| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 15:24:04 |
|
2000 |
Elevator Failure Missing COP
|
10 |
06/03/2026 21:14:33 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
6 |
04/03/2026 22:38:47 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
4 |
04/03/2026 22:38:47 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
4 |
04/03/2026 22:36:13 |
|
1830 |
Elevator Failure LON communication error
|
4 |
27/02/2026 07:18:58 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
4 |
27/02/2026 07:19:08 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
4 |
27/02/2026 07:19:08 |
|
1603 |
Elevator Failure Car door contact does not open
|
2 |
12/12/2025 16:49:14 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
2 |
09/03/2026 19:08:52 |
|
101 |
Real Alarm Real Alarm |
1 |
02/01/2026 11:54:08 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
1 |
02/03/2026 00:25:15 |