| SYSRCA |
|
Réception Appel Cyclique |
94 |
10/03/2026 03:33:40 |
| SYSEVE |
153000 |
System Failure OK: low: Rif ENGINEER ON SITE |
15 |
16/02/2026 11:25:49 |
| SYSEVE |
153000 |
System Failure: low: Rif ENGINEER ON SITE |
15 |
16/02/2026 11:17:03 |
| SYSFAI |
151009 |
System Failure OK: low: Rif MAIN POWER FAIL |
8 |
05/03/2026 14:31:27 |
| SYSFAI |
151009 |
System Failure: low: Rif MAIN POWER FAIL |
8 |
05/03/2026 14:31:25 |
| SYSEVE |
152000 |
System Failure: low: Rif ALARM FROM CAR |
7 |
11/02/2026 16:07:49 |
| SYSEVE |
162013 |
System Failure: low: Analyzer FALSE ALARM |
6 |
11/02/2026 16:08:04 |
| SYSFAI |
151009 |
System Failure OK: Rif MAIN POWER FAIL |
5 |
05/03/2026 14:31:27 |
| SYSEVE |
162001 |
System Failure: low: Analyzer MONITORING ON |
4 |
05/03/2026 09:33:52 |
| SYSEVE |
162006 |
System Failure: low: Analyzer DATA_LINK |
4 |
05/03/2026 09:33:52 |
| SYSFAI |
151014 |
System Failure: low: Rif ANALYZER POWER FAIL |
3 |
05/03/2026 09:34:24 |
|
255255 |
Unclassified Alarm (Direct Call) Unclassified Alarm (Direct Call) |
2 |
11/02/2026 16:11:05 |
| EQUFAI |
3001 |
Elevator Failure DOOR_CLOSING_FAILED_TOO_MANY_CLOSING_TRIALS |
2 |
13/02/2026 09:00:35 |
| EQUFAI |
3001 |
Elevator OK DOOR_CLOSING_FAILED_TOO_MANY_CLOSING_TRIALS |
2 |
16/02/2026 11:10:55 |
| SYSEVE |
152004 |
System Failure: low: Rif TEST ALARM FROM CAR (TAT) |
2 |
24/02/2026 09:18:17 |
| SYSFAI |
151014 |
System Failure OK: low: Rif ANALYZER POWER FAIL |
2 |
05/03/2026 09:35:09 |
| EQUFAI |
19092 |
Elevator Failure Unintended car movement detected |
1 |
11/02/2026 16:27:40 |
| EQUFAI |
19092 |
Elevator OK Unintended car movement detected |
1 |
11/02/2026 17:30:04 |
| EQUFAI |
3002 |
Elevator OK REOPEN_DEVICE_ACTIVE_LONGER_1_MINUTE |
1 |
11/02/2026 17:30:52 |
| SYSEVE |
152003 |
System Failure: low: Rif ALARM FROM CAR UNCONDITIONAL |
1 |
11/02/2026 16:08:55 |