| SYSRCA |
|
Réception Appel Cyclique |
96 |
10/03/2026 03:59:01 |
|
1117 |
Elevator Failure KMI stop switch active
|
32 |
05/03/2026 11:11:44 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
24 |
02/02/2026 12:20:46 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
20 |
02/02/2026 12:34:10 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
13 |
05/03/2026 11:11:39 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
12 |
05/03/2026 11:11:39 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
8 |
05/03/2026 11:11:48 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
4 |
02/02/2026 10:14:04 |
|
1830 |
Elevator Failure LON communication error
|
2 |
02/01/2026 06:32:22 |