| SYSRCA |
|
Réception Appel Cyclique |
92 |
09/03/2026 07:05:36 |
| SYSEVE |
162001 |
System Failure: low: Analyzer MONITORING ON |
4 |
22/01/2026 14:30:34 |
| SYSEVE |
162006 |
System Failure: low: Analyzer DATA_LINK |
4 |
22/01/2026 14:30:34 |
| SYSFAI |
151014 |
System Failure OK: low: Rif ANALYZER POWER FAIL |
4 |
22/01/2026 14:31:45 |
| SYSEVE |
152000 |
System Failure: low: Rif ALARM FROM CAR |
3 |
03/03/2026 12:38:43 |
| SYSEVE |
153000 |
System Failure OK: low: Rif ENGINEER ON SITE |
3 |
22/01/2026 14:30:15 |
| SYSEVE |
153000 |
System Failure: low: Rif ENGINEER ON SITE |
3 |
24/01/2026 07:24:05 |
| SYSEVE |
162010 |
System Failure: low: Analyzer PARAMETER CHANGE |
2 |
22/01/2026 13:40:43 |
| SYSEVE |
162013 |
System Failure: low: Analyzer FALSE ALARM |
2 |
03/03/2026 12:39:08 |
| SYSEVE |
163004 |
System Failure OK: low: Analyzer CONFIGURATION SET |
2 |
22/01/2026 13:40:43 |
|
|
Engineer from Site Engineer from Site |
1 |
17/02/2026 23:58:41 |
|
255255 |
False Alarm (Direct Call) False Alarm (Direct Call) |
1 |
27/02/2026 15:46:08 |
| EQUFAI |
1002 |
Elevator OK SAFETY_CIRCUIT_BROKEN |
1 |
19/12/2025 14:55:11 |
| EQUFAI |
1002 |
Unclassified Alarm (Direct Call) SAFETY_CIRCUIT_BROKEN |
1 |
22/01/2026 13:16:41 |
| SYSEVE |
152003 |
System Failure: low: Rif ALARM FROM CAR UNCONDITIONAL |
1 |
22/01/2026 13:14:48 |
| SYSEVE |
152004 |
System Failure: low: Rif TEST ALARM FROM CAR (TAT) |
1 |
07/01/2026 15:18:56 |