Suivi Activite Telesurveillance 44139966


Liste des evenements recus sur les 3 derniers mois.

3697 evenements trouves.

Date evenement/envoi Date Reception N°Trs N° Equipement voie Code alarme Type alarme
KRM_SERVER 09/03/2026 06:27:24 09/03/2026 06:27:29 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/03/2026 06:27:26 08/03/2026 06:27:31 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/03/2026 06:27:27 07/03/2026 06:36:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/03/2026 06:27:29 06/03/2026 06:27:34 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/03/2026 06:27:31 05/03/2026 06:27:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/03/2026 06:27:01 05/03/2026 06:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/03/2026 17:57:02 04/03/2026 15:56:26 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 04/03/2026 17:55:46 04/03/2026 15:55:11 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 04/03/2026 16:56:55 04/03/2026 15:56:46 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 04/03/2026 16:56:55 04/03/2026 15:56:52 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 04/03/2026 16:56:55 04/03/2026 15:57:04 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 04/03/2026 16:56:55 04/03/2026 15:57:10 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 04/03/2026 16:56:55 04/03/2026 15:57:15 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 04/03/2026 16:56:55 04/03/2026 15:57:22 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 04/03/2026 16:56:55 04/03/2026 15:57:28 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 04/03/2026 16:56:55 04/03/2026 15:57:33 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 04/03/2026 16:56:55 04/03/2026 15:57:39 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 04/03/2026 16:56:55 04/03/2026 15:57:50 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 04/03/2026 16:56:55 04/03/2026 15:57:55 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 04/03/2026 16:56:55 04/03/2026 15:58:01 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 04/03/2026 16:46:53 04/03/2026 15:46:29 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 04/03/2026 16:46:53 04/03/2026 15:46:35 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 04/03/2026 16:46:53 04/03/2026 15:46:47 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 04/03/2026 16:46:53 04/03/2026 15:46:53 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 04/03/2026 16:46:53 04/03/2026 15:46:59 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 04/03/2026 16:46:53 04/03/2026 15:47:04 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 04/03/2026 06:27:04 04/03/2026 06:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/03/2026 06:26:36 03/03/2026 06:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/03/2026 12:57:08 02/03/2026 11:56:45 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/03/2026 12:57:08 02/03/2026 11:57:08 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/03/2026 12:53:36 02/03/2026 11:53:13 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/03/2026 12:53:36 02/03/2026 11:54:06 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/03/2026 06:26:38 02/03/2026 06:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/03/2026 06:26:39 01/03/2026 06:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/02/2026 10:35:43 28/02/2026 09:35:21 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 28/02/2026 10:35:43 28/02/2026 09:35:58 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 28/02/2026 06:26:41 28/02/2026 06:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/02/2026 06:26:42 27/02/2026 06:26:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/02/2026 06:26:44 26/02/2026 06:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/02/2026 06:26:45 25/02/2026 06:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/02/2026 06:26:47 24/02/2026 06:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/02/2026 06:26:48 23/02/2026 06:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/02/2026 06:26:50 22/02/2026 06:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/02/2026 06:26:52 21/02/2026 06:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/02/2026 06:26:53 20/02/2026 06:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/02/2026 10:30:56 19/02/2026 09:30:37 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 19/02/2026 10:30:56 19/02/2026 09:30:43 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 19/02/2026 10:30:56 19/02/2026 09:31:12 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 19/02/2026 10:30:56 19/02/2026 09:31:18 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 19/02/2026 06:26:55 19/02/2026 06:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/02/2026 06:26:57 18/02/2026 06:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/02/2026 06:26:58 17/02/2026 06:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/02/2026 06:26:59 16/02/2026 06:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/02/2026 06:27:01 15/02/2026 06:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/02/2026 06:27:02 14/02/2026 06:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/02/2026 06:27:04 13/02/2026 06:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/02/2026 06:27:05 12/02/2026 06:27:10 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/02/2026 06:27:07 11/02/2026 06:27:12 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/02/2026 06:26:29 11/02/2026 06:26:34 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/02/2026 05:53:44 11/02/2026 03:53:42 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 11/02/2026 05:48:37 11/02/2026 03:47:59 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 11/02/2026 05:47:04 11/02/2026 03:46:25 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 10/02/2026 06:26:31 10/02/2026 06:26:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/02/2026 06:26:33 09/02/2026 06:26:38 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/02/2026 06:26:35 08/02/2026 06:26:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/02/2026 06:26:36 07/02/2026 06:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/02/2026 06:26:38 06/02/2026 06:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/02/2026 06:26:39 05/02/2026 06:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/02/2026 06:26:41 04/02/2026 06:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/02/2026 06:26:42 03/02/2026 06:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/02/2026 06:26:44 02/02/2026 06:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/02/2026 06:26:46 01/02/2026 06:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/01/2026 06:26:47 31/01/2026 06:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/01/2026 06:26:49 30/01/2026 06:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/01/2026 06:26:51 29/01/2026 06:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/01/2026 06:26:51 28/01/2026 06:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/01/2026 06:26:53 27/01/2026 06:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/01/2026 06:26:55 26/01/2026 06:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/01/2026 06:26:57 25/01/2026 06:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/01/2026 06:26:59 24/01/2026 06:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/01/2026 06:27:00 23/01/2026 06:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/01/2026 06:27:02 22/01/2026 06:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/01/2026 06:27:03 21/01/2026 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/01/2026 06:29:30 20/01/2026 06:29:35 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/01/2026 06:29:32 19/01/2026 06:29:37 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/01/2026 06:29:34 18/01/2026 06:29:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/01/2026 06:29:36 17/01/2026 06:29:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/01/2026 06:29:37 16/01/2026 06:29:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/01/2026 11:06:34 15/01/2026 10:06:27 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 15/01/2026 11:06:34 15/01/2026 10:06:46 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 15/01/2026 10:45:19 15/01/2026 09:45:12 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 15/01/2026 10:45:19 15/01/2026 09:45:24 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 15/01/2026 06:29:38 15/01/2026 06:29:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/01/2026 06:29:40 14/01/2026 06:29:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/01/2026 06:26:41 14/01/2026 06:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/01/2026 14:14:48 13/01/2026 12:14:55 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 13/01/2026 14:10:40 13/01/2026 12:10:46 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 13/01/2026 14:07:37 13/01/2026 12:07:43 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 13/01/2026 14:06:45 13/01/2026 12:03:53 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 13/01/2026 14:05:09 13/01/2026 12:05:16 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 13/01/2026 14:02:41 13/01/2026 11:59:50 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 13/01/2026 13:15:12 13/01/2026 12:15:15 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 13/01/2026 13:15:12 13/01/2026 12:15:43 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 13/01/2026 13:15:12 13/01/2026 12:15:49 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 13/01/2026 13:15:12 13/01/2026 12:15:55 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 13/01/2026 13:15:12 13/01/2026 12:16:00 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 13/01/2026 13:15:12 13/01/2026 12:16:17 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 13:08:23 13/01/2026 12:08:34 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 13/01/2026 13:08:23 13/01/2026 12:08:51 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 13/01/2026 13:08:23 13/01/2026 12:08:57 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 13/01/2026 13:07:59 13/01/2026 12:08:06 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 13:07:59 13/01/2026 12:08:12 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 13:04:17 13/01/2026 12:09:26 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 13/01/2026 13:04:16 13/01/2026 12:04:53 44139966 44139966 1,0 1002 Elevator Failure Serial communication broken on board (TTS-1)
KRM_SERVER 13/01/2026 13:04:16 13/01/2026 12:05:00 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 13/01/2026 13:04:10 13/01/2026 12:04:05 44139966 44139966 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 13/01/2026 13:04:10 13/01/2026 12:04:13 44139966 44139966 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 13/01/2026 13:04:10 13/01/2026 12:04:36 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 13/01/2026 13:04:10 13/01/2026 12:04:42 44139966 44139966 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 13/01/2026 13:04:10 13/01/2026 12:04:48 44139966 44139966 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 13/01/2026 12:58:44 13/01/2026 11:58:44 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 13/01/2026 12:58:44 13/01/2026 11:58:50 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 13/01/2026 12:58:44 13/01/2026 11:58:56 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 12:58:44 13/01/2026 11:59:01 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 13/01/2026 12:58:44 13/01/2026 11:59:06 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 13/01/2026 12:58:44 13/01/2026 11:59:12 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 12:58:44 13/01/2026 11:59:28 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 12:58:21 13/01/2026 11:57:47 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 12:58:21 13/01/2026 11:57:54 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 13/01/2026 12:58:21 13/01/2026 11:57:58 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 13/01/2026 12:58:21 13/01/2026 11:58:04 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 12:58:21 13/01/2026 11:58:15 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 13/01/2026 12:58:21 13/01/2026 11:58:21 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 13/01/2026 12:58:21 13/01/2026 11:59:17 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 13/01/2026 12:56:33 13/01/2026 11:56:22 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 13/01/2026 12:56:33 13/01/2026 11:56:28 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 13/01/2026 12:55:59 13/01/2026 11:55:29 44139966 44139966 1,0 1091 Elevator Failure Lift on final limit magnet
KRM_SERVER 13/01/2026 12:55:59 13/01/2026 11:55:42 44139966 44139966 1,0 1091 Elevator Failure Lift on final limit magnet
KRM_SERVER 13/01/2026 12:55:58 13/01/2026 11:55:24 44139966 44139966 1,0 1091 Elevator Failure Lift on final limit magnet
KRM_SERVER 13/01/2026 12:55:58 13/01/2026 11:55:37 44139966 44139966 1,0 1091 Elevator Failure Lift on final limit magnet
KRM_SERVER 13/01/2026 12:54:49 13/01/2026 11:54:16 44139966 44139966 1,0 1091 Elevator Failure Lift on final limit magnet
KRM_SERVER 13/01/2026 12:54:49 13/01/2026 11:54:22 44139966 44139966 1,0 1091 Elevator Failure Lift on final limit magnet
KRM_SERVER 13/01/2026 12:54:49 13/01/2026 11:54:27 44139966 44139966 1,0 1091 Elevator Failure Lift on final limit magnet
KRM_SERVER 13/01/2026 12:54:40 13/01/2026 11:54:11 44139966 44139966 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 13/01/2026 12:54:40 13/01/2026 11:54:39 44139966 44139966 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 13/01/2026 12:54:40 13/01/2026 11:54:50 44139966 44139966 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 13/01/2026 12:54:40 13/01/2026 11:54:56 44139966 44139966 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 13/01/2026 12:54:40 13/01/2026 11:55:01 44139966 44139966 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 13/01/2026 12:51:54 13/01/2026 11:51:19 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 13/01/2026 12:51:54 13/01/2026 11:51:27 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 13/01/2026 12:51:54 13/01/2026 11:51:31 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 13/01/2026 12:51:54 13/01/2026 11:51:38 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 13/01/2026 12:48:23 13/01/2026 11:47:53 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 13/01/2026 12:48:23 13/01/2026 11:50:55 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 13/01/2026 12:48:22 13/01/2026 11:47:47 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 13/01/2026 12:48:22 13/01/2026 11:50:49 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 13/01/2026 12:46:53 13/01/2026 11:46:18 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 12:46:53 13/01/2026 11:46:23 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 13/01/2026 12:46:53 13/01/2026 11:46:31 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 13/01/2026 12:46:53 13/01/2026 11:46:48 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 12:46:53 13/01/2026 11:46:53 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 13/01/2026 12:46:53 13/01/2026 11:46:59 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 13/01/2026 12:46:53 13/01/2026 11:47:10 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 13/01/2026 12:46:53 13/01/2026 11:47:15 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 13/01/2026 12:46:53 13/01/2026 11:50:11 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 13/01/2026 12:46:53 13/01/2026 11:50:16 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 13/01/2026 12:46:53 13/01/2026 11:52:11 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 12:46:53 13/01/2026 11:52:17 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 12:44:36 13/01/2026 11:44:11 44139966 44139966 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 13/01/2026 12:44:36 13/01/2026 11:44:18 44139966 44139966 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 13/01/2026 12:44:35 13/01/2026 11:44:05 44139966 44139966 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 13/01/2026 12:44:35 13/01/2026 11:44:22 44139966 44139966 1,0 1140 Elevator Failure Safety circuit: Inspection up limit
KRM_SERVER 13/01/2026 12:27:11 13/01/2026 11:27:09 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 13/01/2026 12:27:11 13/01/2026 11:27:14 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 13/01/2026 12:27:11 13/01/2026 11:28:34 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 13/01/2026 12:27:11 13/01/2026 11:28:39 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 13/01/2026 12:26:18 13/01/2026 11:25:43 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 12:26:18 13/01/2026 11:25:48 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 13/01/2026 12:26:18 13/01/2026 11:25:55 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 13/01/2026 12:26:18 13/01/2026 11:25:59 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 13/01/2026 12:26:18 13/01/2026 11:26:11 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 12:26:18 13/01/2026 11:26:17 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 13/01/2026 12:26:18 13/01/2026 11:26:22 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 13/01/2026 12:26:18 13/01/2026 11:26:28 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 13/01/2026 12:26:18 13/01/2026 11:26:39 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 13/01/2026 12:26:18 13/01/2026 11:26:45 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 13/01/2026 12:26:18 13/01/2026 11:26:50 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 13/01/2026 12:26:18 13/01/2026 11:26:56 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 13/01/2026 12:26:18 13/01/2026 11:27:57 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 13/01/2026 12:26:18 13/01/2026 11:28:03 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 13/01/2026 12:26:18 13/01/2026 11:46:43 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 12:26:18 13/01/2026 11:47:04 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 12:26:04 13/01/2026 11:25:34 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 12:26:04 13/01/2026 11:26:35 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 12:26:03 13/01/2026 11:25:28 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 12:26:03 13/01/2026 11:26:06 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 13/01/2026 12:00:23 13/01/2026 12:00:23 44139966 44139966 1,0 100 Temporary Fault Unclassified Alarm
KRM_SERVER 13/01/2026 11:30:50 13/01/2026 10:30:15 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 13/01/2026 11:30:50 13/01/2026 10:30:51 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 13/01/2026 11:13:00 13/01/2026 10:12:25 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 13/01/2026 11:13:00 13/01/2026 10:13:53 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 13/01/2026 08:41:13 13/01/2026 07:40:38 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 13/01/2026 08:41:13 13/01/2026 07:40:44 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 13/01/2026 06:26:43 13/01/2026 06:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/01/2026 09:14:28 12/01/2026 08:13:53 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/01/2026 09:14:28 12/01/2026 08:14:54 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/01/2026 09:06:41 12/01/2026 08:06:07 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/01/2026 09:06:41 12/01/2026 08:11:18 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/01/2026 06:26:45 12/01/2026 06:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/01/2026 06:26:46 11/01/2026 06:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/01/2026 06:26:48 10/01/2026 06:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/01/2026 11:40:27 09/01/2026 10:39:54 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/01/2026 11:40:27 09/01/2026 10:40:29 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/01/2026 06:26:50 09/01/2026 06:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/01/2026 06:26:52 08/01/2026 06:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/01/2026 06:26:53 07/01/2026 06:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/01/2026 06:26:54 06/01/2026 06:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/01/2026 06:26:57 05/01/2026 06:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/01/2026 06:26:58 04/01/2026 06:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/01/2026 06:26:59 03/01/2026 06:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/01/2026 06:27:01 02/01/2026 06:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/01/2026 06:27:03 01/01/2026 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/12/2025 06:27:03 31/12/2025 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/12/2025 06:26:33 30/12/2025 06:26:38 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/12/2025 06:26:34 29/12/2025 06:26:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/12/2025 06:26:36 28/12/2025 06:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/12/2025 06:26:37 27/12/2025 06:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/12/2025 06:26:39 26/12/2025 06:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/12/2025 06:26:40 25/12/2025 06:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/12/2025 06:26:42 24/12/2025 06:26:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/12/2025 16:40:53 23/12/2025 15:40:43 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/12/2025 06:26:44 23/12/2025 06:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/12/2025 06:26:45 22/12/2025 06:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/12/2025 06:26:47 21/12/2025 06:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/12/2025 06:26:48 20/12/2025 06:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/12/2025 06:26:49 19/12/2025 06:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/12/2025 11:33:52 18/12/2025 10:33:29 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/12/2025 11:33:52 18/12/2025 10:34:51 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/12/2025 06:26:51 18/12/2025 06:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/12/2025 06:26:53 17/12/2025 06:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/12/2025 06:26:55 16/12/2025 06:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/12/2025 06:26:56 15/12/2025 06:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/12/2025 06:26:58 14/12/2025 06:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/12/2025 06:26:59 13/12/2025 06:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/12/2025 06:27:00 12/12/2025 06:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/12/2025 07:27:02 11/12/2025 07:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/12/2025 06:27:02 11/12/2025 06:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/12/2025 07:27:03 10/12/2025 07:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/12/2025 06:27:03 10/12/2025 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/12/2025 07:26:31 09/12/2025 07:26:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/12/2025 06:26:31 09/12/2025 06:26:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/12/2025 07:26:33 08/12/2025 07:26:38 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/12/2025 06:26:33 08/12/2025 06:26:38 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/12/2025 15:49:09 07/12/2025 14:48:52 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 07/12/2025 15:49:09 07/12/2025 14:49:55 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 07/12/2025 07:26:35 07/12/2025 07:26:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/12/2025 06:26:35 07/12/2025 06:26:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/12/2025 07:26:37 06/12/2025 07:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/12/2025 06:26:37 06/12/2025 06:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/12/2025 07:26:37 05/12/2025 07:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/12/2025 06:26:37 05/12/2025 06:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/12/2025 07:26:39 04/12/2025 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/12/2025 06:26:39 04/12/2025 06:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/12/2025 07:26:41 03/12/2025 07:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/12/2025 06:26:41 03/12/2025 06:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/12/2025 07:26:45 02/12/2025 07:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/12/2025 06:26:45 02/12/2025 06:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/12/2025 06:26:44 01/12/2025 06:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/11/2025 06:26:46 30/11/2025 06:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/11/2025 06:26:48 29/11/2025 06:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/11/2025 06:26:49 28/11/2025 06:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/11/2025 06:26:50 27/11/2025 06:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/11/2025 06:26:52 26/11/2025 06:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/11/2025 06:26:54 25/11/2025 06:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/11/2025 06:26:55 24/11/2025 06:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/11/2025 06:26:57 23/11/2025 06:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/11/2025 06:26:59 22/11/2025 06:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/11/2025 06:27:00 21/11/2025 06:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/11/2025 09:29:49 20/11/2025 08:30:18 44139966 44139966 1,0 1091 Elevator Failure Lift on final limit magnet
KRM_SERVER 20/11/2025 09:29:48 20/11/2025 08:30:24 44139966 44139966 1,0 1091 Elevator Failure Lift on final limit magnet
KRM_SERVER 20/11/2025 09:29:36 20/11/2025 08:29:32 44139966 44139966 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 20/11/2025 09:29:36 20/11/2025 08:29:43 44139966 44139966 1,0 1012 Elevator Failure Rear car door contact opened during drive (C6)
KRM_SERVER 20/11/2025 09:29:36 20/11/2025 08:29:49 44139966 44139966 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 20/11/2025 09:29:36 20/11/2025 08:29:55 44139966 44139966 1,0 1012 Elevator Failure Rear car door contact opened during drive (C6)
KRM_SERVER 20/11/2025 09:29:36 20/11/2025 08:30:01 44139966 44139966 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 20/11/2025 09:29:36 20/11/2025 08:30:36 44139966 44139966 1,0 1012 Elevator Failure Rear car door contact opened during drive (C6)
KRM_SERVER 20/11/2025 09:29:36 20/11/2025 08:30:42 44139966 44139966 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 20/11/2025 09:29:36 20/11/2025 08:30:47 44139966 44139966 1,0 1012 Elevator Failure Rear car door contact opened during drive (C6)
KRM_SERVER 20/11/2025 09:28:44 20/11/2025 08:28:45 44139966 44139966 1,0 1091 Elevator Failure Lift on final limit magnet
KRM_SERVER 20/11/2025 09:28:44 20/11/2025 08:28:50 44139966 44139966 1,0 1091 Elevator Failure Lift on final limit magnet
KRM_SERVER 20/11/2025 09:28:44 20/11/2025 08:28:58 44139966 44139966 1,0 1091 Elevator Failure Lift on final limit magnet
KRM_SERVER 20/11/2025 09:28:44 20/11/2025 08:29:03 44139966 44139966 1,0 1091 Elevator Failure Lift on final limit magnet
KRM_SERVER 20/11/2025 08:27:31 20/11/2025 08:27:30 44139966 44139966 1,0 102 Temporary Fault Test Alarm
KRM_SERVER 20/11/2025 06:27:01 20/11/2025 06:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/11/2025 13:10:16 19/11/2025 12:10:35 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 19/11/2025 13:10:16 19/11/2025 12:10:42 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 19/11/2025 13:10:16 19/11/2025 12:11:05 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 19/11/2025 13:10:16 19/11/2025 12:11:11 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 19/11/2025 13:09:10 19/11/2025 12:09:39 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 19/11/2025 13:09:10 19/11/2025 12:09:56 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 13:09:10 19/11/2025 12:10:01 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 19/11/2025 13:09:10 19/11/2025 12:10:18 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 19/11/2025 13:09:10 19/11/2025 12:10:24 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 19/11/2025 13:09:10 19/11/2025 12:10:48 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 19/11/2025 13:09:10 19/11/2025 12:10:53 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 19/11/2025 13:09:10 19/11/2025 12:11:43 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 13:09:09 19/11/2025 12:09:26 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 19/11/2025 13:09:09 19/11/2025 12:10:13 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 19/11/2025 13:09:05 19/11/2025 12:08:55 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 19/11/2025 13:09:05 19/11/2025 12:09:07 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 19/11/2025 13:09:05 19/11/2025 12:09:13 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 19/11/2025 13:09:05 19/11/2025 12:09:20 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 19/11/2025 13:01:17 19/11/2025 12:01:31 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 19/11/2025 13:01:17 19/11/2025 12:01:36 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 19/11/2025 13:01:17 19/11/2025 12:01:48 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 19/11/2025 13:01:17 19/11/2025 12:01:59 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 19/11/2025 13:01:16 19/11/2025 12:01:13 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 19/11/2025 13:01:16 19/11/2025 12:01:25 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 19/11/2025 13:01:16 19/11/2025 12:01:42 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 19/11/2025 13:01:16 19/11/2025 12:01:53 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 19/11/2025 12:59:42 19/11/2025 12:02:12 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 19/11/2025 12:59:42 19/11/2025 12:02:17 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 19/11/2025 12:59:42 19/11/2025 12:02:23 44139966 44139966 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 19/11/2025 12:59:42 19/11/2025 12:02:28 44139966 44139966 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 19/11/2025 12:59:42 19/11/2025 12:05:56 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 19/11/2025 12:59:38 19/11/2025 12:00:46 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 19/11/2025 12:59:38 19/11/2025 12:00:51 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 12:59:38 19/11/2025 12:00:57 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 19/11/2025 12:59:38 19/11/2025 12:02:34 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 19/11/2025 12:59:38 19/11/2025 12:02:41 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 19/11/2025 12:59:38 19/11/2025 12:02:47 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 19/11/2025 12:59:38 19/11/2025 12:02:53 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 19/11/2025 12:59:38 19/11/2025 12:05:50 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 19/11/2025 12:59:38 19/11/2025 12:09:44 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 12:59:33 19/11/2025 11:59:24 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 19/11/2025 12:59:33 19/11/2025 11:59:30 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 19/11/2025 12:59:33 19/11/2025 11:59:42 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 19/11/2025 12:59:33 19/11/2025 11:59:47 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 19/11/2025 12:59:24 19/11/2025 11:59:18 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 19/11/2025 12:59:24 19/11/2025 12:00:04 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 19/11/2025 12:59:23 19/11/2025 11:59:13 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 19/11/2025 12:59:23 19/11/2025 12:00:38 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 19/11/2025 12:59:12 19/11/2025 11:59:07 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 19/11/2025 12:59:12 19/11/2025 11:59:58 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 19/11/2025 12:59:11 19/11/2025 11:59:02 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 19/11/2025 12:59:11 19/11/2025 12:00:32 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 19/11/2025 12:54:37 19/11/2025 11:54:49 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 19/11/2025 12:54:37 19/11/2025 11:54:54 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 12:54:37 19/11/2025 11:59:53 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 19/11/2025 12:54:37 19/11/2025 12:10:07 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 12:54:36 19/11/2025 11:54:27 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 12:54:36 19/11/2025 11:54:32 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 19/11/2025 12:54:36 19/11/2025 12:00:21 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 12:54:36 19/11/2025 12:00:27 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 19/11/2025 12:54:10 19/11/2025 11:54:05 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 12:54:10 19/11/2025 11:54:11 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 12:54:10 19/11/2025 11:54:38 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 12:54:10 19/11/2025 11:55:00 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 12:49:15 19/11/2025 11:49:31 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 12:49:15 19/11/2025 11:49:31 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 12:49:15 19/11/2025 11:52:42 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 12:49:15 19/11/2025 11:52:47 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 12:40:03 19/11/2025 11:40:00 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 12:40:03 19/11/2025 11:40:05 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 12:40:03 19/11/2025 11:41:06 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 12:40:03 19/11/2025 11:41:12 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 19/11/2025 06:27:03 19/11/2025 15:50:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/11/2025 06:26:31 18/11/2025 06:26:37 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/11/2025 06:26:33 17/11/2025 06:26:38 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/11/2025 06:26:35 16/11/2025 06:26:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/11/2025 06:26:36 15/11/2025 06:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/11/2025 06:26:38 14/11/2025 06:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/11/2025 06:26:40 13/11/2025 06:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/11/2025 06:26:41 12/11/2025 06:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/11/2025 06:26:43 11/11/2025 06:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/11/2025 06:26:44 10/11/2025 06:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/11/2025 06:26:46 09/11/2025 06:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/11/2025 06:26:47 08/11/2025 06:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/11/2025 22:01:16 07/11/2025 21:01:11 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 07/11/2025 22:01:16 07/11/2025 21:02:33 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 07/11/2025 06:26:48 07/11/2025 06:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/11/2025 06:26:50 06/11/2025 06:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/11/2025 06:26:52 05/11/2025 06:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/11/2025 06:26:53 04/11/2025 06:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/11/2025 06:26:55 03/11/2025 06:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/11/2025 06:26:56 02/11/2025 06:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/11/2025 06:26:58 01/11/2025 06:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/10/2025 06:27:00 31/10/2025 06:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/10/2025 16:29:11 30/10/2025 15:29:09 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/10/2025 16:29:11 30/10/2025 15:29:22 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/10/2025 12:19:14 30/10/2025 11:19:25 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 30/10/2025 12:19:14 30/10/2025 11:27:16 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 30/10/2025 12:19:13 30/10/2025 11:19:18 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 30/10/2025 12:19:13 30/10/2025 11:27:11 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 30/10/2025 12:00:18 30/10/2025 11:00:17 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 30/10/2025 12:00:18 30/10/2025 11:00:22 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 30/10/2025 12:00:18 30/10/2025 11:00:28 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 30/10/2025 12:00:18 30/10/2025 11:00:34 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 30/10/2025 12:00:18 30/10/2025 11:00:40 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 30/10/2025 12:00:18 30/10/2025 11:00:46 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 30/10/2025 12:00:18 30/10/2025 11:16:25 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 30/10/2025 12:00:18 30/10/2025 11:16:30 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 30/10/2025 12:00:18 30/10/2025 11:16:36 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 30/10/2025 12:00:18 30/10/2025 11:16:41 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 30/10/2025 12:00:18 30/10/2025 11:16:46 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 30/10/2025 12:00:18 30/10/2025 11:16:52 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 30/10/2025 06:27:01 30/10/2025 06:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/10/2025 06:27:03 29/10/2025 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/10/2025 06:26:33 28/10/2025 06:26:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/10/2025 06:26:34 27/10/2025 06:26:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/10/2025 07:26:36 26/10/2025 07:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/10/2025 07:26:38 25/10/2025 07:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/10/2025 07:26:39 24/10/2025 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/10/2025 07:26:40 23/10/2025 07:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/10/2025 15:55:29 22/10/2025 15:55:43 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:55:29 22/10/2025 16:08:03 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:55:28 22/10/2025 15:55:36 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:55:28 22/10/2025 16:07:58 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:51:13 22/10/2025 15:51:20 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:51:13 22/10/2025 15:51:26 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:51:13 22/10/2025 15:53:17 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:51:13 22/10/2025 15:53:29 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:44:45 22/10/2025 15:44:54 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/10/2025 15:44:45 22/10/2025 15:45:07 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/10/2025 15:35:36 22/10/2025 15:35:49 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:35:36 22/10/2025 15:36:01 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:35:36 22/10/2025 15:41:10 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:35:36 22/10/2025 15:41:16 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:35:12 22/10/2025 15:35:19 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/10/2025 15:35:12 22/10/2025 15:35:37 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/10/2025 15:22:28 22/10/2025 15:22:34 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:22:28 22/10/2025 15:22:46 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:22:28 22/10/2025 15:31:18 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:22:28 22/10/2025 15:31:25 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:21:52 22/10/2025 15:21:59 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/10/2025 15:21:52 22/10/2025 15:22:11 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/10/2025 15:18:42 22/10/2025 15:18:50 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/10/2025 15:18:42 22/10/2025 15:19:01 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/10/2025 15:02:23 22/10/2025 15:02:25 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:02:23 22/10/2025 15:02:35 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 22/10/2025 15:02:23 22/10/2025 15:02:41 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 22/10/2025 15:02:23 22/10/2025 15:02:43 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:02:23 22/10/2025 15:02:49 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 22/10/2025 15:02:23 22/10/2025 15:03:00 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 22/10/2025 15:02:23 22/10/2025 15:10:38 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 22/10/2025 15:02:23 22/10/2025 15:10:44 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 22/10/2025 15:02:23 22/10/2025 15:10:49 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 22/10/2025 15:02:23 22/10/2025 15:10:55 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 22/10/2025 15:02:23 22/10/2025 15:11:01 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 