Suivi Activite Telesurveillance 10503607


Infos Telalarme
N° Transmetteur 10503607
N° Equipement 10503607
Voie
N° de ligne telephonique 882390099693288
Equipements sur la meme ligne Telephonique 10503607,
Modele et profil TS KCE - DEFAULT KONE 4G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC 25/02/2014 10:32:29
Date dernier appel recu au CCC 09/03/2026 17:03:33
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 141
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
1032 Elevator Failure Safety circuit: swing door opened during drive 109 10/02/2026 17:23:19
SYSRCA Réception Appel Cyclique 94 09/03/2026 04:21:56
1011 Elevator Failure Car door contact opened during drive (C5) 34 04/03/2026 12:37:31
1004 Elevator Failure TTS serial communication broken. One channel 12 27/01/2026 21:19:19
1024 Elevator Failure Hoistway door bypass switch active 12 27/01/2026 21:29:45
1129 Elevator Failure Inspection drive unit stop button active 10 10/02/2026 17:25:17
1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range 8 27/01/2026 21:22:34
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 6 27/01/2026 21:36:06
1034 Elevator Failure safety circuit: Buffers supervision. Down input failure 6 27/01/2026 21:36:06
1054 Elevator Failure Safety circuit: ground fault 6 27/01/2026 21:36:06
1839 Elevator Failure KCEMSC missing from TTS-1 6 27/01/2026 21:19:09
1840 Elevator Failure KCEMSC missing from TTS-2 6 27/01/2026 21:19:09
1023 Elevator Failure Car door bypass switch active 4 27/01/2026 19:56:15
1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2) 4 27/01/2026 21:22:34
1181 Elevator Failure Door bypass switch misuse 4 27/01/2026 19:56:16
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 4 10/02/2026 19:19:21
1031 Elevator Failure Safety circuit: Landing door opened during drive 3 10/02/2026 17:23:19
100 Temporary Fault Unclassified Alarm 1 20/02/2026 15:46:49