Suivi Activite Telesurveillance 10552933


Infos Telalarme
N° Transmetteur 10552933
N° Equipement 10552933
Voie
N° de ligne telephonique 882397129819668
Equipements sur la meme ligne Telephonique 10552933,
Modele et profil TS KCE - DEFAULT KONE 3G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 11:07:58
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 172
Option contrat "Lien vocal" KONEXION DIRECT MISE A DISPO.
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSRCA Réception Appel Cyclique 92 09/03/2026 12:07:53
1115 Elevator Failure KCEMSC board failure - Safety input power supply 40 19/02/2026 10:54:25
1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range 31 19/02/2026 10:54:19
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 30 19/02/2026 11:31:43
1117 Elevator Failure KMI stop switch active 28 19/02/2026 11:32:52
1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2) 26 19/02/2026 11:31:41
1839 Elevator Failure KCEMSC missing from TTS-1 22 20/02/2026 06:21:18
1840 Elevator Failure KCEMSC missing from TTS-2 19 20/02/2026 06:21:18
1004 Elevator Failure TTS serial communication broken. One channel 17 19/02/2026 11:01:14
1000 Elevator Failure Serial communication broken on board (both TTS channels) 15 19/02/2026 10:31:58
1031 Elevator Failure Safety circuit: Landing door opened during drive 15 19/02/2026 11:47:08
1024 Elevator Failure Hoistway door bypass switch active 10 19/02/2026 11:12:30
1002 Elevator Failure Serial communication broken on board (TTS-1) 9 19/02/2026 10:31:58
1607 Elevator Failure Reopen device active too long 8 16/02/2026 12:35:30
1068 Elevator Failure 24V power supply voltage out of +- 20 % range 7 19/02/2026 09:57:58
1099 Elevator Failure Main stop switch open 7 19/02/2026 09:57:58
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 7 19/02/2026 10:46:03
1011 Elevator Failure Car door contact opened during drive (C5) 6 22/01/2026 12:45:13
1072 Elevator Failure Energy saving failure 6 19/02/2026 10:54:19
2000 Elevator Failure Missing COP 5 19/02/2026 10:30:11
1003 Elevator Failure Serial communication broken on board (TTS-2) 3 19/02/2026 10:30:08
4017 Elevator Failure KCEAPM 12V power failed (battery failure) 2 19/02/2026 11:36:13
103 False Alarm False Alarm 1 07/01/2026 19:56:13
<-- Retour KOF