15:02:23 22/10/2025 15:11:07 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 22/10/2025 12:49:39 22/10/2025 12:49:51 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/10/2025 12:49:39 22/10/2025 12:50:08 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/10/2025 10:10:05 22/10/2025 10:10:12 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/10/2025 10:10:05 22/10/2025 10:10:25 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/10/2025 08:59:43 22/10/2025 08:59:52 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/10/2025 08:59:43 22/10/2025 09:00:03 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/10/2025 08:58:54 22/10/2025 08:59:02 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/10/2025 08:58:54 22/10/2025 08:59:12 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/10/2025 08:50:51 22/10/2025 08:51:00 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/10/2025 07:26:42 22/10/2025 07:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/10/2025 19:09:04 21/10/2025 19:09:19 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/10/2025 19:09:04 21/10/2025 19:09:29 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/10/2025 14:05:09 21/10/2025 14:05:17 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/10/2025 14:05:09 21/10/2025 14:05:28 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/10/2025 11:40:04 21/10/2025 11:40:13 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/10/2025 11:40:04 21/10/2025 11:40:24 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/10/2025 10:27:48 21/10/2025 10:28:05 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/10/2025 10:27:48 21/10/2025 10:28:17 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/10/2025 09:09:40 21/10/2025 09:09:50 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/10/2025 09:09:40 21/10/2025 09:10:02 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/10/2025 09:09:02 21/10/2025 09:09:09 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/10/2025 09:09:02 21/10/2025 09:09:22 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/10/2025 07:26:43 21/10/2025 07:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/10/2025 07:17:39 21/10/2025 07:17:54 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/10/2025 07:17:39 21/10/2025 07:18:05 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 20/10/2025 12:39:47 20/10/2025 12:39:56 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 20/10/2025 12:39:47 20/10/2025 12:40:07 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 20/10/2025 09:40:58 20/10/2025 09:41:13 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 20/10/2025 09:40:58 20/10/2025 09:41:31 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 20/10/2025 07:26:45 20/10/2025 07:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/10/2025 22:08:19 19/10/2025 22:08:27 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 19/10/2025 22:08:19 19/10/2025 22:08:38 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 19/10/2025 20:06:50 19/10/2025 20:07:00 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 19/10/2025 20:06:50 19/10/2025 20:07:11 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 19/10/2025 12:59:19 19/10/2025 12:59:27 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 19/10/2025 12:59:19 19/10/2025 12:59:38 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 19/10/2025 12:54:13 19/10/2025 12:54:28 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 19/10/2025 12:54:13 19/10/2025 12:54:40 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 19/10/2025 11:23:29 19/10/2025 11:23:38 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 19/10/2025 11:23:29 19/10/2025 11:23:50 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 19/10/2025 10:47:32 19/10/2025 10:47:40 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 19/10/2025 07:26:46 19/10/2025 07:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/10/2025 19:19:22 18/10/2025 19:19:37 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 18/10/2025 19:19:22 18/10/2025 19:19:50 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 18/10/2025 19:04:41 18/10/2025 19:04:50 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 18/10/2025 19:04:41 18/10/2025 19:05:01 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 18/10/2025 14:47:04 18/10/2025 14:47:13 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 18/10/2025 14:47:04 18/10/2025 14:47:24 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 18/10/2025 12:36:31 18/10/2025 12:36:35 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 18/10/2025 12:36:31 18/10/2025 12:36:46 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 18/10/2025 11:56:38 18/10/2025 11:56:47 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 18/10/2025 11:56:38 18/10/2025 11:56:58 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 18/10/2025 07:26:48 18/10/2025 07:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/10/2025 06:11:33 18/10/2025 06:11:41 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 18/10/2025 06:11:33 18/10/2025 06:11:52 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 17/10/2025 21:21:03 17/10/2025 21:21:06 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/10/2025 21:21:03 17/10/2025 21:21:11 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/10/2025 11:10:19 17/10/2025 11:10:35 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 17/10/2025 11:09:34 17/10/2025 11:09:50 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 17/10/2025 11:09:34 17/10/2025 11:10:03 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 17/10/2025 10:40:50 17/10/2025 10:41:05 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 17/10/2025 10:40:50 17/10/2025 10:41:17 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 17/10/2025 07:26:50 17/10/2025 07:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/10/2025 18:05:33 16/10/2025 18:05:42 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 16/10/2025 18:05:33 16/10/2025 18:05:53 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 16/10/2025 14:11:01 16/10/2025 14:11:11 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 16/10/2025 14:11:01 16/10/2025 14:11:22 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 16/10/2025 07:26:51 16/10/2025 07:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/10/2025 19:42:13 15/10/2025 19:42:25 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 15/10/2025 19:42:13 15/10/2025 19:42:36 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 15/10/2025 19:35:21 15/10/2025 19:35:31 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 15/10/2025 19:35:21 15/10/2025 19:35:48 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 15/10/2025 19:21:20 15/10/2025 19:21:33 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 15/10/2025 19:21:20 15/10/2025 19:21:44 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 15/10/2025 07:26:52 15/10/2025 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/10/2025 21:13:54 14/10/2025 21:14:04 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/10/2025 21:13:54 14/10/2025 21:14:15 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/10/2025 20:40:09 14/10/2025 20:40:25 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/10/2025 20:40:09 14/10/2025 20:40:38 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/10/2025 16:34:04 14/10/2025 16:34:15 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/10/2025 16:34:04 14/10/2025 16:34:28 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/10/2025 12:49:34 14/10/2025 12:49:47 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/10/2025 12:49:34 14/10/2025 12:49:58 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/10/2025 12:07:57 14/10/2025 12:08:08 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/10/2025 12:07:57 14/10/2025 12:08:21 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/10/2025 10:31:33 14/10/2025 10:31:44 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/10/2025 10:31:33 14/10/2025 10:31:57 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/10/2025 07:26:54 14/10/2025 07:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/10/2025 11:57:56 13/10/2025 11:58:00 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 13/10/2025 11:57:56 13/10/2025 11:58:13 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 13/10/2025 10:14:32 13/10/2025 10:14:46 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 13/10/2025 07:26:55 13/10/2025 07:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/10/2025 07:26:57 12/10/2025 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/10/2025 07:26:59 11/10/2025 07:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/10/2025 16:12:44 10/10/2025 16:13:27 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 10/10/2025 16:11:37 10/10/2025 16:12:00 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 10/10/2025 16:11:37 10/10/2025 16:12:12 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 10/10/2025 16:11:37 10/10/2025 16:13:59 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 10/10/2025 15:13:19 10/10/2025 15:13:26 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 10/10/2025 15:13:19 10/10/2025 15:14:48 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 10/10/2025 15:13:19 10/10/2025 15:14:53 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 10/10/2025 15:11:49 10/10/2025 15:11:52 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 10/10/2025 15:11:49 10/10/2025 15:11:57 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 10/10/2025 15:11:49 10/10/2025 15:12:03 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 10/10/2025 15:11:49 10/10/2025 15:12:08 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 10/10/2025 15:11:49 10/10/2025 15:12:25 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 10/10/2025 15:11:49 10/10/2025 15:13:56 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 10/10/2025 15:11:47 10/10/2025 15:12:36 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 10/10/2025 15:11:47 10/10/2025 15:12:48 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 10/10/2025 15:09:51 10/10/2025 15:09:50 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 10/10/2025 15:09:51 10/10/2025 15:13:10 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 10/10/2025 15:04:55 10/10/2025 15:05:00 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 10/10/2025 15:04:55 10/10/2025 15:05:13 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 10/10/2025 13:29:49 10/10/2025 13:29:53 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 10/10/2025 13:29:49 10/10/2025 13:30:06 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 10/10/2025 10:49:27 10/10/2025 10:49:43 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 10/10/2025 10:49:27 10/10/2025 10:49:55 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 10/10/2025 08:46:07 10/10/2025 08:47:04 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 10/10/2025 08:23:08 10/10/2025 08:23:30 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 10/10/2025 07:26:59 10/10/2025 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/10/2025 17:36:41 09/10/2025 17:36:56 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 09/10/2025 08:04:36 09/10/2025 08:04:56 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 09/10/2025 07:27:02 09/10/2025 07:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/10/2025 16:18:30 08/10/2025 16:18:39 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 08/10/2025 13:41:50 08/10/2025 13:41:57 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 08/10/2025 13:41:50 08/10/2025 13:42:08 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 08/10/2025 11:47:51 08/10/2025 11:47:58 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 08/10/2025 11:47:51 08/10/2025 11:48:23 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 08/10/2025 09:56:10 08/10/2025 09:56:15 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 08/10/2025 09:56:10 08/10/2025 09:56:51 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 08/10/2025 09:37:19 08/10/2025 09:37:23 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 08/10/2025 09:37:19 08/10/2025 09:37:35 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 08/10/2025 08:45:21 08/10/2025 08:45:27 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 08/10/2025 08:45:21 08/10/2025 08:45:39 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 08/10/2025 07:27:02 08/10/2025 07:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/10/2025 15:15:21 07/10/2025 15:15:28 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 07/10/2025 15:15:21 07/10/2025 15:15:39 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 07/10/2025 12:43:33 07/10/2025 12:46:24 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 07/10/2025 12:43:33 07/10/2025 12:47:08 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 07/10/2025 10:46:17 07/10/2025 10:46:24 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 07/10/2025 10:46:17 07/10/2025 10:46:35 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 07/10/2025 07:26:33 07/10/2025 07:26:38 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/10/2025 13:02:25 06/10/2025 13:02:31 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 06/10/2025 13:02:25 06/10/2025 13:02:42 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 06/10/2025 10:48:54 06/10/2025 10:49:06 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 06/10/2025 10:48:54 06/10/2025 10:49:16 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 06/10/2025 09:16:27 06/10/2025 09:16:33 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 06/10/2025 09:16:27 06/10/2025 09:16:44 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 06/10/2025 07:26:35 06/10/2025 07:26:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/10/2025 18:51:37 05/10/2025 18:51:47 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 05/10/2025 18:51:37 05/10/2025 18:51:57 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 05/10/2025 11:46:48 05/10/2025 11:46:55 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 05/10/2025 11:46:48 05/10/2025 11:47:06 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 05/10/2025 11:29:24 05/10/2025 11:29:30 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 05/10/2025 11:29:24 05/10/2025 11:29:41 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 05/10/2025 08:30:32 05/10/2025 08:30:39 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 05/10/2025 08:30:32 05/10/2025 08:30:51 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 05/10/2025 07:26:36 05/10/2025 07:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/10/2025 21:59:36 04/10/2025 21:59:55 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 04/10/2025 21:59:36 04/10/2025 22:00:07 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 04/10/2025 21:09:08 04/10/2025 21:09:15 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 04/10/2025 21:09:08 04/10/2025 21:09:27 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 04/10/2025 07:26:38 04/10/2025 07:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/10/2025 16:33:51 03/10/2025 16:33:58 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 03/10/2025 16:33:51 03/10/2025 16:34:12 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 03/10/2025 15:02:17 03/10/2025 15:02:26 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 03/10/2025 15:02:17 03/10/2025 15:02:36 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 03/10/2025 13:14:59 03/10/2025 13:15:09 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 03/10/2025 13:14:59 03/10/2025 13:15:20 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 03/10/2025 09:17:08 03/10/2025 09:17:15 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 03/10/2025 09:17:08 03/10/2025 09:17:33 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 03/10/2025 07:26:40 03/10/2025 07:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/10/2025 15:49:37 02/10/2025 15:49:46 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 02/10/2025 15:49:37 02/10/2025 15:49:56 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 02/10/2025 15:44:44 02/10/2025 15:44:52 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 02/10/2025 15:44:44 02/10/2025 15:45:09 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 02/10/2025 14:32:06 02/10/2025 14:32:12 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 02/10/2025 14:32:06 02/10/2025 14:32:30 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 02/10/2025 14:18:36 02/10/2025 14:18:43 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 02/10/2025 14:18:36 02/10/2025 14:19:01 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 02/10/2025 12:54:39 02/10/2025 12:54:54 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 02/10/2025 12:54:39 02/10/2025 12:55:06 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 02/10/2025 12:49:26 02/10/2025 12:49:35 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 02/10/2025 12:49:26 02/10/2025 12:49:46 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 02/10/2025 10:47:34 02/10/2025 10:47:42 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 02/10/2025 10:47:34 02/10/2025 10:47:53 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 02/10/2025 07:26:42 02/10/2025 07:26:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/10/2025 09:45:14 01/10/2025 09:45:23 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 01/10/2025 09:45:14 01/10/2025 09:45:34 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 01/10/2025 09:38:25 01/10/2025 09:38:40 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 01/10/2025 09:38:25 01/10/2025 09:38:58 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 01/10/2025 07:26:43 01/10/2025 07:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/09/2025 19:36:38 30/09/2025 19:36:46 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 30/09/2025 19:36:38 30/09/2025 19:36:57 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 30/09/2025 15:58:00 30/09/2025 15:58:10 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 30/09/2025 15:58:00 30/09/2025 15:58:21 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 30/09/2025 15:02:50 30/09/2025 15:02:59 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 30/09/2025 15:02:50 30/09/2025 15:03:09 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 30/09/2025 12:43:27 30/09/2025 12:43:35 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 30/09/2025 12:43:27 30/09/2025 12:43:47 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 30/09/2025 11:56:32 30/09/2025 11:56:40 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 30/09/2025 11:56:32 30/09/2025 11:56:51 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 30/09/2025 11:47:33 30/09/2025 11:47:42 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 30/09/2025 11:47:33 30/09/2025 11:47:53 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 30/09/2025 09:09:42 30/09/2025 09:09:50 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 30/09/2025 09:09:42 30/09/2025 09:10:08 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 30/09/2025 07:26:44 30/09/2025 07:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/09/2025 16:50:03 29/09/2025 16:50:15 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 29/09/2025 16:50:03 29/09/2025 16:50:26 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 29/09/2025 09:33:15 29/09/2025 09:33:24 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 29/09/2025 09:33:15 29/09/2025 09:33:35 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 29/09/2025 09:14:28 29/09/2025 09:14:37 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 29/09/2025 09:14:28 29/09/2025 09:14:48 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 29/09/2025 07:26:46 29/09/2025 07:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/09/2025 07:26:48 28/09/2025 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/09/2025 06:46:24 28/09/2025 06:46:33 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 28/09/2025 06:46:24 28/09/2025 06:46:44 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 27/09/2025 22:46:28 27/09/2025 22:46:37 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 27/09/2025 22:46:28 27/09/2025 22:46:48 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 27/09/2025 18:38:45 27/09/2025 18:39:01 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 27/09/2025 18:38:45 27/09/2025 18:39:12 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 27/09/2025 16:42:35 27/09/2025 16:42:46 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 27/09/2025 16:42:35 27/09/2025 16:43:04 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 27/09/2025 09:59:18 27/09/2025 09:59:29 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 27/09/2025 09:59:18 27/09/2025 09:59:42 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 27/09/2025 07:26:49 27/09/2025 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/09/2025 07:01:27 27/09/2025 07:01:45 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 27/09/2025 07:01:27 27/09/2025 07:01:56 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 26/09/2025 20:58:10 26/09/2025 20:58:27 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 26/09/2025 20:58:10 26/09/2025 20:58:39 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 26/09/2025 18:23:32 26/09/2025 18:23:43 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 26/09/2025 18:23:32 26/09/2025 18:23:54 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 26/09/2025 18:09:18 26/09/2025 18:09:28 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 26/09/2025 18:09:18 26/09/2025 18:09:39 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 26/09/2025 16:39:40 26/09/2025 16:39:50 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 26/09/2025 16:39:40 26/09/2025 16:40:01 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 26/09/2025 16:34:45 26/09/2025 16:34:57 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 26/09/2025 16:34:45 26/09/2025 16:35:08 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 26/09/2025 16:24:30 26/09/2025 16:24:42 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 26/09/2025 16:24:30 26/09/2025 16:24:54 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 26/09/2025 07:26:50 26/09/2025 07:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/09/2025 07:26:51 25/09/2025 07:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/09/2025 10:04:43 24/09/2025 10:04:54 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 24/09/2025 10:04:43 24/09/2025 10:05:11 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 24/09/2025 09:59:09 24/09/2025 09:59:22 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 24/09/2025 09:59:09 24/09/2025 09:59:33 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 24/09/2025 07:26:54 24/09/2025 07:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/09/2025 07:26:55 23/09/2025 07:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/09/2025 21:52:28 22/09/2025 21:52:39 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/09/2025 21:52:28 22/09/2025 21:52:56 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/09/2025 11:33:59 22/09/2025 11:40:51 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/09/2025 11:33:59 22/09/2025 11:40:52 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/09/2025 08:37:49 22/09/2025 08:38:02 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/09/2025 08:37:49 22/09/2025 08:38:13 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/09/2025 08:01:33 22/09/2025 08:01:44 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 22/09/2025 07:26:56 22/09/2025 07:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/09/2025 15:05:20 21/09/2025 15:05:33 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/09/2025 15:05:20 21/09/2025 15:05:50 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/09/2025 10:32:03 21/09/2025 10:32:15 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/09/2025 10:32:03 21/09/2025 10:32:26 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/09/2025 10:03:24 21/09/2025 10:03:37 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/09/2025 10:03:24 21/09/2025 10:03:48 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 21/09/2025 07:26:57 21/09/2025 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/09/2025 11:37:41 20/09/2025 11:37:53 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 20/09/2025 11:37:41 20/09/2025 11:38:11 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 20/09/2025 10:11:47 20/09/2025 10:11:59 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 20/09/2025 10:11:47 20/09/2025 10:12:10 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 20/09/2025 09:38:04 20/09/2025 09:38:16 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 20/09/2025 09:38:04 20/09/2025 09:38:27 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 20/09/2025 09:30:51 20/09/2025 09:31:04 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 20/09/2025 09:30:51 20/09/2025 09:31:11 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 20/09/2025 07:26:59 20/09/2025 07:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/09/2025 11:03:22 19/09/2025 11:03:34 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 19/09/2025 11:03:22 19/09/2025 11:03:45 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 19/09/2025 07:27:00 19/09/2025 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/09/2025 07:27:02 18/09/2025 07:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/09/2025 07:27:04 17/09/2025 07:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/09/2025 06:26:53 16/09/2025 06:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/09/2025 06:26:54 15/09/2025 06:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/09/2025 06:26:56 14/09/2025 06:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/09/2025 06:26:57 13/09/2025 06:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/09/2025 17:19:29 12/09/2025 17:19:38 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/09/2025 17:19:29 12/09/2025 17:20:30 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/09/2025 06:26:59 12/09/2025 06:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/09/2025 06:27:01 11/09/2025 06:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/09/2025 06:27:02 10/09/2025 06:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/09/2025 10:57:00 09/09/2025 10:57:16 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/09/2025 10:57:00 09/09/2025 10:57:22 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/09/2025 10:57:00 09/09/2025 10:57:28 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/09/2025 10:57:00 09/09/2025 10:57:35 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/09/2025 10:56:27 09/09/2025 10:56:32 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/09/2025 10:56:02 09/09/2025 10:56:02 44139966 44139966 1,0 102 Temporary Fault Test Alarm
KRM_SERVER 09/09/2025 10:51:59 09/09/2025 10:52:35 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 09/09/2025 10:51:59 09/09/2025 10:52:41 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 09/09/2025 10:51:34 09/09/2025 10:51:44 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 09/09/2025 10:51:34 09/09/2025 10:51:50 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 09/09/2025 10:51:34 09/09/2025 10:52:52 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 09/09/2025 10:49:27 09/09/2025 10:49:59 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/09/2025 10:49:27 09/09/2025 10:50:15 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 09/09/2025 10:49:27 09/09/2025 10:52:12 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 09/09/2025 10:49:27 09/09/2025 10:53:20 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/09/2025 10:49:26 09/09/2025 10:49:47 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/09/2025 10:49:26 09/09/2025 10:50:27 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 09/09/2025 10:49:26 09/09/2025 10:53:15 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/09/2025 10:42:11 09/09/2025 10:43:03 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 09/09/2025 10:42:11 09/09/2025 10:43:27 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 09/09/2025 10:42:11 09/09/2025 10:46:43 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 09/09/2025 10:42:10 09/09/2025 10:42:20 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 09/09/2025 10:42:10 09/09/2025 10:42:28 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 09/09/2025 10:39:00 09/09/2025 10:40:15 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 09/09/2025 10:39:00 09/09/2025 10:47:31 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 09/09/2025 10:38:57 09/09/2025 10:39:11 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/09/2025 10:38:57 09/09/2025 10:39:17 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 09/09/2025 10:38:57 09/09/2025 10:39:34 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 09/09/2025 10:38:57 09/09/2025 10:39:58 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 09/09/2025 10:38:57 09/09/2025 10:40:03 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 09/09/2025 10:38:45 09/09/2025 10:39:00 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/09/2025 10:32:04 09/09/2025 10:32:51 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 09/09/2025 10:32:03 09/09/2025 10:32:57 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 09/09/2025 10:32:03 09/09/2025 10:39:45 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 09/09/2025 10:32:02 09/09/2025 10:33:08 44139966 44139966 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 09/09/2025 10:31:54 09/09/2025 10:32:28 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 08/09/2025 07:30:20 08/09/2025 07:30:44 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 08/09/2025 07:30:20 08/09/2025 07:30:50 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 08/09/2025 07:30:19 08/09/2025 07:30:33 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 08/09/2025 07:30:19 08/09/2025 07:30:38 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 08/09/2025 04:09:15 08/09/2025 04:09:30 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 08/09/2025 04:09:15 08/09/2025 04:09:43 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 08/09/2025 04:09:15 08/09/2025 04:09:55 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 08/09/2025 04:09:15 08/09/2025 04:10:07 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 08/09/2025 04:07:37 08/09/2025 04:07:52 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 08/09/2025 04:07:37 08/09/2025 04:07:59 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 08/09/2025 04:07:37 08/09/2025 04:08:05 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 08/09/2025 04:07:37 08/09/2025 04:10:19 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 08/09/2025 04:07:20 08/09/2025 04:08:11 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 08/09/2025 04:07:20 08/09/2025 04:09:48 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 08/09/2025 04:06:57 08/09/2025 04:08:16 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 08/09/2025 04:06:57 08/09/2025 04:08:27 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 08/09/2025 04:06:56 08/09/2025 04:08:33 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 08/09/2025 04:06:56 08/09/2025 04:08:45 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 08/09/2025 04:06:27 08/09/2025 04:07:35 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 08/09/2025 04:06:27 08/09/2025 04:08:51 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 08/09/2025 04:06:26 08/09/2025 04:07:30 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 08/09/2025 04:06:26 08/09/2025 04:09:02 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 08/09/2025 04:06:10 08/09/2025 04:06:59 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 08/09/2025 04:06:10 08/09/2025 04:07:11 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 08/09/2025 04:06:10 08/09/2025 04:07:24 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 08/09/2025 04:06:10 08/09/2025 04:10:24 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 08/09/2025 04:06:09 08/09/2025 04:06:46 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 08/09/2025 04:06:09 08/09/2025 04:06:53 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 08/09/2025 04:06:09 08/09/2025 04:07:17 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 08/09/2025 04:06:09 08/09/2025 04:07:46 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 08/09/2025 04:05:41 08/09/2025 04:05:46 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 08/09/2025 04:05:41 08/09/2025 04:05:58 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 08/09/2025 04:05:41 08/09/2025 04:09:09 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 08/09/2025 04:05:41 08/09/2025 04:09:14 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 08/09/2025 04:03:24 08/09/2025 04:03:34 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 08/09/2025 04:03:24 08/09/2025 04:03:40 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 08/09/2025 04:03:24 08/09/2025 04:06:04 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 08/09/2025 04:03:24 08/09/2025 04:06:16 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 08/09/2025 04:02:03 08/09/2025 04:02:08 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 08/09/2025 04:02:03 08/09/2025 04:02:14 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 08/09/2025 04:02:03 08/09/2025 04:07:41 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 08/09/2025 04:02:03 08/09/2025 04:09:19 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 08/09/2025 03:31:53 08/09/2025 03:31:53 44139966 44139966 1,0 100 Temporary Fault Unclassified Alarm
KRM_SERVER 08/09/2025 03:26:50 08/09/2025 03:26:50 44139966 44139966 1,0 100 Temporary Fault Unclassified Alarm
KRM_SERVER 08/09/2025 03:25:01 08/09/2025 03:25:14 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 08/09/2025 03:25:01 08/09/2025 04:06:35 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 08/09/2025 03:24:45 08/09/2025 03:24:56 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 08/09/2025 03:24:45 08/09/2025 03:25:09 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 07/09/2025 06:26:55 07/09/2025 06:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/09/2025 06:26:57 06/09/2025 06:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/09/2025 06:26:59 05/09/2025 06:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/09/2025 06:26:55 04/09/2025 06:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/09/2025 06:26:58 03/09/2025 06:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/09/2025 07:27:10 02/09/2025 07:27:16 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/09/2025 07:26:55 01/09/2025 07:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/08/2025 07:26:57 31/08/2025 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/08/2025 07:26:58 30/08/2025 07:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/08/2025 07:26:59 29/08/2025 07:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/08/2025 07:27:01 28/08/2025 07:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/08/2025 13:06:28 27/08/2025 14:07:11 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/08/2025 13:06:28 27/08/2025 14:07:43 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/08/2025 13:01:24 27/08/2025 14:02:04 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/08/2025 13:01:24 27/08/2025 14:03:10 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/08/2025 12:57:41 27/08/2025 13:58:20 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/08/2025 12:57:41 27/08/2025 13:59:31 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/08/2025 10:32:36 27/08/2025 11:33:16 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/08/2025 10:32:36 27/08/2025 11:34:40 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/08/2025 10:29:20 27/08/2025 11:30:00 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/08/2025 10:29:20 27/08/2025 11:30:27 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/08/2025 07:27:02 27/08/2025 07:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/08/2025 07:27:04 26/08/2025 07:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/08/2025 13:51:00 25/08/2025 14:51:40 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/08/2025 13:51:00 25/08/2025 14:52:45 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/08/2025 13:43:28 25/08/2025 14:44:08 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/08/2025 13:43:28 25/08/2025 14:49:14 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/08/2025 07:27:23 25/08/2025 07:27:28 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/08/2025 07:27:25 24/08/2025 07:27:30 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/08/2025 18:20:29 23/08/2025 19:21:09 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/08/2025 18:20:29 23/08/2025 19:21:23 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/08/2025 17:29:56 23/08/2025 18:30:36 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/08/2025 17:29:56 23/08/2025 18:31:27 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/08/2025 17:24:05 23/08/2025 18:24:45 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/08/2025 17:24:05 23/08/2025 18:26:31 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/08/2025 13:19:12 23/08/2025 14:19:53 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/08/2025 13:19:12 23/08/2025 14:19:58 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/08/2025 07:27:26 23/08/2025 07:27:31 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/08/2025 07:27:28 22/08/2025 07:27:33 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/08/2025 13:03:45 21/08/2025 14:04:27 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/08/2025 13:03:45 21/08/2025 14:04:37 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/08/2025 07:27:29 21/08/2025 07:27:34 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/08/2025 07:27:31 20/08/2025 07:27:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/08/2025 07:27:32 19/08/2025 07:27:37 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/08/2025 07:27:34 18/08/2025 07:27:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/08/2025 07:27:35 17/08/2025 07:27:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/08/2025 20:32:22 16/08/2025 20:32:22 44139966 44139966 1,0 100 Temporary Fault Unclassified Alarm
