| SYSRCA |
|
Réception Appel Cyclique |
47 |
10/03/2026 02:16:12 |
| SYSEVE |
162001 |
System Failure: low: Analyzer MONITORING ON |
11 |
14/02/2026 15:12:48 |
| SYSEVE |
162003 |
System Failure OK: low: Analyzer ENGINEER ONSITE BY MACHINEROOM |
11 |
27/02/2026 14:23:43 |
| SYSEVE |
162003 |
System Failure: low: Analyzer ENGINEER ONSITE BY MACHINEROOM |
11 |
27/02/2026 14:14:05 |
| SYSEVE |
162006 |
System Failure: low: Analyzer DATA_LINK |
11 |
14/02/2026 15:12:48 |
| SYSEVE |
153000 |
System Failure OK: low: Rif ENGINEER ON SITE |
10 |
27/02/2026 14:23:55 |
| SYSEVE |
153000 |
System Failure: low: Rif ENGINEER ON SITE |
10 |
27/02/2026 14:14:10 |
| SYSFAI |
151014 |
System Failure OK: low: Rif ANALYZER POWER FAIL |
10 |
14/02/2026 15:17:20 |
| SYSFAI |
151009 |
System Failure OK: low: Rif MAIN POWER FAIL |
7 |
14/02/2026 15:17:20 |
| SYSFAI |
151009 |
System Failure: low: Rif MAIN POWER FAIL |
7 |
14/02/2026 15:17:20 |
| SYSFAI |
151014 |
System Failure: low: Rif ANALYZER POWER FAIL |
7 |
14/02/2026 15:15:50 |
| SYSEVE |
162005 |
System Failure OK: low: Analyzer ENGINEER ONSITE BY 263-SWITCH |
4 |
31/12/2025 10:14:41 |
| SYSEVE |
162005 |
System Failure: low: Analyzer ENGINEER ONSITE BY 263-SWITCH |
4 |
31/12/2025 10:03:55 |
| SYSEVE |
162004 |
System Failure OK: low: Analyzer ENGINEER ONSITE BY 261-SWITCH |
3 |
31/12/2025 10:14:41 |
| SYSEVE |
162004 |
System Failure: low: Analyzer ENGINEER ONSITE BY 261-SWITCH |
3 |
31/12/2025 10:03:55 |
| EQUFAI |
1002 |
Test Alarm (Direct Call) SAFETY_CIRCUIT_BROKEN |
2 |
12/02/2026 09:37:14 |
| SYSEVE |
152000 |
System Failure: low: Rif ALARM FROM CAR |
2 |
12/02/2026 09:36:03 |
| EQUFAI |
25001 |
Elevator OK CAR_DOOR_CONTACT_OPENED_DURING_DRIVE |
1 |
22/12/2025 15:17:04 |
| SYSFAI |
151013 |
System Failure OK: low: Rif NO CONNECTION TO ANALYZER |
1 |
17/12/2025 14:54:47 |
| SYSFAI |
151015 |
System Failure: low: Rif ON SITE NETWORK CONFIGURATION ERROR |
1 |
17/12/2025 14:54:32 |