1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
187 |
09/03/2026 08:33:20 |
| SYSRCA |
|
Réception Appel Cyclique |
93 |
10/03/2026 04:02:02 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
38 |
20/12/2025 07:59:30 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
32 |
07/03/2026 06:03:53 |
|
1702 |
Elevator Failure Start timeout
|
27 |
08/02/2026 19:48:34 |
|
1703 |
Elevator Failure Start failed
|
23 |
05/03/2026 06:00:32 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
3 |
13/02/2026 07:16:13 |
|
102 |
Temporary Fault Test Alarm |
2 |
21/02/2026 09:49:50 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
2 |
23/12/2025 09:46:53 |
|
103 |
False Alarm False Alarm |
2 |
26/02/2026 17:58:19 |
|
1830 |
Elevator Failure LON communication error
|
2 |
13/02/2026 07:15:59 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
2 |
13/02/2026 07:16:13 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
05/01/2026 15:50:05 |