KRM_SERVER 16/08/2025 07:27:37 16/08/2025 07:27:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/08/2025 07:27:38 15/08/2025 07:27:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/08/2025 13:51:07 14/08/2025 12:52:02 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 14/08/2025 13:50:42 14/08/2025 12:51:47 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 14/08/2025 13:50:38 14/08/2025 12:51:33 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 14/08/2025 13:44:29 14/08/2025 12:45:24 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 14/08/2025 08:26:06 14/08/2025 07:26:23 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 14/08/2025 08:26:04 14/08/2025 07:26:11 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 14/08/2025 08:25:42 14/08/2025 07:26:37 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 14/08/2025 08:24:00 14/08/2025 07:24:07 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 14/08/2025 07:27:39 14/08/2025 07:27:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/08/2025 07:26:49 14/08/2025 07:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/08/2025 07:26:52 13/08/2025 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/08/2025 07:26:53 12/08/2025 07:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/08/2025 18:51:26 11/08/2025 19:51:47 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/08/2025 18:51:26 11/08/2025 19:55:28 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/08/2025 07:26:55 11/08/2025 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/08/2025 07:26:56 10/08/2025 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/08/2025 07:26:57 09/08/2025 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/08/2025 07:26:59 08/08/2025 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/08/2025 07:27:00 07/08/2025 07:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/08/2025 07:27:01 06/08/2025 07:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/08/2025 07:27:03 05/08/2025 07:27:11 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/08/2025 17:07:24 04/08/2025 18:07:46 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 04/08/2025 17:07:24 04/08/2025 18:08:40 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 04/08/2025 07:29:12 04/08/2025 07:29:19 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/08/2025 07:29:12 03/08/2025 07:29:19 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/08/2025 08:59:37 02/08/2025 10:00:00 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/08/2025 08:59:37 02/08/2025 10:00:11 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/08/2025 07:29:14 02/08/2025 07:29:22 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/08/2025 09:02:00 01/08/2025 10:02:23 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 01/08/2025 09:02:00 01/08/2025 10:03:33 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 01/08/2025 07:29:16 01/08/2025 07:29:24 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/07/2025 07:29:17 31/07/2025 07:29:24 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/07/2025 07:29:20 30/07/2025 07:29:27 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/07/2025 08:02:46 29/07/2025 09:03:11 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 29/07/2025 08:02:46 29/07/2025 09:03:52 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 29/07/2025 07:29:21 29/07/2025 07:29:27 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/07/2025 07:29:22 28/07/2025 07:29:29 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/07/2025 07:29:24 27/07/2025 07:29:30 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/07/2025 07:29:24 26/07/2025 07:29:30 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/07/2025 07:34:41 25/07/2025 08:35:07 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/07/2025 07:34:41 25/07/2025 08:35:52 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/07/2025 07:29:26 25/07/2025 07:29:33 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/07/2025 01:32:05 25/07/2025 01:32:12 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/07/2025 07:29:28 24/07/2025 07:29:34 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/07/2025 07:29:29 23/07/2025 07:29:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/07/2025 07:26:52 23/07/2025 07:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/07/2025 05:56:03 23/07/2025 04:53:55 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 23/07/2025 05:55:59 23/07/2025 04:53:50 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 23/07/2025 05:54:16 23/07/2025 04:52:07 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 23/07/2025 05:53:51 23/07/2025 04:54:21 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 22/07/2025 09:19:32 22/07/2025 10:25:43 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 22/07/2025 09:19:32 22/07/2025 10:25:49 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 22/07/2025 07:26:53 22/07/2025 07:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/07/2025 09:32:45 21/07/2025 10:32:00 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 21/07/2025 09:32:45 21/07/2025 10:32:06 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 21/07/2025 07:26:55 21/07/2025 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/07/2025 07:26:57 20/07/2025 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/07/2025 07:26:58 19/07/2025 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/07/2025 07:27:00 18/07/2025 07:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/07/2025 07:27:00 17/07/2025 07:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/07/2025 07:27:02 16/07/2025 07:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/07/2025 07:27:03 15/07/2025 07:27:10 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/07/2025 07:26:35 14/07/2025 07:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/07/2025 07:26:37 13/07/2025 07:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/07/2025 07:26:37 12/07/2025 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/07/2025 07:26:39 11/07/2025 07:26:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/07/2025 07:26:41 10/07/2025 07:26:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/07/2025 07:26:42 09/07/2025 07:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/07/2025 07:26:44 08/07/2025 07:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/07/2025 07:26:45 07/07/2025 07:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/07/2025 07:26:46 06/07/2025 07:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/07/2025 07:26:48 05/07/2025 07:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/07/2025 07:26:50 04/07/2025 07:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/07/2025 07:26:51 03/07/2025 07:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/07/2025 07:26:53 02/07/2025 07:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/07/2025 07:26:54 01/07/2025 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/06/2025 07:26:55 30/06/2025 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/06/2025 07:26:57 29/06/2025 07:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/06/2025 07:26:58 28/06/2025 07:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/06/2025 11:13:40 27/06/2025 12:13:02 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/06/2025 07:26:59 27/06/2025 07:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/06/2025 10:33:00 26/06/2025 11:32:22 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 26/06/2025 10:33:00 26/06/2025 11:32:49 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 26/06/2025 07:27:01 26/06/2025 07:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/06/2025 07:27:02 25/06/2025 07:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/06/2025 07:27:03 24/06/2025 07:27:11 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/06/2025 07:26:34 23/06/2025 07:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/06/2025 14:53:46 22/06/2025 15:53:08 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 22/06/2025 14:53:46 22/06/2025 15:53:25 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 22/06/2025 07:26:36 22/06/2025 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/06/2025 07:26:38 21/06/2025 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/06/2025 07:26:39 20/06/2025 07:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/06/2025 05:02:14 20/06/2025 06:01:38 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/06/2025 05:02:14 20/06/2025 06:03:04 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/06/2025 04:58:37 20/06/2025 05:58:01 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/06/2025 04:58:37 20/06/2025 05:58:06 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/06/2025 07:26:41 18/06/2025 07:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/06/2025 07:26:43 17/06/2025 07:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/06/2025 07:26:44 16/06/2025 07:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/06/2025 07:26:46 15/06/2025 07:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/06/2025 07:26:47 14/06/2025 07:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/06/2025 07:26:48 13/06/2025 07:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/06/2025 07:26:49 12/06/2025 07:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/06/2025 07:26:52 11/06/2025 07:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/06/2025 07:26:53 10/06/2025 07:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/06/2025 07:26:54 09/06/2025 07:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/06/2025 07:26:56 08/06/2025 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/06/2025 07:26:57 07/06/2025 07:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/06/2025 07:26:59 06/06/2025 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/06/2025 07:27:01 05/06/2025 07:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/06/2025 07:27:02 04/06/2025 07:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/06/2025 07:27:04 03/06/2025 07:27:12 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/06/2025 07:26:33 02/06/2025 07:26:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/06/2025 07:26:34 01/06/2025 07:26:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/05/2025 07:26:36 31/05/2025 07:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/05/2025 07:26:37 30/05/2025 07:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/05/2025 07:26:39 29/05/2025 07:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/05/2025 07:26:40 28/05/2025 07:26:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/05/2025 07:26:42 27/05/2025 07:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/05/2025 07:26:43 26/05/2025 07:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/05/2025 07:26:45 25/05/2025 07:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/05/2025 07:26:46 24/05/2025 07:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/05/2025 07:26:47 23/05/2025 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/05/2025 07:26:50 22/05/2025 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/05/2025 07:26:51 21/05/2025 07:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/05/2025 07:26:53 20/05/2025 07:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/05/2025 07:26:54 19/05/2025 07:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/05/2025 07:26:56 18/05/2025 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/05/2025 07:26:57 17/05/2025 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/05/2025 07:26:58 16/05/2025 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/05/2025 07:27:00 15/05/2025 07:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/05/2025 07:27:02 14/05/2025 07:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/05/2025 05:47:08 14/05/2025 05:47:15 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/05/2025 07:27:03 13/05/2025 07:27:12 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/05/2025 07:27:58 12/05/2025 07:28:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/05/2025 07:28:00 11/05/2025 07:28:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/05/2025 07:28:02 10/05/2025 07:28:10 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/05/2025 07:26:35 10/05/2025 07:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/05/2025 23:21:41 09/05/2025 22:19:53 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 09/05/2025 23:20:35 09/05/2025 22:20:13 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 09/05/2025 07:26:37 09/05/2025 07:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/05/2025 07:26:38 08/05/2025 07:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/05/2025 07:26:40 07/05/2025 07:33:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/05/2025 07:26:41 06/05/2025 07:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/05/2025 07:26:48 05/05/2025 07:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/05/2025 07:26:45 04/05/2025 07:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/05/2025 07:26:46 03/05/2025 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/05/2025 07:26:47 02/05/2025 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/05/2025 07:26:54 01/05/2025 07:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/04/2025 07:26:50 30/04/2025 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/04/2025 07:26:52 29/04/2025 07:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/04/2025 07:26:54 28/04/2025 07:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/04/2025 07:26:54 27/04/2025 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/04/2025 07:26:56 26/04/2025 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/04/2025 07:26:58 25/04/2025 07:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/04/2025 12:54:05 24/04/2025 13:53:38 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/04/2025 12:54:05 24/04/2025 13:53:43 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/04/2025 12:54:05 24/04/2025 13:56:47 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/04/2025 12:54:05 24/04/2025 13:56:53 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 24/04/2025 07:27:00 24/04/2025 07:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/04/2025 07:28:16 23/04/2025 07:28:24 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/04/2025 07:27:03 22/04/2025 07:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/04/2025 11:42:03 21/04/2025 12:41:26 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/04/2025 11:42:03 21/04/2025 12:44:04 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/04/2025 07:26:33 21/04/2025 07:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/04/2025 07:26:34 20/04/2025 07:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/04/2025 07:26:36 19/04/2025 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/04/2025 07:26:38 18/04/2025 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/04/2025 07:26:39 17/04/2025 07:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/04/2025 07:26:41 16/04/2025 07:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/04/2025 07:26:42 15/04/2025 07:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/04/2025 07:26:44 14/04/2025 07:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/04/2025 07:26:45 13/04/2025 07:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/04/2025 07:26:46 12/04/2025 07:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/04/2025 07:26:48 11/04/2025 07:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/04/2025 07:26:50 10/04/2025 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/04/2025 07:26:51 09/04/2025 07:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/04/2025 07:26:53 08/04/2025 07:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/04/2025 07:26:55 07/04/2025 07:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/04/2025 07:26:56 06/04/2025 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/04/2025 07:26:57 05/04/2025 07:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/04/2025 07:26:59 04/04/2025 07:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/04/2025 07:27:00 03/04/2025 07:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/04/2025 07:27:02 02/04/2025 07:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/04/2025 07:27:04 01/04/2025 07:27:10 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/03/2025 07:27:45 31/03/2025 07:27:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/03/2025 06:27:45 30/03/2025 06:27:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/03/2025 06:27:47 29/03/2025 06:27:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/03/2025 06:27:48 28/03/2025 06:27:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/03/2025 06:27:50 27/03/2025 06:27:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/03/2025 06:27:52 26/03/2025 06:28:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/03/2025 06:27:53 25/03/2025 06:28:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/03/2025 06:27:55 24/03/2025 06:28:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/03/2025 06:27:56 23/03/2025 06:28:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/03/2025 06:27:58 22/03/2025 06:28:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/03/2025 06:27:59 21/03/2025 06:28:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/03/2025 15:41:45 20/03/2025 15:41:45 44139966 44139966 1,0 100 Temporary Fault Unclassified Alarm
KRM_SERVER 20/03/2025 06:28:01 20/03/2025 06:28:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/03/2025 06:28:02 19/03/2025 06:28:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/03/2025 06:28:03 18/03/2025 06:28:10 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/03/2025 06:28:06 17/03/2025 06:28:13 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/03/2025 06:28:07 16/03/2025 06:28:16 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/03/2025 06:28:09 15/03/2025 06:28:16 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/03/2025 06:26:57 15/03/2025 06:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/03/2025 18:14:12 14/03/2025 18:13:56 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 14/03/2025 18:14:12 14/03/2025 18:14:35 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 14/03/2025 18:14:11 14/03/2025 18:13:50 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 14/03/2025 18:14:11 14/03/2025 18:14:41 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 14/03/2025 18:13:03 14/03/2025 18:13:23 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 14/03/2025 18:13:03 14/03/2025 18:14:20 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 14/03/2025 18:13:02 14/03/2025 18:13:17 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 14/03/2025 18:13:02 14/03/2025 18:14:14 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 14/03/2025 18:12:56 14/03/2025 18:12:59 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 18:12:56 14/03/2025 18:13:06 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 14/03/2025 18:12:56 14/03/2025 18:13:34 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 14/03/2025 18:12:56 14/03/2025 18:15:11 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 18:12:55 14/03/2025 18:12:35 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 18:12:55 14/03/2025 18:12:41 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 14/03/2025 18:12:55 14/03/2025 18:13:28 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 14/03/2025 18:12:55 14/03/2025 18:15:05 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 18:07:21 14/03/2025 18:07:13 44139966 44139966 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 14/03/2025 18:07:21 14/03/2025 18:07:30 44139966 44139966 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 14/03/2025 17:55:41 14/03/2025 17:56:13 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 14/03/2025 17:55:41 14/03/2025 17:56:19 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 14/03/2025 17:55:41 14/03/2025 17:58:08 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 14/03/2025 17:55:41 14/03/2025 17:58:13 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 14/03/2025 17:54:59 14/03/2025 17:55:39 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 14/03/2025 17:54:59 14/03/2025 17:55:45 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 14/03/2025 17:54:59 14/03/2025 17:55:56 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 14/03/2025 17:54:59 14/03/2025 17:56:31 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 14/03/2025 17:54:58 14/03/2025 17:54:37 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:54:58 14/03/2025 17:54:43 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 14/03/2025 17:54:58 14/03/2025 17:54:48 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 14/03/2025 17:54:58 14/03/2025 17:54:54 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 14/03/2025 17:54:58 14/03/2025 17:55:05 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:54:58 14/03/2025 17:55:11 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 14/03/2025 17:54:58 14/03/2025 17:55:22 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 14/03/2025 17:54:58 14/03/2025 17:55:33 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 14/03/2025 17:54:58 14/03/2025 17:55:50 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 14/03/2025 17:54:58 14/03/2025 17:56:37 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 14/03/2025 17:54:58 14/03/2025 18:12:53 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:54:58 14/03/2025 18:13:12 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:54:44 14/03/2025 17:54:23 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:54:44 14/03/2025 17:54:29 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:54:44 14/03/2025 17:55:00 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:54:44 14/03/2025 17:55:16 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:44:27 14/03/2025 17:44:06 44139966 44139966 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 14/03/2025 17:44:27 14/03/2025 17:44:12 44139966 44139966 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 14/03/2025 17:44:27 14/03/2025 17:44:24 44139966 44139966 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 14/03/2025 17:44:27 14/03/2025 17:44:30 44139966 44139966 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 14/03/2025 17:44:27 14/03/2025 17:44:37 44139966 44139966 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 14/03/2025 17:44:27 14/03/2025 17:44:42 44139966 44139966 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 14/03/2025 17:44:27 14/03/2025 17:44:48 44139966 44139966 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 14/03/2025 17:44:27 14/03/2025 17:44:53 44139966 44139966 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 14/03/2025 17:36:12 14/03/2025 17:36:01 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 14/03/2025 17:36:12 14/03/2025 17:36:06 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 14/03/2025 17:36:12 14/03/2025 17:36:12 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 14/03/2025 17:36:12 14/03/2025 17:36:17 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 14/03/2025 17:35:31 14/03/2025 17:35:10 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 14/03/2025 17:35:31 14/03/2025 17:35:17 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 14/03/2025 17:35:31 14/03/2025 17:36:29 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 14/03/2025 17:35:31 14/03/2025 17:36:34 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 14/03/2025 17:33:19 14/03/2025 17:33:03 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:33:19 14/03/2025 17:33:09 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 14/03/2025 17:33:19 14/03/2025 17:33:20 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 14/03/2025 17:33:19 14/03/2025 17:33:25 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:33:19 14/03/2025 17:33:31 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 14/03/2025 17:33:19 14/03/2025 17:33:38 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 14/03/2025 17:33:19 14/03/2025 17:33:44 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 14/03/2025 17:33:19 14/03/2025 17:33:49 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 14/03/2025 17:33:19 14/03/2025 17:35:50 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 14/03/2025 17:33:19 14/03/2025 17:35:55 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 14/03/2025 17:33:19 14/03/2025 17:36:53 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:33:19 14/03/2025 17:36:59 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:13:59 14/03/2025 17:13:38 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 14/03/2025 17:13:59 14/03/2025 17:13:45 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 14/03/2025 17:13:59 14/03/2025 17:15:26 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 14/03/2025 17:13:59 14/03/2025 17:15:32 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 14/03/2025 17:04:15 14/03/2025 17:04:38 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 14/03/2025 17:04:15 14/03/2025 17:14:51 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 14/03/2025 17:04:12 14/03/2025 17:04:27 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 14/03/2025 17:04:12 14/03/2025 17:04:45 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 14/03/2025 17:04:11 14/03/2025 17:04:21 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 14/03/2025 17:04:11 14/03/2025 17:04:51 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 14/03/2025 17:02:55 14/03/2025 17:02:47 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:02:55 14/03/2025 17:02:52 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 14/03/2025 17:02:55 14/03/2025 17:02:58 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 14/03/2025 17:02:55 14/03/2025 17:03:03 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 14/03/2025 17:02:55 14/03/2025 17:03:16 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 14/03/2025 17:02:55 14/03/2025 17:03:22 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:02:55 14/03/2025 17:03:27 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 14/03/2025 17:02:55 14/03/2025 17:03:34 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 14/03/2025 17:02:55 14/03/2025 17:03:41 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 14/03/2025 17:02:55 14/03/2025 17:03:59 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 14/03/2025 17:02:55 14/03/2025 17:04:05 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 14/03/2025 17:02:55 14/03/2025 17:04:10 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 14/03/2025 17:02:55 14/03/2025 17:04:32 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 14/03/2025 17:02:55 14/03/2025 17:14:56 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 14/03/2025 17:02:55 14/03/2025 17:33:14 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:02:55 14/03/2025 17:33:55 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:00:10 14/03/2025 16:59:49 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:00:10 14/03/2025 16:59:55 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:00:10 14/03/2025 17:03:11 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 17:00:10 14/03/2025 17:03:46 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 14/03/2025 15:02:21 14/03/2025 14:02:20 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 14/03/2025 15:02:16 14/03/2025 14:02:07 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 14/03/2025 14:56:23 14/03/2025 13:55:03 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 14/03/2025 14:55:46 14/03/2025 13:55:37 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 14/03/2025 14:02:19 14/03/2025 14:02:02 44139966 44139966 1,0 1037 Elevator Failure Car door: stuck contact
KRM_SERVER 14/03/2025 14:02:19 14/03/2025 17:03:52 44139966 44139966 1,0 1037 Elevator Failure Car door: stuck contact
KRM_SERVER 14/03/2025 14:02:13 14/03/2025 14:02:07 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/03/2025 14:02:13 14/03/2025 17:02:33 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/03/2025 13:55:31 14/03/2025 13:55:20 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/03/2025 13:45:32 14/03/2025 13:45:06 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/03/2025 13:45:16 14/03/2025 13:45:01 44139966 44139966 1,0 1614 Elevator Failure Car door close end limit stuck
KRM_SERVER 14/03/2025 06:26:58 14/03/2025 06:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/03/2025 06:27:00 13/03/2025 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/03/2025 06:27:01 12/03/2025 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/03/2025 17:09:29 11/03/2025 17:08:55 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/03/2025 17:09:29 11/03/2025 17:09:56 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/03/2025 11:01:41 11/03/2025 11:01:08 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/03/2025 11:01:41 11/03/2025 11:01:30 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/03/2025 06:27:03 11/03/2025 06:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/03/2025 06:26:31 10/03/2025 06:26:38 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/03/2025 06:26:34 09/03/2025 06:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/03/2025 06:26:35 08/03/2025 06:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/03/2025 06:26:37 07/03/2025 06:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/03/2025 13:35:23 06/03/2025 13:34:52 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/03/2025 13:35:23 06/03/2025 13:39:02 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/03/2025 06:26:38 06/03/2025 06:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/03/2025 11:53:17 05/03/2025 11:52:47 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 05/03/2025 11:53:17 05/03/2025 12:02:30 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 05/03/2025 06:26:40 05/03/2025 06:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/03/2025 06:26:41 04/03/2025 06:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/03/2025 06:26:43 03/03/2025 06:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/03/2025 22:39:45 02/03/2025 22:39:16 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/03/2025 22:39:45 02/03/2025 22:44:25 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/03/2025 14:14:39 02/03/2025 14:14:10 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/03/2025 14:14:39 02/03/2025 14:15:43 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/03/2025 12:33:34 02/03/2025 12:33:05 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/03/2025 12:33:34 02/03/2025 12:40:07 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/03/2025 06:26:44 02/03/2025 06:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/03/2025 16:45:33 01/03/2025 16:45:04 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 01/03/2025 16:45:33 01/03/2025 16:47:28 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 01/03/2025 06:26:47 01/03/2025 06:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/02/2025 10:30:50 28/02/2025 10:30:22 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 28/02/2025 10:30:50 28/02/2025 10:33:03 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 28/02/2025 07:34:57 28/02/2025 07:34:29 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 28/02/2025 07:34:57 28/02/2025 07:36:49 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 28/02/2025 06:26:47 28/02/2025 06:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/02/2025 06:26:49 27/02/2025 06:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/02/2025 06:26:50 26/02/2025 06:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/02/2025 06:26:52 25/02/2025 06:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/02/2025 06:26:54 24/02/2025 06:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/02/2025 06:26:54 23/02/2025 06:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/02/2025 06:26:56 22/02/2025 06:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/02/2025 06:26:58 21/02/2025 06:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/02/2025 06:27:00 20/02/2025 06:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/02/2025 06:27:01 19/02/2025 06:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/02/2025 06:27:03 18/02/2025 06:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/02/2025 06:26:30 17/02/2025 06:26:37 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/02/2025 06:26:32 16/02/2025 06:26:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/02/2025 06:26:34 15/02/2025 06:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/02/2025 06:26:36 14/02/2025 06:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/02/2025 06:26:36 13/02/2025 06:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/02/2025 06:26:38 12/02/2025 06:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/02/2025 06:26:40 11/02/2025 06:26:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/02/2025 06:26:42 10/02/2025 06:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/02/2025 06:26:43 09/02/2025 06:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/02/2025 06:26:45 08/02/2025 06:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/02/2025 06:26:46 07/02/2025 06:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/02/2025 06:26:50 06/02/2025 06:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/02/2025 06:26:49 05/02/2025 06:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/02/2025 15:44:53 04/02/2025 15:44:36 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 04/02/2025 15:44:53 04/02/2025 15:44:41 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 04/02/2025 15:44:53 04/02/2025 15:44:47 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 04/02/2025 15:44:53 04/02/2025 15:44:53 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 04/02/2025 15:44:53 04/02/2025 15:44:58 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 04/02/2025 15:44:53 04/02/2025 15:45:05 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 04/02/2025 15:44:53 04/02/2025 15:45:15 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 04/02/2025 15:44:53 04/02/2025 15:45:21 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 04/02/2025 15:44:53 04/02/2025 15:45:26 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 04/02/2025 15:44:53 04/02/2025 15:45:32 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 04/02/2025 15:44:53 04/02/2025 15:45:37 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 04/02/2025 15:44:53 04/02/2025 15:45:42 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 04/02/2025 06:26:51 04/02/2025 06:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/02/2025 06:26:53 03/02/2025 06:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/02/2025 06:26:55 02/02/2025 06:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/02/2025 06:26:55 01/02/2025 06:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/01/2025 11:36:16 31/01/2025 11:36:01 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 31/01/2025 11:36:16 31/01/2025 11:37:04 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 31/01/2025 10:54:20 31/01/2025 10:54:04 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 31/01/2025 10:54:20 31/01/2025 10:55:16 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 31/01/2025 06:26:57 31/01/2025 06:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/01/2025 06:26:59 30/01/2025 06:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/01/2025 06:27:00 29/01/2025 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/01/2025 06:27:02 28/01/2025 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/01/2025 23:21:21 27/01/2025 23:21:07 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 27/01/2025 23:21:21 27/01/2025 23:21:12 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 27/01/2025 07:26:46 27/01/2025 07:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/01/2025 07:26:48 26/01/2025 07:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/01/2025 07:26:50 25/01/2025 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/01/2025 07:26:52 24/01/2025 07:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/01/2025 07:26:53 23/01/2025 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/01/2025 07:26:54 22/01/2025 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/01/2025 06:26:38 22/01/2025 06:50:12 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/01/2025 21:00:25 21/01/2025 19:00:14 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/01/2025 21:00:15 21/01/2025 19:00:00 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 21/01/2025 21:00:01 21/01/2025 18:59:46 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 21/01/2025 20:00:28 21/01/2025 19:00:30 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/01/2025 06:26:40 21/01/2025 06:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/01/2025 06:26:41 20/01/2025 06:43:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/01/2025 06:26:43 19/01/2025 06:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/01/2025 10:51:27 18/01/2025 10:51:03 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/01/2025 10:51:27 18/01/2025 10:52:12 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/01/2025 10:36:13 18/01/2025 10:35:49 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/01/2025 10:36:13 18/01/2025 10:37:16 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/01/2025 06:26:45 18/01/2025 06:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/01/2025 06:26:46 17/01/2025 06:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/01/2025 06:26:48 16/01/2025 06:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/01/2025 06:26:50 15/01/2025 06:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/01/2025 06:26:52 14/01/2025 06:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/01/2025 06:26:53 13/01/2025 06:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/01/2025 06:26:55 12/01/2025 06:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/01/2025 17:22:48 11/01/2025 17:22:27 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/01/2025 17:22:48 11/01/2025 17:22:33 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/01/2025 06:26:56 11/01/2025 06:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/01/2025 06:26:58 10/01/2025 06:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/01/2025 06:27:00 09/01/2025 06:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/01/2025 10:58:38 08/01/2025 10:58:24 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 08/01/2025 10:58:38 08/01/2025 10:58:29 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 08/01/2025 10:58:38 08/01/2025 10:58:36 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 08/01/2025 10:58:38 08/01/2025 10:58:42 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 08/01/2025 06:27:01 08/01/2025 06:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/01/2025 06:27:03 07/01/2025 06:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/01/2025 06:26:30 06/01/2025 06:26:37 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/01/2025 06:26:31 05/01/2025 06:26:38 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/01/2025 06:26:33 04/01/2025 06:26:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/01/2025 06:26:35 03/01/2025 06:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/01/2025 06:26:36 02/01/2025 06:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/01/2025 06:26:38 01/01/2025 06:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/12/2024 18:29:42 31/12/2024 18:29:26 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 31/12/2024 18:29:42 31/12/2024 18:30:16 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 31/12/2024 06:26:39 31/12/2024 06:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/12/2024 06:26:41 30/12/2024 06:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/12/2024 06:26:43 29/12/2024 06:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/12/2024 13:42:37 28/12/2024 13:42:23 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 28/12/2024 13:42:37 28/12/2024 13:44:03 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 28/12/2024 13:37:27 28/12/2024 13:37:13 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 28/12/2024 13:37:27 28/12/2024 13:39:51 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 28/12/2024 06:26:44 28/12/2024 06:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/12/2024 06:26:46 27/12/2024 06:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/12/2024 06:26:48 26/12/2024 06:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/12/2024 06:26:49 25/12/2024 06:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/12/2024 06:26:56 24/12/2024 06:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/12/2024 06:26:52 23/12/2024 06:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/12/2024 06:26:54 22/12/2024 06:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/12/2024 06:26:56 21/12/2024 06:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/12/2024 17:51:56 20/12/2024 17:51:45 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/12/2024 17:51:56 20/12/2024 17:51:57 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/12/2024 06:26:57 20/12/2024 06:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/12/2024 06:26:59 19/12/2024 06:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/12/2024 16:24:30 18/12/2024 16:24:21 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/12/2024 16:24:30 18/12/2024 16:24:26 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/12/2024 16:24:30 18/12/2024 16:24:32 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/12/2024 16:24:30 18/12/2024 16:24:37 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/12/2024 16:24:30 18/12/2024 16:24:42 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/12/2024 16:24:30 18/12/2024 16:24:48 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/12/2024 16:24:30 18/12/2024 16:25:22 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/12/2024 16:24:30 18/12/2024 16:25:27 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/12/2024 16:24:30 18/12/2024 16:25:32 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/12/2024 16:24:30 18/12/2024 16:25:38 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/12/2024 16:24:30 18/12/2024 16:25:43 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/12/2024 16:24:30 18/12/2024 16:25:49 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/12/2024 06:27:01 18/12/2024 06:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/12/2024 06:27:02 17/12/2024 06:27:11 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/12/2024 06:27:04 16/12/2024 06:27:11 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/12/2024 06:26:32 15/12/2024 06:26:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/12/2024 06:26:34 14/12/2024 06:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/12/2024 06:26:36 13/12/2024 06:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/12/2024 06:26:37 12/12/2024 06:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/12/2024 06:26:38 11/12/2024 06:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/12/2024 06:26:40 10/12/2024 06:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/12/2024 06:26:48 05/12/2024 06:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/12/2024 06:26:50 04/12/2024 06:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/12/2024 06:26:51 03/12/2024 07:45:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/12/2024 14:19:52 02/12/2024 14:19:55 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 02/12/2024 14:19:52 02/12/2024 14:20:01 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 02/12/2024 14:19:52 02/12/2024 14:20:06 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 02/12/2024 14:19:52 02/12/2024 14:20:11 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 02/12/2024 14:12:40 02/12/2024 14:12:44 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 02/12/2024 14:12:40 02/12/2024 14:18:51 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 02/12/2024 14:12:39 02/12/2024 14:12:37 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 02/12/2024 14:12:39 02/12/2024 14:18:45 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 02/12/2024 14:02:29 02/12/2024 14:02:29 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 02/12/2024 14:02:29 02/12/2024 14:02:34 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 02/12/2024 14:02:29 02/12/2024 14:02:39 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 02/12/2024 14:02:29 02/12/2024 14:02:45 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 02/12/2024 14:02:29 02/12/2024 14:02:50 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 02/12/2024 14:02:29 02/12/2024 14:02:56 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 02/12/2024 14:02:29 02/12/2024 14:03:01 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 02/12/2024 14:02:29 02/12/2024 14:03:08 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 02/12/2024 14:01:41 02/12/2024 14:02:12 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 02/12/2024 14:01:41 02/12/2024 14:02:17 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 02/12/2024 14:01:41 02/12/2024 14:03:19 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 02/12/2024 14:01:41 02/12/2024 14:03:24 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 02/12/2024 14:01:20 02/12/2024 14:01:35 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 02/12/2024 14:01:20 02/12/2024 14:01:40 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 02/12/2024 14:01:20 02/12/2024 14:01:48 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 02/12/2024 14:01:20 02/12/2024 14:01:53 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 02/12/2024 14:00:45 02/12/2024 14:03:30 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 02/12/2024 14:00:45 02/12/2024 14:03:35 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 02/12/2024 14:00:45 02/12/2024 14:03:40 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 02/12/2024 14:00:45 02/12/2024 14:03:46 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 02/12/2024 14:00:10 02/12/2024 14:00:17 44139966 44139966 1,0 1181 Elevator Failure Door bypass switch misuse
