 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 30/03/2024 17:15:19 30/03/2024 17:15:30 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 30/03/2024 17:15:19 30/03/2024 17:15:36 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 30/03/2024 15:45:06 30/03/2024 15:45:06 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 30/03/2024 15:15:19 30/03/2024 15:15:24 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 30/03/2024 15:15:19 30/03/2024 15:15:30 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 30/03/2024 15:15:19 30/03/2024 15:15:36 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 29/03/2024 15:46:40 29/03/2024 15:46:40 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 29/03/2024 15:45:07 29/03/2024 15:45:07 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 28/03/2024 15:44:40 28/03/2024 15:44:41 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 27/03/2024 15:44:42 27/03/2024 15:44:42 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 26/03/2024 15:44:43 26/03/2024 15:44:44 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 25/03/2024 15:44:44 25/03/2024 15:44:45 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 24/03/2024 14:44:46 24/03/2024 14:44:47 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 23/03/2024 14:44:47 23/03/2024 14:44:48 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 22/03/2024 14:44:49 22/03/2024 14:44:49 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 21/03/2024 14:44:49 21/03/2024 14:44:49 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 20/03/2024 14:44:52 20/03/2024 14:44:52 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 19/03/2024 14:44:51 19/03/2024 14:44:52 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 18/03/2024 14:44:53 18/03/2024 14:44:54 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 17/03/2024 14:44:55 17/03/2024 14:44:56 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 16/03/2024 14:44:57 16/03/2024 14:44:57 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 15/03/2024 14:46:31 15/03/2024 14:46:31 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 15/03/2024 14:44:56 15/03/2024 14:44:56 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 14/03/2024 14:44:59 14/03/2024 14:45:00 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 13/03/2024 14:45:00 13/03/2024 14:45:00 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 12/03/2024 14:45:02 12/03/2024 14:45:03 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 11/03/2024 14:45:02 11/03/2024 14:45:03 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 10/03/2024 14:45:08 10/03/2024 14:45:08 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 09/03/2024 14:45:06 09/03/2024 14:45:07 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 08/03/2024 14:45:07 08/03/2024 14:45:07 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 07/03/2024 14:45:02 07/03/2024 14:45:02 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 06/03/2024 14:45:05 06/03/2024 14:45:05 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 05/03/2024 14:45:06 05/03/2024 14:45:06 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 04/03/2024 14:45:08 04/03/2024 14:45:08 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 03/03/2024 14:45:10 03/03/2024 14:45:10 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 02/03/2024 14:45:11 02/03/2024 14:45:11 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 01/03/2024 14:45:12 01/03/2024 14:45:12 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 29/02/2024 14:45:14 29/02/2024 14:45:14 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 28/02/2024 14:45:15 28/02/2024 14:45:15 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 27/02/2024 14:45:15 27/02/2024 14:45:16 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 26/02/2024 14:45:18 26/02/2024 14:45:18 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 25/02/2024 14:45:18 25/02/2024 14:45:18 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 24/02/2024 14:45:19 24/02/2024 14:45:19 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 24/02/2024 02:14:28 24/02/2024 02:14:28 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 22/02/2024 14:46:34 22/02/2024 14:46:35 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 22/02/2024 14:45:01 22/02/2024 14:45:01 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 21/02/2024 14:45:00 21/02/2024 14:45:01 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 20/02/2024 14:45:06 20/02/2024 14:45:06 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 19/02/2024 14:45:06 19/02/2024 14:45:06 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 18/02/2024 14:45:05 18/02/2024 14:45:05 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 17/02/2024 14:45:05 17/02/2024 14:45:06 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 16/02/2024 14:45:08 16/02/2024 14:45:08 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 15/02/2024 14:44:57 15/02/2024 14:44:57 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 14/02/2024 14:44:58 14/02/2024 14:44:58 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 13/02/2024 14:44:59 13/02/2024 14:44:59 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 12/02/2024 14:45:02 12/02/2024 17:15:07 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 11/02/2024 14:45:02 11/02/2024 14:45:02 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 10/02/2024 14:45:07 10/02/2024 14:45:07 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 09/02/2024 14:45:05 09/02/2024 14:45:05 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 08/02/2024 14:45:06 08/02/2024 14:45:06 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 07/02/2024 14:45:08 07/02/2024 14:45:08 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 06/02/2024 14:45:14 06/02/2024 14:45:14 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 05/02/2024 15:37:20 05/02/2024 14:37:43 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 15:37:13 05/02/2024 14:37:29 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 15:31:53 05/02/2024 14:32:01 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 15:31:47 05/02/2024 14:31:53 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 15:27:32 05/02/2024 14:27:38 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 15:27:24 05/02/2024 14:27:29 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 15:22:34 05/02/2024 14:22:49 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 15:22:28 05/02/2024 14:22:43 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 14:54:53 05/02/2024 13:54:51 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 14:54:43 05/02/2024 13:55:04 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 14:48:38 05/02/2024 14:48:38 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 05/02/2024 14:37:20 05/02/2024 13:37:43 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 14:37:13 05/02/2024 13:37:29 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 14:31:53 05/02/2024 13:32:01 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 14:31:47 05/02/2024 13:31:53 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 14:27:32 05/02/2024 13:27:38 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 14:27:24 05/02/2024 13:27:29 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 14:24:59 05/02/2024 14:25:45 43731847 43731847 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 05/02/2024 14:24:59 05/02/2024 14:25:52 43731847 43731847 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 05/02/2024 14:24:59 05/02/2024 14:25:58 43731847 43731847 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 05/02/2024 14:24:59 05/02/2024 14:26:05 43731847 43731847 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 05/02/2024 14:22:34 05/02/2024 13:22:49 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 14:22:28 05/02/2024 13:22:43 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 14:16:47 05/02/2024 14:16:56 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 14:16:47 05/02/2024 14:17:03 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 14:16:47 05/02/2024 14:17:09 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 14:16:47 05/02/2024 14:17:15 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 14:16:47 05/02/2024 14:17:22 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 14:16:47 05/02/2024 14:17:33 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 14:16:47 05/02/2024 14:18:56 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 14:16:47 05/02/2024 14:19:02 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 14:16:47 05/02/2024 14:19:09 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 14:16:47 05/02/2024 14:19:15 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 14:16:47 05/02/2024 14:19:22 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 14:16:47 05/02/2024 14:19:28 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 14:16:47 05/02/2024 14:19:35 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 14:16:47 05/02/2024 14:19:41 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 14:08:18 05/02/2024 14:08:26 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 14:08:18 05/02/2024 14:08:33 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 14:08:18 05/02/2024 14:08:39 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 14:08:18 05/02/2024 14:08:46 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 14:08:18 05/02/2024 14:08:52 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 14:08:18 05/02/2024 14:08:59 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 14:08:18 05/02/2024 14:09:05 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 14:08:18 05/02/2024 14:09:11 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 14:08:18 05/02/2024 14:11:43 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 14:08:18 05/02/2024 14:11:50 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 14:08:18 05/02/2024 14:11:56 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 14:08:18 05/02/2024 14:12:02 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 14:08:18 05/02/2024 14:12:09 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 14:08:18 05/02/2024 14:12:15 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 14:08:18 05/02/2024 14:12:22 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 