| SYSRCA |
|
Réception Appel Cyclique |
90 |
09/03/2026 06:09:37 |
| SYSFAI |
151007 |
System Failure: Rif BATTERY FAIL |
6 |
03/02/2026 00:19:29 |
| SYSEVE |
152004 |
System Failure: low: Rif TEST ALARM FROM CAR (TAT) |
2 |
04/03/2026 16:00:05 |
| SYSFAI |
151013 |
System Failure OK: low: Rif NO CONNECTION TO ANALYZER |
2 |
03/02/2026 03:47:33 |
| SYSFAI |
151015 |
System Failure: low: Rif ON SITE NETWORK CONFIGURATION ERROR |
2 |
03/02/2026 03:47:18 |
| DEBEVE |
153104 |
System Failure: low: Rif RIF RESET: RESET BY USER |
1 |
30/01/2026 06:09:44 |
| EQUFAI |
1002 |
Elevator Failure SAFETY_CIRCUIT_BROKEN |
1 |
04/03/2026 15:24:22 |
| EQUFAI |
1002 |
Elevator OK SAFETY_CIRCUIT_BROKEN |
1 |
04/03/2026 15:58:52 |
| EQUFAI |
19090 |
Elevator OK DRIVE FEEDBACK ERROR |
1 |
03/02/2026 08:56:49 |
| EQUFAI |
9001 |
Elevator Failure ELEVATOR_NOT_MOVING_BY_V1_ANALYZER |
1 |
11/01/2026 09:02:22 |
| EQUFAI |
9001 |
Elevator OK ELEVATOR_NOT_MOVING_BY_V1_ANALYZER |
1 |
12/01/2026 08:56:32 |
| SYSFAI |
151009 |
System Failure OK: low: Rif MAIN POWER FAIL |
1 |
04/02/2026 07:48:39 |
| SYSFAI |
151009 |
System Failure: low: Rif MAIN POWER FAIL |
1 |
04/02/2026 07:39:52 |
| SYSFAI |
151014 |
System Failure OK: low: Rif ANALYZER POWER FAIL |
1 |
04/02/2026 07:48:45 |
| SYSFAI |
151014 |
System Failure: low: Rif ANALYZER POWER FAIL |
1 |
04/02/2026 07:42:45 |