1033 |
Elevator Failure safety circuit: Buffers supervision. Up input failure
|
20 |
09/03/2026 08:31:56 |
|
1039 |
Elevator Failure Door open monitoring functioned
|
20 |
09/03/2026 08:35:56 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
16 |
09/03/2026 08:35:27 |
|
1099 |
Elevator Failure Main stop switch open |
6 |
09/03/2026 08:20:39 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
5 |
18/12/2025 11:40:56 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
5 |
18/12/2025 11:40:56 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
5 |
09/03/2026 08:20:40 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
5 |
07/03/2026 10:15:56 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
4 |
09/03/2026 08:28:59 |
|
1141 |
Elevator Failure Safety circuit: Inspection down limit
|
4 |
09/03/2026 08:20:37 |
|
1830 |
Elevator Failure LON communication error
|
2 |
06/02/2026 05:00:10 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
2 |
06/02/2026 05:00:27 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
2 |
06/02/2026 05:00:27 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
2 |
15/12/2025 10:45:18 |