14:08:18 05/02/2024 14:12:28 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 14:01:09 05/02/2024 14:01:12 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 14:01:09 05/02/2024 14:01:18 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 14:01:09 05/02/2024 14:01:25 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 14:01:09 05/02/2024 14:01:31 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 14:01:09 05/02/2024 14:01:37 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 14:01:09 05/02/2024 14:01:44 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 14:01:09 05/02/2024 14:01:50 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 14:01:09 05/02/2024 14:01:57 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 14:01:09 05/02/2024 14:03:49 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 14:01:09 05/02/2024 14:03:55 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 14:01:09 05/02/2024 14:04:15 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 14:01:09 05/02/2024 14:04:21 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 14:01:09 05/02/2024 14:04:27 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 14:01:09 05/02/2024 14:04:34 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 14:01:09 05/02/2024 14:04:40 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 14:01:09 05/02/2024 14:04:47 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 13:59:59 05/02/2024 14:00:16 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 13:59:59 05/02/2024 14:00:31 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 13:59:58 05/02/2024 14:00:10 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 13:59:58 05/02/2024 14:00:25 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 13:57:43 05/02/2024 13:58:14 43731847 43731847 1,0 1113 Elevator Failure TTS communication stuck
KRM_SERVER 05/02/2024 13:57:43 05/02/2024 13:58:20 43731847 43731847 1,0 1113 Elevator Failure TTS communication stuck
KRM_SERVER 05/02/2024 13:57:39 05/02/2024 13:57:42 43731847 43731847 1,0 1044 Elevator Failure Drive not OK
KRM_SERVER 05/02/2024 13:57:39 05/02/2024 13:57:48 43731847 43731847 1,0 1044 Elevator Failure Drive not OK
KRM_SERVER 05/02/2024 13:57:39 05/02/2024 13:58:27 43731847 43731847 1,0 1044 Elevator Failure Drive not OK
KRM_SERVER 05/02/2024 13:57:39 05/02/2024 13:58:33 43731847 43731847 1,0 1044 Elevator Failure Drive not OK
KRM_SERVER 05/02/2024 13:54:53 05/02/2024 12:54:51 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 13:54:43 05/02/2024 12:55:04 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/02/2024 13:47:51 05/02/2024 13:47:55 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 13:47:51 05/02/2024 13:48:00 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 13:47:51 05/02/2024 13:48:07 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 13:47:51 05/02/2024 13:48:13 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 13:47:51 05/02/2024 13:48:20 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 13:47:51 05/02/2024 13:48:26 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 13:47:51 05/02/2024 13:48:33 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 13:47:51 05/02/2024 13:48:39 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 13:24:59 05/02/2024 13:25:45 43731847 43731847 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 05/02/2024 13:24:59 05/02/2024 13:25:52 43731847 43731847 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 05/02/2024 13:24:59 05/02/2024 13:25:58 43731847 43731847 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 05/02/2024 13:24:59 05/02/2024 13:26:05 43731847 43731847 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 05/02/2024 13:22:07 05/02/2024 13:24:42 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 13:22:07 05/02/2024 13:24:48 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 13:22:07 05/02/2024 13:24:54 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 13:22:07 05/02/2024 13:25:00 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 13:22:07 05/02/2024 13:25:07 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 13:22:07 05/02/2024 13:25:13 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 13:16:47 05/02/2024 13:16:56 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 13:16:47 05/02/2024 13:17:03 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 13:16:47 05/02/2024 13:17:09 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 13:16:47 05/02/2024 13:17:15 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 13:16:47 05/02/2024 13:17:22 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 13:16:47 05/02/2024 13:17:33 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 13:16:47 05/02/2024 13:18:56 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 13:16:47 05/02/2024 13:19:02 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 13:16:47 05/02/2024 13:19:09 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 13:16:47 05/02/2024 13:19:15 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 13:16:47 05/02/2024 13:19:22 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 13:16:47 05/02/2024 13:19:28 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 13:16:47 05/02/2024 13:19:35 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 13:16:47 05/02/2024 13:19:41 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 13:08:18 05/02/2024 13:08:26 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 13:08:18 05/02/2024 13:08:33 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 13:08:18 05/02/2024 13:08:39 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 13:08:18 05/02/2024 13:08:46 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 13:08:18 05/02/2024 13:08:52 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 13:08:18 05/02/2024 13:08:59 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 13:08:18 05/02/2024 13:09:05 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 13:08:18 05/02/2024 13:09:11 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 13:08:18 05/02/2024 13:11:43 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 13:08:18 05/02/2024 13:11:50 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 13:08:18 05/02/2024 13:11:56 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 13:08:18 05/02/2024 13:12:02 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 13:08:18 05/02/2024 13:12:09 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 13:08:18 05/02/2024 13:12:15 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 13:08:18 05/02/2024 13:12:22 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 13:08:18 05/02/2024 13:12:28 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 13:01:09 05/02/2024 13:01:12 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 13:01:09 05/02/2024 13:01:18 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 13:01:09 05/02/2024 13:01:25 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 13:01:09 05/02/2024 13:01:31 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 13:01:09 05/02/2024 13:01:37 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 13:01:09 05/02/2024 13:01:44 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 13:01:09 05/02/2024 13:01:50 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 13:01:09 05/02/2024 13:01:57 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 13:01:09 05/02/2024 13:03:49 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 13:01:09 05/02/2024 13:03:55 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 13:01:09 05/02/2024 13:04:15 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 13:01:09 05/02/2024 13:04:21 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 13:01:09 05/02/2024 13:04:27 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 13:01:09 05/02/2024 13:04:34 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 13:01:09 05/02/2024 13:04:40 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 13:01:09 05/02/2024 13:04:47 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 12:59:59 05/02/2024 13:00:16 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 12:59:59 05/02/2024 13:00:31 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 12:59:58 05/02/2024 13:00:10 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 12:59:58 05/02/2024 13:00:25 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 12:57:43 05/02/2024 12:58:14 43731847 43731847 1,0 1113 Elevator Failure TTS communication stuck
KRM_SERVER 05/02/2024 12:57:43 05/02/2024 12:58:20 43731847 43731847 1,0 1113 Elevator Failure TTS communication stuck
KRM_SERVER 05/02/2024 12:57:39 05/02/2024 12:57:42 43731847 43731847 1,0 1044 Elevator Failure Drive not OK
KRM_SERVER 05/02/2024 12:57:39 05/02/2024 12:57:48 43731847 43731847 1,0 1044 Elevator Failure Drive not OK
KRM_SERVER 05/02/2024 12:57:39 05/02/2024 12:58:27 43731847 43731847 1,0 1044 Elevator Failure Drive not OK
KRM_SERVER 05/02/2024 12:57:39 05/02/2024 12:58:33 43731847 43731847 1,0 1044 Elevator Failure Drive not OK
KRM_SERVER 05/02/2024 12:54:42 05/02/2024 12:55:38 43731847 43731847 1,0 1002 Elevator Failure Serial communication broken on board (TTS-1)
KRM_SERVER 05/02/2024 12:54:42 05/02/2024 12:55:44 43731847 43731847 1,0 1002 Elevator Failure Serial communication broken on board (TTS-1)
KRM_SERVER 05/02/2024 12:54:42 05/02/2024 12:57:55 43731847 43731847 1,0 1002 Elevator Failure Serial communication broken on board (TTS-1)
KRM_SERVER 05/02/2024 12:54:42 05/02/2024 12:58:01 43731847 43731847 1,0 1002 Elevator Failure Serial communication broken on board (TTS-1)
KRM_SERVER 05/02/2024 12:54:40 05/02/2024 12:55:31 43731847 43731847 1,0 1820 Elevator Failure Drive communication broken
KRM_SERVER 05/02/2024 12:54:40 05/02/2024 12:58:08 43731847 43731847 1,0 1820 Elevator Failure Drive communication broken
