| SYSRCA |
|
Réception Appel Cyclique |
91 |
09/03/2026 06:33:40 |
| SYSEVE |
162003 |
System Failure OK: low: Analyzer ENGINEER ONSITE BY MACHINEROOM |
21 |
13/01/2026 15:03:34 |
| SYSEVE |
162003 |
System Failure: low: Analyzer ENGINEER ONSITE BY MACHINEROOM |
20 |
13/01/2026 15:03:20 |
| SYSEVE |
153000 |
System Failure OK: low: Rif ENGINEER ON SITE |
15 |
13/01/2026 15:03:38 |
| SYSEVE |
153000 |
System Failure: low: Rif ENGINEER ON SITE |
15 |
13/01/2026 15:03:23 |
| EQUFAI |
2001 |
Elevator Failure SHAFT_DOOR_CONTACT_OPENED_DURING_DRIVE |
3 |
24/02/2026 09:24:44 |
| EQUFAI |
2001 |
Elevator OK SHAFT_DOOR_CONTACT_OPENED_DURING_DRIVE |
3 |
24/02/2026 10:53:16 |
| SYSFAI |
151009 |
System Failure OK: low: Rif MAIN POWER FAIL |
3 |
05/01/2026 11:50:16 |
| SYSFAI |
151009 |
System Failure: low: Rif MAIN POWER FAIL |
3 |
05/01/2026 11:49:39 |
| SYSEVE |
162001 |
System Failure: low: Analyzer MONITORING ON |
2 |
05/01/2026 11:48:49 |
| SYSEVE |
162004 |
System Failure OK: low: Analyzer ENGINEER ONSITE BY 261-SWITCH |
2 |
05/01/2026 12:05:00 |
| SYSEVE |
162004 |
System Failure: low: Analyzer ENGINEER ONSITE BY 261-SWITCH |
2 |
05/01/2026 11:46:17 |
| SYSEVE |
162005 |
System Failure OK: low: Analyzer ENGINEER ONSITE BY 263-SWITCH |
2 |
05/01/2026 12:05:00 |
| SYSEVE |
162005 |
System Failure: low: Analyzer ENGINEER ONSITE BY 263-SWITCH |
2 |
05/01/2026 11:46:18 |
| SYSEVE |
162006 |
System Failure: low: Analyzer DATA_LINK |
2 |
05/01/2026 11:48:49 |
| SYSFAI |
151014 |
System Failure OK: low: Rif ANALYZER POWER FAIL |
2 |
05/01/2026 11:50:25 |
| EQUFAI |
3002 |
Elevator Failure REOPEN_DEVICE_ACTIVE_LONGER_1_MINUTE |
1 |
05/01/2026 07:30:05 |
| EQUFAI |
3002 |
Elevator OK REOPEN_DEVICE_ACTIVE_LONGER_1_MINUTE |
1 |
05/01/2026 11:46:40 |
| SYSFAI |
151013 |
System Failure OK: low: Rif NO CONNECTION TO ANALYZER |
1 |
05/01/2026 11:50:55 |
| SYSFAI |
151015 |
System Failure: low: Rif ON SITE NETWORK CONFIGURATION ERROR |
1 |
05/01/2026 11:50:40 |