| SYSEVE |
153000 |
System Failure: low: Rif ENGINEER ON SITE |
29 |
05/03/2026 16:52:25 |
| SYSEVE |
153000 |
System Failure OK: low: Rif ENGINEER ON SITE |
28 |
05/03/2026 16:56:10 |
| SYSEVE |
162001 |
System Failure: low: Analyzer MONITORING ON |
12 |
25/05/2026 05:28:37 |
| SYSEVE |
162006 |
System Failure: low: Analyzer DATA_LINK |
12 |
25/05/2026 05:28:37 |
| SYSRCA |
|
Réception Appel Cyclique |
11 |
09/03/2026 07:18:36 |
| DEBEVE |
153104 |
System Failure: low: Rif RIF RESET: RESET BY USER |
5 |
05/03/2026 15:35:34 |
| SYSFAI |
151009 |
System Failure OK: low: Rif MAIN POWER FAIL |
5 |
05/03/2026 16:56:04 |
| SYSFAI |
151009 |
System Failure: low: Rif MAIN POWER FAIL |
4 |
05/03/2026 16:52:25 |
|
124000 |
Temporary Fault Temporary Fault |
3 |
04/03/2026 10:53:47 |
| SYSEVE |
152000 |
System Failure: low: Rif ALARM FROM CAR |
3 |
24/02/2026 11:18:21 |
| SYSEVE |
152004 |
System Failure: low: Rif TEST ALARM FROM CAR (TAT) |
3 |
24/02/2026 11:34:55 |
| SYSFAI |
151014 |
System Failure OK: low: Rif ANALYZER POWER FAIL |
2 |
05/03/2026 16:56:10 |
|
255255 |
False Alarm (Direct Call) False Alarm (Direct Call) |
1 |
23/02/2026 13:06:32 |
|
255255 |
Test Alarm (Direct Call) Test Alarm (Direct Call) |
1 |
24/02/2026 11:36:38 |
| EQUFAI |
1002 |
Elevator OK SAFETY_CIRCUIT_BROKEN |
1 |
05/03/2026 16:57:13 |
| EQUFAI |
1002 |
Test Alarm (Direct Call) SAFETY_CIRCUIT_BROKEN |
1 |
09/03/2026 13:33:15 |
| EQUFAI |
2001 |
Unclassified Alarm (Direct Call) SHAFT_DOOR_CONTACT_OPENED_DURING_DRIVE |
1 |
23/02/2026 13:02:52 |
| SYSEVE |
152001 |
System Failure: low: Rif ALARM FROM CAR ROOF |
1 |
23/02/2026 13:01:10 |
| SYSEVE |
162010 |
System Failure: low: Analyzer PARAMETER CHANGE |
1 |
04/03/2026 17:26:28 |
| SYSEVE |
163004 |
System Failure OK: low: Analyzer CONFIGURATION SET |
1 |
04/03/2026 17:26:28 |
| SYSFAI |
151014 |
System Failure: low: Rif ANALYZER POWER FAIL |
1 |
05/03/2026 16:55:25 |