KRM_SERVER 05/02/2024 12:54:15 05/02/2024 12:54:27 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 12:54:15 05/02/2024 12:54:33 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 12:54:15 05/02/2024 12:54:39 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 12:54:15 05/02/2024 12:54:45 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 12:54:15 05/02/2024 12:54:57 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 12:54:15 05/02/2024 12:55:02 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 12:54:15 05/02/2024 12:55:12 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 12:54:15 05/02/2024 12:55:18 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 12:54:15 05/02/2024 12:58:46 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 12:54:15 05/02/2024 12:58:53 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 12:54:15 05/02/2024 12:58:59 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 12:54:15 05/02/2024 12:59:05 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 12:54:15 05/02/2024 12:59:12 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 12:54:15 05/02/2024 12:59:18 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 12:54:15 05/02/2024 12:59:25 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 12:54:15 05/02/2024 12:59:31 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 12:47:51 05/02/2024 12:47:55 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 12:47:51 05/02/2024 12:48:00 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 12:47:51 05/02/2024 12:48:07 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 12:47:51 05/02/2024 12:48:13 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 05/02/2024 12:47:51 05/02/2024 12:48:20 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/02/2024 12:47:51 05/02/2024 12:48:26 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/02/2024 12:47:51 05/02/2024 12:48:33 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/02/2024 12:47:51 05/02/2024 12:48:39 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 04/02/2024 14:44:52 04/02/2024 14:44:52 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 03/02/2024 14:44:59 03/02/2024 14:44:59 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 02/02/2024 14:46:33 02/02/2024 14:46:33 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 02/02/2024 14:44:55 02/02/2024 14:44:55 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 02/02/2024 13:06:41 02/02/2024 13:06:45 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 02/02/2024 13:06:41 02/02/2024 13:06:58 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 02/02/2024 13:06:41 02/02/2024 13:07:36 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 02/02/2024 13:06:41 02/02/2024 13:07:42 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 02/02/2024 12:06:41 02/02/2024 12:06:45 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 02/02/2024 12:06:41 02/02/2024 12:06:58 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 02/02/2024 12:06:41 02/02/2024 12:07:36 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 02/02/2024 12:06:41 02/02/2024 12:07:42 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 01/02/2024 14:44:56 01/02/2024 14:44:57 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 31/01/2024 14:45:00 31/01/2024 14:45:00 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 30/01/2024 14:45:01 30/01/2024 14:45:01 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 29/01/2024 14:45:01 29/01/2024 14:45:02 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 29/01/2024 10:14:04 29/01/2024 10:14:29 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 10:14:04 29/01/2024 10:16:28 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 10:14:03 29/01/2024 10:14:23 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 10:14:03 29/01/2024 10:16:22 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 10:10:25 29/01/2024 10:10:41 43731847 43731847 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/01/2024 10:10:25 29/01/2024 10:10:53 43731847 43731847 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/01/2024 10:10:24 29/01/2024 10:10:35 43731847 43731847 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/01/2024 10:10:24 29/01/2024 10:10:47 43731847 43731847 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/01/2024 09:47:54 29/01/2024 09:48:10 43731847 43731847 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/01/2024 09:47:54 29/01/2024 09:48:16 43731847 43731847 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/01/2024 09:47:54 29/01/2024 10:05:31 43731847 43731847 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/01/2024 09:47:54 29/01/2024 10:05:35 43731847 43731847 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/01/2024 09:36:48 29/01/2024 09:36:58 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 09:36:48 29/01/2024 09:37:04 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 09:36:48 29/01/2024 09:37:11 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 09:36:48 29/01/2024 09:37:17 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 09:36:48 29/01/2024 09:37:23 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 09:36:48 29/01/2024 09:37:30 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 09:36:48 29/01/2024 09:37:36 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 09:36:48 29/01/2024 09:37:43 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 09:36:48 29/01/2024 10:12:20 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 09:36:48 29/01/2024 10:12:26 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 09:36:48 29/01/2024 10:12:32 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 09:36:48 29/01/2024 10:12:45 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 09:36:48 29/01/2024 10:12:51 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 09:36:48 29/01/2024 10:12:58 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 09:36:48 29/01/2024 10:13:04 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 09:36:48 29/01/2024 10:13:11 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 09:30:31 29/01/2024 09:31:25 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 09:30:31 29/01/2024 09:31:31 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 09:30:31 29/01/2024 09:31:38 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 09:30:31 29/01/2024 09:31:44 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 09:30:30 29/01/2024 09:31:50 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 09:30:30 29/01/2024 09:31:57 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 09:30:30 29/01/2024 09:32:03 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 09:30:30 29/01/2024 09:32:10 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 09:29:39 29/01/2024 09:29:55 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 09:29:39 29/01/2024 09:30:01 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 09:29:39 29/01/2024 09:30:08 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 09:29:39 29/01/2024 09:30:14 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 09:29:39 29/01/2024 09:30:21 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 09:29:39 29/01/2024 09:30:27 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 09:29:39 29/01/2024 09:30:34 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 09:29:39 29/01/2024 09:30:40 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 09:29:39 29/01/2024 09:30:46 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 09:29:39 29/01/2024 09:30:53 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 09:29:39 29/01/2024 09:30:59 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 09:29:39 29/01/2024 09:31:06 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 09:29:39 29/01/2024 09:31:12 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 09:29:39 29/01/2024 09:31:18 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 09:29:39 29/01/2024 09:32:16 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 09:29:39 29/01/2024 09:32:22 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:59:54 29/01/2024 09:01:27 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:59:54 29/01/2024 09:02:00 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:59:54 29/01/2024 09:29:24 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:59:54 29/01/2024 09:29:29 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:59:54 29/01/2024 09:29:36 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:59:54 29/01/2024 09:29:42 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:59:54 29/01/2024 09:29:49 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:59:54 29/01/2024 09:32:35 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:59:54 29/01/2024 09:32:42 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:59:54 29/01/2024 09:32:48 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:59:09 29/01/2024 08:59:25 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:59:09 29/01/2024 08:59:31 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:59:09 29/01/2024 08:59:57 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:59:09 29/01/2024 09:00:04 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:59:09 29/01/2024 09:00:16 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:59:09 29/01/2024 09:00:49 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:38:56 29/01/2024 08:39:41 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:38:56 29/01/2024 08:39:48 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:38:56 29/01/2024 08:39:54 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:38:56 29/01/2024 08:40:33 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:38:56 29/01/2024 08:40:39 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:38:56 29/01/2024 08:40:45 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:38:55 29/01/2024 08:39:16 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:38:55 29/01/2024 08:39:22 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:38:55 29/01/2024 08:39:29 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:38:55 29/01/2024 08:40:07 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:38:55 29/01/2024 08:40:13 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:38:55 29/01/2024 08:40:20 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:38:16 29/01/2024 08:38:57 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:38:16 29/01/2024 08:39:03 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:38:16 29/01/2024 08:40:52 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:38:15 29/01/2024 08:41:18 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:38:15 29/01/2024 08:41:24 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:37:24 29/01/2024 08:38:05 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:37:24 29/01/2024 08:38:12 