Suivi Activite Telesurveillance 42236630


Infos Telalarme
N° Transmetteur 42236630
N° Equipement 42236630
Voie 1
N° de ligne telephonique 882397104415693
Equipements sur la meme ligne Telephonique 42236630,
Modele et profil TS KNXM - KRM_standard_GPRS_GW-RFD
Version logiciel KRM rif.5.0.2e
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC 26/04/2017 05:45:56
Date dernier appel recu au CCC 09/03/2026 19:01:33
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 251
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSEVE 162001 System Failure: low: Analyzer MONITORING ON 109 05/03/2026 17:39:23
SYSEVE 162006 System Failure: low: Analyzer DATA_LINK 109 05/03/2026 17:39:23
SYSFAI 153019 System Failure: Rif KRM GSM Gateway battery failure 97 09/03/2026 20:01:32
SYSFAI 153019 System Failure OK: Rif KRM GSM Gateway battery failure 96 04/03/2026 05:38:14
SYSRCA Réception Appel Cyclique 92 09/03/2026 03:11:40
124000 Temporary Fault Temporary Fault 21 04/03/2026 15:17:45
SYSEVE 153000 System Failure OK: low: Rif ENGINEER ON SITE 5 05/03/2026 10:19:09
SYSEVE 153000 System Failure: low: Rif ENGINEER ON SITE 5 05/03/2026 10:17:09
255255 Unclassified Alarm (Direct Call) Unclassified Alarm (Direct Call) 3 02/03/2026 09:43:51
EQUFAI 20010 Elevator OK Photocell continuously active or continuously inactive for predetermined stops based on parameter 3-35 3 05/03/2026 09:53:24
SYSEVE 152000 System Failure: low: Rif ALARM FROM CAR 3 02/03/2026 09:41:41
EQUFAI 1002 Elevator Failure SAFETY_CIRCUIT_BROKEN 2 07/03/2026 10:05:15
EQUFAI 1002 Elevator OK SAFETY_CIRCUIT_BROKEN 2 07/03/2026 22:11:59
SYSEVE 152004 System Failure: low: Rif TEST ALARM FROM CAR (TAT) 2 28/01/2026 07:56:54
EQUFAI 20010 Elevator Failure Photocell continuously active or continuously inactive for predetermined stops based on parameter 3-35 1 01/02/2026 22:07:23
SYSEVE 162013 System Failure: low: Analyzer FALSE ALARM 1 26/01/2026 13:50:26