KRM_SERVER 02/12/2024 14:00:10 02/12/2024 14:00:39 44139966 44139966 1,0 1181 Elevator Failure Door bypass switch misuse
KRM_SERVER 02/12/2024 14:00:08 02/12/2024 14:00:12 44139966 44139966 1,0 1181 Elevator Failure Door bypass switch misuse
KRM_SERVER 02/12/2024 14:00:08 02/12/2024 14:00:33 44139966 44139966 1,0 1181 Elevator Failure Door bypass switch misuse
KRM_SERVER 02/12/2024 13:59:23 02/12/2024 13:59:21 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 02/12/2024 13:59:23 02/12/2024 13:59:33 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 02/12/2024 13:59:23 02/12/2024 13:59:39 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 02/12/2024 13:59:23 02/12/2024 13:59:44 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 02/12/2024 13:59:23 02/12/2024 13:59:50 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 02/12/2024 13:59:23 02/12/2024 13:59:55 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 02/12/2024 13:59:23 02/12/2024 14:00:57 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 02/12/2024 13:59:23 02/12/2024 14:01:02 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 02/12/2024 13:59:23 02/12/2024 14:01:08 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 02/12/2024 13:59:23 02/12/2024 14:01:14 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 02/12/2024 13:59:23 02/12/2024 14:01:19 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 02/12/2024 13:59:23 02/12/2024 14:03:51 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 02/12/2024 13:35:30 02/12/2024 13:35:38 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 02/12/2024 13:35:30 02/12/2024 13:36:13 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 02/12/2024 13:35:29 02/12/2024 13:35:33 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 02/12/2024 13:35:29 02/12/2024 13:36:08 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 02/12/2024 13:31:14 02/12/2024 13:31:18 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 02/12/2024 13:31:14 02/12/2024 13:31:25 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 02/12/2024 13:31:14 02/12/2024 13:35:00 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 02/12/2024 13:31:14 02/12/2024 13:35:12 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 02/12/2024 06:26:53 02/12/2024 06:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/12/2024 06:26:54 01/12/2024 06:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/11/2024 06:26:57 30/11/2024 06:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/11/2024 06:26:57 29/11/2024 06:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/11/2024 06:26:59 28/11/2024 06:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/11/2024 06:27:07 27/11/2024 06:27:13 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/11/2024 07:27:02 26/11/2024 07:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/11/2024 06:27:02 26/11/2024 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/11/2024 07:27:04 25/11/2024 07:27:11 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/11/2024 06:27:04 25/11/2024 06:27:11 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/11/2024 08:26:47 24/11/2024 08:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/11/2024 07:26:47 24/11/2024 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/11/2024 06:26:47 24/11/2024 06:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/11/2024 08:26:49 23/11/2024 08:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/11/2024 07:26:49 23/11/2024 07:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/11/2024 06:26:49 23/11/2024 06:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/11/2024 08:26:50 22/11/2024 08:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/11/2024 07:26:50 22/11/2024 07:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/11/2024 06:26:50 22/11/2024 06:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/11/2024 08:26:52 21/11/2024 08:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/11/2024 07:26:52 21/11/2024 07:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/11/2024 06:26:52 21/11/2024 06:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/11/2024 08:26:54 20/11/2024 08:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/11/2024 07:26:54 20/11/2024 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/11/2024 06:26:54 20/11/2024 06:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/11/2024 08:26:56 19/11/2024 08:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/11/2024 07:26:56 19/11/2024 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/11/2024 06:26:56 19/11/2024 06:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/11/2024 08:26:56 18/11/2024 08:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/11/2024 07:26:56 18/11/2024 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/11/2024 06:26:56 18/11/2024 06:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/11/2024 08:26:58 17/11/2024 08:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/11/2024 07:26:58 17/11/2024 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/11/2024 06:26:58 17/11/2024 06:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/11/2024 08:27:00 16/11/2024 08:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/11/2024 07:27:00 16/11/2024 07:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/11/2024 06:27:00 16/11/2024 06:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/11/2024 08:27:02 15/11/2024 08:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/11/2024 07:27:02 15/11/2024 07:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/11/2024 06:27:02 15/11/2024 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/11/2024 06:27:08 14/11/2024 06:27:15 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/11/2024 06:27:04 13/11/2024 06:27:11 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/11/2024 06:27:06 12/11/2024 06:27:13 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/11/2024 06:27:08 11/11/2024 06:27:14 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/11/2024 06:27:09 10/11/2024 06:27:16 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/11/2024 06:27:11 09/11/2024 06:27:18 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/11/2024 06:27:12 08/11/2024 06:27:18 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/11/2024 06:27:13 07/11/2024 06:27:20 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/11/2024 18:11:14 06/11/2024 17:12:48 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/11/2024 18:11:14 06/11/2024 17:13:07 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/11/2024 06:27:15 06/11/2024 06:27:22 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/11/2024 06:27:01 06/11/2024 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/11/2024 13:30:50 05/11/2024 11:32:31 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/11/2024 13:30:44 05/11/2024 11:32:08 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 05/11/2024 13:30:39 05/11/2024 11:32:07 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 05/11/2024 12:30:48 05/11/2024 11:32:24 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/11/2024 12:30:48 05/11/2024 11:32:30 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/11/2024 12:30:48 05/11/2024 11:32:36 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/11/2024 12:30:48 05/11/2024 11:32:42 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/11/2024 12:30:48 05/11/2024 11:32:47 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/11/2024 12:30:48 05/11/2024 11:32:52 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/11/2024 12:30:48 05/11/2024 11:33:03 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/11/2024 12:30:48 05/11/2024 11:33:09 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/11/2024 12:30:48 05/11/2024 11:33:14 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 05/11/2024 12:30:48 05/11/2024 11:33:19 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 05/11/2024 12:30:48 05/11/2024 11:33:25 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/11/2024 12:30:48 05/11/2024 11:33:30 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 05/11/2024 12:30:31 05/11/2024 10:31:57 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 05/11/2024 11:39:10 05/11/2024 11:39:10 44139966 44139966 1,0 100 Temporary Fault Unclassified Alarm
KRM_SERVER 05/11/2024 06:27:08 05/11/2024 06:41:34 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/11/2024 06:27:03 04/11/2024 06:27:11 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/11/2024 06:28:16 03/11/2024 06:28:22 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/11/2024 06:28:17 02/11/2024 06:28:24 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/11/2024 06:28:19 01/11/2024 06:28:27 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/10/2024 06:28:21 31/10/2024 06:28:27 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/10/2024 10:35:17 30/10/2024 09:36:49 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 09:35:05 30/10/2024 08:36:50 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 09:34:58 30/10/2024 08:36:39 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 09:34:51 30/10/2024 08:36:23 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 09:34:51 30/10/2024 08:36:28 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 08:34:38 30/10/2024 07:36:19 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 08:34:38 30/10/2024 07:36:24 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 08:34:32 30/10/2024 07:36:14 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 08:34:25 30/10/2024 07:36:03 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 07:34:12 30/10/2024 06:36:06 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 07:34:06 30/10/2024 06:35:54 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 07:33:59 30/10/2024 06:35:42 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 06:33:46 30/10/2024 05:35:26 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 06:33:46 30/10/2024 05:35:32 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 06:33:40 30/10/2024 05:35:21 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 06:28:22 30/10/2024 06:28:29 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/10/2024 05:33:20 30/10/2024 04:35:12 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 05:33:13 30/10/2024 04:35:17 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 05:33:07 30/10/2024 04:35:06 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 05:32:05 30/10/2024 04:34:55 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 05:31:52 30/10/2024 04:34:12 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 30/10/2024 05:31:46 30/10/2024 04:33:33 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 30/10/2024 05:31:46 30/10/2024 04:33:38 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 30/10/2024 05:31:46 30/10/2024 04:33:44 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 30/10/2024 05:31:46 30/10/2024 04:34:01 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 30/10/2024 05:31:45 30/10/2024 04:33:22 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 30/10/2024 05:31:17 30/10/2024 04:33:10 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 30/10/2024 05:31:12 30/10/2024 04:35:28 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 30/10/2024 05:31:12 30/10/2024 04:35:33 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 30/10/2024 05:31:02 30/10/2024 04:36:26 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 30/10/2024 05:31:00 30/10/2024 04:33:54 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 30/10/2024 05:30:22 30/10/2024 04:32:14 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 30/10/2024 05:30:18 30/10/2024 04:31:56 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 05:30:18 30/10/2024 04:33:28 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 05:30:18 30/10/2024 04:33:50 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 04:30:05 30/10/2024 03:31:46 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 04:29:58 30/10/2024 03:31:51 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 03:29:39 30/10/2024 02:31:25 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 03:29:32 30/10/2024 02:31:08 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 03:29:26 30/10/2024 02:31:03 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 02:29:06 30/10/2024 01:30:50 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 01:28:47 30/10/2024 00:30:32 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 01:28:40 30/10/2024 00:30:21 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 00:28:21 29/10/2024 23:30:08 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 00:28:21 29/10/2024 23:30:13 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 00:28:14 29/10/2024 23:29:56 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 00:28:14 29/10/2024 23:30:03 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 00:27:06 29/10/2024 23:29:16 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 00:26:53 29/10/2024 23:29:27 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 30/10/2024 00:26:52 29/10/2024 23:29:38 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 30/10/2024 00:26:46 29/10/2024 23:30:24 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 30/10/2024 00:26:46 29/10/2024 23:30:36 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 30/10/2024 00:26:21 29/10/2024 23:28:59 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 30/10/2024 00:26:18 29/10/2024 23:28:48 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 30/10/2024 00:26:13 29/10/2024 23:28:26 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 30/10/2024 00:26:11 29/10/2024 23:28:03 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 30/10/2024 00:26:11 29/10/2024 23:28:08 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 30/10/2024 00:26:11 29/10/2024 23:31:21 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 30/10/2024 00:25:48 29/10/2024 23:28:37 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 30/10/2024 00:25:47 29/10/2024 23:27:52 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 30/10/2024 00:25:47 29/10/2024 23:28:20 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 30/10/2024 00:25:31 29/10/2024 23:27:07 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 00:25:31 29/10/2024 23:27:47 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 30/10/2024 00:25:31 29/10/2024 23:31:26 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 30/10/2024 00:25:30 29/10/2024 23:27:02 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 23:25:18 29/10/2024 22:27:17 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 23:25:11 29/10/2024 22:26:54 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 23:25:04 29/10/2024 22:26:41 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 23:25:04 29/10/2024 22:26:47 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 23:24:03 29/10/2024 22:26:09 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 23:23:56 29/10/2024 22:26:15 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 23:23:49 29/10/2024 22:26:20 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 23:23:43 29/10/2024 22:26:31 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/10/2024 23:23:43 29/10/2024 22:27:28 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 23:23:18 29/10/2024 22:27:52 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 23:23:17 29/10/2024 22:27:57 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 23:23:14 29/10/2024 22:28:02 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 23:23:13 29/10/2024 22:28:14 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 23:23:12 29/10/2024 22:25:58 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 23:23:12 29/10/2024 22:28:25 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 23:23:11 29/10/2024 22:25:21 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 23:23:11 29/10/2024 22:25:42 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 23:23:11 29/10/2024 22:25:53 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 23:23:10 29/10/2024 22:25:05 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 23:23:10 29/10/2024 22:25:10 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 23:23:10 29/10/2024 22:25:37 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 23:23:10 29/10/2024 22:28:41 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 23:22:52 29/10/2024 22:24:48 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 23:22:52 29/10/2024 22:24:54 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 23:22:52 29/10/2024 22:25:16 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 23:22:30 29/10/2024 22:24:20 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 23:22:30 29/10/2024 22:24:31 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 23:22:28 29/10/2024 22:24:15 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 23:22:27 29/10/2024 22:23:59 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 23:22:27 29/10/2024 22:24:04 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 22:22:14 29/10/2024 21:24:00 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 22:22:07 29/10/2024 21:23:49 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 22:22:01 29/10/2024 21:23:33 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 22:22:01 29/10/2024 21:23:38 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 21:21:41 29/10/2024 20:23:29 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 21:21:34 29/10/2024 20:23:06 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 21:21:34 29/10/2024 20:23:12 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 20:21:15 29/10/2024 19:22:57 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 20:21:08 29/10/2024 19:22:49 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 20:20:07 29/10/2024 22:24:26 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 20:19:48 29/10/2024 19:23:19 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/10/2024 20:19:48 29/10/2024 19:23:25 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 29/10/2024 20:19:47 29/10/2024 19:23:29 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 20:19:27 29/10/2024 19:24:13 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 20:19:27 29/10/2024 19:24:18 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 20:19:27 29/10/2024 19:24:24 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 20:19:24 29/10/2024 19:22:06 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 20:19:23 29/10/2024 19:21:48 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 20:19:20 29/10/2024 19:21:43 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 20:19:17 29/10/2024 19:21:04 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 20:19:17 29/10/2024 19:22:01 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 20:19:17 29/10/2024 19:25:04 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 20:18:52 29/10/2024 19:20:37 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 20:18:52 29/10/2024 19:25:11 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 20:18:38 29/10/2024 19:20:10 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 20:18:38 29/10/2024 19:20:16 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 19:18:19 29/10/2024 18:19:56 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 19:18:12 29/10/2024 18:19:45 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 19:17:10 29/10/2024 19:20:54 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 19:16:57 29/10/2024 18:20:29 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 19:16:57 29/10/2024 19:20:59 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 19:16:51 29/10/2024 18:20:39 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 29/10/2024 19:16:51 29/10/2024 18:20:45 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 19:16:39 29/10/2024 18:20:55 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 19:16:39 29/10/2024 18:21:01 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 19:16:35 29/10/2024 18:18:58 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 19:16:34 29/10/2024 18:18:52 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 19:16:31 29/10/2024 18:18:36 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 19:16:31 29/10/2024 18:18:41 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 19:16:30 29/10/2024 18:19:09 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 19:16:28 29/10/2024 18:18:14 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 19:16:28 29/10/2024 18:21:23 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 19:15:46 29/10/2024 18:17:28 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 19:15:46 29/10/2024 18:17:33 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 19:15:45 29/10/2024 18:17:22 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 19:15:38 29/10/2024 18:17:10 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 18:15:26 29/10/2024 17:17:19 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 18:15:26 29/10/2024 17:17:24 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 18:15:19 29/10/2024 17:17:08 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 18:15:12 29/10/2024 17:16:50 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 18:14:04 29/10/2024 17:16:37 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 18:13:58 29/10/2024 18:17:49 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 18:13:57 29/10/2024 17:17:30 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 18:13:52 29/10/2024 17:17:53 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 18:13:29 29/10/2024 17:18:09 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 18:13:28 29/10/2024 17:18:15 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 18:13:27 29/10/2024 17:18:20 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 18:13:27 29/10/2024 17:18:31 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 18:13:22 29/10/2024 17:16:02 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 18:13:18 29/10/2024 17:15:03 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 18:13:18 29/10/2024 17:18:49 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 18:12:51 29/10/2024 17:14:35 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 18:12:51 29/10/2024 17:15:14 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 17:12:25 29/10/2024 16:14:42 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 17:11:23 29/10/2024 16:14:16 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 17:11:23 29/10/2024 17:14:57 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 17:11:16 29/10/2024 16:13:47 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 17:11:10 29/10/2024 16:13:36 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 17:11:10 29/10/2024 16:13:53 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 17:11:04 29/10/2024 16:12:51 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/10/2024 17:11:04 29/10/2024 16:13:13 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/10/2024 17:11:04 29/10/2024 16:14:10 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 17:10:22 29/10/2024 16:14:53 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 17:10:22 29/10/2024 16:14:59 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 17:10:19 29/10/2024 16:15:11 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 17:10:08 29/10/2024 16:15:55 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 17:10:07 29/10/2024 16:12:25 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 17:10:06 29/10/2024 16:12:19 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 17:10:03 29/10/2024 16:11:45 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 17:10:03 29/10/2024 16:12:08 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 17:10:02 29/10/2024 16:11:57 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 17:09:50 29/10/2024 16:12:14 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 17:09:50 29/10/2024 16:13:02 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 17:09:14 29/10/2024 16:11:34 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 17:09:13 29/10/2024 16:10:56 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 17:09:12 29/10/2024 16:10:44 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 17:09:12 29/10/2024 16:12:35 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 16:08:53 29/10/2024 15:10:32 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 16:08:47 29/10/2024 15:10:22 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 16:08:47 29/10/2024 15:10:27 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 16:07:45 29/10/2024 15:09:36 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 16:07:38 29/10/2024 15:09:15 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 16:07:38 29/10/2024 15:09:25 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 16:07:32 29/10/2024 15:09:09 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 16:07:32 29/10/2024 16:11:01 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 16:07:31 29/10/2024 15:09:20 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 16:07:31 29/10/2024 15:09:47 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 16:06:54 29/10/2024 15:10:11 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 16:06:52 29/10/2024 15:10:16 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 16:06:23 29/10/2024 15:11:27 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 16:06:21 29/10/2024 15:11:43 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 16:06:19 29/10/2024 15:12:11 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 16:06:15 29/10/2024 15:08:47 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 16:06:10 29/10/2024 15:08:34 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 16:06:10 29/10/2024 15:08:53 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 16:06:10 29/10/2024 15:08:58 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 16:06:09 29/10/2024 15:08:01 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 16:06:09 29/10/2024 15:08:42 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 16:06:09 29/10/2024 15:12:33 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 16:05:52 29/10/2024 15:07:56 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 16:05:52 29/10/2024 15:08:22 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 16:05:29 29/10/2024 15:07:15 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 16:05:29 29/10/2024 15:07:38 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 16:05:27 29/10/2024 15:07:04 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 16:05:27 29/10/2024 15:12:38 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 15:03:59 29/10/2024 14:18:59 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 15:03:59 29/10/2024 15:07:25 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 15:03:52 29/10/2024 14:06:35 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 15:03:45 29/10/2024 14:06:29 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 15:03:39 29/10/2024 14:05:38 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/10/2024 15:03:39 29/10/2024 14:06:00 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 29/10/2024 15:03:39 29/10/2024 14:06:06 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/10/2024 15:02:24 29/10/2024 14:07:47 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 15:02:22 29/10/2024 14:08:03 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 15:02:18 29/10/2024 14:08:24 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 15:01:12 29/10/2024 14:03:51 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 15:01:12 29/10/2024 14:04:07 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 15:01:10 29/10/2024 14:02:48 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 15:01:10 29/10/2024 14:02:53 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 15:01:10 29/10/2024 14:03:15 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 15:01:06 29/10/2024 14:03:04 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 15:00:48 29/10/2024 14:02:36 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 14:59:54 29/10/2024 14:01:26 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 14:59:54 29/10/2024 14:02:24 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 14:59:06 29/10/2024 14:00:45 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 13:57:21 29/10/2024 13:00:16 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 13:57:15 29/10/2024 12:58:57 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 13:57:15 29/10/2024 12:59:05 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 29/10/2024 13:57:15 29/10/2024 12:59:35 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/10/2024 13:57:15 29/10/2024 13:01:10 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 13:55:24 29/10/2024 13:00:04 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 13:55:23 29/10/2024 12:58:12 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 13:53:14 29/10/2024 13:01:21 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 13:53:12 29/10/2024 13:01:26 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 13:53:07 29/10/2024 13:01:32 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 13:53:06 29/10/2024 13:01:42 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 13:52:35 29/10/2024 12:55:01 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 13:52:32 29/10/2024 12:54:18 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 13:52:32 29/10/2024 12:54:29 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 13:51:00 29/10/2024 12:52:56 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 13:50:58 29/10/2024 12:52:38 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 13:50:57 29/10/2024 12:52:31 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 13:50:57 29/10/2024 12:59:23 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 13:50:29 29/10/2024 12:52:15 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 13:50:27 29/10/2024 12:52:04 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 13:50:27 29/10/2024 12:59:17 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 12:48:46 29/10/2024 12:10:31 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 12:48:46 29/10/2024 12:52:09 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 12:48:45 29/10/2024 12:10:36 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 12:46:20 29/10/2024 12:14:09 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 12:45:19 29/10/2024 12:14:14 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 12:45:12 29/10/2024 12:14:19 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 12:45:05 29/10/2024 12:14:25 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 12:43:15 29/10/2024 12:18:49 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 12:43:14 29/10/2024 12:18:55 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 12:41:53 29/10/2024 11:45:27 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/10/2024 12:41:53 29/10/2024 11:46:56 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 29/10/2024 12:41:53 29/10/2024 11:47:12 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 12:41:31 29/10/2024 11:51:12 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 12:39:28 29/10/2024 11:52:39 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 29/10/2024 12:38:32 29/10/2024 11:57:50 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 12:38:25 29/10/2024 11:57:57 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 12:38:15 29/10/2024 11:58:15 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 12:36:50 29/10/2024 11:58:54 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 12:36:46 29/10/2024 11:59:18 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 12:36:46 29/10/2024 11:59:24 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 12:36:45 29/10/2024 11:59:39 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 12:36:44 29/10/2024 11:59:50 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 12:36:42 29/10/2024 12:00:11 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 12:25:57 29/10/2024 11:34:34 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 12:24:12 29/10/2024 11:26:10 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 12:23:52 29/10/2024 11:26:38 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 29/10/2024 12:12:18 29/10/2024 11:15:07 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 12:12:12 29/10/2024 11:14:46 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 12:12:11 29/10/2024 11:14:56 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 12:12:05 29/10/2024 11:13:47 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 12:12:05 29/10/2024 11:14:07 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 29/10/2024 12:12:05 29/10/2024 11:14:34 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/10/2024 12:12:05 29/10/2024 11:15:02 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 12:12:05 29/10/2024 11:15:24 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 12:11:26 29/10/2024 11:14:23 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 12:11:08 29/10/2024 11:14:18 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 12:09:46 29/10/2024 11:13:08 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 12:08:32 29/10/2024 11:10:32 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 12:05:57 29/10/2024 11:07:35 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 12:05:57 29/10/2024 11:07:46 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 12:00:52 29/10/2024 11:02:40 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 12:00:31 29/10/2024 11:02:05 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 11:58:26 29/10/2024 11:00:47 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 11:58:18 29/10/2024 11:00:11 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 11:58:18 29/10/2024 11:00:17 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 11:58:07 29/10/2024 10:59:55 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 11:58:07 29/10/2024 11:00:00 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 11:58:07 29/10/2024 11:00:24 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 11:58:07 29/10/2024 11:00:58 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 11:56:29 29/10/2024 10:59:27 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 11:55:58 29/10/2024 10:58:02 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 11:55:58 29/10/2024 10:58:08 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 11:55:58 29/10/2024 10:58:24 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 11:55:57 29/10/2024 10:57:40 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 11:55:57 29/10/2024 10:57:52 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 11:55:57 29/10/2024 10:58:13 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 11:55:57 29/10/2024 10:58:18 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 11:55:56 29/10/2024 10:57:30 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 11:55:40 29/10/2024 10:57:20 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 11:55:13 29/10/2024 10:56:45 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 10:54:47 29/10/2024 09:57:08 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 10:53:45 29/10/2024 09:56:52 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 10:53:45 29/10/2024 10:56:56 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 10:53:38 29/10/2024 09:56:36 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 10:53:32 29/10/2024 09:56:20 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 10:53:26 29/10/2024 09:55:33 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 29/10/2024 10:53:26 29/10/2024 09:55:41 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/10/2024 10:53:26 29/10/2024 09:56:02 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/10/2024 10:53:25 29/10/2024 09:55:11 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 10:53:25 29/10/2024 09:55:17 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 10:53:25 29/10/2024 09:56:41 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 10:53:25 29/10/2024 09:57:19 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 10:53:23 29/10/2024 09:55:05 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 10:53:02 29/10/2024 09:54:54 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 10:52:58 29/10/2024 09:57:25 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 10:52:57 29/10/2024 09:57:30 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 10:52:52 29/10/2024 09:57:57 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 10:52:46 29/10/2024 09:59:04 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 10:52:33 29/10/2024 09:54:47 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 10:52:31 29/10/2024 09:54:30 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 10:52:27 29/10/2024 09:54:02 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 10:52:27 29/10/2024 09:54:24 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 10:52:14 29/10/2024 09:53:46 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 10:52:14 29/10/2024 09:54:35 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 10:51:21 29/10/2024 09:55:51 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 09:51:07 29/10/2024 08:52:49 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 09:51:01 29/10/2024 08:52:38 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 09:50:54 29/10/2024 08:52:33 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 09:49:52 29/10/2024 08:51:38 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 09:49:39 29/10/2024 08:51:14 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 09:49:33 29/10/2024 08:51:43 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 09:49:33 29/10/2024 09:53:08 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 09:49:26 29/10/2024 08:52:10 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 09:49:17 29/10/2024 08:53:21 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 09:49:14 29/10/2024 08:53:43 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 09:49:04 29/10/2024 08:54:05 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 09:49:03 29/10/2024 08:50:35 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 09:49:03 29/10/2024 08:51:05 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 09:48:12 29/10/2024 08:51:00 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 09:47:36 29/10/2024 08:49:08 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 09:47:36 29/10/2024 08:54:21 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 08:47:24 29/10/2024 07:49:09 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 08:47:17 29/10/2024 07:48:58 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 08:47:17 29/10/2024 07:49:04 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 08:47:10 29/10/2024 07:48:47 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 08:47:10 29/10/2024 07:48:53 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 08:46:08 29/10/2024 07:48:02 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 08:46:08 29/10/2024 08:49:31 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 08:46:02 29/10/2024 07:48:08 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 08:45:55 29/10/2024 07:48:31 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 08:45:49 29/10/2024 07:48:36 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/10/2024 08:45:49 