| SYSRCA |
|
Réception Appel Cyclique |
92 |
09/03/2026 17:50:41 |
| SYSEVE |
162001 |
System Failure: low: Analyzer MONITORING ON |
58 |
15/02/2026 14:09:34 |
| SYSEVE |
162006 |
System Failure: low: Analyzer DATA_LINK |
58 |
15/02/2026 14:09:34 |
| SYSFAI |
151014 |
System Failure OK: low: Rif ANALYZER POWER FAIL |
36 |
16/02/2026 16:01:05 |
| SYSFAI |
151009 |
System Failure OK: low: Rif MAIN POWER FAIL |
26 |
16/02/2026 11:29:50 |
| SYSFAI |
151009 |
System Failure: low: Rif MAIN POWER FAIL |
26 |
16/02/2026 11:29:44 |
| SYSEVE |
153000 |
System Failure OK: low: Rif ENGINEER ON SITE |
23 |
16/02/2026 16:01:50 |
| SYSEVE |
153000 |
System Failure: low: Rif ENGINEER ON SITE |
23 |
16/02/2026 16:01:35 |
| SYSEVE |
162003 |
System Failure OK: low: Analyzer ENGINEER ONSITE BY MACHINEROOM |
16 |
13/02/2026 14:01:09 |
| SYSEVE |
162003 |
System Failure: low: Analyzer ENGINEER ONSITE BY MACHINEROOM |
16 |
13/02/2026 13:55:03 |
| EQUFAI |
6010 |
Elevator OK DOOR_ZONE_SWITCH_30_OR_B30_STUCK |
12 |
13/02/2026 14:01:52 |
| EQUFAI |
6010 |
Elevator Failure DOOR_ZONE_SWITCH_30_OR_B30_STUCK |
11 |
13/02/2026 08:12:28 |
| EQUFAI |
6005 |
Elevator OK FAULT_FROM_DRIVE_SYSTEM |
6 |
16/02/2026 15:03:37 |
| EQUFAI |
6005 |
Elevator Failure FAULT_FROM_DRIVE_SYSTEM |
4 |
13/02/2026 15:18:16 |
| SYSEVE |
152000 |
System Failure: low: Rif ALARM FROM CAR |
3 |
03/03/2026 16:06:21 |
| EQUFAI |
10001 |
Elevator OK DRIVE_TIME_SUPERVISION_ELAPSED |
2 |
13/02/2026 14:01:45 |
| EQUFAI |
1002 |
Elevator Failure SAFETY_CIRCUIT_BROKEN |
2 |
13/02/2026 14:03:58 |
| SYSEVE |
152003 |
System Failure: low: Rif ALARM FROM CAR UNCONDITIONAL |
2 |
16/02/2026 16:06:39 |
| SYSEVE |
162013 |
System Failure: low: Analyzer FALSE ALARM |
2 |
03/03/2026 16:07:27 |
|
255255 |
Test Alarm (Direct Call) Test Alarm (Direct Call) |
1 |
16/02/2026 16:07:49 |
| EQUFAI |
10001 |
Elevator Failure DRIVE_TIME_SUPERVISION_ELAPSED |
1 |
05/02/2026 11:25:47 |
| EQUFAI |
1002 |
Elevator OK SAFETY_CIRCUIT_BROKEN |
1 |
10/02/2026 17:25:32 |
| EQUFAI |
11004 |
Elevator OK POSITION_LOST_1 |
1 |
16/02/2026 16:02:34 |
| EQUFAI |
38008 |
Elevator OK POSITION_LOST_2 |
1 |
16/02/2026 15:36:01 |
| EQUFAI |
6010 |
Emergency Alarm (Direct Call) DOOR_ZONE_SWITCH_30_OR_B30_STUCK |
1 |
04/02/2026 11:47:25 |
| EQUFAI |
6010 |
Unclassified Alarm (Direct Call) DOOR_ZONE_SWITCH_30_OR_B30_STUCK |
1 |
04/02/2026 11:50:21 |
| SYSFAI |
151014 |
System Failure: low: Rif ANALYZER POWER FAIL |
1 |
11/02/2026 10:56:31 |