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:37:24 29/01/2024 08:38:18 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:37:24 29/01/2024 08:41:44 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:37:24 29/01/2024 08:41:50 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:37:23 29/01/2024 08:37:40 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:37:23 29/01/2024 08:37:46 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:37:23 29/01/2024 08:37:52 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:37:23 29/01/2024 08:38:31 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:37:23 29/01/2024 08:38:37 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:37:23 29/01/2024 08:38:44 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:32:46 29/01/2024 08:34:20 43731847 43731847 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/01/2024 08:32:46 29/01/2024 08:34:59 43731847 43731847 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/01/2024 08:32:45 29/01/2024 08:34:27 43731847 43731847 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/01/2024 08:32:45 29/01/2024 08:34:52 43731847 43731847 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/01/2024 08:32:33 29/01/2024 08:33:23 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:32:33 29/01/2024 08:33:29 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:32:33 29/01/2024 08:34:40 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:32:33 29/01/2024 08:34:46 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:32:14 29/01/2024 08:32:44 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:32:14 29/01/2024 08:33:04 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:32:14 29/01/2024 08:35:05 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:32:14 29/01/2024 08:35:12 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:32:04 29/01/2024 08:32:25 43731847 43731847 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/01/2024 08:32:04 29/01/2024 08:32:32 43731847 43731847 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 29/01/2024 08:32:04 29/01/2024 08:33:10 43731847 43731847 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/01/2024 08:32:04 29/01/2024 08:33:16 43731847 43731847 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 29/01/2024 08:32:02 29/01/2024 08:32:13 43731847 43731847 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 29/01/2024 08:32:02 29/01/2024 08:32:51 43731847 43731847 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/01/2024 08:32:02 29/01/2024 08:32:57 43731847 43731847 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 29/01/2024 08:29:14 29/01/2024 08:29:57 43731847 43731847 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 29/01/2024 08:29:14 29/01/2024 08:30:10 43731847 43731847 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 29/01/2024 08:29:13 29/01/2024 08:29:51 43731847 43731847 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 29/01/2024 08:29:13 29/01/2024 08:30:04 43731847 43731847 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 29/01/2024 08:28:41 29/01/2024 08:29:12 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:28:41 29/01/2024 08:29:32 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:28:41 29/01/2024 08:32:19 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:28:41 29/01/2024 08:32:38 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:28:37 29/01/2024 08:28:53 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:28:37 29/01/2024 08:29:00 43731847 43731847 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 29/01/2024 08:28:37 29/01/2024 08:29:45 43731847 43731847 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 29/01/2024 08:28:37 29/01/2024 08:35:18 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:28:36 29/01/2024 08:28:47 43731847 43731847 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 29/01/2024 08:28:36 29/01/2024 08:29:25 43731847 43731847 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 29/01/2024 08:28:25 29/01/2024 08:28:40 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:28:25 29/01/2024 08:29:06 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:28:24 29/01/2024 08:28:35 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:26:30 29/01/2024 08:26:46 43731847 43731847 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/01/2024 08:26:30 29/01/2024 08:29:38 43731847 43731847 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/01/2024 08:26:29 29/01/2024 08:26:40 43731847 43731847 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/01/2024 08:26:29 29/01/2024 08:29:19 43731847 43731847 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/01/2024 08:23:23 29/01/2024 08:24:14 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:23:23 29/01/2024 08:24:20 43731847 43731847 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 29/01/2024 08:23:23 29/01/2024 08:24:53 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:23:22 29/01/2024 08:24:27 43731847 43731847 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 29/01/2024 08:23:22 29/01/2024 08:24:33 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:22:39 29/01/2024 08:23:10 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:22:39 29/01/2024 08:23:23 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:22:39 29/01/2024 08:24:40 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:22:39 29/01/2024 08:24:59 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:22:29 29/01/2024 08:22:44 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:22:29 29/01/2024 08:22:51 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:22:29 29/01/2024 08:24:01 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:22:29 29/01/2024 08:24:46 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 29/01/2024 08:21:33 29/01/2024 08:22:19 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:21:33 29/01/2024 08:22:25 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:21:33 29/01/2024 08:22:31 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:21:33 29/01/2024 08:22:38 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:21:33 29/01/2024 08:23:49 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:21:33 29/01/2024 08:23:55 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:21:33 29/01/2024 08:24:08 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 29/01/2024 08:21:33 29/01/2024 08:25:05 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 29/01/2024 08:21:22 29/01/2024 08:21:53 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:21:22 29/01/2024 08:21:59 43731847 43731847 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 29/01/2024 08:21:22 29/01/2024 08:23:29 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:21:22 29/01/2024 08:25:27 43731847 43731847 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 29/01/2024 08:21:21 29/01/2024 08:21:34 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:21:21 29/01/2024 08:21:40 43731847 43731847 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 29/01/2024 08:21:21 29/01/2024 08:23:16 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:21:21 29/01/2024 08:25:33 43731847 43731847 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 29/01/2024 08:21:11 29/01/2024 08:21:22 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:21:11 29/01/2024 08:21:27 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:21:11 29/01/2024 08:21:47 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:21:11 29/01/2024 08:22:06 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 29/01/2024 08:20:39 29/01/2024 08:21:00 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 29/01/2024 08:20:39 29/01/2024 08:21:13 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 29/01/2024 08:20:38 29/01/2024 08:20:53 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 29/01/2024 08:20:38 29/01/2024 08:21:06 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 29/01/2024 08:19:55 29/01/2024 08:20:06 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 29/01/2024 08:19:55 29/01/2024 08:20:12 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 29/01/2024 08:19:55 29/01/2024 08:20:18 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 29/01/2024 08:19:55 29/01/2024 08:20:24 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 28/01/2024 14:45:02 28/01/2024 14:45:02 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 27/01/2024 14:45:05 27/01/2024 14:45:05 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 26/01/2024 14:45:10 26/01/2024 14:45:10 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 25/01/2024 14:45:04 25/01/2024 14:45:05 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 24/01/2024 14:45:07 24/01/2024 14:45:07 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 23/01/2024 15:24:51 23/01/2024 14:24:57 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 23/01/2024 15:24:44 23/01/2024 14:24:50 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 23/01/2024 15:21:59 23/01/2024 14:22:06 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 23/01/2024 15:21:53 23/01/2024 14:21:58 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 23/01/2024 15:07:48 23/01/2024 14:07:53 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 23/01/2024 15:07:40 23/01/2024 14:07:46 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 23/01/2024 15:02:15 23/01/2024 14:02:21 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 23/01/2024 15:02:05 23/01/2024 14:02:11 43731847 43731847 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 23/01/2024 14:45:09 23/01/2024 14:45:09 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 23/01/2024 14:44:39 23/01/2024 14:44:39 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 23/01/2024 14:40:02 23/01/2024 14:40:12 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 23/01/2024 14:40:02 23/01/2024 14:40:18 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 23/01/2024 14:40:02 23/01/2024 14:40:24 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 23/01/2024 14:40:02 23/01/2024 14:40:40 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 23/01/2024 14:40:02 23/01/2024 14:40:46 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 23/01/2024 14:40:02 23/01/2024 14:40:52 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 23/01/2024 14:40:02 23/01/2024 14:41:25 