Suivi Activite Telesurveillance 11023967


Infos Telalarme
N° Transmetteur 11023967
N° Equipement 11023967
Voie
N° de ligne telephonique 882397143422174
Equipements sur la meme ligne Telephonique 11023967,
Modele et profil TS KCE - DEFAULT KONE 3G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC 31/05/2013 08:53:59
Date dernier appel recu au CCC 09/03/2026 15:40:16
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 208
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSRCA Réception Appel Cyclique 99 09/03/2026 16:40:10
1607 Elevator Failure Reopen device active too long 81 08/03/2026 19:50:31
1031 Elevator Failure Safety circuit: Landing door opened during drive 32 26/02/2026 12:36:10
1702 Elevator Failure Start timeout 12 26/02/2026 12:50:38
1040 Elevator Failure Drive time supervision 10 29/01/2026 13:50:11
1011 Elevator Failure Car door contact opened during drive (C5) 8 17/02/2026 21:47:43
1129 Elevator Failure Inspection drive unit stop button active 8 04/02/2026 16:46:19
1117 Elevator Failure KMI stop switch active 7 29/01/2026 13:51:04
1035 Elevator Failure Unintended movement 6 29/01/2026 13:50:11
1004 Elevator Failure TTS serial communication broken. One channel 4 29/01/2026 13:51:08
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 4 31/12/2025 11:31:59
1703 Elevator Failure Start failed 4 04/02/2026 16:44:42
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 4 29/01/2026 14:51:44
4018 Elevator Failure KCEAPM has no connection to KCECPU 4 20/02/2026 11:34:42
100 Temporary Fault Unclassified Alarm 3 07/03/2026 13:54:13
103 False Alarm False Alarm 2 15/02/2026 09:43:44
1839 Elevator Failure KCEMSC missing from TTS-1 2 29/01/2026 13:51:00
1840 Elevator Failure KCEMSC missing from TTS-2 2 29/01/2026 13:51:00