| SYSRCA |
|
Réception Appel Cyclique |
95 |
10/03/2026 03:21:48 |
|
1037 |
Elevator Failure Car door: stuck contact
|
20 |
21/02/2026 17:33:03 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
15 |
17/02/2026 11:02:42 |
|
1023 |
Elevator Failure Car door bypass switch active
|
8 |
21/02/2026 18:23:32 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
6 |
23/01/2026 23:01:46 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
4 |
21/02/2026 18:44:24 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
4 |
27/02/2026 08:16:28 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
4 |
26/01/2026 09:57:52 |
|
1066 |
Elevator Failure TTS2 communication fault |
4 |
23/01/2026 21:01:31 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
4 |
21/02/2026 18:44:59 |
|
1099 |
Elevator Failure Main stop switch open |
4 |
21/02/2026 18:44:59 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
4 |
24/01/2026 00:07:19 |
|
1140 |
Elevator Failure Safety circuit: Inspection up limit
|
3 |
17/02/2026 10:37:01 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
3 |
14/02/2026 20:29:00 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
3 |
14/02/2026 20:29:00 |
|
1607 |
Elevator Failure Reopen device active too long
|
2 |
03/02/2026 15:07:38 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
21/02/2026 17:28:28 |
|
101 |
Real Alarm Real Alarm |
1 |
21/02/2026 17:29:24 |