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 23/01/2024 14:40:02 23/01/2024 14:41:32 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 23/01/2024 14:40:02 23/01/2024 14:41:38 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 23/01/2024 14:40:02 23/01/2024 14:41:45 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 23/01/2024 14:40:02 23/01/2024 14:41:51 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 23/01/2024 14:40:02 23/01/2024 14:42:30 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 23/01/2024 14:35:19 23/01/2024 14:35:23 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 14:35:19 23/01/2024 14:35:28 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 14:35:19 23/01/2024 14:39:43 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 14:35:19 23/01/2024 14:39:49 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 14:26:21 23/01/2024 14:26:26 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 23/01/2024 14:26:21 23/01/2024 14:26:32 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 23/01/2024 14:26:21 23/01/2024 14:26:38 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 23/01/2024 14:26:21 23/01/2024 14:26:45 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 23/01/2024 14:26:21 23/01/2024 14:26:51 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 23/01/2024 14:26:21 23/01/2024 14:26:58 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 23/01/2024 14:26:21 23/01/2024 14:27:37 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 23/01/2024 14:26:21 23/01/2024 14:27:43 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 23/01/2024 14:26:21 23/01/2024 14:27:50 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 23/01/2024 14:26:21 23/01/2024 14:28:03 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 23/01/2024 14:26:21 23/01/2024 14:28:09 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 23/01/2024 14:26:21 23/01/2024 14:28:16 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 23/01/2024 14:26:00 23/01/2024 14:26:13 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 14:26:00 23/01/2024 14:26:19 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 14:26:00 23/01/2024 14:27:30 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 14:26:00 23/01/2024 14:27:56 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 14:25:44 23/01/2024 14:25:48 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 23/01/2024 14:25:44 23/01/2024 14:25:53 43731847 43731847 1,0 1012 Elevator Failure Rear car door contact opened during drive (C6)
KRM_SERVER 23/01/2024 14:25:44 23/01/2024 14:26:00 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 23/01/2024 14:25:44 23/01/2024 14:26:06 43731847 43731847 1,0 1012 Elevator Failure Rear car door contact opened during drive (C6)
KRM_SERVER 23/01/2024 14:25:44 23/01/2024 14:27:05 43731847 43731847 1,0 1012 Elevator Failure Rear car door contact opened during drive (C6)
KRM_SERVER 23/01/2024 14:25:44 23/01/2024 14:27:11 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 23/01/2024 14:25:44 23/01/2024 14:27:17 43731847 43731847 1,0 1012 Elevator Failure Rear car door contact opened during drive (C6)
KRM_SERVER 23/01/2024 14:25:44 23/01/2024 14:27:24 43731847 43731847 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 23/01/2024 14:18:37 23/01/2024 14:18:41 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 14:18:37 23/01/2024 14:18:47 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 23/01/2024 14:18:37 23/01/2024 14:18:54 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 23/01/2024 14:18:37 23/01/2024 14:19:00 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 23/01/2024 14:18:37 23/01/2024 14:19:07 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 14:18:37 23/01/2024 14:19:13 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 23/01/2024 14:18:37 23/01/2024 14:19:19 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 23/01/2024 14:18:37 23/01/2024 14:19:26 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 23/01/2024 14:18:37 23/01/2024 14:19:32 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 23/01/2024 14:18:37 23/01/2024 14:19:39 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 23/01/2024 14:18:37 23/01/2024 14:19:45 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 14:18:37 23/01/2024 14:19:51 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 23/01/2024 14:18:37 23/01/2024 14:19:58 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 23/01/2024 14:18:37 23/01/2024 14:20:07 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 23/01/2024 14:18:37 23/01/2024 14:20:14 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 13:59:06 23/01/2024 13:59:15 43731847 43731847 1,0 1106 Elevator Failure Setup failed
KRM_SERVER 23/01/2024 13:59:06 23/01/2024 13:59:28 43731847 43731847 1,0 1106 Elevator Failure Setup failed
KRM_SERVER 23/01/2024 13:59:06 23/01/2024 13:59:48 43731847 43731847 1,0 1106 Elevator Failure Setup failed
KRM_SERVER 23/01/2024 13:59:06 23/01/2024 13:59:54 43731847 43731847 1,0 1106 Elevator Failure Setup failed
KRM_SERVER 23/01/2024 13:55:24 23/01/2024 13:55:27 43731847 43731847 1,0 1106 Elevator Failure Setup failed
KRM_SERVER 23/01/2024 13:55:24 23/01/2024 13:55:33 43731847 43731847 1,0 1106 Elevator Failure Setup failed
KRM_SERVER 23/01/2024 13:48:59 23/01/2024 13:49:24 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 23/01/2024 13:48:59 23/01/2024 13:49:30 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 23/01/2024 13:48:59 23/01/2024 13:49:36 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 23/01/2024 13:48:59 23/01/2024 13:49:43 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 23/01/2024 13:48:59 23/01/2024 13:49:49 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 23/01/2024 13:48:59 23/01/2024 13:49:56 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 23/01/2024 13:48:59 23/01/2024 13:50:02 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 13:48:59 23/01/2024 13:52:38 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 23/01/2024 13:48:59 23/01/2024 13:52:44 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 23/01/2024 13:48:59 23/01/2024 13:52:51 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 23/01/2024 13:48:59 23/01/2024 13:52:57 43731847 43731847 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 23/01/2024 13:48:59 23/01/2024 13:53:04 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 13:48:59 23/01/2024 13:53:16 43731847 43731847 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 23/01/2024 13:48:59 23/01/2024 13:53:23 43731847 43731847 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 23/01/2024 13:48:58 23/01/2024 13:50:08 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 13:48:58 23/01/2024 13:53:10 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 13:48:10 23/01/2024 13:48:58 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 13:48:10 23/01/2024 13:49:04 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 13:48:10 23/01/2024 13:49:11 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 13:48:10 23/01/2024 13:50:15 43731847 43731847 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 23/01/2024 13:47:38 23/01/2024 13:48:06 43731847 43731847 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 23/01/2024 13:47:38 23/01/2024 13:48:13 43731847 43731847 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 23/01/2024 13:47:38 23/01/2024 13:48:19 43731847 43731847 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 23/01/2024 13:47:38 23/01/2024 13:48:26 43731847 43731847 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 23/01/2024 13:47:38 23/01/2024 13:48:32 43731847 43731847 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 23/01/2024 13:47:38 23/01/2024 13:48:39 43731847 43731847 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 23/01/2024 13:47:38 23/01/2024 13:48:45 43731847 43731847 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 23/01/2024 13:47:38 23/01/2024 13:48:51 43731847 43731847 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 23/01/2024 13:47:13 23/01/2024 13:47:34 43731847 43731847 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 23/01/2024 13:47:13 23/01/2024 13:48:00 43731847 43731847 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 23/01/2024 13:47:12 23/01/2024 13:47:16 43731847 43731847 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 23/01/2024 13:47:12 23/01/2024 13:47:21 43731847 43731847 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 23/01/2024 13:47:12 23/01/2024 13:47:28 43731847 43731847 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 23/01/2024 13:47:12 23/01/2024 13:47:41 43731847 43731847 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 23/01/2024 13:47:12 23/01/2024 13:47:47 43731847 43731847 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 23/01/2024 13:47:12 23/01/2024 13:47:54 43731847 43731847 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 23/01/2024 13:40:31 23/01/2024 13:41:01 43731847 43731847 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 23/01/2024 13:40:31 23/01/2024 13:41:07 43731847 43731847 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 23/01/2024 13:40:31 23/01/2024 13:41:14 43731847 43731847 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 23/01/2024 13:40:30 23/01/2024 13:41:20 43731847 43731847 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 23/01/2024 13:39:49 23/01/2024 13:40:54 43731847 43731847 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 23/01/2024 13:39:49 23/01/2024 13:41:33 43731847 43731847 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 23/01/2024 13:39:48 23/01/2024 13:40:48 43731847 43731847 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 23/01/2024 13:39:48 23/01/2024 13:41:39 43731847 43731847 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 23/01/2024 13:39:40 23/01/2024 13:39:44 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 23/01/2024 13:39:40 23/01/2024 13:39:50 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 23/01/2024 13:39:40 23/01/2024 13:40:02 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 23/01/2024 13:39:40 23/01/2024 13:40:09 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 23/01/2024 13:14:58 23/01/2024 13:15:07 43731847 43731847 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/01/2024 