| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 08:19:02 |
|
1607 |
Elevator Failure Reopen device active too long
|
38 |
03/03/2026 21:40:37 |
|
1702 |
Elevator Failure Start timeout
|
31 |
26/02/2026 17:23:52 |
|
1013 |
Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
|
20 |
28/01/2026 12:36:30 |
|
1015 |
Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
|
20 |
28/01/2026 12:37:15 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
16 |
28/01/2026 12:29:25 |
|
1117 |
Elevator Failure KMI stop switch active
|
8 |
08/01/2026 14:12:46 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
4 |
08/01/2026 14:12:50 |
|
1044 |
Elevator Failure Drive not OK
|
4 |
29/01/2026 10:35:43 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
4 |
08/01/2026 14:17:33 |
|
200 |
System failure: KCE System failure: KCE |
4 |
08/01/2026 11:32:28 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
3 |
08/01/2026 14:12:41 |
|
1703 |
Elevator Failure Start failed
|
2 |
08/01/2026 14:17:22 |
|
1814 |
Elevator Failure Drive unit fault
|
2 |
29/01/2026 10:35:42 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
2 |
08/01/2026 14:12:41 |
|
4017 |
Elevator Failure KCEAPM 12V power failed (battery failure)
|
2 |
08/01/2026 15:26:23 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
11/02/2026 13:02:36 |
|
103 |
False Alarm False Alarm |
1 |
29/01/2026 07:48:35 |
|
1830 |
Elevator Failure LON communication error
|
1 |
23/12/2025 05:59:44 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
1 |
11/02/2026 16:50:54 |