29/10/2024 07:48:42 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 29/10/2024 08:44:38 29/10/2024 07:47:33 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 08:44:30 29/10/2024 07:46:29 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 08:44:30 29/10/2024 07:46:58 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 08:44:26 29/10/2024 07:46:00 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 08:42:32 29/10/2024 07:44:32 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 08:42:32 29/10/2024 07:44:37 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 08:42:32 29/10/2024 07:44:48 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 07:41:50 29/10/2024 07:44:15 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 07:41:49 29/10/2024 06:43:38 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 07:41:49 29/10/2024 06:44:01 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 07:41:43 29/10/2024 06:43:16 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 07:41:43 29/10/2024 06:43:27 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 07:40:28 29/10/2024 06:45:34 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 07:40:21 29/10/2024 06:43:33 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 07:40:21 29/10/2024 06:43:56 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 07:40:21 29/10/2024 06:45:52 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 29/10/2024 07:38:31 29/10/2024 06:40:37 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 07:37:00 29/10/2024 06:38:39 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 07:37:00 29/10/2024 06:39:13 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 07:36:01 29/10/2024 06:38:45 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 07:35:41 29/10/2024 06:37:51 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 07:34:24 29/10/2024 06:36:06 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 07:34:24 29/10/2024 06:36:12 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 07:34:24 29/10/2024 06:36:33 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 07:34:24 29/10/2024 06:57:23 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 07:34:17 29/10/2024 06:35:54 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 07:32:49 29/10/2024 06:58:02 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 29/10/2024 07:32:44 29/10/2024 06:35:48 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 07:32:43 29/10/2024 06:36:28 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 07:32:29 29/10/2024 06:35:01 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 07:32:28 29/10/2024 06:34:39 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 07:32:28 29/10/2024 06:35:23 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 07:32:25 29/10/2024 06:34:06 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 07:32:23 29/10/2024 06:33:55 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 07:31:58 29/10/2024 06:33:41 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 07:31:57 29/10/2024 06:33:35 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 07:31:57 29/10/2024 06:45:11 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 07:31:18 29/10/2024 06:32:55 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 07:31:18 29/10/2024 06:34:44 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 07:30:05 29/10/2024 06:32:03 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 07:30:02 29/10/2024 06:31:34 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 07:30:02 29/10/2024 06:31:40 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 07:30:02 29/10/2024 06:45:16 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 07:30:02 29/10/2024 06:45:22 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 06:28:24 29/10/2024 06:28:32 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/10/2024 06:28:21 29/10/2024 06:31:57 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 04:14:00 29/10/2024 03:16:07 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 04:13:54 29/10/2024 03:15:50 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 04:13:53 29/10/2024 03:15:48 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 04:13:53 29/10/2024 03:16:12 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 04:13:47 29/10/2024 03:15:22 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 04:13:47 29/10/2024 03:15:40 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 04:12:32 29/10/2024 03:14:31 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 04:12:32 29/10/2024 03:14:37 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 04:12:32 29/10/2024 03:14:43 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 04:12:32 29/10/2024 03:15:27 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 04:12:32 29/10/2024 03:15:56 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 04:12:26 29/10/2024 03:14:14 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 29/10/2024 04:12:26 29/10/2024 03:14:19 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/10/2024 04:12:26 29/10/2024 03:14:53 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 04:12:26 29/10/2024 03:15:34 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 04:11:26 29/10/2024 03:14:48 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 04:11:25 29/10/2024 03:16:36 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:11:10 29/10/2024 03:17:01 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:11:07 29/10/2024 03:17:28 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:10:34 29/10/2024 03:13:52 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 04:10:29 29/10/2024 03:13:41 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:10:27 29/10/2024 03:12:57 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:10:27 29/10/2024 03:13:09 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:10:27 29/10/2024 03:13:25 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:10:26 29/10/2024 03:12:49 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:10:26 29/10/2024 03:13:02 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:10:25 29/10/2024 03:12:33 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 04:10:25 29/10/2024 03:13:20 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 04:10:24 29/10/2024 03:11:59 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:10:24 29/10/2024 03:12:04 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 04:10:24 29/10/2024 03:12:16 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:10:24 29/10/2024 03:12:21 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 04:10:24 29/10/2024 03:12:28 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:10:24 29/10/2024 03:12:44 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:10:08 29/10/2024 03:11:46 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 04:10:08 29/10/2024 03:11:54 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:10:08 29/10/2024 03:12:38 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:10:08 29/10/2024 03:14:08 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 04:09:40 29/10/2024 03:11:12 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:09:40 29/10/2024 03:11:40 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:09:40 29/10/2024 03:12:10 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 04:08:17 29/10/2024 03:09:49 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 04:08:17 29/10/2024 03:09:54 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 04:08:17 29/10/2024 03:13:57 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 04:08:17 29/10/2024 03:14:03 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 03:08:05 29/10/2024 02:10:05 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 03:08:05 29/10/2024 03:11:29 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 03:08:04 29/10/2024 02:09:57 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 03:08:04 29/10/2024 02:10:22 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 03:07:57 29/10/2024 02:09:36 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 03:07:57 29/10/2024 02:09:46 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 29/10/2024 03:06:36 29/10/2024 02:08:48 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 03:06:36 29/10/2024 02:08:53 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 03:06:36 29/10/2024 02:09:11 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 03:06:36 29/10/2024 02:09:41 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 03:06:36 29/10/2024 02:10:10 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 03:06:36 29/10/2024 03:11:35 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 29/10/2024 03:06:30 29/10/2024 02:08:07 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 03:06:30 29/10/2024 02:08:12 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 29/10/2024 03:06:30 29/10/2024 02:08:18 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/10/2024 03:06:30 29/10/2024 02:08:35 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 29/10/2024 03:06:30 29/10/2024 02:08:40 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 29/10/2024 03:06:30 29/10/2024 02:09:52 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 29/10/2024 03:04:35 29/10/2024 02:07:12 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 03:04:35 29/10/2024 02:09:01 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 03:04:34 29/10/2024 02:07:24 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 03:04:29 29/10/2024 02:07:34 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 03:04:22 29/10/2024 02:07:50 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 03:04:22 29/10/2024 02:07:56 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 03:04:18 29/10/2024 02:09:23 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 03:03:51 29/10/2024 02:06:34 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 03:03:49 29/10/2024 02:06:23 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 03:03:49 29/10/2024 02:06:29 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 03:03:47 29/10/2024 02:06:18 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 03:03:46 29/10/2024 02:06:02 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 03:03:45 29/10/2024 02:05:49 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 03:03:45 29/10/2024 02:06:07 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 03:03:44 29/10/2024 02:05:33 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 03:03:44 29/10/2024 02:05:43 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 03:03:43 29/10/2024 02:05:27 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 03:03:43 29/10/2024 02:06:40 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 03:03:42 29/10/2024 02:05:17 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 03:03:42 29/10/2024 02:05:38 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 03:03:28 29/10/2024 02:05:00 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 03:03:28 29/10/2024 02:05:11 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 03:03:28 29/10/2024 02:05:56 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 03:03:28 29/10/2024 02:08:29 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 29/10/2024 03:00:21 29/10/2024 02:01:57 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 03:00:21 29/10/2024 02:05:06 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 03:00:19 29/10/2024 02:01:52 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 29/10/2024 03:00:19 29/10/2024 02:05:22 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 22:54:39 28/10/2024 22:54:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/10/2024 20:26:29 28/10/2024 19:28:03 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 20:26:21 28/10/2024 19:27:58 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 28/10/2024 20:26:21 28/10/2024 19:28:08 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 28/10/2024 20:26:18 28/10/2024 19:29:20 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 20:26:12 28/10/2024 19:29:31 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 28/10/2024 20:26:01 28/10/2024 19:29:44 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 20:25:13 28/10/2024 19:26:45 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 20:25:13 28/10/2024 19:30:11 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 20:24:25 28/10/2024 19:26:19 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 28/10/2024 20:24:25 28/10/2024 19:26:51 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 28/10/2024 20:24:02 28/10/2024 19:25:38 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 20:24:02 28/10/2024 19:25:52 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 20:23:15 28/10/2024 19:24:58 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 20:23:15 28/10/2024 19:25:32 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 20:23:06 28/10/2024 19:24:47 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 20:23:06 28/10/2024 19:24:53 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 20:23:04 28/10/2024 19:24:36 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 20:23:04 28/10/2024 19:26:24 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 19:40:56 28/10/2024 18:42:36 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 28/10/2024 19:40:56 28/10/2024 19:24:43 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 28/10/2024 19:40:35 28/10/2024 18:42:08 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 28/10/2024 19:40:35 28/10/2024 18:42:14 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 19:40:35 28/10/2024 18:42:24 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 19:40:35 28/10/2024 19:41:49 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 28/10/2024 19:39:20 28/10/2024 18:41:12 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 19:39:20 28/10/2024 18:42:42 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 19:39:19 28/10/2024 18:40:59 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 19:39:19 28/10/2024 18:42:19 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 19:39:17 28/10/2024 18:40:49 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 19:39:17 28/10/2024 18:40:54 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 19:39:17 29/10/2024 02:08:01 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 19:39:17 29/10/2024 02:08:24 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 18:38:51 28/10/2024 17:40:32 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 18:38:51 28/10/2024 17:40:43 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 18:37:49 28/10/2024 17:40:22 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 18:37:49 28/10/2024 17:40:27 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 18:37:42 28/10/2024 17:40:09 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 18:37:42 28/10/2024 17:40:16 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 18:37:35 28/10/2024 17:39:51 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 18:37:35 28/10/2024 17:40:04 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 18:37:29 28/10/2024 17:39:07 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 28/10/2024 18:37:29 28/10/2024 17:39:12 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 28/10/2024 18:37:29 28/10/2024 17:39:18 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 28/10/2024 18:37:29 28/10/2024 17:39:34 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 28/10/2024 18:37:29 28/10/2024 17:39:40 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 28/10/2024 18:37:29 28/10/2024 17:39:56 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 28/10/2024 18:30:42 28/10/2024 17:32:55 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 28/10/2024 18:30:42 28/10/2024 18:41:18 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 28/10/2024 18:30:40 28/10/2024 17:32:49 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 18:30:40 28/10/2024 17:33:00 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 18:30:33 28/10/2024 17:32:21 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 28/10/2024 18:30:33 28/10/2024 17:32:26 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 18:30:33 28/10/2024 17:32:37 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 18:30:33 28/10/2024 17:39:29 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 28/10/2024 18:29:58 28/10/2024 17:31:52 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 18:29:58 28/10/2024 17:32:05 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 18:29:58 28/10/2024 17:32:32 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 18:29:58 28/10/2024 17:39:24 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 18:29:57 28/10/2024 17:31:46 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 18:29:57 28/10/2024 17:33:06 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 18:29:56 28/10/2024 17:31:28 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 18:29:56 28/10/2024 17:39:02 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 17:29:43 28/10/2024 16:31:26 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 17:29:37 28/10/2024 16:31:32 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 17:29:30 28/10/2024 16:31:03 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 17:29:30 28/10/2024 16:31:16 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 16:29:22 28/10/2024 15:31:04 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 28/10/2024 16:29:22 28/10/2024 15:34:00 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 28/10/2024 16:29:21 28/10/2024 15:30:59 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 28/10/2024 16:29:21 28/10/2024 15:33:55 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 28/10/2024 16:27:47 28/10/2024 15:30:00 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 16:27:47 28/10/2024 15:30:05 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 16:27:47 28/10/2024 15:30:11 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 28/10/2024 16:27:47 28/10/2024 16:31:08 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 16:27:47 28/10/2024 17:32:10 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 28/10/2024 16:27:47 28/10/2024 17:32:15 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 16:27:45 28/10/2024 15:30:16 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 28/10/2024 16:27:45 28/10/2024 15:30:21 44139966 44139966 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/10/2024 16:27:45 28/10/2024 15:30:27 44139966 44139966 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/10/2024 16:27:41 28/10/2024 15:30:38 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 28/10/2024 16:27:41 28/10/2024 15:30:47 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 28/10/2024 16:27:36 28/10/2024 15:31:20 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 28/10/2024 16:27:36 28/10/2024 15:31:25 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 28/10/2024 16:27:36 28/10/2024 15:32:56 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/10/2024 16:27:36 28/10/2024 15:33:08 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 28/10/2024 16:27:35 28/10/2024 15:31:41 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 28/10/2024 16:27:35 28/10/2024 15:32:34 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 28/10/2024 16:27:35 28/10/2024 15:32:47 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/10/2024 16:27:34 28/10/2024 15:31:47 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 28/10/2024 16:27:34 28/10/2024 15:32:28 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 28/10/2024 16:27:00 28/10/2024 15:31:26 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 28/10/2024 16:27:00 28/10/2024 15:32:07 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 28/10/2024 16:26:59 28/10/2024 15:31:14 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 28/10/2024 16:26:59 28/10/2024 15:31:52 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 28/10/2024 16:26:39 28/10/2024 15:30:32 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 28/10/2024 16:26:39 28/10/2024 15:30:47 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 28/10/2024 16:26:39 28/10/2024 15:30:59 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 16:26:39 28/10/2024 15:31:57 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 16:26:39 28/10/2024 15:32:03 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 28/10/2024 16:26:39 28/10/2024 15:32:07 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 28/10/2024 16:26:38 28/10/2024 15:30:06 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 28/10/2024 16:26:38 28/10/2024 15:30:18 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 16:26:38 28/10/2024 15:32:13 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 16:14:21 28/10/2024 15:16:29 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 16:14:20 28/10/2024 15:16:18 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 28/10/2024 16:14:20 28/10/2024 15:16:23 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 16:14:19 28/10/2024 15:15:56 44139966 44139966 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/10/2024 16:14:19 28/10/2024 15:16:02 44139966 44139966 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/10/2024 16:14:19 28/10/2024 15:16:07 44139966 44139966 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/10/2024 16:14:19 28/10/2024 15:16:12 44139966 44139966 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/10/2024 16:14:15 28/10/2024 15:16:40 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/10/2024 16:14:15 28/10/2024 15:16:46 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/10/2024 16:14:15 28/10/2024 15:23:07 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/10/2024 16:14:15 28/10/2024 15:23:13 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/10/2024 16:14:10 28/10/2024 15:16:57 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 28/10/2024 16:14:10 28/10/2024 15:17:03 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 28/10/2024 16:14:09 28/10/2024 15:17:08 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/10/2024 16:14:09 28/10/2024 15:17:14 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/10/2024 16:13:28 28/10/2024 15:17:19 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/10/2024 16:13:27 28/10/2024 15:17:24 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/10/2024 16:13:19 28/10/2024 15:17:30 44139966 44139966 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 28/10/2024 16:13:19 28/10/2024 15:17:36 44139966 44139966 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 28/10/2024 16:13:19 28/10/2024 15:17:41 44139966 44139966 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 28/10/2024 16:13:19 28/10/2024 15:17:53 44139966 44139966 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 28/10/2024 16:13:17 28/10/2024 15:17:59 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/10/2024 16:13:17 28/10/2024 15:18:05 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/10/2024 16:12:25 28/10/2024 15:15:28 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 28/10/2024 16:12:25 28/10/2024 15:15:39 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 16:12:25 28/10/2024 15:15:39 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 16:12:25 28/10/2024 15:18:11 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 16:12:25 28/10/2024 15:18:16 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 16:12:25 28/10/2024 15:18:21 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 28/10/2024 16:12:24 28/10/2024 15:15:05 44139966 44139966 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/10/2024 16:12:24 28/10/2024 15:15:11 44139966 44139966 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/10/2024 16:12:24 28/10/2024 15:15:16 44139966 44139966 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/10/2024 16:12:24 28/10/2024 15:15:23 44139966 44139966 1,0 1004 Elevator Failure TTS serial communication broken. One channel
KRM_SERVER 28/10/2024 16:12:15 28/10/2024 15:13:57 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 28/10/2024 16:12:15 28/10/2024 15:14:03 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 28/10/2024 16:12:15 28/10/2024 15:14:21 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 28/10/2024 16:12:15 28/10/2024 15:14:26 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 28/10/2024 16:12:14 28/10/2024 15:13:46 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/10/2024 16:12:14 28/10/2024 15:13:52 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/10/2024 16:12:14 28/10/2024 15:14:37 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/10/2024 16:12:14 28/10/2024 15:15:00 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 28/10/2024 13:22:30 28/10/2024 12:24:02 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 13:22:30 28/10/2024 15:14:54 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 12:22:04 28/10/2024 11:23:36 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 28/10/2024 12:22:04 28/10/2024 15:14:48 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 28/10/2024 06:28:25 28/10/2024 06:28:32 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/10/2024 06:26:42 28/10/2024 06:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/10/2024 00:15:22 27/10/2024 23:36:04 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 28/10/2024 00:15:09 27/10/2024 23:36:09 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 00:15:09 27/10/2024 23:36:15 44139966 44139966 1,0 1115 Elevator Failure KCEMSC board failure - Safety input power supply
KRM_SERVER 28/10/2024 00:15:09 27/10/2024 23:36:20 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 28/10/2024 00:15:06 27/10/2024 23:36:26 44139966 44139966 1,0 1034 Elevator Failure safety circuit: Buffers supervision. Down input failure
KRM_SERVER 28/10/2024 00:15:06 27/10/2024 23:36:31 44139966 44139966 1,0 1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2)
KRM_SERVER 28/10/2024 00:15:06 27/10/2024 23:36:36 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 28/10/2024 00:15:06 27/10/2024 23:36:42 44139966 44139966 1,0 1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range
KRM_SERVER 28/10/2024 00:15:06 27/10/2024 23:36:47 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 28/10/2024 00:15:05 27/10/2024 23:36:52 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 28/10/2024 00:08:37 27/10/2024 23:10:52 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 00:08:36 27/10/2024 23:10:30 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 00:08:36 27/10/2024 23:10:46 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 28/10/2024 00:08:34 27/10/2024 23:10:41 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 23:59:49 27/10/2024 23:45:14 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 23:49:38 27/10/2024 22:51:18 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 23:39:28 27/10/2024 22:42:32 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 23:39:28 27/10/2024 22:42:44 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 23:34:24 27/10/2024 22:42:39 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 23:34:23 27/10/2024 22:36:18 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 23:34:22 27/10/2024 22:36:07 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 23:29:18 27/10/2024 22:31:26 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 23:29:18 27/10/2024 22:36:13 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 23:29:17 27/10/2024 22:30:58 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 23:29:17 27/10/2024 22:31:03 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 23:29:17 27/10/2024 22:31:32 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 23:29:17 27/10/2024 22:36:24 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 23:24:13 27/10/2024 22:30:35 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 23:24:13 27/10/2024 22:30:52 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 23:24:12 27/10/2024 22:25:51 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 23:24:12 27/10/2024 22:26:02 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 23:24:12 27/10/2024 22:31:08 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 23:24:12 27/10/2024 22:31:49 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 23:19:08 27/10/2024 22:25:56 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 23:19:07 27/10/2024 22:26:08 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 23:18:04 27/10/2024 22:19:37 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 23:14:02 27/10/2024 22:16:14 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 23:14:02 27/10/2024 22:19:53 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 23:14:02 27/10/2024 22:30:24 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 23:14:01 27/10/2024 22:15:50 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 23:14:01 27/10/2024 22:16:07 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 23:08:57 27/10/2024 22:10:52 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 23:08:57 27/10/2024 22:15:56 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 23:08:52 27/10/2024 22:10:24 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 23:08:52 27/10/2024 22:10:47 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:58:46 27/10/2024 22:10:29 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:53:40 27/10/2024 22:30:29 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:48:34 27/10/2024 21:50:07 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:48:34 27/10/2024 21:50:34 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:43:29 27/10/2024 21:45:08 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:43:29 27/10/2024 21:46:02 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:33:19 27/10/2024 21:35:12 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:33:19 27/10/2024 21:35:39 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:33:18 27/10/2024 21:34:50 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:28:14 27/10/2024 21:30:56 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:28:14 27/10/2024 21:34:56 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:28:13 27/10/2024 21:30:34 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:28:13 27/10/2024 21:30:40 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:28:13 27/10/2024 21:31:01 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:28:13 27/10/2024 21:40:13 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:28:12 27/10/2024 21:29:45 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:28:12 27/10/2024 21:30:03 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:23:09 27/10/2024 21:25:47 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:23:09 27/10/2024 21:29:57 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:23:08 27/10/2024 21:25:13 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:23:08 27/10/2024 21:25:25 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:23:08 27/10/2024 21:25:58 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:23:08 27/10/2024 21:30:21 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:23:07 27/10/2024 21:24:40 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:23:07 27/10/2024 21:25:36 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:18:03 27/10/2024 21:19:52 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:18:03 27/10/2024 21:19:58 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:18:03 27/10/2024 21:20:14 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:18:03 27/10/2024 21:25:03 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:18:02 27/10/2024 21:19:35 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:18:02 27/10/2024 21:20:09 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:12:57 27/10/2024 21:14:30 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:12:57 27/10/2024 21:14:36 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:12:57 27/10/2024 21:19:41 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:12:57 27/10/2024 21:19:47 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:07:51 27/10/2024 21:09:29 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:07:51 27/10/2024 21:14:41 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:07:51 27/10/2024 21:24:45 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:02:47 27/10/2024 21:04:53 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:02:47 27/10/2024 21:09:36 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 22:02:47 27/10/2024 21:09:42 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 22:02:46 27/10/2024 21:04:42 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 21:42:24 27/10/2024 20:43:58 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 21:42:24 27/10/2024 20:44:14 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 21:42:24 27/10/2024 21:04:47 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 21:32:14 27/10/2024 20:33:57 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 21:32:14 27/10/2024 20:44:20 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 21:32:13 27/10/2024 20:33:46 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 21:32:13 27/10/2024 20:44:09 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 21:22:03 27/10/2024 20:23:35 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 21:22:03 27/10/2024 20:33:53 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 21:16:57 27/10/2024 20:18:30 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 21:16:57 27/10/2024 20:18:48 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 21:16:57 27/10/2024 20:23:41 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 21:16:57 27/10/2024 20:34:02 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 21:11:52 27/10/2024 20:13:30 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 21:11:52 27/10/2024 20:18:36 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 21:06:47 27/10/2024 20:08:19 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 21:06:47 27/10/2024 20:18:54 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:56:36 27/10/2024 20:08:25 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:51:30 27/10/2024 20:13:25 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:42:50 27/10/2024 18:42:55 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 27/10/2024 20:41:28 27/10/2024 18:43:12 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 27/10/2024 20:20:59 27/10/2024 19:23:27 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 20:20:59 27/10/2024 19:23:51 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 20:20:58 27/10/2024 19:23:05 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 20:20:58 27/10/2024 19:27:39 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 20:20:55 27/10/2024 19:22:54 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:15:48 27/10/2024 19:17:48 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:15:48 27/10/2024 19:18:00 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:15:48 27/10/2024 19:22:26 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:10:47 27/10/2024 19:13:27 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:10:47 27/10/2024 19:13:33 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:10:47 27/10/2024 19:17:19 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:10:47 27/10/2024 19:17:30 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:10:46 27/10/2024 19:12:52 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 20:10:46 27/10/2024 19:12:57 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:10:46 27/10/2024 19:13:08 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 20:10:46 27/10/2024 19:13:14 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:10:46 27/10/2024 19:13:39 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 20:10:46 27/10/2024 19:17:24 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 20:10:42 27/10/2024 19:12:46 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:10:42 27/10/2024 19:13:03 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:10:41 27/10/2024 19:12:41 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:10:41 27/10/2024 19:13:19 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:05:34 27/10/2024 19:07:29 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:05:34 27/10/2024 19:07:36 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:05:34 27/10/2024 19:12:12 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:05:34 27/10/2024 19:12:24 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:00:28 27/10/2024 19:07:06 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 20:00:28 27/10/2024 19:07:12 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:35:49 27/10/2024 18:36:44 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 19:35:49 27/10/2024 18:41:42 44139966 44139966 1,0 1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range
KRM_SERVER 27/10/2024 19:35:22 27/10/2024 18:36:28 44139966 44139966 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 27/10/2024 19:35:22 27/10/2024 18:37:17 44139966 44139966 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 27/10/2024 19:14:26 27/10/2024 18:15:58 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:14:26 27/10/2024 18:16:09 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:14:13 27/10/2024 18:15:13 44139966 44139966 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 27/10/2024 19:14:13 27/10/2024 18:15:42 44139966 44139966 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 27/10/2024 19:14:09 27/10/2024 18:15:03 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:14:09 27/10/2024 18:15:08 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:14:09 27/10/2024 18:15:19 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:14:09 27/10/2024 18:15:24 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:09:12 27/10/2024 18:10:06 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:09:12 27/10/2024 18:10:12 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:04:31 27/10/2024 18:05:30 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:04:31 27/10/2024 18:05:35 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:04:31 27/10/2024 18:06:01 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:04:31 27/10/2024 18:06:09 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:03:09 27/10/2024 18:04:38 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:03:09 27/10/2024 18:04:44 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:03:09 27/10/2024 18:04:54 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:03:09 27/10/2024 18:05:00 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:02:56 27/10/2024 18:04:03 44139966 44139966 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 27/10/2024 19:02:56 27/10/2024 18:04:27 44139966 44139966 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 27/10/2024 19:02:52 27/10/2024 18:03:46 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:02:52 27/10/2024 18:03:58 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:02:52 27/10/2024 18:04:10 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 19:02:52 27/10/2024 18:04:17 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 18:48:18 27/10/2024 17:50:16 44139966 44139966 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 27/10/2024 18:35:35 27/10/2024 17:36:41 44139966 44139966 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 27/10/2024 18:35:35 27/10/2024 17:37:10 44139966 44139966 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 27/10/2024 18:08:05 27/10/2024 17:09:10 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 18:07:06 27/10/2024 17:08:21 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 18:06:33 27/10/2024 17:08:00 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 18:06:33 27/10/2024 17:08:05 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 18:06:33 27/10/2024 17:08:11 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 18:06:09 27/10/2024 17:07:08 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 18:06:09 27/10/2024 17:07:13 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 18:06:09 27/10/2024 17:07:25 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 18:06:09 27/10/2024 17:07:31 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 18:05:26 27/10/2024 17:06:20 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 18:05:26 27/10/2024 17:06:31 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 17:57:12 27/10/2024 16:58:12 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 17:57:12 27/10/2024 16:58:18 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 17:57:12 27/10/2024 16:58:29 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 17:57:12 27/10/2024 16:58:34 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 17:56:36 27/10/2024 16:57:35 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 17:56:36 27/10/2024 16:57:50 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 17:56:35 27/10/2024 16:57:29 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 17:56:35 27/10/2024 16:57:56 44139966 44139966 1,0 1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range
