| SYSRCA |
|
Réception Appel Cyclique |
92 |
10/03/2026 01:01:54 |
| SYSEVE |
162003 |
System Failure OK: low: Analyzer ENGINEER ONSITE BY MACHINEROOM |
14 |
04/03/2026 16:13:27 |
| SYSEVE |
162003 |
System Failure: low: Analyzer ENGINEER ONSITE BY MACHINEROOM |
14 |
04/03/2026 16:03:05 |
| SYSEVE |
152000 |
System Failure: low: Rif ALARM FROM CAR |
12 |
04/03/2026 15:41:08 |
| SYSEVE |
153000 |
System Failure OK: low: Rif ENGINEER ON SITE |
12 |
04/03/2026 16:13:30 |
| SYSEVE |
153000 |
System Failure: low: Rif ENGINEER ON SITE |
12 |
04/03/2026 16:03:15 |
| SYSEVE |
162001 |
System Failure: low: Analyzer MONITORING ON |
5 |
04/03/2026 16:09:51 |
| SYSEVE |
162006 |
System Failure: low: Analyzer DATA_LINK |
5 |
04/03/2026 16:09:51 |
| SYSFAI |
151009 |
System Failure OK: low: Rif MAIN POWER FAIL |
5 |
26/02/2026 12:32:18 |
| SYSFAI |
151009 |
System Failure: low: Rif MAIN POWER FAIL |
5 |
26/02/2026 12:32:16 |
| SYSFAI |
151014 |
System Failure OK: low: Rif ANALYZER POWER FAIL |
5 |
04/03/2026 16:12:15 |
|
255255 |
Emergency Alarm (Direct Call) Emergency Alarm (Direct Call) |
4 |
26/02/2026 10:47:50 |
|
255255 |
False Alarm (Direct Call) False Alarm (Direct Call) |
3 |
04/03/2026 15:32:28 |
|
255255 |
Test Alarm (Direct Call) Test Alarm (Direct Call) |
3 |
04/03/2026 15:42:25 |
| SYSEVE |
152004 |
System Failure: low: Rif TEST ALARM FROM CAR (TAT) |
3 |
25/02/2026 09:32:37 |
|
255255 |
Unclassified Alarm (Direct Call) Unclassified Alarm (Direct Call) |
2 |
26/02/2026 12:07:50 |
| SYSEVE |
162005 |
System Failure: low: Analyzer ENGINEER ONSITE BY 263-SWITCH |
2 |
26/02/2026 12:28:22 |
| SYSEVE |
162013 |
System Failure: low: Analyzer FALSE ALARM |
2 |
26/02/2026 11:43:09 |
| EQUFAI |
2001 |
Elevator OK SHAFT_DOOR_CONTACT_OPENED_DURING_DRIVE |
1 |
04/03/2026 16:14:12 |
| EQUFAI |
3002 |
Elevator OK REOPEN_DEVICE_ACTIVE_LONGER_1_MINUTE |
1 |
26/02/2026 11:57:02 |
| EQUFAI |
3002 |
False Alarm (Direct Call) REOPEN_DEVICE_ACTIVE_LONGER_1_MINUTE |
1 |
26/02/2026 11:44:54 |
| SYSEVE |
152003 |
System Failure: low: Rif ALARM FROM CAR UNCONDITIONAL |
1 |
26/02/2026 11:43:42 |
| SYSEVE |
162004 |
System Failure OK: low: Analyzer ENGINEER ONSITE BY 261-SWITCH |
1 |
04/03/2026 15:36:09 |
| SYSEVE |
162004 |
System Failure: low: Analyzer ENGINEER ONSITE BY 261-SWITCH |
1 |
26/02/2026 12:28:22 |
| SYSEVE |
162005 |
System Failure OK: low: Analyzer ENGINEER ONSITE BY 263-SWITCH |
1 |
04/03/2026 15:36:10 |