| SYSRCA |
|
Réception Appel Cyclique |
30 |
10/03/2026 02:58:36 |
| SYSEVE |
162003 |
System Failure OK: low: Analyzer ENGINEER ONSITE BY MACHINEROOM |
22 |
23/02/2026 11:15:41 |
| SYSEVE |
162003 |
System Failure: low: Analyzer ENGINEER ONSITE BY MACHINEROOM |
22 |
23/02/2026 10:40:36 |
| SYSEVE |
153000 |
System Failure OK: low: Rif ENGINEER ON SITE |
13 |
23/02/2026 11:15:52 |
| SYSEVE |
153000 |
System Failure: low: Rif ENGINEER ON SITE |
13 |
23/02/2026 10:40:51 |
| SYSEVE |
162001 |
System Failure: low: Analyzer MONITORING ON |
10 |
26/01/2026 12:36:49 |
| SYSEVE |
162006 |
System Failure: low: Analyzer DATA_LINK |
10 |
26/01/2026 12:36:49 |
| SYSEVE |
152004 |
System Failure: low: Rif TEST ALARM FROM CAR (TAT) |
3 |
04/03/2026 11:34:50 |
| EQUFAI |
10001 |
Elevator OK DRIVE_TIME_SUPERVISION_ELAPSED |
2 |
26/01/2026 11:13:04 |
| EQUFAI |
2001 |
Elevator Failure SHAFT_DOOR_CONTACT_OPENED_DURING_DRIVE |
2 |
28/01/2026 17:00:00 |
| EQUFAI |
2001 |
Elevator OK SHAFT_DOOR_CONTACT_OPENED_DURING_DRIVE |
2 |
02/02/2026 10:37:01 |
| EQUFAI |
25001 |
Elevator Failure CAR_DOOR_CONTACT_OPENED_DURING_DRIVE |
2 |
16/02/2026 14:56:52 |
| EQUFAI |
25001 |
Elevator OK CAR_DOOR_CONTACT_OPENED_DURING_DRIVE |
2 |
16/02/2026 15:58:28 |
| EQUFAI |
1002 |
Elevator OK SAFETY_CIRCUIT_BROKEN |
1 |
26/01/2026 11:32:31 |
| EQUFAI |
11004 |
Elevator OK POSITION_LOST_1 |
1 |
26/01/2026 11:13:02 |
| EQUFAI |
38009 |
Elevator OK DRIVE_STOP |
1 |
26/01/2026 10:56:22 |
| SYSFAI |
151009 |
System Failure OK: low: Rif MAIN POWER FAIL |
1 |
01/02/2026 22:27:34 |
| SYSFAI |
151009 |
System Failure: low: Rif MAIN POWER FAIL |
1 |
01/02/2026 22:27:34 |
| SYSFAI |
151009 |
System Failure: Rif MAIN POWER FAIL |
1 |
26/01/2026 13:17:45 |