KRM_SERVER 27/10/2024 07:26:44 27/10/2024 07:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/10/2024 07:26:46 26/10/2024 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/10/2024 05:33:34 26/10/2024 05:34:29 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 26/10/2024 05:33:34 26/10/2024 05:39:05 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/10/2024 10:04:15 25/10/2024 10:05:10 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/10/2024 10:04:15 25/10/2024 10:05:27 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/10/2024 09:56:12 25/10/2024 09:57:07 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/10/2024 09:56:12 25/10/2024 09:58:09 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/10/2024 07:26:47 25/10/2024 07:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/10/2024 07:26:48 24/10/2024 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/10/2024 07:26:51 23/10/2024 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/10/2024 07:26:51 22/10/2024 07:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/10/2024 16:28:43 21/10/2024 16:29:39 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/10/2024 16:28:43 21/10/2024 16:29:50 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/10/2024 07:26:53 21/10/2024 07:28:37 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/10/2024 07:26:53 21/10/2024 07:30:34 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/10/2024 07:26:54 20/10/2024 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/10/2024 17:29:42 19/10/2024 17:30:44 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 19/10/2024 17:29:42 19/10/2024 17:30:55 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 19/10/2024 17:29:42 19/10/2024 17:31:00 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 19/10/2024 17:29:42 19/10/2024 17:31:06 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 19/10/2024 07:26:56 19/10/2024 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/10/2024 07:26:58 18/10/2024 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/10/2024 07:27:00 17/10/2024 07:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/10/2024 07:27:01 16/10/2024 07:29:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/10/2024 07:27:02 15/10/2024 07:28:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/10/2024 07:27:04 14/10/2024 07:27:10 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/10/2024 07:26:33 13/10/2024 07:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/10/2024 07:26:34 12/10/2024 07:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/10/2024 07:26:36 11/10/2024 07:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/10/2024 07:26:37 10/10/2024 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/10/2024 15:55:40 09/10/2024 15:56:41 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/10/2024 15:55:40 09/10/2024 15:57:41 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/10/2024 07:26:38 09/10/2024 07:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/10/2024 07:26:40 08/10/2024 07:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/10/2024 07:26:47 07/10/2024 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/10/2024 07:26:43 06/10/2024 07:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/10/2024 07:26:45 05/10/2024 07:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/10/2024 07:26:46 04/10/2024 07:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/10/2024 07:26:48 03/10/2024 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/10/2024 07:26:55 02/10/2024 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/10/2024 11:00:36 01/10/2024 11:01:50 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 01/10/2024 07:26:51 01/10/2024 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/09/2024 07:26:52 30/09/2024 07:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/09/2024 07:26:54 29/09/2024 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/09/2024 07:26:55 28/09/2024 07:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/09/2024 07:26:56 27/09/2024 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/09/2024 07:26:59 26/09/2024 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/09/2024 07:27:00 25/09/2024 07:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/09/2024 07:27:01 24/09/2024 07:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/09/2024 22:49:38 23/09/2024 22:50:45 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 23/09/2024 22:49:38 23/09/2024 22:50:50 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 23/09/2024 22:49:38 23/09/2024 22:50:55 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 23/09/2024 22:49:38 23/09/2024 22:51:00 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 23/09/2024 15:55:09 23/09/2024 15:55:09 44139966 44139966 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 23/09/2024 15:54:56 23/09/2024 15:56:18 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/09/2024 15:54:56 23/09/2024 15:58:53 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/09/2024 15:54:55 23/09/2024 15:56:12 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/09/2024 15:54:55 23/09/2024 15:58:48 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 23/09/2024 07:27:05 23/09/2024 07:27:13 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/09/2024 07:27:05 22/09/2024 07:27:13 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/09/2024 07:27:06 21/09/2024 07:27:14 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/09/2024 07:27:09 20/09/2024 07:27:15 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/09/2024 07:27:10 19/09/2024 07:27:16 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/09/2024 07:27:11 18/09/2024 07:27:18 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/09/2024 07:27:13 17/09/2024 07:27:20 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/09/2024 07:27:14 16/09/2024 07:27:20 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/09/2024 07:27:16 15/09/2024 07:27:23 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/09/2024 09:36:54 14/09/2024 09:38:06 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 14/09/2024 09:36:54 14/09/2024 09:38:16 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 14/09/2024 07:27:17 14/09/2024 07:27:23 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/09/2024 07:27:18 13/09/2024 07:27:25 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/09/2024 16:55:40 12/09/2024 16:56:50 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/09/2024 16:55:40 12/09/2024 16:57:10 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/09/2024 10:34:19 12/09/2024 10:35:31 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/09/2024 10:34:19 12/09/2024 10:35:49 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/09/2024 07:27:20 12/09/2024 07:27:27 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/09/2024 07:27:21 11/09/2024 07:27:29 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/09/2024 07:27:23 10/09/2024 07:27:29 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/09/2024 07:27:25 09/09/2024 07:27:31 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/09/2024 07:27:26 08/09/2024 07:27:32 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/09/2024 07:27:28 07/09/2024 07:27:34 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/09/2024 07:27:28 06/09/2024 07:27:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/09/2024 07:27:30 05/09/2024 07:27:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/09/2024 08:59:36 04/09/2024 09:00:49 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 04/09/2024 08:59:36 04/09/2024 09:03:54 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 04/09/2024 07:27:32 04/09/2024 07:27:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/09/2024 07:27:34 03/09/2024 07:27:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/09/2024 07:27:00 03/09/2024 07:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/09/2024 15:57:01 02/09/2024 13:58:27 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 02/09/2024 15:56:35 02/09/2024 13:58:13 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 02/09/2024 15:56:33 02/09/2024 13:58:00 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 02/09/2024 15:55:54 02/09/2024 13:57:21 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 02/09/2024 14:46:22 02/09/2024 12:47:25 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 02/09/2024 14:46:18 02/09/2024 12:47:13 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 02/09/2024 14:46:14 02/09/2024 12:47:30 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 02/09/2024 14:38:52 02/09/2024 12:39:35 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 02/09/2024 07:27:03 02/09/2024 07:45:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/09/2024 07:27:08 01/09/2024 07:27:14 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/08/2024 07:27:10 31/08/2024 07:27:16 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/08/2024 07:27:11 30/08/2024 07:27:19 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/08/2024 07:27:15 29/08/2024 07:27:21 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/08/2024 07:27:14 28/08/2024 07:27:20 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/08/2024 07:27:16 27/08/2024 07:27:23 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/08/2024 07:27:17 26/08/2024 07:27:23 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/08/2024 07:27:18 25/08/2024 07:27:25 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/08/2024 07:27:20 24/08/2024 07:27:26 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/08/2024 07:27:22 23/08/2024 07:27:29 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/08/2024 07:27:23 22/08/2024 07:27:29 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/08/2024 07:27:30 21/08/2024 07:27:37 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/08/2024 07:27:25 20/08/2024 07:27:33 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/08/2024 07:27:22 19/08/2024 07:27:28 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/08/2024 02:04:39 19/08/2024 00:05:42 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 19/08/2024 02:04:19 19/08/2024 00:05:18 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 19/08/2024 02:04:18 19/08/2024 00:05:18 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 19/08/2024 02:02:29 19/08/2024 00:03:28 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 18/08/2024 07:27:24 18/08/2024 07:27:30 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/08/2024 11:20:24 17/08/2024 11:21:25 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/08/2024 11:20:24 17/08/2024 11:21:36 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/08/2024 07:27:16 17/08/2024 07:27:22 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/08/2024 22:01:03 16/08/2024 20:02:18 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 16/08/2024 22:00:38 16/08/2024 20:02:04 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 16/08/2024 22:00:37 16/08/2024 20:01:50 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 16/08/2024 21:59:01 16/08/2024 20:00:15 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 16/08/2024 21:32:08 16/08/2024 19:33:27 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 16/08/2024 21:31:48 16/08/2024 19:33:13 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 16/08/2024 21:31:46 16/08/2024 19:33:00 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 16/08/2024 21:31:21 16/08/2024 19:32:35 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 16/08/2024 21:24:13 16/08/2024 19:25:27 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 16/08/2024 21:23:49 16/08/2024 19:25:12 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 16/08/2024 21:23:46 16/08/2024 19:24:59 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 16/08/2024 21:23:11 16/08/2024 19:24:24 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 16/08/2024 21:15:24 16/08/2024 19:16:37 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 16/08/2024 21:15:07 16/08/2024 19:16:22 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 16/08/2024 21:15:04 16/08/2024 19:16:09 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 16/08/2024 20:24:37 16/08/2024 18:25:41 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 16/08/2024 11:26:56 16/08/2024 11:26:56 44139966 44139966 1,0 102 Temporary Fault Test Alarm
KRM_SERVER 16/08/2024 07:27:17 16/08/2024 07:27:23 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/08/2024 07:27:19 15/08/2024 07:27:25 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/08/2024 07:27:20 14/08/2024 16:26:13 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/08/2024 07:27:21 13/08/2024 07:27:28 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/08/2024 07:21:28 13/08/2024 05:22:38 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 13/08/2024 07:21:23 13/08/2024 05:22:01 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 13/08/2024 07:21:22 13/08/2024 05:22:01 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 13/08/2024 07:20:01 13/08/2024 05:20:39 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 12/08/2024 07:27:04 14/08/2024 07:40:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/08/2024 07:29:15 11/08/2024 07:29:21 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/08/2024 07:29:16 13/08/2024 23:02:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/08/2024 07:29:17 13/08/2024 18:42:26 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/08/2024 09:08:44 08/08/2024 09:10:16 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 08/08/2024 07:29:19 08/08/2024 07:29:25 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/08/2024 07:29:20 13/08/2024 09:58:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/08/2024 07:29:21 13/08/2024 05:39:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/08/2024 07:53:29 05/08/2024 07:54:17 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 05/08/2024 07:50:16 05/08/2024 07:51:40 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 05/08/2024 07:29:23 05/08/2024 07:29:29 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/08/2024 07:26:42 05/08/2024 07:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/08/2024 23:30:29 04/08/2024 21:31:43 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 04/08/2024 23:30:29 04/08/2024 21:31:30 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 04/08/2024 23:27:03 04/08/2024 21:28:04 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 04/08/2024 23:13:09 04/08/2024 21:14:20 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 04/08/2024 23:13:06 04/08/2024 21:14:07 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 04/08/2024 23:12:30 04/08/2024 21:13:31 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 04/08/2024 22:57:04 04/08/2024 20:58:05 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 04/08/2024 22:56:38 04/08/2024 20:57:38 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 04/08/2024 22:56:02 04/08/2024 20:57:03 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 04/08/2024 22:43:23 04/08/2024 20:41:55 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 04/08/2024 22:41:04 04/08/2024 20:42:22 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 04/08/2024 07:26:44 04/08/2024 07:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/08/2024 13:47:10 03/08/2024 13:46:49 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 03/08/2024 13:47:10 03/08/2024 13:47:01 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 03/08/2024 11:39:01 03/08/2024 11:38:51 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 03/08/2024 07:26:45 03/08/2024 07:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/08/2024 07:52:30 02/08/2024 07:52:14 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/08/2024 07:52:30 02/08/2024 07:52:25 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/08/2024 07:26:47 02/08/2024 07:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/08/2024 15:54:24 01/08/2024 15:54:03 44139966 44139966 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 01/08/2024 15:52:51 01/08/2024 15:52:51 44139966 44139966 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 01/08/2024 07:26:50 01/08/2024 07:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/07/2024 07:26:49 31/07/2024 07:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/07/2024 09:04:15 30/07/2024 09:03:55 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/07/2024 09:04:15 30/07/2024 09:04:32 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/07/2024 07:26:51 30/07/2024 09:27:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/07/2024 07:26:54 29/07/2024 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/07/2024 07:27:05 28/07/2024 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/07/2024 00:03:50 28/07/2024 00:03:30 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 28/07/2024 00:03:50 28/07/2024 00:28:32 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/07/2024 07:26:58 27/07/2024 07:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/07/2024 07:26:59 26/07/2024 07:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/07/2024 07:27:09 25/07/2024 07:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/07/2024 07:27:10 24/07/2024 07:27:10 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/07/2024 07:27:03 23/07/2024 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/07/2024 07:27:04 22/07/2024 07:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/07/2024 11:11:21 21/07/2024 11:11:04 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/07/2024 11:11:21 21/07/2024 11:12:05 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/07/2024 07:26:36 21/07/2024 07:26:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/07/2024 12:12:18 20/07/2024 12:12:01 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/07/2024 12:12:18 20/07/2024 12:12:06 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/07/2024 07:26:37 20/07/2024 07:26:37 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/07/2024 07:26:39 19/07/2024 07:26:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/07/2024 07:26:40 18/07/2024 07:26:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/07/2024 07:26:41 17/07/2024 07:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/07/2024 07:26:44 16/07/2024 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/07/2024 07:26:44 15/07/2024 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/07/2024 07:26:54 14/07/2024 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/07/2024 07:26:55 13/07/2024 07:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/07/2024 07:26:48 12/07/2024 07:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/07/2024 07:26:58 11/07/2024 07:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/07/2024 07:26:52 10/07/2024 07:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/07/2024 07:26:52 09/07/2024 07:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/07/2024 07:26:54 08/07/2024 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/07/2024 07:27:04 07/07/2024 07:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/07/2024 07:27:06 06/07/2024 07:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/07/2024 07:26:59 05/07/2024 07:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/07/2024 07:27:00 04/07/2024 07:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/07/2024 07:27:01 03/07/2024 07:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/07/2024 14:30:40 02/07/2024 14:30:30 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/07/2024 14:30:40 02/07/2024 14:30:36 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/07/2024 07:27:03 02/07/2024 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/07/2024 16:24:58 01/07/2024 16:24:58 44139966 44139966 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 01/07/2024 07:27:05 01/07/2024 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/06/2024 07:26:35 30/06/2024 07:26:35 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/06/2024 07:26:36 29/06/2024 07:26:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/06/2024 07:26:46 28/06/2024 07:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/06/2024 07:26:39 27/06/2024 07:26:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/06/2024 07:26:41 26/06/2024 07:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/06/2024 07:26:43 25/06/2024 07:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/06/2024 11:46:24 24/06/2024 11:46:16 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/06/2024 11:46:24 24/06/2024 11:46:45 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/06/2024 07:26:44 24/06/2024 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/06/2024 07:26:46 23/06/2024 07:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/06/2024 07:26:47 22/06/2024 07:26:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/06/2024 13:34:50 21/06/2024 13:34:43 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/06/2024 13:34:50 21/06/2024 13:34:53 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/06/2024 07:26:58 21/06/2024 07:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/06/2024 11:18:12 20/06/2024 11:18:16 44139966 44139966 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 20/06/2024 11:18:12 20/06/2024 11:18:43 44139966 44139966 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 20/06/2024 07:26:50 20/06/2024 07:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/06/2024 07:26:49 19/06/2024 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/06/2024 07:26:51 18/06/2024 07:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/06/2024 07:26:54 17/06/2024 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/06/2024 16:51:48 16/06/2024 16:51:53 44139966 44139966 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 16/06/2024 16:51:48 16/06/2024 16:52:09 44139966 44139966 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 16/06/2024 16:51:47 16/06/2024 16:51:42 44139966 44139966 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 16/06/2024 16:51:47 16/06/2024 16:51:47 44139966 44139966 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 16/06/2024 16:51:47 16/06/2024 16:51:58 44139966 44139966 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 16/06/2024 16:51:47 16/06/2024 16:52:04 44139966 44139966 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 16/06/2024 16:51:47 16/06/2024 16:52:15 44139966 44139966 1,0 1031 Elevator Failure Safety circuit: Landing door opened during drive
KRM_SERVER 16/06/2024 07:27:04 16/06/2024 07:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/06/2024 07:26:57 15/06/2024 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/06/2024 07:27:08 14/06/2024 07:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/06/2024 15:09:38 13/06/2024 15:09:34 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 13/06/2024 15:09:38 13/06/2024 15:09:40 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 13/06/2024 07:27:00 13/06/2024 07:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/06/2024 22:12:44 12/06/2024 22:12:40 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/06/2024 22:12:44 12/06/2024 22:13:58 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/06/2024 07:27:02 12/06/2024 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/06/2024 07:27:03 11/06/2024 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/06/2024 07:27:05 10/06/2024 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/06/2024 07:26:35 09/06/2024 07:26:35 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/06/2024 07:26:36 08/06/2024 07:26:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/06/2024 07:26:39 07/06/2024 07:26:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/06/2024 07:26:39 06/06/2024 07:26:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/06/2024 07:26:41 05/06/2024 07:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/06/2024 07:26:43 04/06/2024 07:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/06/2024 07:26:45 03/06/2024 07:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/06/2024 07:26:45 02/06/2024 07:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/06/2024 07:26:47 01/06/2024 07:26:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/05/2024 07:26:58 31/05/2024 07:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/05/2024 07:26:50 30/05/2024 07:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/05/2024 07:26:52 29/05/2024 07:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/05/2024 07:27:02 28/05/2024 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/05/2024 07:26:55 27/05/2024 07:35:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/05/2024 07:26:56 26/05/2024 07:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/05/2024 07:26:58 25/05/2024 07:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/05/2024 16:02:03 24/05/2024 16:02:03 44139966 44139966 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 24/05/2024 07:26:59 24/05/2024 07:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/05/2024 07:27:00 23/05/2024 07:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/05/2024 07:27:03 22/05/2024 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/05/2024 07:27:04 21/05/2024 07:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/05/2024 07:27:05 20/05/2024 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/05/2024 07:27:15 19/05/2024 07:27:15 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/05/2024 06:29:52 19/05/2024 06:29:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/05/2024 06:29:52 18/05/2024 06:29:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/05/2024 18:07:55 17/05/2024 16:08:15 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 17/05/2024 18:07:32 17/05/2024 16:08:01 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 17/05/2024 18:07:31 17/05/2024 16:07:48 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 17/05/2024 17:52:50 17/05/2024 15:53:06 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 17/05/2024 07:26:36 17/05/2024 07:26:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/05/2024 12:03:57 16/05/2024 10:04:15 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 16/05/2024 11:06:39 16/05/2024 10:03:59 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 16/05/2024 11:06:35 16/05/2024 10:03:46 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 16/05/2024 11:03:17 16/05/2024 10:00:28 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 16/05/2024 07:26:38 16/05/2024 07:26:38 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/05/2024 16:59:09 15/05/2024 16:59:14 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 15/05/2024 16:59:09 15/05/2024 16:59:19 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 15/05/2024 07:26:48 15/05/2024 07:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/05/2024 07:26:42 14/05/2024 07:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/05/2024 07:26:43 13/05/2024 07:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/05/2024 07:26:45 12/05/2024 07:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/05/2024 07:26:46 11/05/2024 07:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/05/2024 19:46:15 10/05/2024 20:45:29 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/05/2024 19:46:15 10/05/2024 20:45:48 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/05/2024 07:26:47 10/05/2024 07:26:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/05/2024 17:34:03 09/05/2024 18:33:18 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/05/2024 17:34:03 09/05/2024 18:33:59 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/05/2024 07:26:57 09/05/2024 07:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/05/2024 23:19:00 09/05/2024 00:18:14 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 08/05/2024 23:19:00 09/05/2024 00:18:59 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 08/05/2024 23:14:47 09/05/2024 00:14:01 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 08/05/2024 23:14:47 09/05/2024 00:15:22 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 08/05/2024 07:26:50 08/05/2024 07:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/05/2024 07:26:53 07/05/2024 07:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/05/2024 07:26:54 06/05/2024 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/05/2024 07:27:03 05/05/2024 07:28:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/05/2024 07:26:56 04/05/2024 07:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/05/2024 07:26:59 03/05/2024 07:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/05/2024 07:27:00 02/05/2024 07:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/05/2024 13:28:31 01/05/2024 14:27:49 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 01/05/2024 13:28:31 01/05/2024 14:28:01 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 01/05/2024 07:27:01 01/05/2024 07:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/04/2024 14:44:50 30/04/2024 15:44:08 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/04/2024 14:44:50 30/04/2024 15:46:11 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/04/2024 07:27:03 30/04/2024 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/04/2024 16:44:46 29/04/2024 17:44:06 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 29/04/2024 16:44:46 29/04/2024 17:44:22 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 29/04/2024 07:27:14 29/04/2024 07:27:14 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/04/2024 07:27:07 28/04/2024 07:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/04/2024 07:26:35 27/04/2024 07:26:35 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/04/2024 07:26:36 26/04/2024 07:26:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/04/2024 15:25:36 25/04/2024 16:24:56 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/04/2024 15:25:36 25/04/2024 16:27:58 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 25/04/2024 07:26:38 25/04/2024 07:26:38 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/04/2024 07:26:39 24/04/2024 07:26:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/04/2024 07:26:42 23/04/2024 07:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/04/2024 07:26:42 22/04/2024 07:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/04/2024 07:26:53 21/04/2024 07:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/04/2024 07:26:46 20/04/2024 07:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/04/2024 07:26:56 19/04/2024 07:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/04/2024 15:47:37 18/04/2024 16:47:01 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/04/2024 15:47:37 18/04/2024 16:48:53 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/04/2024 15:43:13 18/04/2024 16:42:37 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/04/2024 15:43:13 18/04/2024 16:44:30 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/04/2024 15:32:51 18/04/2024 16:32:15 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/04/2024 15:32:51 18/04/2024 16:38:39 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/04/2024 14:15:33 18/04/2024 15:14:57 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/04/2024 14:15:33 18/04/2024 15:20:22 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/04/2024 14:09:07 18/04/2024 15:08:31 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/04/2024 14:09:07 18/04/2024 15:12:25 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/04/2024 13:31:17 18/04/2024 14:30:41 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/04/2024 13:31:17 18/04/2024 14:30:52 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/04/2024 13:27:27 18/04/2024 14:26:51 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/04/2024 13:27:27 18/04/2024 14:27:53 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/04/2024 07:26:49 18/04/2024 07:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/04/2024 14:37:20 17/04/2024 15:36:45 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/04/2024 14:37:20 17/04/2024 15:38:58 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/04/2024 07:26:50 17/04/2024 07:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/04/2024 07:26:52 16/04/2024 07:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/04/2024 07:26:53 15/04/2024 07:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/04/2024 07:27:04 14/04/2024 07:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/04/2024 07:27:05 13/04/2024 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/04/2024 07:26:58 12/04/2024 07:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/04/2024 07:26:59 11/04/2024 07:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/04/2024 07:27:01 10/04/2024 07:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/04/2024 07:27:03 09/04/2024 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/04/2024 07:27:04 08/04/2024 07:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/04/2024 07:27:06 07/04/2024 07:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/04/2024 07:26:43 06/04/2024 07:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/04/2024 07:26:44 05/04/2024 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/04/2024 07:26:46 04/04/2024 07:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/04/2024 10:43:31 03/04/2024 11:43:01 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 03/04/2024 10:43:31 03/04/2024 11:43:19 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 03/04/2024 07:26:39 03/04/2024 07:26:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/04/2024 16:19:33 02/04/2024 16:19:33 44139966 44139966 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 02/04/2024 07:26:40 02/04/2024 07:26:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/04/2024 14:53:37 01/04/2024 15:53:08 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 01/04/2024 14:53:37 01/04/2024 15:54:06 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 01/04/2024 07:26:43 01/04/2024 07:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/03/2024 07:26:44 31/03/2024 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/03/2024 07:26:45 30/03/2024 07:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/03/2024 07:26:48 29/03/2024 07:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/03/2024 07:26:49 28/03/2024 07:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/03/2024 07:26:59 27/03/2024 07:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/03/2024 07:26:52 26/03/2024 07:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/03/2024 07:26:52 25/03/2024 07:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/03/2024 06:26:55 24/03/2024 06:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/03/2024 06:27:05 23/03/2024 06:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/03/2024 06:26:57 22/03/2024 06:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/03/2024 06:26:59 21/03/2024 06:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/03/2024 08:48:18 20/03/2024 08:47:54 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/03/2024 08:48:18 20/03/2024 08:48:46 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 20/03/2024 06:27:00 20/03/2024 06:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/03/2024 06:27:02 19/03/2024 06:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/03/2024 06:27:04 18/03/2024 06:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/03/2024 06:27:05 17/03/2024 06:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/03/2024 06:26:34 16/03/2024 06:26:34 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/03/2024 06:26:36 15/03/2024 06:26:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/03/2024 06:26:37 14/03/2024 06:26:37 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/03/2024 06:26:47 13/03/2024 06:26:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/03/2024 06:26:40 12/03/2024 06:26:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/03/2024 06:26:42 11/03/2024 06:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/03/2024 06:26:43 10/03/2024 06:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/03/2024 06:26:45 09/03/2024 06:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/03/2024 06:26:46 08/03/2024 06:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/03/2024 06:26:48 07/03/2024 06:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/03/2024 06:26:50 06/03/2024 06:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/03/2024 06:26:52 05/03/2024 06:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/03/2024 06:26:53 04/03/2024 06:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/03/2024 06:26:55 03/03/2024 06:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/03/2024 06:26:56 02/03/2024 06:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/03/2024 06:26:59 01/03/2024 06:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/02/2024 06:27:08 29/02/2024 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/02/2024 06:29:02 28/02/2024 06:29:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/02/2024 06:29:03 27/02/2024 06:29:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/02/2024 06:27:04 26/02/2024 06:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/02/2024 06:27:06 25/02/2024 06:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/02/2024 06:26:34 24/02/2024 06:26:34 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/02/2024 18:02:08 23/02/2024 18:01:56 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/02/2024 18:02:08 23/02/2024 18:02:08 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/02/2024 06:26:44 23/02/2024 06:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/02/2024 06:26:50 22/02/2024 06:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/02/2024 06:26:50 21/02/2024 06:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/02/2024 06:26:39 20/02/2024 06:26:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/02/2024 15:20:50 19/02/2024 15:20:50 44139966 44139966 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 19/02/2024 06:26:51 19/02/2024 06:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/02/2024 06:26:59 18/02/2024 06:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/02/2024 18:10:34 17/02/2024 18:10:25 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 17/02/2024 18:10:34 17/02/2024 18:10:30 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 17/02/2024 06:27:15 17/02/2024 06:27:15 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/02/2024 06:27:08 16/02/2024 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/02/2024 06:26:57 15/02/2024 06:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/02/2024 06:27:40 14/02/2024 06:27:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/02/2024 06:26:51 13/02/2024 06:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/02/2024 06:26:52 12/02/2024 06:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/02/2024 06:26:54 11/02/2024 06:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/02/2024 06:27:02 10/02/2024 06:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/02/2024 10:46:55 09/02/2024 10:46:50 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/02/2024 10:46:55 09/02/2024 10:47:08 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/02/2024 06:27:10 09/02/2024 06:27:10 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/02/2024 06:26:59 08/02/2024 06:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/02/2024 06:27:11 07/02/2024 06:27:11 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/02/2024 06:27:02 06/02/2024 06:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/02/2024 06:27:03 05/02/2024 06:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/02/2024 06:27:05 04/02/2024 06:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/02/2024 06:27:21 03/02/2024 06:27:21 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/02/2024 06:27:25 02/02/2024 06:27:25 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/02/2024 06:27:22 01/02/2024 06:27:22 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/01/2024 06:27:50 31/01/2024 06:27:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/01/2024 06:27:25 30/01/2024 06:27:25 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/01/2024 06:27:40 29/01/2024 06:27:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/01/2024 06:27:31 28/01/2024 06:27:31 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/01/2024 06:27:38 27/01/2024 06:27:38 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/01/2024 06:27:40 26/01/2024 06:27:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/01/2024 06:29:39 25/01/2024 06:29:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/01/2024 06:32:37 24/01/2024 06:32:37 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/01/2024 06:27:47 23/01/2024 06:27:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/01/2024 06:27:55 22/01/2024 06:27:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/01/2024 06:27:46 21/01/2024 06:27:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/01/2024 06:27:41 20/01/2024 06:27:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/01/2024 06:28:00 19/01/2024 06:28:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/01/2024 06:27:20 19/01/2024 06:27:20 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/01/2024 16:20:44 18/01/2024 15:21:06 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 18/01/2024 16:20:24 18/01/2024 15:20:54 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 18/01/2024 16:20:22 18/01/2024 15:20:40 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 18/01/2024 16:19:36 18/01/2024 15:19:54 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 18/01/2024 16:02:30 18/01/2024 15:02:15 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 