| SYSRCA |
|
Réception Appel Cyclique |
78 |
09/03/2026 14:43:43 |
| EQUFAI |
9001 |
Elevator Failure ELEVATOR_NOT_MOVING_BY_V1_ANALYZER |
35 |
08/03/2026 17:20:04 |
| EQUFAI |
9001 |
Elevator OK ELEVATOR_NOT_MOVING_BY_V1_ANALYZER |
29 |
09/03/2026 06:36:38 |
| SYSEVE |
162003 |
System Failure: low: Analyzer ENGINEER ONSITE BY MACHINEROOM |
13 |
20/02/2026 13:40:54 |
| SYSEVE |
162003 |
System Failure OK: low: Analyzer ENGINEER ONSITE BY MACHINEROOM |
11 |
20/02/2026 13:45:12 |
| SYSFAI |
151009 |
System Failure OK: low: Rif MAIN POWER FAIL |
9 |
20/02/2026 13:42:11 |
| SYSFAI |
151009 |
System Failure: low: Rif MAIN POWER FAIL |
9 |
20/02/2026 13:42:05 |
| SYSEVE |
153000 |
System Failure OK: low: Rif ENGINEER ON SITE |
8 |
20/02/2026 13:45:11 |
| SYSEVE |
153000 |
System Failure: low: Rif ENGINEER ON SITE |
8 |
20/02/2026 13:40:56 |
| SYSEVE |
162001 |
System Failure: low: Analyzer MONITORING ON |
8 |
10/02/2026 14:18:17 |
| SYSEVE |
162006 |
System Failure: low: Analyzer DATA_LINK |
8 |
10/02/2026 14:18:17 |
| SYSFAI |
151014 |
System Failure OK: low: Rif ANALYZER POWER FAIL |
6 |
03/01/2026 11:03:28 |
| SYSEVE |
162013 |
System Failure: low: Analyzer FALSE ALARM |
4 |
10/02/2026 14:19:55 |
| EQUFAI |
3002 |
Elevator Failure REOPEN_DEVICE_ACTIVE_LONGER_1_MINUTE |
3 |
03/01/2026 14:17:43 |
| EQUFAI |
3002 |
Elevator OK REOPEN_DEVICE_ACTIVE_LONGER_1_MINUTE |
3 |
04/01/2026 08:56:51 |
| EQUFAI |
2001 |
Elevator Failure SHAFT_DOOR_CONTACT_OPENED_DURING_DRIVE |
2 |
02/01/2026 08:15:24 |
| EQUFAI |
2001 |
Elevator OK SHAFT_DOOR_CONTACT_OPENED_DURING_DRIVE |
2 |
03/01/2026 08:17:34 |
| SYSEVE |
152000 |
System Failure: low: Rif ALARM FROM CAR |
2 |
09/01/2026 13:48:07 |
|
255559 |
Test Alarm (Direct Call) Test Alarm (Direct Call) |
1 |
09/01/2026 13:53:36 |
| EQUFAI |
1002 |
Test Alarm (Direct Call) SAFETY_CIRCUIT_BROKEN |
1 |
10/02/2026 14:22:17 |
| EQUFAI |
38009 |
Elevator OK DRIVE_STOP |
1 |
03/01/2026 11:10:46 |
| EQUFAI |
4001 |
Elevator Failure RELEVELING_FAILED |
1 |
03/01/2026 08:46:40 |
| EQUFAI |
4001 |
Elevator OK RELEVELING_FAILED |
1 |
03/01/2026 10:17:45 |
| SYSEVE |
152003 |
System Failure: low: Rif ALARM FROM CAR UNCONDITIONAL |
1 |
09/01/2026 13:48:55 |
| SYSFAI |
151014 |
System Failure: low: Rif ANALYZER POWER FAIL |
1 |
03/01/2026 10:54:13 |