13:14:58 23/01/2024 13:31:54 43731847 43731847 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/01/2024 13:14:57 23/01/2024 13:15:00 43731847 43731847 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/01/2024 13:14:57 23/01/2024 13:31:48 43731847 43731847 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 22/01/2024 14:46:19 22/01/2024 14:46:19 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 22/01/2024 14:44:46 22/01/2024 14:44:46 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 21/01/2024 14:44:43 21/01/2024 14:44:43 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 20/01/2024 14:44:46 20/01/2024 14:44:46 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 19/01/2024 14:44:46 19/01/2024 14:44:46 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 18/01/2024 14:44:48 18/01/2024 14:44:48 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 17/01/2024 14:44:49 17/01/2024 14:44:49 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 16/01/2024 14:44:50 16/01/2024 14:44:50 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 15/01/2024 14:44:56 15/01/2024 14:44:57 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 14/01/2024 14:44:53 14/01/2024 14:44:53 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 13/01/2024 14:44:56 13/01/2024 14:44:56 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 12/01/2024 14:44:55 12/01/2024 14:44:56 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 11/01/2024 14:44:59 11/01/2024 14:44:59 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 10/01/2024 14:44:59 10/01/2024 14:44:59 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 09/01/2024 14:45:01 09/01/2024 14:45:01 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 08/01/2024 17:21:57 08/01/2024 17:22:02 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 08/01/2024 17:21:57 08/01/2024 17:22:07 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 08/01/2024 17:21:57 08/01/2024 17:22:14 43731847 43731847 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 08/01/2024 17:21:57 08/01/2024 17:22:20 43731847 43731847 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 08/01/2024 17:21:42 08/01/2024 17:21:45 43731847 43731847 1,0 1830 Elevator Failure LON communication error
KRM_SERVER 08/01/2024 17:21:42 08/01/2024 17:22:27 43731847 43731847 1,0 1830 Elevator Failure LON communication error
KRM_SERVER 08/01/2024 14:45:02 08/01/2024 14:45:02 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 07/01/2024 14:45:04 07/01/2024 14:45:04 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 06/01/2024 14:45:05 06/01/2024 14:45:05 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 05/01/2024 15:55:27 05/01/2024 15:55:31 43731847 43731847 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 05/01/2024 15:55:27 05/01/2024 15:55:43 43731847 43731847 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 05/01/2024 15:55:27 06/01/2024 16:05:56 43731847 43731847 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 05/01/2024 15:55:27 06/01/2024 16:06:09 43731847 43731847 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 05/01/2024 14:53:39 05/01/2024 14:53:48 43731847 43731847 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 05/01/2024 14:53:39 05/01/2024 14:53:54 43731847 43731847 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 05/01/2024 14:53:39 05/01/2024 14:54:01 43731847 43731847 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 05/01/2024 14:53:39 05/01/2024 14:54:07 43731847 43731847 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 05/01/2024 14:53:39 05/01/2024 14:54:20 43731847 43731847 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 05/01/2024 14:53:39 05/01/2024 14:54:26 43731847 43731847 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 05/01/2024 14:53:39 05/01/2024 14:54:39 43731847 43731847 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 05/01/2024 14:53:39 06/01/2024 16:06:03 43731847 43731847 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 05/01/2024 14:53:38 05/01/2024 14:53:42 43731847 43731847 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 05/01/2024 14:53:38 05/01/2024 14:54:33 43731847 43731847 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 05/01/2024 14:48:42 05/01/2024 14:49:51 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 05/01/2024 14:48:29 05/01/2024 14:50:12 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 05/01/2024 14:48:29 05/01/2024 15:55:36 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 05/01/2024 14:48:23 05/01/2024 14:50:18 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 05/01/2024 14:48:22 05/01/2024 14:50:25 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 05/01/2024 14:48:21 05/01/2024 14:49:38 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 05/01/2024 14:48:21 05/01/2024 14:50:38 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 05/01/2024 14:48:09 05/01/2024 14:49:31 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 05/01/2024 14:48:08 05/01/2024 14:49:18 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 05/01/2024 14:48:08 05/01/2024 14:49:44 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 05/01/2024 14:48:07 05/01/2024 14:48:59 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 05/01/2024 14:48:07 05/01/2024 14:49:25 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 05/01/2024 14:48:06 05/01/2024 14:48:40 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 05/01/2024 14:48:06 05/01/2024 14:48:46 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 05/01/2024 14:48:06 05/01/2024 14:49:06 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 05/01/2024 14:48:06 05/01/2024 14:49:12 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 05/01/2024 14:48:05 05/01/2024 14:48:27 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 05/01/2024 14:48:05 05/01/2024 14:48:33 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 05/01/2024 14:48:00 05/01/2024 14:48:08 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 05/01/2024 14:48:00 05/01/2024 14:48:53 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 05/01/2024 14:47:45 05/01/2024 14:47:49 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 05/01/2024 14:47:45 05/01/2024 14:48:01 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 05/01/2024 14:47:45 05/01/2024 14:48:20 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 05/01/2024 14:47:45 05/01/2024 14:54:13 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 05/01/2024 14:45:06 05/01/2024 14:45:07 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 05/01/2024 14:44:30 05/01/2024 14:44:38 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 05/01/2024 14:44:30 05/01/2024 14:47:55 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 05/01/2024 14:44:29 05/01/2024 14:44:33 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 05/01/2024 14:44:29 05/01/2024 14:48:14 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 20:19:20 04/01/2024 20:19:28 43731847 43731847 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 04/01/2024 20:19:20 05/01/2024 14:27:12 43731847 43731847 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 04/01/2024 20:19:19 04/01/2024 20:19:23 43731847 43731847 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 04/01/2024 20:19:19 05/01/2024 14:27:24 43731847 43731847 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 04/01/2024 15:48:42 04/01/2024 15:48:42 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 04/01/2024 12:14:48 04/01/2024 12:22:09 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 12:14:48 04/01/2024 20:19:35 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 12:14:32 04/01/2024 12:22:16 43731847 43731847 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 04/01/2024 12:14:32 04/01/2024 12:22:22 43731847 43731847 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 04/01/2024 12:14:32 04/01/2024 12:22:28 43731847 43731847 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 04/01/2024 12:14:32 04/01/2024 12:22:35 43731847 43731847 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 04/01/2024 12:14:32 04/01/2024 12:22:41 43731847 43731847 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 04/01/2024 12:14:32 05/01/2024 14:27:18 43731847 43731847 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 04/01/2024 12:14:31 04/01/2024 12:22:48 43731847 43731847 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 04/01/2024 12:14:31 04/01/2024 12:22:54 43731847 43731847 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 04/01/2024 12:14:31 04/01/2024 12:23:00 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 12:14:31 04/01/2024 12:23:07 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 12:13:22 04/01/2024 12:28:54 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 12:13:21 04/01/2024 12:29:00 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 12:13:18 04/01/2024 12:29:13 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 12:13:14 04/01/2024 12:29:26 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:59:15 04/01/2024 12:46:31 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 11:59:15 04/01/2024 12:46:38 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 11:39:43 04/01/2024 11:39:48 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:38:55 04/01/2024 11:39:02 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:38:55 04/01/2024 11:39:09 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:38:55 04/01/2024 11:39:54 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:38:54 04/01/2024 11:39:15 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 11:37:24 04/01/2024 11:37:27 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:37:24 04/01/2024 11:39:28 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:33:50 04/01/2024 11:34:10 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:33:50 04/01/2024 11:39:35 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:33:49 04/01/2024 11:34:04 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:33:49 04/01/2024 11:37:33 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:28:44 04/01/2024 11:28:58 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:28:44 04/01/2024 11:29:05 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:28:44 04/01/2024 11:33:57 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:28:44 