18/01/2024 16:02:29 18/01/2024 15:02:02 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 18/01/2024 16:02:09 18/01/2024 15:02:39 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 18/01/2024 16:00:57 18/01/2024 15:00:30 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 18/01/2024 15:25:49 18/01/2024 15:25:49 44139966 44139966 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 18/01/2024 15:21:23 18/01/2024 15:22:41 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/01/2024 15:21:19 18/01/2024 15:22:52 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 15:21:19 18/01/2024 15:23:04 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 15:21:18 18/01/2024 15:23:10 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 15:21:18 18/01/2024 15:23:15 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 15:21:17 18/01/2024 15:21:44 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 18/01/2024 15:21:17 18/01/2024 15:21:50 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 18/01/2024 15:21:16 18/01/2024 15:21:33 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 18/01/2024 15:21:16 18/01/2024 15:21:39 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 18/01/2024 15:21:15 18/01/2024 15:21:22 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 18/01/2024 15:21:15 18/01/2024 15:21:28 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 18/01/2024 15:21:15 18/01/2024 15:22:31 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 18/01/2024 15:21:15 18/01/2024 15:22:36 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 18/01/2024 15:20:46 18/01/2024 15:22:06 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 15:20:46 18/01/2024 15:22:25 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 15:18:26 18/01/2024 15:18:42 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/01/2024 15:18:26 18/01/2024 15:19:01 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/01/2024 15:18:15 18/01/2024 15:18:21 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 15:18:15 18/01/2024 15:19:12 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 15:18:14 18/01/2024 15:18:26 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 15:18:14 18/01/2024 15:18:54 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 15:03:17 18/01/2024 15:04:02 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 18/01/2024 15:03:17 18/01/2024 15:04:08 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 15:03:17 18/01/2024 15:04:13 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 18/01/2024 15:03:17 18/01/2024 15:04:19 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 15:03:17 18/01/2024 15:18:31 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 18/01/2024 15:03:17 18/01/2024 15:18:37 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 18/01/2024 15:02:36 18/01/2024 15:03:30 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 15:02:36 18/01/2024 15:03:35 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/01/2024 15:02:36 18/01/2024 15:03:41 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 15:02:36 18/01/2024 15:03:46 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 15:02:36 18/01/2024 15:03:52 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/01/2024 15:02:36 18/01/2024 15:03:57 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 15:02:36 18/01/2024 15:04:30 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 15:02:36 18/01/2024 15:04:42 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/01/2024 15:02:36 18/01/2024 15:04:47 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 15:02:36 18/01/2024 15:18:09 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 15:02:36 18/01/2024 15:18:15 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 15:02:36 18/01/2024 15:19:07 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/01/2024 15:02:17 18/01/2024 15:02:27 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/01/2024 15:02:17 18/01/2024 15:02:32 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 15:02:17 18/01/2024 15:02:37 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/01/2024 15:02:17 18/01/2024 15:02:44 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 15:02:17 18/01/2024 15:02:57 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/01/2024 15:02:17 18/01/2024 15:03:02 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 15:02:17 18/01/2024 15:03:13 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/01/2024 15:02:17 18/01/2024 15:03:19 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 15:02:07 18/01/2024 15:02:15 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 15:02:07 18/01/2024 15:02:22 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 15:02:07 18/01/2024 15:02:50 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 15:02:07 18/01/2024 15:03:08 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 14:59:12 18/01/2024 14:59:21 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 14:59:12 18/01/2024 14:59:26 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/01/2024 14:59:12 18/01/2024 14:59:32 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 14:59:12 18/01/2024 14:59:37 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 14:59:12 18/01/2024 14:59:43 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/01/2024 14:59:12 18/01/2024 14:59:48 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 14:56:42 18/01/2024 14:56:43 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 14:56:42 18/01/2024 14:56:49 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/01/2024 14:56:42 18/01/2024 14:56:54 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 14:56:42 18/01/2024 14:57:00 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 14:56:42 18/01/2024 14:57:05 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/01/2024 14:56:42 18/01/2024 14:57:11 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 14:56:42 18/01/2024 14:58:23 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 14:56:42 18/01/2024 14:58:29 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/01/2024 14:56:42 18/01/2024 14:58:34 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 14:56:42 18/01/2024 14:58:41 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 18/01/2024 14:56:42 18/01/2024 14:58:46 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 18/01/2024 14:56:42 18/01/2024 14:58:52 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 18/01/2024 14:53:10 18/01/2024 14:53:17 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 18/01/2024 14:53:10 18/01/2024 14:53:22 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 18/01/2024 14:53:10 18/01/2024 14:55:11 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 18/01/2024 14:53:10 18/01/2024 14:55:17 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 18/01/2024 06:27:08 18/01/2024 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/01/2024 06:27:05 17/01/2024 06:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/01/2024 06:27:16 16/01/2024 06:27:16 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/01/2024 06:27:31 15/01/2024 06:27:31 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/01/2024 06:27:05 14/01/2024 06:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/01/2024 06:26:33 13/01/2024 06:26:33 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/01/2024 06:26:35 12/01/2024 06:26:35 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/01/2024 06:26:37 11/01/2024 06:26:37 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/01/2024 06:27:10 10/01/2024 06:27:10 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/01/2024 06:26:54 09/01/2024 06:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/01/2024 06:26:59 08/01/2024 06:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/01/2024 06:26:45 07/01/2024 06:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/01/2024 06:26:45 06/01/2024 06:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/01/2024 06:26:46 05/01/2024 06:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/01/2024 06:27:10 04/01/2024 06:27:10 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/01/2024 11:25:40 03/01/2024 11:25:40 44139966 44139966 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 03/01/2024 06:26:56 03/01/2024 06:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/01/2024 16:42:29 02/01/2024 16:42:38 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/01/2024 16:42:29 02/01/2024 16:42:56 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 02/01/2024 06:26:51 02/01/2024 06:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/01/2024 06:26:53 01/01/2024 06:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/12/2023 10:40:11 31/12/2023 10:40:21 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 31/12/2023 10:40:11 31/12/2023 10:41:16 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 31/12/2023 06:27:01 31/12/2023 06:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/12/2023 06:26:55 30/12/2023 06:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/12/2023 15:20:58 29/12/2023 15:21:05 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 29/12/2023 15:20:58 29/12/2023 15:21:25 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 29/12/2023 06:26:57 29/12/2023 06:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/12/2023 06:26:58 28/12/2023 06:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/12/2023 06:27:25 27/12/2023 06:27:25 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/12/2023 06:27:02 26/12/2023 06:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/12/2023 06:27:04 25/12/2023 06:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/12/2023 06:27:05 24/12/2023 06:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/12/2023 07:28:07 23/12/2023 07:28:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/12/2023 07:28:42 22/12/2023 07:28:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/12/2023 06:26:34 22/12/2023 06:26:34 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/12/2023 21:50:53 21/12/2023 19:49:35 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/12/2023 20:49:24 21/12/2023 19:50:03 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/12/2023 06:27:49 21/12/2023 06:27:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/12/2023 06:27:01 20/12/2023 06:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/12/2023 06:26:38 19/12/2023 06:26:38 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/12/2023 10:25:35 18/12/2023 10:25:42 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/12/2023 10:25:35 18/12/2023 10:26:24 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/12/2023 06:29:25 18/12/2023 06:29:25 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/12/2023 06:26:50 17/12/2023 06:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/12/2023 06:28:29 16/12/2023 06:28:29 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/12/2023 06:26:59 15/12/2023 06:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/12/2023 06:26:46 14/12/2023 06:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/12/2023 06:27:00 13/12/2023 06:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/12/2023 06:26:50 12/12/2023 06:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/12/2023 06:26:52 11/12/2023 06:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/12/2023 06:26:53 10/12/2023 06:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/12/2023 17:28:52 09/12/2023 17:29:24 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 09/12/2023 17:28:52 09/12/2023 17:29:35 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 09/12/2023 17:28:51 09/12/2023 17:29:00 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 09/12/2023 06:26:55 09/12/2023 06:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/12/2023 06:26:56 08/12/2023 06:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/12/2023 06:26:58 07/12/2023 06:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/12/2023 06:27:10 06/12/2023 06:27:10 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/12/2023 06:29:03 05/12/2023 06:29:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/12/2023 06:27:08 04/12/2023 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/12/2023 06:27:05 03/12/2023 06:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/12/2023 06:26:46 02/12/2023 06:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/12/2023 06:28:08 01/12/2023 06:28:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/12/2023 06:26:58 01/12/2023 06:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/11/2023 06:26:36 30/11/2023 06:26:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/11/2023 18:14:42 29/11/2023 18:14:47 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 29/11/2023 18:14:42 29/11/2023 18:14:52 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 29/11/2023 18:14:42 29/11/2023 18:14:58 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 29/11/2023 18:14:42 29/11/2023 18:15:03 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 29/11/2023 06:26:49 29/11/2023 06:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/11/2023 06:27:01 28/11/2023 06:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/11/2023 06:26:46 27/11/2023 06:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/11/2023 06:26:56 26/11/2023 06:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/11/2023 06:26:45 25/11/2023 06:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/11/2023 06:26:47 24/11/2023 06:26:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/11/2023 06:26:54 23/11/2023 06:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/11/2023 06:26:59 22/11/2023 06:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/11/2023 10:51:10 21/11/2023 10:51:10 44139966 44139966 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 21/11/2023 06:27:01 21/11/2023 06:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/11/2023 06:26:52 20/11/2023 06:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/11/2023 06:26:54 19/11/2023 06:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/11/2023 06:27:01 18/11/2023 06:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/11/2023 06:26:57 17/11/2023 06:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/11/2023 06:27:08 16/11/2023 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/11/2023 06:27:09 15/11/2023 06:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/11/2023 06:27:01 14/11/2023 06:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/11/2023 06:29:20 13/11/2023 06:29:20 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/11/2023 06:27:13 12/11/2023 06:27:13 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/11/2023 06:27:27 11/11/2023 06:27:27 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/11/2023 06:27:29 10/11/2023 06:27:29 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/11/2023 06:27:32 09/11/2023 06:27:32 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/11/2023 06:27:31 08/11/2023 06:27:31 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/11/2023 06:27:42 07/11/2023 06:27:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/11/2023 06:27:44 06/11/2023 06:27:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/11/2023 06:27:41 05/11/2023 06:27:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/11/2023 14:30:19 04/11/2023 14:30:28 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 04/11/2023 14:30:19 04/11/2023 14:30:33 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 04/11/2023 14:30:19 04/11/2023 14:30:38 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 04/11/2023 06:27:38 04/11/2023 06:27:38 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/11/2023 06:27:40 03/11/2023 06:27:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/11/2023 06:27:51 02/11/2023 06:27:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/11/2023 06:27:51 01/11/2023 06:27:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/10/2023 06:28:05 31/10/2023 06:28:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/10/2023 06:29:47 30/10/2023 06:29:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/10/2023 07:27:48 29/10/2023 07:27:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/10/2023 07:27:48 28/10/2023 07:27:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/10/2023 13:02:38 27/10/2023 13:03:15 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/10/2023 07:27:52 27/10/2023 07:27:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/10/2023 07:27:52 26/10/2023 07:27:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/10/2023 07:28:13 25/10/2023 07:28:13 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/10/2023 07:28:03 24/10/2023 07:28:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/10/2023 07:27:56 23/10/2023 07:27:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/10/2023 07:28:06 22/10/2023 07:28:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/10/2023 07:28:00 21/10/2023 07:28:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/10/2023 07:28:01 20/10/2023 07:28:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/10/2023 07:28:03 19/10/2023 07:28:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/10/2023 07:27:54 19/10/2023 07:27:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/10/2023 18:32:10 18/10/2023 16:32:32 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 18/10/2023 18:30:34 18/10/2023 16:30:47 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 18/10/2023 07:27:53 18/10/2023 07:27:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/10/2023 07:27:54 17/10/2023 07:27:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/10/2023 07:28:05 16/10/2023 07:28:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/10/2023 07:27:58 15/10/2023 07:27:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/10/2023 07:27:59 14/10/2023 07:27:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/10/2023 07:28:00 13/10/2023 07:28:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/10/2023 14:44:29 12/10/2023 14:44:29 44139966 44139966 1,0 102 Temporary Fault Test Alarm (TAT)
KRM_SERVER 12/10/2023 07:28:21 12/10/2023 07:28:21 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/10/2023 07:26:48 12/10/2023 07:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/10/2023 23:56:58 11/10/2023 21:57:25 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 11/10/2023 23:56:39 11/10/2023 21:57:11 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 11/10/2023 23:56:35 11/10/2023 21:56:57 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 11/10/2023 23:56:00 11/10/2023 21:56:22 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 11/10/2023 23:01:41 11/10/2023 21:00:58 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 11/10/2023 23:01:36 11/10/2023 21:00:46 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 11/10/2023 23:00:54 11/10/2023 21:00:03 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 11/10/2023 23:00:48 11/10/2023 21:01:27 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 11/10/2023 10:25:25 11/10/2023 10:25:33 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/10/2023 10:25:25 11/10/2023 10:33:26 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/10/2023 07:26:50 11/10/2023 07:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/10/2023 07:26:59 10/10/2023 07:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/10/2023 07:26:55 09/10/2023 07:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/10/2023 07:26:53 08/10/2023 07:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/10/2023 07:29:20 07/10/2023 07:29:20 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/10/2023 07:26:57 06/10/2023 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/10/2023 07:27:08 05/10/2023 07:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/10/2023 07:27:02 04/10/2023 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/10/2023 07:27:01 03/10/2023 07:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/10/2023 07:27:03 02/10/2023 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/10/2023 07:27:04 01/10/2023 07:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/10/2023 03:39:11 01/10/2023 03:39:21 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 01/10/2023 03:39:11 01/10/2023 03:39:33 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 30/09/2023 07:27:05 30/09/2023 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/09/2023 07:26:37 29/09/2023 07:26:37 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/09/2023 07:26:38 28/09/2023 07:26:38 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/09/2023 17:19:05 27/09/2023 17:19:15 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/09/2023 17:19:05 27/09/2023 17:19:51 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 27/09/2023 07:26:42 27/09/2023 07:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/09/2023 07:27:26 26/09/2023 07:27:26 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/09/2023 07:26:45 25/09/2023 07:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/09/2023 07:27:20 24/09/2023 07:27:20 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/09/2023 07:26:45 23/09/2023 07:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/09/2023 07:26:48 22/09/2023 07:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/09/2023 07:27:26 21/09/2023 07:27:26 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/09/2023 07:26:50 20/09/2023 07:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/09/2023 07:27:00 19/09/2023 07:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/09/2023 22:21:10 18/09/2023 22:21:15 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 18/09/2023 22:21:10 18/09/2023 22:21:22 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 18/09/2023 22:21:10 18/09/2023 22:21:27 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 18/09/2023 22:21:10 18/09/2023 22:21:33 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 18/09/2023 22:10:29 18/09/2023 22:10:34 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/09/2023 22:10:29 18/09/2023 22:21:01 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 18/09/2023 07:27:01 18/09/2023 07:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/09/2023 20:43:38 17/09/2023 20:43:43 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/09/2023 20:43:38 17/09/2023 20:43:55 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/09/2023 07:26:54 17/09/2023 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/09/2023 22:15:18 16/09/2023 22:15:23 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 16/09/2023 22:15:18 16/09/2023 23:06:27 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 16/09/2023 07:27:05 16/09/2023 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/09/2023 07:26:56 15/09/2023 07:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/09/2023 20:15:55 14/09/2023 20:16:00 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 14/09/2023 20:15:55 14/09/2023 20:16:24 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 14/09/2023 08:32:21 14/09/2023 08:32:32 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 14/09/2023 08:32:21 14/09/2023 08:32:50 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 14/09/2023 07:27:01 14/09/2023 07:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/09/2023 07:27:08 13/09/2023 07:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/09/2023 07:27:05 12/09/2023 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/09/2023 07:27:11 11/09/2023 07:27:11 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/09/2023 07:27:04 10/09/2023 07:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/09/2023 07:27:06 09/09/2023 07:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/09/2023 07:28:45 08/09/2023 07:28:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/09/2023 07:28:43 07/09/2023 07:28:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/09/2023 07:28:33 06/09/2023 07:28:33 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/09/2023 07:28:44 05/09/2023 07:28:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/09/2023 07:28:36 04/09/2023 07:28:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/09/2023 07:28:45 03/09/2023 07:28:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/09/2023 07:28:57 02/09/2023 07:28:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/09/2023 15:51:18 01/09/2023 15:51:18 44139966 44139966 1,0 102 Temporary Fault Test Alarm
KRM_SERVER 01/09/2023 07:28:40 01/09/2023 07:28:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/08/2023 07:29:03 31/08/2023 07:29:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/08/2023 07:28:42 30/08/2023 07:28:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/08/2023 07:29:00 29/08/2023 07:29:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/08/2023 07:29:27 28/08/2023 07:29:27 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/08/2023 07:28:53 27/08/2023 07:28:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/08/2023 07:28:49 26/08/2023 07:28:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/08/2023 07:28:51 25/08/2023 07:28:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/08/2023 07:28:52 24/08/2023 07:28:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/08/2023 07:28:52 23/08/2023 07:28:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/08/2023 07:29:11 22/08/2023 07:29:11 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/08/2023 11:07:29 21/08/2023 09:07:59 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/08/2023 11:07:08 21/08/2023 09:07:43 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/08/2023 11:07:04 21/08/2023 09:07:31 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 21/08/2023 11:06:32 21/08/2023 09:06:58 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 21/08/2023 07:30:01 21/08/2023 07:30:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/08/2023 07:27:45 21/08/2023 07:27:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/08/2023 09:34:59 20/08/2023 07:33:45 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 20/08/2023 09:34:58 20/08/2023 07:33:31 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 20/08/2023 09:34:51 20/08/2023 07:35:22 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 20/08/2023 09:34:06 20/08/2023 07:35:08 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 20/08/2023 09:34:04 20/08/2023 07:34:55 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 20/08/2023 09:33:59 20/08/2023 07:34:27 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 20/08/2023 09:33:38 20/08/2023 07:34:06 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 20/08/2023 09:29:53 20/08/2023 07:28:26 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 20/08/2023 07:27:03 20/08/2023 07:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/08/2023 07:27:06 19/08/2023 07:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/08/2023 07:26:46 18/08/2023 07:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/08/2023 07:28:04 17/08/2023 07:28:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/08/2023 07:26:38 17/08/2023 07:27:16 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/08/2023 06:35:54 17/08/2023 06:36:06 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 17/08/2023 06:35:54 17/08/2023 06:37:41 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 16/08/2023 07:26:47 16/08/2023 07:26:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/08/2023 07:26:50 15/08/2023 07:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/08/2023 07:26:43 14/08/2023 07:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/08/2023 07:26:43 13/08/2023 07:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/08/2023 07:26:56 12/08/2023 07:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/08/2023 07:27:16 11/08/2023 07:27:16 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/08/2023 07:27:33 10/08/2023 07:27:33 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/08/2023 17:52:52 09/08/2023 17:53:03 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 09/08/2023 17:52:52 09/08/2023 17:53:09 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 09/08/2023 17:52:52 09/08/2023 17:53:21 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 09/08/2023 07:26:50 09/08/2023 07:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/08/2023 07:27:05 08/08/2023 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/08/2023 07:26:57 07/08/2023 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/08/2023 07:27:03 06/08/2023 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/08/2023 07:27:07 05/08/2023 07:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/08/2023 07:26:57 04/08/2023 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/08/2023 07:29:37 03/08/2023 07:29:37 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/08/2023 07:27:00 02/08/2023 07:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/08/2023 07:27:18 01/08/2023 07:27:18 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/07/2023 07:27:03 31/07/2023 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/07/2023 17:49:22 30/07/2023 17:49:33 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/07/2023 17:49:22 30/07/2023 17:50:40 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/07/2023 15:25:56 30/07/2023 15:26:06 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/07/2023 15:25:56 30/07/2023 15:27:32 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/07/2023 15:22:22 30/07/2023 15:22:32 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/07/2023 15:22:22 30/07/2023 15:23:42 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/07/2023 07:27:17 30/07/2023 07:27:17 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/07/2023 12:01:16 29/07/2023 12:01:30 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 29/07/2023 12:01:16 29/07/2023 12:02:23 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 29/07/2023 07:27:06 29/07/2023 07:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/07/2023 07:26:36 28/07/2023 07:26:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/07/2023 07:27:07 27/07/2023 07:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/07/2023 07:26:39 26/07/2023 07:26:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/07/2023 07:26:56 25/07/2023 07:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/07/2023 07:26:51 24/07/2023 07:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/07/2023 07:26:51 23/07/2023 07:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/07/2023 07:26:53 22/07/2023 07:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/07/2023 08:25:06 21/07/2023 08:25:23 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/07/2023 08:25:06 21/07/2023 08:28:20 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 21/07/2023 08:03:27 21/07/2023 08:03:44 44139966 44139966 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 21/07/2023 08:03:27 21/07/2023 08:03:55 44139966 44139966 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 21/07/2023 08:03:27 21/07/2023 08:04:00 44139966 44139966 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 21/07/2023 08:03:27 21/07/2023 08:04:06 44139966 44139966 1,0 1011 Elevator Failure Car door contact opened during drive (C5)
KRM_SERVER 21/07/2023 07:26:47 21/07/2023 07:26:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/07/2023 16:15:19 20/07/2023 16:15:19 44139966 44139966 1,0 102 Test Alarm Test Alarm (TAT)
KRM_SERVER 20/07/2023 07:27:19 20/07/2023 07:27:19 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/07/2023 07:26:49 19/07/2023 07:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/07/2023 07:27:04 18/07/2023 07:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/07/2023 07:27:13 17/07/2023 07:27:14 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/07/2023 07:26:54 16/07/2023 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/07/2023 07:26:55 15/07/2023 07:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/07/2023 07:27:10 14/07/2023 07:27:10 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/07/2023 07:28:59 13/07/2023 07:28:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/07/2023 07:27:00 12/07/2023 12:00:38 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/07/2023 19:10:40 11/07/2023 19:10:45 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/07/2023 19:10:40 11/07/2023 19:11:32 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/07/2023 07:27:10 11/07/2023 07:27:10 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/07/2023 13:07:05 09/07/2023 13:07:09 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/07/2023 13:07:05 09/07/2023 13:07:18 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/07/2023 07:27:09 09/07/2023 07:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/07/2023 07:27:15 09/07/2023 08:37:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/07/2023 07:26:46 07/07/2023 07:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/07/2023 09:34:20 04/07/2023 09:34:25 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 04/07/2023 09:34:20 04/07/2023 09:36:15 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 04/07/2023 07:26:51 04/07/2023 07:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/07/2023 07:26:51 04/07/2023 11:13:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/07/2023 07:26:44 02/07/2023 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/07/2023 07:26:54 01/07/2023 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/06/2023 07:26:57 29/06/2023 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/06/2023 07:27:27 28/06/2023 07:27:27 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/06/2023 07:26:52 27/06/2023 07:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/06/2023 07:27:05 26/06/2023 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/06/2023 07:26:54 25/06/2023 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/06/2023 07:26:58 23/06/2023 07:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/06/2023 07:27:13 22/06/2023 07:27:13 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/06/2023 07:27:02 20/06/2023 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/06/2023 07:29:13 19/06/2023 07:29:13 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/06/2023 07:29:06 18/06/2023 07:29:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/06/2023 07:27:32 17/06/2023 07:27:32 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/06/2023 06:29:10 16/06/2023 06:29:11 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/06/2023 06:29:47 15/06/2023 06:29:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/06/2023 06:29:16 14/06/2023 06:29:16 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/06/2023 06:29:15 13/06/2023 06:29:15 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/06/2023 06:29:08 12/06/2023 06:29:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/06/2023 06:29:10 11/06/2023 06:29:10 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/06/2023 07:26:51 10/06/2023 07:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/06/2023 19:39:07 09/06/2023 19:39:13 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/06/2023 19:39:07 09/06/2023 19:40:13 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 09/06/2023 12:54:44 09/06/2023 11:03:29 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 09/06/2023 11:56:51 09/06/2023 11:03:13 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 09/06/2023 11:56:48 09/06/2023 11:02:59 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 09/06/2023 11:55:33 09/06/2023 11:02:45 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 09/06/2023 10:54:44 09/06/2023 10:54:53 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/06/2023 10:54:44 09/06/2023 10:54:58 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/06/2023 10:54:44 09/06/2023 10:55:09 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/06/2023 10:54:44 09/06/2023 10:55:16 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/06/2023 10:52:15 09/06/2023 11:01:49 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 09/06/2023 10:52:15 09/06/2023 11:02:17 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 09/06/2023 10:52:14 09/06/2023 11:01:35 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 09/06/2023 10:52:14 09/06/2023 11:02:03 44139966 44139966 1,0 1008 Elevator Failure Safety circuit: Safety gear (C2)
KRM_SERVER 09/06/2023 10:50:19 09/06/2023 10:50:19 44139966 44139966 1,0 102 Test alarm Test Alarm (TAT)
KRM_SERVER 09/06/2023 10:48:52 09/06/2023 10:51:58 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 09/06/2023 10:48:52 09/06/2023 10:52:12 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 09/06/2023 10:48:52 09/06/2023 10:52:26 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/06/2023 10:48:52 09/06/2023 10:52:40 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 09/06/2023 10:48:52 09/06/2023 10:53:07 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 09/06/2023 10:48:52 09/06/2023 10:53:21 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/06/2023 10:48:52 09/06/2023 10:56:22 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/06/2023 10:48:52 09/06/2023 10:57:18 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 09/06/2023 10:48:52 09/06/2023 10:57:46 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 09/06/2023 10:48:52 09/06/2023 10:58:14 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/06/2023 10:48:52 09/06/2023 11:00:10 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 09/06/2023 10:48:52 09/06/2023 11:00:25 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 09/06/2023 10:48:33 09/06/2023 10:53:49 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 09/06/2023 10:48:33 09/06/2023 10:54:03 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 09/06/2023 10:48:33 09/06/2023 10:54:17 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/06/2023 10:48:33 09/06/2023 10:54:31 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 09/06/2023 10:48:33 09/06/2023 10:54:45 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 09/06/2023 10:48:33 09/06/2023 10:54:58 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 09/06/2023 10:38:51 09/06/2023 10:38:56 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 09/06/2023 10:38:51 09/06/2023 10:39:01 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 09/06/2023 10:38:51 09/06/2023 10:45:16 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 09/06/2023 10:38:51 09/06/2023 10:45:21 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 09/06/2023 07:26:53 09/06/2023 07:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/06/2023 07:27:27 08/06/2023 07:27:27 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/06/2023 07:26:48 07/06/2023 07:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/06/2023 07:27:02 06/06/2023 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/06/2023 07:26:51 05/06/2023 07:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/06/2023 07:26:56 04/06/2023 07:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/06/2023 07:29:15 03/06/2023 07:29:15 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/06/2023 07:27:05 02/06/2023 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/06/2023 10:40:23 01/06/2023 10:40:23 44139966 44139966 1,0 102 Test alarm Test Alarm (TAT)
