| SYSRCA |
|
Réception Appel Cyclique |
92 |
09/03/2026 08:55:58 |
|
4017 |
Elevator Failure KCEAPM 12V power failed (battery failure)
|
64 |
02/02/2026 13:53:10 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
12 |
05/03/2026 13:54:40 |
|
1099 |
Elevator Failure Main stop switch open |
7 |
02/02/2026 13:02:43 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
4 |
02/02/2026 12:40:05 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
4 |
02/02/2026 13:02:30 |
|
200 |
System failure: KCE System failure: KCE |
4 |
02/02/2026 12:36:05 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
3 |
01/02/2026 10:44:25 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
2 |
02/02/2026 11:57:03 |
|
1044 |
Elevator Failure Drive not OK
|
2 |
02/02/2026 12:40:22 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
2 |
02/02/2026 12:02:06 |
|
1820 |
Elevator Failure Drive communication broken
|
2 |
02/02/2026 12:40:06 |
|
1830 |
Elevator Failure LON communication error
|
2 |
16/12/2025 02:38:16 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
2 |
16/12/2025 02:38:33 |
|
2000 |
Elevator Failure Missing COP
|
2 |
05/03/2026 14:04:47 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
2 |
06/01/2026 16:14:17 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
2 |
16/01/2026 08:02:47 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
02/02/2026 13:15:36 |
|
1113 |
Elevator Failure TTS communication stuck
|
1 |
02/02/2026 12:40:26 |