04/01/2024 11:34:23 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:23:39 04/01/2024 11:23:42 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:23:39 04/01/2024 11:28:52 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:23:39 04/01/2024 11:29:18 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:18:33 04/01/2024 11:18:41 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 11:18:33 04/01/2024 11:24:07 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:18:33 04/01/2024 11:39:41 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 11:13:28 04/01/2024 11:19:20 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 11:08:22 04/01/2024 11:08:30 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 11:08:22 04/01/2024 11:09:15 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 11:03:16 04/01/2024 11:03:19 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 11:03:16 04/01/2024 11:04:03 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 10:58:11 04/01/2024 10:58:19 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 10:58:11 04/01/2024 10:59:18 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 10:53:06 04/01/2024 10:53:14 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:53:06 04/01/2024 10:53:21 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 10:53:06 04/01/2024 10:54:12 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 10:48:02 04/01/2024 10:48:54 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:48:01 04/01/2024 10:48:21 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 10:48:01 04/01/2024 10:48:34 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 10:48:01 04/01/2024 10:48:41 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:48:01 04/01/2024 10:49:00 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 10:48:01 04/01/2024 10:53:40 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:48:01 04/01/2024 11:18:48 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 10:48:00 04/01/2024 10:48:03 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:48:00 04/01/2024 10:48:09 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:48:00 04/01/2024 10:48:28 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:48:00 04/01/2024 10:48:47 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:32:44 04/01/2024 10:32:47 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:32:44 04/01/2024 10:32:53 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:32:44 04/01/2024 10:48:15 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:32:44 04/01/2024 10:49:06 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:27:39 04/01/2024 10:27:54 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:27:39 04/01/2024 10:33:00 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:27:38 04/01/2024 10:27:41 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:27:38 04/01/2024 10:27:47 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:22:33 04/01/2024 10:22:36 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:22:33 04/01/2024 10:28:06 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:12:23 04/01/2024 10:28:00 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 10:12:22 04/01/2024 10:17:31 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:36:45 04/01/2024 09:37:05 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:36:44 04/01/2024 09:36:58 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:31:38 04/01/2024 09:31:53 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:31:38 04/01/2024 09:31:59 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:31:38 04/01/2024 09:36:46 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:31:38 04/01/2024 09:36:52 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:26:33 04/01/2024 09:26:54 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:26:33 04/01/2024 09:31:46 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:26:32 04/01/2024 09:26:47 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:26:32 04/01/2024 09:31:41 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:21:27 04/01/2024 09:21:41 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:21:27 04/01/2024 09:21:47 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:21:27 04/01/2024 09:26:35 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:21:27 04/01/2024 09:26:41 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:16:21 04/01/2024 09:16:35 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:16:21 04/01/2024 09:16:41 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:16:21 04/01/2024 09:21:29 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:16:21 04/01/2024 09:21:34 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:11:19 04/01/2024 09:12:06 43731847 43731847 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/01/2024 09:11:19 04/01/2024 09:13:22 43731847 43731847 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/01/2024 09:11:14 04/01/2024 09:16:22 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 09:11:14 04/01/2024 09:16:28 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:55:48 04/01/2024 08:56:42 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:55:48 04/01/2024 08:57:08 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:50:41 04/01/2024 08:51:03 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:50:41 04/01/2024 08:55:51 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:43:13 04/01/2024 08:44:02 43731847 43731847 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/01/2024 08:43:13 04/01/2024 08:44:09 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:43:13 04/01/2024 08:44:41 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:43:13 04/01/2024 08:45:16 43731847 43731847 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/01/2024 08:43:12 04/01/2024 08:43:41 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:43:12 04/01/2024 08:48:23 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:38:05 04/01/2024 08:38:46 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:38:05 04/01/2024 08:39:27 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:38:04 04/01/2024 08:38:34 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:38:04 04/01/2024 08:43:10 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:32:57 04/01/2024 08:33:20 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:32:57 04/01/2024 08:33:33 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:32:57 04/01/2024 08:34:11 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:32:57 04/01/2024 08:38:08 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:27:46 04/01/2024 08:27:59 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:22:39 04/01/2024 08:22:51 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:22:39 04/01/2024 08:22:58 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:22:39 04/01/2024 08:27:47 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:17:35 04/01/2024 08:18:03 43731847 43731847 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/01/2024 08:17:35 04/01/2024 08:19:39 43731847 43731847 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/01/2024 08:17:31 04/01/2024 08:17:50 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:17:31 04/01/2024 08:17:57 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:17:31 04/01/2024 08:22:39 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:17:31 04/01/2024 08:22:45 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:12:29 04/01/2024 08:13:34 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:12:29 04/01/2024 08:13:40 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:12:29 04/01/2024 08:17:32 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:12:29 04/01/2024 08:17:44 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:12:26 04/01/2024 08:12:55 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:12:26 04/01/2024 08:13:01 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:12:26 04/01/2024 08:13:08 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:12:26 04/01/2024 08:13:21 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:12:26 04/01/2024 08:13:47 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:12:26 04/01/2024 08:17:37 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 08:12:23 04/01/2024 08:12:42 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:12:23 04/01/2024 08:12:49 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:12:23 04/01/2024 08:13:14 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:12:23 04/01/2024 08:13:27 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:07:21 04/01/2024 08:12:24 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 08:07:21 04/01/2024 08:12:36 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:49:26 04/01/2024 07:50:33 43731847 43731847 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/01/2024 07:49:26 04/01/2024 07:51:30 43731847 43731847 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/01/2024 07:49:23 04/01/2024 07:49:55 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:49:23 04/01/2024 07:50:53 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:44:16 04/01/2024 07:44:47 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:44:16 04/01/2024 07:45:38 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:39:10 04/01/2024 07:39:57 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:39:10 04/01/2024 07:40:29 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:34:04 04/01/2024 07:34:32 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:34:04 04/01/2024 07:39:12 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:28:56 04/01/2024 07:29:17 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:28:56 04/01/2024 07:34:05 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:21:27 04/01/2024 07:21:55 43731847 43731847 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/01/2024 07:21:27 04/01/2024 07:22:01 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:21:27 04/01/2024 07:23:30 43731847 43731847 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/01/2024 07:21:27 04/01/2024 07:26:37 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:21:23 04/01/2024 07:21:42 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:16:21 04/01/2024 07:17:32 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:16:21 04/01/2024 07:21:23 