KRM_SERVER 01/06/2023 07:27:07 01/06/2023 07:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/05/2023 07:26:58 31/05/2023 07:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/05/2023 07:27:00 30/05/2023 07:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/05/2023 07:27:02 29/05/2023 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/05/2023 07:27:12 28/05/2023 07:27:13 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/05/2023 07:27:13 27/05/2023 07:27:13 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/05/2023 07:26:35 26/05/2023 07:26:35 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/05/2023 07:26:52 25/05/2023 07:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/05/2023 07:26:56 24/05/2023 07:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/05/2023 09:54:40 23/05/2023 09:54:45 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/05/2023 09:54:40 23/05/2023 09:55:11 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/05/2023 07:26:49 23/05/2023 07:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/05/2023 07:26:40 22/05/2023 07:26:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/05/2023 07:26:57 21/05/2023 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/05/2023 07:26:44 20/05/2023 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/05/2023 12:00:04 19/05/2023 12:00:09 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 19/05/2023 12:00:04 19/05/2023 12:00:35 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 19/05/2023 09:33:58 19/05/2023 09:34:03 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 19/05/2023 09:33:58 19/05/2023 09:34:24 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 19/05/2023 09:07:26 19/05/2023 09:07:31 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 19/05/2023 09:07:26 19/05/2023 09:07:48 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 19/05/2023 07:26:45 19/05/2023 07:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/05/2023 07:26:59 18/05/2023 07:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/05/2023 07:26:59 17/05/2023 07:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/05/2023 07:26:59 16/05/2023 07:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/05/2023 07:27:28 15/05/2023 07:27:28 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/05/2023 07:26:53 14/05/2023 07:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/05/2023 07:26:57 12/05/2023 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/05/2023 07:31:02 11/05/2023 07:31:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/05/2023 07:28:12 11/05/2023 07:28:12 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/05/2023 07:27:02 11/05/2023 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/05/2023 07:27:00 10/05/2023 07:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/05/2023 07:28:46 09/05/2023 07:28:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/05/2023 07:27:09 09/05/2023 07:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/05/2023 07:28:27 08/05/2023 07:28:27 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/05/2023 07:27:03 08/05/2023 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/05/2023 07:27:27 07/05/2023 07:27:27 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/05/2023 07:27:06 06/05/2023 07:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/05/2023 07:26:57 05/05/2023 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/05/2023 07:26:44 04/05/2023 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/05/2023 07:27:54 03/05/2023 07:27:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/05/2023 07:27:14 02/05/2023 07:27:14 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/05/2023 07:26:48 01/05/2023 07:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/04/2023 07:27:05 30/04/2023 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/04/2023 14:21:44 29/04/2023 14:21:49 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 29/04/2023 14:21:44 29/04/2023 14:21:59 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 29/04/2023 07:26:46 29/04/2023 07:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/04/2023 07:26:44 28/04/2023 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/04/2023 07:26:55 27/04/2023 07:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/04/2023 07:26:48 26/04/2023 07:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/04/2023 07:26:51 25/04/2023 07:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/04/2023 11:19:32 24/04/2023 11:19:37 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/04/2023 11:19:32 24/04/2023 11:20:28 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 24/04/2023 07:26:50 24/04/2023 07:26:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/04/2023 07:26:57 23/04/2023 07:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/04/2023 20:13:13 22/04/2023 20:13:18 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 22/04/2023 20:13:13 22/04/2023 20:13:32 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 22/04/2023 07:26:54 22/04/2023 07:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/04/2023 10:34:29 21/04/2023 10:34:29 44139966 44139966 1,0 102 Test alarm Test Alarm (TAT)
KRM_SERVER 21/04/2023 07:27:06 21/04/2023 07:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/04/2023 07:27:43 20/04/2023 07:27:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/04/2023 07:27:06 19/04/2023 07:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/04/2023 07:27:14 18/04/2023 07:27:14 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/04/2023 07:27:19 17/04/2023 07:27:19 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/04/2023 07:27:03 16/04/2023 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/04/2023 07:27:26 15/04/2023 07:27:26 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/04/2023 20:31:03 14/04/2023 20:31:13 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 14/04/2023 20:31:03 14/04/2023 20:31:24 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 14/04/2023 07:27:03 14/04/2023 07:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/04/2023 07:26:36 13/04/2023 07:26:36 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/04/2023 13:21:26 12/04/2023 13:21:32 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/04/2023 13:21:26 12/04/2023 13:23:14 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/04/2023 13:10:58 12/04/2023 13:11:04 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/04/2023 13:10:58 12/04/2023 13:14:37 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/04/2023 13:07:38 12/04/2023 13:07:44 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/04/2023 13:07:38 12/04/2023 13:08:43 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 12/04/2023 07:26:50 12/04/2023 07:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/04/2023 07:28:40 11/04/2023 07:28:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/04/2023 07:26:51 10/04/2023 07:26:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/04/2023 07:26:44 09/04/2023 07:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/04/2023 07:26:42 08/04/2023 07:26:42 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/04/2023 07:26:53 07/04/2023 07:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/04/2023 07:26:46 06/04/2023 07:26:46 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/04/2023 07:26:47 05/04/2023 07:26:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/04/2023 07:26:49 04/04/2023 07:26:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/04/2023 07:29:04 03/04/2023 07:29:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/04/2023 07:27:23 02/04/2023 07:27:23 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/04/2023 07:27:05 01/04/2023 07:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/03/2023 07:26:55 31/03/2023 07:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/03/2023 07:28:48 30/03/2023 07:48:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/03/2023 07:27:05 30/03/2023 07:39:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/03/2023 07:27:13 29/03/2023 07:27:13 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/03/2023 07:27:17 28/03/2023 07:27:17 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/03/2023 07:27:02 27/03/2023 07:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/03/2023 06:27:12 26/03/2023 06:27:12 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/03/2023 06:27:24 25/03/2023 06:27:24 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/03/2023 06:26:54 24/03/2023 06:26:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/03/2023 21:49:44 23/03/2023 21:49:49 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/03/2023 21:49:44 23/03/2023 21:51:45 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/03/2023 21:44:51 23/03/2023 21:44:56 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/03/2023 21:44:51 23/03/2023 21:47:11 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 23/03/2023 06:27:01 23/03/2023 06:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/03/2023 06:26:58 22/03/2023 06:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/03/2023 06:27:08 21/03/2023 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/03/2023 06:28:37 20/03/2023 06:28:37 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/03/2023 06:29:04 19/03/2023 06:29:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/03/2023 06:27:04 18/03/2023 06:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/03/2023 06:27:05 17/03/2023 06:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/03/2023 06:27:44 16/03/2023 06:27:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/03/2023 06:27:43 15/03/2023 06:27:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/03/2023 06:27:19 14/03/2023 06:27:19 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/03/2023 06:27:21 13/03/2023 06:27:21 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/03/2023 06:27:13 12/03/2023 06:27:13 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/03/2023 06:27:59 11/03/2023 06:27:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/03/2023 13:00:36 10/03/2023 13:00:41 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/03/2023 13:00:36 10/03/2023 13:00:58 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/03/2023 12:57:47 10/03/2023 12:57:52 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/03/2023 12:57:47 10/03/2023 12:58:06 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 10/03/2023 06:27:54 10/03/2023 06:27:54 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/03/2023 06:27:50 09/03/2023 06:27:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/03/2023 06:27:29 08/03/2023 06:27:29 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/03/2023 06:26:58 08/03/2023 06:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/03/2023 16:38:23 07/03/2023 15:38:09 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 07/03/2023 16:38:22 07/03/2023 15:38:29 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 07/03/2023 16:38:19 07/03/2023 15:38:04 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 07/03/2023 16:31:32 07/03/2023 15:31:17 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 07/03/2023 15:40:46 07/03/2023 15:40:46 44139966 44139966 1,0 102 Test alarm Test Alarm (TAT)
KRM_SERVER 07/03/2023 15:38:18 07/03/2023 15:38:23 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 07/03/2023 15:38:18 07/03/2023 15:38:29 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 07/03/2023 15:38:18 07/03/2023 15:38:34 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 07/03/2023 15:38:18 07/03/2023 15:38:40 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 07/03/2023 15:30:49 07/03/2023 15:31:11 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 07/03/2023 15:30:17 07/03/2023 15:30:37 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 07/03/2023 15:30:17 07/03/2023 15:30:42 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 07/03/2023 15:30:17 07/03/2023 15:30:48 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 07/03/2023 15:30:16 07/03/2023 15:30:21 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 07/03/2023 15:30:16 07/03/2023 15:30:26 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 07/03/2023 15:30:16 07/03/2023 15:30:32 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 07/03/2023 15:30:16 07/03/2023 15:31:05 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 07/03/2023 06:27:20 07/03/2023 06:27:20 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/03/2023 06:27:10 06/03/2023 06:27:10 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/03/2023 06:27:03 05/03/2023 06:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/03/2023 06:27:05 04/03/2023 06:27:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/03/2023 07:31:45 03/03/2023 07:31:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/03/2023 07:31:46 02/03/2023 07:31:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/03/2023 07:31:56 01/03/2023 07:31:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/02/2023 07:31:49 28/02/2023 07:31:49 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/02/2023 07:31:52 27/02/2023 07:31:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/02/2023 07:32:06 26/02/2023 07:32:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/02/2023 07:32:06 25/02/2023 07:32:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/02/2023 07:32:09 23/02/2023 07:32:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/02/2023 07:32:08 22/02/2023 07:32:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/02/2023 07:31:51 22/02/2023 07:31:51 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/02/2023 12:56:36 21/02/2023 11:56:57 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/02/2023 12:56:17 21/02/2023 11:56:40 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/02/2023 12:56:09 21/02/2023 11:56:27 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 21/02/2023 12:55:48 21/02/2023 11:56:06 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 21/02/2023 12:47:57 21/02/2023 11:48:25 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/02/2023 12:47:52 21/02/2023 11:48:11 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/02/2023 12:42:32 21/02/2023 11:42:49 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/02/2023 12:42:07 21/02/2023 11:42:37 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/02/2023 12:42:05 21/02/2023 11:42:24 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 21/02/2023 12:41:15 21/02/2023 11:41:34 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 21/02/2023 12:23:47 21/02/2023 11:24:13 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/02/2023 12:23:42 21/02/2023 11:24:01 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/02/2023 12:20:27 21/02/2023 11:20:47 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/02/2023 12:20:02 21/02/2023 11:20:33 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/02/2023 12:20:01 21/02/2023 11:20:20 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 21/02/2023 12:19:33 21/02/2023 11:19:51 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 21/02/2023 12:18:32 21/02/2023 11:18:54 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/02/2023 12:18:11 21/02/2023 11:18:41 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/02/2023 12:18:07 21/02/2023 11:18:27 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 21/02/2023 12:17:07 21/02/2023 11:17:27 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 21/02/2023 12:02:25 21/02/2023 12:02:25 44139966 44139966 1,0 102 Test Alarm Test Alarm
KRM_SERVER 21/02/2023 11:59:57 21/02/2023 12:00:08 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:59:57 21/02/2023 12:00:13 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 11:59:57 21/02/2023 12:00:19 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 11:59:57 21/02/2023 12:00:25 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:59:57 21/02/2023 12:00:30 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 11:59:57 21/02/2023 12:00:36 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 11:59:57 21/02/2023 12:00:41 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:59:57 21/02/2023 12:00:47 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 11:58:38 21/02/2023 11:58:44 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:58:38 21/02/2023 11:58:50 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 11:58:38 21/02/2023 11:58:55 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 11:58:38 21/02/2023 11:59:01 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:58:38 21/02/2023 11:59:06 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 11:58:38 21/02/2023 11:59:12 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 11:58:38 21/02/2023 11:59:23 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 11:58:38 21/02/2023 11:59:29 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 11:58:38 21/02/2023 11:59:34 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 11:58:38 21/02/2023 11:59:40 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 11:58:38 21/02/2023 11:59:45 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:58:38 21/02/2023 11:59:51 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:56:30 21/02/2023 11:56:40 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:56:30 21/02/2023 11:56:46 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:56:30 21/02/2023 11:56:51 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:56:30 21/02/2023 11:56:57 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:55:34 21/02/2023 11:55:40 44139966 44139966 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 21/02/2023 11:55:34 21/02/2023 11:55:45 44139966 44139966 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 21/02/2023 11:55:13 21/02/2023 11:55:24 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:55:13 21/02/2023 11:55:29 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:44:41 21/02/2023 10:45:09 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/02/2023 11:44:35 21/02/2023 10:44:54 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 21/02/2023 11:44:30 21/02/2023 10:44:41 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 21/02/2023 11:42:59 21/02/2023 11:43:39 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:42:59 21/02/2023 11:43:55 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:42:59 21/02/2023 11:44:34 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:42:59 21/02/2023 11:44:40 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:42:29 21/02/2023 11:42:37 44139966 44139966 1,0 1182 Elevator Failure KCEMSC configuration failure - DIP position changed
KRM_SERVER 21/02/2023 11:42:29 21/02/2023 11:42:55 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:42:29 21/02/2023 11:43:00 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:42:29 21/02/2023 11:43:11 44139966 44139966 1,0 1182 Elevator Failure KCEMSC configuration failure - DIP position changed
KRM_SERVER 21/02/2023 11:42:29 21/02/2023 11:43:50 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:42:29 21/02/2023 11:44:07 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 11:42:29 21/02/2023 11:45:15 44139966 44139966 1,0 1182 Elevator Failure KCEMSC configuration failure - DIP position changed
KRM_SERVER 21/02/2023 11:42:29 21/02/2023 11:45:21 44139966 44139966 1,0 1182 Elevator Failure KCEMSC configuration failure - DIP position changed
KRM_SERVER 21/02/2023 11:31:45 21/02/2023 11:31:51 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 21/02/2023 11:31:45 21/02/2023 11:32:09 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 21/02/2023 11:31:45 21/02/2023 11:32:21 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 21/02/2023 11:31:45 21/02/2023 11:32:32 44139966 44139966 1,0 1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
KRM_SERVER 21/02/2023 11:18:31 21/02/2023 11:18:41 44139966 44139966 1,0 1165 Elevator Failure KCEMSC configuration failure - DIP 6
KRM_SERVER 21/02/2023 11:18:31 21/02/2023 11:18:47 44139966 44139966 1,0 1165 Elevator Failure KCEMSC configuration failure - DIP 6
KRM_SERVER 21/02/2023 11:15:40 21/02/2023 11:15:47 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 21/02/2023 11:15:40 21/02/2023 11:16:04 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 21/02/2023 11:15:40 21/02/2023 11:16:22 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 21/02/2023 11:08:18 21/02/2023 11:08:29 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 21/02/2023 11:08:18 21/02/2023 11:09:14 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 21/02/2023 11:08:17 21/02/2023 11:08:24 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 21/02/2023 11:08:17 21/02/2023 11:09:08 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 21/02/2023 11:05:53 21/02/2023 11:06:25 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 21/02/2023 11:05:53 21/02/2023 11:06:49 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 21/02/2023 11:05:52 21/02/2023 11:06:19 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 21/02/2023 11:05:52 21/02/2023 11:06:43 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 21/02/2023 11:05:21 21/02/2023 11:05:29 44139966 44139966 1,0 1106 Elevator Failure Setup failed
KRM_SERVER 21/02/2023 11:05:21 21/02/2023 11:05:35 44139966 44139966 1,0 1106 Elevator Failure Setup failed
KRM_SERVER 21/02/2023 11:04:09 21/02/2023 10:04:20 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 21/02/2023 11:03:10 21/02/2023 11:03:40 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 11:03:10 21/02/2023 11:03:46 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 11:03:10 21/02/2023 11:03:52 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 11:03:10 21/02/2023 11:04:53 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 11:03:10 21/02/2023 11:05:05 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 11:03:10 21/02/2023 11:05:11 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 10:59:54 21/02/2023 11:00:34 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 10:59:54 21/02/2023 11:00:39 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:59:54 21/02/2023 11:00:45 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 10:59:54 21/02/2023 11:03:18 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 10:59:54 21/02/2023 11:03:24 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:59:54 21/02/2023 11:03:29 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 10:54:05 21/02/2023 10:54:20 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:54:05 21/02/2023 10:54:25 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:54:05 21/02/2023 11:00:05 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:54:05 21/02/2023 11:00:23 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:53:19 21/02/2023 10:53:25 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 21/02/2023 10:53:19 21/02/2023 10:53:31 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 21/02/2023 10:53:19 21/02/2023 10:55:04 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 21/02/2023 10:53:19 21/02/2023 10:55:09 44139966 44139966 1,0 1029 Elevator Failure Safety circuit: Pit safety contact open (H1)
KRM_SERVER 21/02/2023 10:50:15 21/02/2023 10:51:51 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:50:15 21/02/2023 10:54:09 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:50:14 21/02/2023 10:51:28 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 10:50:14 21/02/2023 10:51:39 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 10:50:14 21/02/2023 10:59:59 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 10:50:14 21/02/2023 11:00:17 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 10:50:13 21/02/2023 10:50:49 44139966 44139966 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 21/02/2023 10:50:13 21/02/2023 10:50:55 44139966 44139966 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 21/02/2023 10:50:13 21/02/2023 10:51:00 44139966 44139966 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 21/02/2023 10:50:13 21/02/2023 10:51:06 44139966 44139966 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 21/02/2023 10:50:13 21/02/2023 10:51:34 44139966 44139966 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 21/02/2023 10:50:13 21/02/2023 10:51:45 44139966 44139966 1,0 1099 Elevator Failure Main stop switch open
KRM_SERVER 21/02/2023 10:50:13 21/02/2023 10:51:57 44139966 44139966 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 21/02/2023 10:50:13 21/02/2023 10:52:03 44139966 44139966 1,0 1068 Elevator Failure 24V power supply voltage out of +- 20 % range
KRM_SERVER 21/02/2023 10:50:11 21/02/2023 10:50:22 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 21/02/2023 10:50:11 21/02/2023 10:50:27 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 21/02/2023 10:50:11 21/02/2023 10:50:38 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 21/02/2023 10:50:11 21/02/2023 10:50:44 44139966 44139966 1,0 1117 Elevator Failure KMI stop switch active
KRM_SERVER 21/02/2023 10:48:44 21/02/2023 10:49:54 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:48:44 21/02/2023 10:49:59 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 10:48:44 21/02/2023 10:50:05 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:48:44 21/02/2023 10:50:16 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 10:48:44 21/02/2023 10:51:11 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:48:44 21/02/2023 10:51:17 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 10:48:44 21/02/2023 10:51:22 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 10:48:44 21/02/2023 10:54:14 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:48:25 21/02/2023 10:49:21 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:48:25 21/02/2023 10:49:37 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:48:20 21/02/2023 10:48:48 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 10:48:20 21/02/2023 10:48:53 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 21/02/2023 10:48:20 21/02/2023 10:49:15 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 21/02/2023 10:48:19 21/02/2023 10:48:29 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 10:48:19 21/02/2023 10:48:35 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 21/02/2023 10:48:19 21/02/2023 10:49:10 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 21/02/2023 10:44:44 21/02/2023 10:44:53 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 10:44:44 21/02/2023 10:44:59 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:44:44 21/02/2023 10:45:04 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 10:44:44 21/02/2023 10:45:09 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 10:44:44 21/02/2023 10:45:16 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:44:44 21/02/2023 10:45:21 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 10:44:44 21/02/2023 10:48:40 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 10:44:44 21/02/2023 10:48:59 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 21/02/2023 10:44:44 21/02/2023 10:49:04 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:44:44 21/02/2023 10:49:32 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 10:44:44 21/02/2023 10:49:43 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 21/02/2023 10:44:44 21/02/2023 10:49:48 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 21/02/2023 07:31:52 21/02/2023 07:31:52 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/02/2023 07:34:03 20/02/2023 07:34:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/02/2023 07:32:05 19/02/2023 07:32:05 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/02/2023 07:31:57 18/02/2023 07:31:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/02/2023 07:32:07 17/02/2023 07:32:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/02/2023 06:27:14 17/02/2023 06:27:14 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/02/2023 11:15:16 16/02/2023 09:10:40 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 16/02/2023 11:15:11 16/02/2023 09:10:26 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 16/02/2023 11:14:42 16/02/2023 09:09:58 44139966 44139966 1,0 4016 Elevator Failure KCEAPM 24V power failed (mains missing)
KRM_SERVER 16/02/2023 10:10:33 16/02/2023 09:11:05 44139966 44139966 1,0 4018 Elevator Failure KCEAPM has no connection to KCECPU
KRM_SERVER 16/02/2023 09:50:51 16/02/2023 09:51:26 44139966 44139966 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 16/02/2023 09:50:51 16/02/2023 09:51:43 44139966 44139966 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 16/02/2023 09:50:48 16/02/2023 09:51:09 44139966 44139966 1,0 1043 Elevator Failure Start permit fault
KRM_SERVER 16/02/2023 09:50:48 16/02/2023 09:51:37 44139966 44139966 1,0 1043 Elevator Failure Start permit fault
KRM_SERVER 16/02/2023 09:50:47 16/02/2023 09:50:59 44139966 44139966 1,0 1190 Elevator Failure Device picked input dropped while lift running
KRM_SERVER 16/02/2023 09:50:47 16/02/2023 09:51:04 44139966 44139966 1,0 1043 Elevator Failure Start permit fault
KRM_SERVER 16/02/2023 09:50:47 16/02/2023 09:51:21 44139966 44139966 1,0 1190 Elevator Failure Device picked input dropped while lift running
KRM_SERVER 16/02/2023 09:50:47 16/02/2023 09:51:32 44139966 44139966 1,0 1043 Elevator Failure Start permit fault
KRM_SERVER 16/02/2023 09:50:46 16/02/2023 09:50:53 44139966 44139966 1,0 1190 Elevator Failure Device picked input dropped while lift running
KRM_SERVER 16/02/2023 09:50:46 16/02/2023 09:51:15 44139966 44139966 1,0 1190 Elevator Failure Device picked input dropped while lift running
KRM_SERVER 16/02/2023 09:40:44 16/02/2023 09:41:14 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:37:27 16/02/2023 09:38:14 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 16/02/2023 09:37:27 16/02/2023 09:38:25 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 16/02/2023 09:37:26 16/02/2023 09:38:07 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 16/02/2023 09:37:26 16/02/2023 09:38:31 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 16/02/2023 09:33:29 16/02/2023 09:34:12 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:33:29 16/02/2023 09:34:23 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:33:29 16/02/2023 09:34:28 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:33:29 16/02/2023 09:40:46 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:30:46 16/02/2023 09:31:16 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:30:46 16/02/2023 09:31:21 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:30:46 16/02/2023 09:31:27 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:30:46 16/02/2023 09:31:33 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:30:46 16/02/2023 09:31:45 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:30:46 16/02/2023 09:31:51 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:30:46 16/02/2023 09:33:33 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:30:46 16/02/2023 09:33:39 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:30:46 16/02/2023 09:33:44 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:30:06 16/02/2023 09:32:02 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:30:06 16/02/2023 09:32:07 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:30:06 16/02/2023 09:32:13 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:30:06 16/02/2023 09:32:19 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:30:06 16/02/2023 09:32:25 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:30:06 16/02/2023 09:32:30 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:29:09 16/02/2023 09:30:31 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:29:09 16/02/2023 09:30:47 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:29:08 16/02/2023 09:29:44 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:29:08 16/02/2023 09:29:50 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:29:08 16/02/2023 09:30:01 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:29:08 16/02/2023 09:30:08 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:29:08 16/02/2023 09:30:34 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:29:08 16/02/2023 09:30:40 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:29:08 16/02/2023 09:31:05 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:29:08 16/02/2023 09:32:35 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:29:03 16/02/2023 09:29:09 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 16/02/2023 09:29:03 16/02/2023 09:29:15 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 16/02/2023 09:29:03 16/02/2023 09:29:39 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 16/02/2023 09:29:03 16/02/2023 09:30:31 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 16/02/2023 09:27:15 16/02/2023 09:27:32 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:27:15 16/02/2023 09:29:20 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:20:17 16/02/2023 09:20:23 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 16/02/2023 09:20:17 16/02/2023 09:20:29 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:20:17 16/02/2023 09:20:34 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 16/02/2023 09:20:17 16/02/2023 09:20:51 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:20:17 16/02/2023 09:27:20 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 16/02/2023 09:20:17 16/02/2023 09:27:26 44139966 44139966 1,0 1129 Elevator Failure Inspection drive unit stop button active
KRM_SERVER 16/02/2023 09:20:17 16/02/2023 09:29:55 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:20:17 16/02/2023 09:30:27 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:10:32 16/02/2023 09:10:40 44139966 44139966 1,0 1043 Elevator Failure Start permit fault
KRM_SERVER 16/02/2023 09:10:32 16/02/2023 09:10:46 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:10:32 16/02/2023 09:10:51 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:10:32 16/02/2023 09:10:58 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:10:32 16/02/2023 09:11:04 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:10:32 16/02/2023 09:11:10 44139966 44139966 1,0 1043 Elevator Failure Start permit fault
KRM_SERVER 16/02/2023 09:10:32 16/02/2023 09:11:16 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:10:32 16/02/2023 09:11:22 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:10:32 16/02/2023 09:11:51 44139966 44139966 1,0 1043 Elevator Failure Start permit fault
KRM_SERVER 16/02/2023 09:10:32 16/02/2023 09:11:57 44139966 44139966 1,0 1043 Elevator Failure Start permit fault
KRM_SERVER 16/02/2023 09:10:32 16/02/2023 09:20:40 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:10:32 16/02/2023 09:20:45 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:10:32 16/02/2023 09:21:02 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:10:32 16/02/2023 09:29:26 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:10:32 16/02/2023 09:29:33 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:10:32 16/02/2023 09:30:59 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:09:02 16/02/2023 09:12:02 44139966 44139966 1,0 1043 Elevator Failure Start permit fault
KRM_SERVER 16/02/2023 09:09:01 16/02/2023 09:32:41 44139966 44139966 1,0 1043 Elevator Failure Start permit fault
KRM_SERVER 16/02/2023 09:09:01 16/02/2023 09:32:47 44139966 44139966 1,0 1190 Elevator Failure Device picked input dropped while lift running
KRM_SERVER 16/02/2023 09:09:00 16/02/2023 09:32:54 44139966 44139966 1,0 1190 Elevator Failure Device picked input dropped while lift running
KRM_SERVER 16/02/2023 09:08:42 16/02/2023 09:08:52 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:08:42 16/02/2023 09:08:57 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:08:42 16/02/2023 09:09:03 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:08:42 16/02/2023 09:09:08 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:08:42 16/02/2023 09:09:31 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:08:42 16/02/2023 09:09:37 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:08:42 16/02/2023 09:32:59 44139966 44139966 1,0 1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
KRM_SERVER 16/02/2023 09:08:42 16/02/2023 09:33:05 44139966 44139966 1,0 1188 Elevator Failure Safety circuit: Buffers up input (H7)
KRM_SERVER 16/02/2023 09:03:51 16/02/2023 09:03:56 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:03:51 16/02/2023 09:04:02 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 09:03:51 16/02/2023 09:09:25 44139966 44139966 1,0 1039 Elevator Failure Door open monitoring functioned
KRM_SERVER 16/02/2023 06:26:57 16/02/2023 06:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/02/2023 20:08:49 15/02/2023 20:09:29 44139966 44139966 1,0 1702 Elevator Failure Start timeout
KRM_SERVER 15/02/2023 20:08:46 15/02/2023 20:09:06 44139966 44139966 1,0 1043 Elevator Failure Start permit fault
KRM_SERVER 15/02/2023 20:08:46 15/02/2023 20:09:12 44139966 44139966 1,0 1043 Elevator Failure Start permit fault
KRM_SERVER 15/02/2023 20:08:46 16/02/2023 09:09:14 44139966 44139966 1,0 1043 Elevator Failure Start permit fault
KRM_SERVER 15/02/2023 20:08:46 16/02/2023 09:09:20 44139966 44139966 1,0 1043 Elevator Failure Start permit fault
KRM_SERVER 15/02/2023 20:08:45 15/02/2023 20:08:55 44139966 44139966 1,0 1190 Elevator Failure Device picked input dropped while lift running
KRM_SERVER 15/02/2023 20:08:45 15/02/2023 20:09:01 44139966 44139966 1,0 1190 Elevator Failure Device picked input dropped while lift running
KRM_SERVER 15/02/2023 20:08:45 15/02/2023 20:09:17 44139966 44139966 1,0 1190 Elevator Failure Device picked input dropped while lift running
KRM_SERVER 15/02/2023 20:08:45 15/02/2023 20:09:23 44139966 44139966 1,0 1190 Elevator Failure Device picked input dropped while lift running
KRM_SERVER 15/02/2023 06:27:39 15/02/2023 06:27:39 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/02/2023 06:27:00 14/02/2023 06:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/02/2023 06:27:40 13/02/2023 06:27:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/02/2023 06:27:11 12/02/2023 06:27:12 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/02/2023 06:27:09 11/02/2023 06:27:09 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/02/2023 06:26:32 10/02/2023 06:26:32 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/02/2023 06:26:41 09/02/2023 06:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/02/2023 06:26:43 08/02/2023 06:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/02/2023 06:26:45 07/02/2023 06:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/02/2023 06:26:47 06/02/2023 06:26:47 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/02/2023 06:26:40 05/02/2023 06:26:40 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/02/2023 06:26:50 04/02/2023 06:26:50 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/02/2023 06:26:43 03/02/2023 06:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/02/2023 06:26:53 02/02/2023 06:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/02/2023 06:26:55 01/02/2023 06:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 31/01/2023 06:26:48 31/01/2023 06:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 30/01/2023 13:15:40 30/01/2023 13:15:45 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/01/2023 13:15:40 30/01/2023 13:16:03 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 30/01/2023 06:26:59 30/01/2023 06:26:59 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 29/01/2023 06:27:00 29/01/2023 06:27:00 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 28/01/2023 06:26:53 28/01/2023 06:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 27/01/2023 06:27:02 27/01/2023 06:27:02 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 26/01/2023 06:26:56 26/01/2023 06:26:56 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 25/01/2023 09:50:49 25/01/2023 09:50:49 44139966 44139966 1,0 102 Temporary Fault Test Alarm
KRM_SERVER 25/01/2023 06:27:06 25/01/2023 06:27:06 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 24/01/2023 06:27:07 24/01/2023 06:27:07 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 23/01/2023 06:27:10 23/01/2023 06:27:10 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 22/01/2023 06:27:12 22/01/2023 06:27:12 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 21/01/2023 06:27:13 21/01/2023 06:27:14 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 20/01/2023 06:27:15 20/01/2023 06:27:15 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 19/01/2023 06:26:43 19/01/2023 06:26:43 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 18/01/2023 06:26:44 18/01/2023 06:26:44 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 17/01/2023 06:26:37 17/01/2023 06:26:37 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 16/01/2023 06:26:48 16/01/2023 06:26:48 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 15/01/2023 06:26:41 15/01/2023 06:26:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 14/01/2023 06:26:41 18/01/2023 16:35:41 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 13/01/2023 06:26:52 13/01/2023 06:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 12/01/2023 06:26:45 12/01/2023 06:26:45 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 11/01/2023 16:20:18 11/01/2023 16:20:23 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/01/2023 16:20:18 11/01/2023 16:20:34 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/01/2023 09:16:49 11/01/2023 09:16:55 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/01/2023 09:16:49 11/01/2023 09:19:15 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 11/01/2023 06:26:55 11/01/2023 06:26:55 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 10/01/2023 06:26:57 10/01/2023 06:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 09/01/2023 06:26:58 09/01/2023 06:26:58 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 08/01/2023 06:27:00 08/01/2023 06:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 07/01/2023 06:26:53 07/01/2023 06:26:53 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 06/01/2023 13:02:51 06/01/2023 13:02:57 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/01/2023 13:02:51 06/01/2023 13:03:17 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/01/2023 10:37:38 06/01/2023 10:37:44 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/01/2023 10:37:38 06/01/2023 10:38:49 44139966 44139966 1,0 1607 Elevator Failure Reopen device active too long
KRM_SERVER 06/01/2023 06:27:03 06/01/2023 06:27:03 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 05/01/2023 06:27:04 05/01/2023 06:27:04 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 04/01/2023 06:26:57 04/01/2023 06:26:57 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 03/01/2023 06:27:08 03/01/2023 06:27:08 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 02/01/2023 06:27:01 02/01/2023 06:27:01 44139966 44139966 1,0 Réception Appel Cyclique
KRM_SERVER 01/01/2023 23:58:05 01/01/2023 23:58:10 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 01/01/2023 23:58:05 01/01/2023 23:58:16 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 01/01/2023 23:58:05 01/01/2023 23:58:22 44139966 44139966 1,0 1839 Elevator Failure KCEMSC missing from TTS-1
KRM_SERVER 01/01/2023 23:58:05 01/01/2023 23:58:27 44139966 44139966 1,0 1840 Elevator Failure KCEMSC missing from TTS-2
KRM_SERVER 01/01/2023 06:27:03 01/01/2023 06:27:03 44139966 44139966 1,0 Réception Appel Cyclique
<-- Retour resume 44139966