| SYSRCA |
|
Réception Appel Cyclique |
90 |
09/03/2026 13:44:43 |
| SYSEVE |
162001 |
System Failure: low: Analyzer MONITORING ON |
8 |
02/03/2026 09:44:44 |
| SYSEVE |
162006 |
System Failure: low: Analyzer DATA_LINK |
8 |
02/03/2026 09:44:44 |
| SYSFAI |
151009 |
System Failure OK: low: Rif MAIN POWER FAIL |
7 |
12/02/2026 14:39:15 |
| SYSFAI |
151009 |
System Failure: low: Rif MAIN POWER FAIL |
7 |
12/02/2026 14:39:12 |
| SYSFAI |
151014 |
System Failure OK: low: Rif ANALYZER POWER FAIL |
6 |
02/03/2026 09:45:09 |
| SYSEVE |
153000 |
System Failure OK: low: Rif ENGINEER ON SITE |
4 |
02/03/2026 09:45:10 |
| SYSEVE |
153000 |
System Failure: low: Rif ENGINEER ON SITE |
4 |
02/03/2026 09:44:39 |
| SYSEVE |
162003 |
System Failure OK: low: Analyzer ENGINEER ONSITE BY MACHINEROOM |
4 |
02/03/2026 09:44:43 |
| SYSEVE |
162003 |
System Failure: low: Analyzer ENGINEER ONSITE BY MACHINEROOM |
4 |
02/03/2026 09:44:32 |
| DEBEVE |
153104 |
System Failure: low: Rif RIF RESET: RESET BY USER |
1 |
06/02/2026 13:45:52 |
| EQUFAI |
2001 |
Elevator OK SHAFT_DOOR_CONTACT_OPENED_DURING_DRIVE |
1 |
02/03/2026 09:45:39 |