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:16:20 04/01/2024 07:17:06 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:16:20 04/01/2024 07:17:38 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:16:18 04/01/2024 07:16:47 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:16:18 04/01/2024 07:16:53 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:16:18 04/01/2024 07:21:29 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:16:15 04/01/2024 07:16:34 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:16:15 04/01/2024 07:16:40 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:16:15 04/01/2024 07:17:00 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:16:15 04/01/2024 07:17:12 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:11:13 04/01/2024 07:12:17 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:11:13 04/01/2024 07:12:24 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:11:13 04/01/2024 07:16:15 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:11:13 04/01/2024 07:16:28 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:11:10 04/01/2024 07:11:39 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:11:10 04/01/2024 07:11:45 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:11:10 04/01/2024 07:11:52 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:11:10 04/01/2024 07:12:11 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:11:10 04/01/2024 07:12:30 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:11:10 04/01/2024 07:16:21 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 07:11:07 04/01/2024 07:11:26 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:11:07 04/01/2024 07:11:32 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:11:07 04/01/2024 07:11:58 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:11:07 04/01/2024 07:12:05 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:06:05 04/01/2024 07:11:07 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 07:06:04 04/01/2024 07:11:20 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:53:27 04/01/2024 06:54:33 43731847 43731847 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/01/2024 06:53:27 04/01/2024 06:55:30 43731847 43731847 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/01/2024 06:32:52 04/01/2024 06:33:17 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:32:52 04/01/2024 06:33:30 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:32:52 04/01/2024 06:34:09 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:32:52 04/01/2024 06:38:05 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:25:27 04/01/2024 06:26:34 43731847 43731847 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/01/2024 06:25:27 04/01/2024 06:27:30 43731847 43731847 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/01/2024 06:25:24 04/01/2024 06:25:55 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:25:24 04/01/2024 06:26:01 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:25:24 04/01/2024 06:26:53 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:25:24 04/01/2024 06:30:49 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:20:16 04/01/2024 06:20:47 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:20:16 04/01/2024 06:20:53 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:20:16 04/01/2024 06:21:38 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:20:16 04/01/2024 06:25:29 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:20:15 04/01/2024 06:20:34 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:20:15 04/01/2024 06:21:13 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:15:13 04/01/2024 06:16:31 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:15:13 04/01/2024 06:20:16 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:15:09 04/01/2024 06:15:39 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:15:09 04/01/2024 06:15:46 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:15:09 04/01/2024 06:15:54 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:15:09 04/01/2024 06:16:11 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:15:09 04/01/2024 06:16:24 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:15:09 04/01/2024 06:20:21 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:15:08 04/01/2024 06:15:33 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:15:08 04/01/2024 06:16:05 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:15:07 04/01/2024 06:15:27 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:15:07 04/01/2024 06:15:59 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:10:05 04/01/2024 06:11:10 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:10:05 04/01/2024 06:11:17 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:10:05 04/01/2024 06:15:08 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:10:05 04/01/2024 06:15:20 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:10:01 04/01/2024 06:10:32 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:10:01 04/01/2024 06:10:38 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:10:01 04/01/2024 06:10:45 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:10:01 04/01/2024 06:11:04 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:10:01 04/01/2024 06:11:23 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:10:01 04/01/2024 06:15:14 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 06:10:00 04/01/2024 06:10:19 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:10:00 04/01/2024 06:10:25 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:10:00 04/01/2024 06:10:51 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 06:10:00 04/01/2024 06:10:57 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:57:28 04/01/2024 05:58:35 43731847 43731847 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/01/2024 05:57:28 04/01/2024 05:59:30 43731847 43731847 1,0 1703 Elevator Failure Start failed
KRM_SERVER 04/01/2024 05:51:55 04/01/2024 05:52:49 43731847 43731847 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 04/01/2024 05:51:55 04/01/2024 05:57:37 43731847 43731847 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 04/01/2024 05:46:22 04/01/2024 05:47:29 43731847 43731847 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 04/01/2024 05:46:22 04/01/2024 05:52:04 43731847 43731847 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 04/01/2024 05:40:50 04/01/2024 05:41:43 43731847 43731847 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 04/01/2024 05:40:50 04/01/2024 05:46:31 43731847 43731847 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 04/01/2024 05:35:17 04/01/2024 05:36:10 43731847 43731847 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 04/01/2024 05:35:17 04/01/2024 05:40:59 43731847 43731847 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 04/01/2024 05:30:05 04/01/2024 05:30:30 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:30:05 04/01/2024 05:30:43 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:30:05 04/01/2024 05:31:15 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:30:05 04/01/2024 05:35:19 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:24:58 04/01/2024 05:25:35 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:24:58 04/01/2024 05:30:11 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:24:57 04/01/2024 05:25:22 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:24:57 04/01/2024 05:26:07 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:19:49 04/01/2024 05:20:08 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:19:49 04/01/2024 05:20:21 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:19:49 04/01/2024 05:20:27 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:19:49 04/01/2024 05:20:40 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:19:49 04/01/2024 05:20:59 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:19:49 04/01/2024 05:25:03 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:14:45 04/01/2024 05:15:39 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:14:45 04/01/2024 05:15:45 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:14:45 04/01/2024 05:19:49 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:14:45 04/01/2024 05:20:02 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:14:42 04/01/2024 05:15:20 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:14:42 04/01/2024 05:19:55 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:14:41 04/01/2024 05:15:00 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:14:41 04/01/2024 05:15:07 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:14:41 04/01/2024 05:15:13 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:14:41 04/01/2024 05:15:26 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:14:41 04/01/2024 05:15:33 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:14:41 04/01/2024 05:15:52 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:09:37 04/01/2024 05:10:38 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:09:37 04/01/2024 05:14:42 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:09:36 04/01/2024 05:10:32 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:09:36 04/01/2024 05:14:54 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:09:35 04/01/2024 05:09:53 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:09:35 04/01/2024 05:09:59 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:09:35 04/01/2024 05:10:06 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:09:35 04/01/2024 05:10:25 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:09:35 04/01/2024 05:10:44 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:09:35 04/01/2024 05:14:48 43731847 43731847 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 04/01/2024 05:09:34 04/01/2024 05:09:46 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:09:34 04/01/2024 05:10:19 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:09:33 04/01/2024 05:09:40 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 04/01/2024 05:09:33 04/01/2024 05:10:12 43731847 43731847 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 03/01/2024 15:48:42 03/01/2024 15:48:42 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 02/01/2024 15:48:44 02/01/2024 15:48:44 43731847 43731847 1,0 Réception Appel Cyclique
KRM_SERVER 02/01/2024 14:58:25 02/01/2024 14:58:25 43731847 43731847 1,0 Réception Appel Cyclique