| SYSRCA |
|
Réception Appel Cyclique |
96 |
10/03/2026 00:43:50 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
8 |
03/03/2026 17:53:57 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
8 |
12/02/2026 13:47:23 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
5 |
24/12/2025 18:58:06 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
4 |
08/01/2026 13:16:56 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
4 |
03/03/2026 17:53:48 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
4 |
03/03/2026 17:53:48 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
3 |
24/12/2025 17:40:44 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
3 |
24/12/2025 18:14:51 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
30/01/2026 09:59:58 |
|
1140 |
Elevator Failure Safety circuit: Inspection up limit
|
1 |
24/12/2025 18:21:22 |