Suivi Activite Telesurveillance 10996276


Infos Telalarme
N° Transmetteur 10996276
N° Equipement 10996276
Voie
N° de ligne telephonique 882397106459352
Equipements sur la meme ligne Telephonique 10996276,
Modele et profil TS KCE - DEFAULT KONE 3G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 10/03/2026 02:50:54
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 148
Option contrat "Lien vocal" Inclus
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSRCA Réception Appel Cyclique 102 09/03/2026 10:16:24
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 38 09/03/2026 16:24:15
1044 Elevator Failure Drive not OK 13 23/12/2025 10:43:07
1032 Elevator Failure Safety circuit: swing door opened during drive 10 30/12/2025 13:50:46
1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8) 8 30/12/2025 13:56:21
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 8 09/03/2026 17:20:20
1117 Elevator Failure KMI stop switch active 6 09/03/2026 16:18:33
1091 Elevator Failure Lift on final limit magnet 5 23/12/2025 14:33:16
1814 Elevator Failure Drive unit fault 5 23/12/2025 10:43:06
1129 Elevator Failure Inspection drive unit stop button active 4 30/12/2025 13:56:17
1008 Elevator Failure Safety circuit: Safety gear (C2) 3 23/12/2025 14:40:33
1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2) 3 23/12/2025 14:41:00
1109 Elevator Failure Landing door not opened after top of car inspection 2 30/12/2025 13:56:48
1702 Elevator Failure Start timeout 2 30/12/2025 13:53:52
1839 Elevator Failure KCEMSC missing from TTS-1 2 25/02/2026 05:21:05
1830 Elevator Failure LON communication error 1 25/02/2026 05:20:49
1840 Elevator Failure KCEMSC missing from TTS-2 1 25/02/2026 05:21:05
<-- Retour KOF