| SYSRCA |
|
Réception Appel Cyclique |
90 |
09/03/2026 21:51:42 |
| SYSFAI |
151009 |
System Failure OK: low: Rif MAIN POWER FAIL |
6 |
09/03/2026 10:02:57 |
| SYSFAI |
151009 |
System Failure: low: Rif MAIN POWER FAIL |
6 |
09/03/2026 10:02:56 |
| SYSEVE |
153000 |
System Failure OK: low: Rif ENGINEER ON SITE |
5 |
04/01/2026 11:52:40 |
| SYSEVE |
153000 |
System Failure: low: Rif ENGINEER ON SITE |
5 |
04/01/2026 11:51:10 |
| SYSEVE |
162001 |
System Failure: low: Analyzer MONITORING ON |
4 |
15/01/2026 11:05:59 |
| SYSEVE |
162006 |
System Failure: low: Analyzer DATA_LINK |
4 |
15/01/2026 11:05:59 |
| SYSEVE |
152000 |
System Failure: low: Rif ALARM FROM CAR |
2 |
04/01/2026 10:25:00 |
| SYSEVE |
152004 |
System Failure: low: Rif TEST ALARM FROM CAR (TAT) |
2 |
27/02/2026 09:52:00 |
| SYSEVE |
162013 |
System Failure: low: Analyzer FALSE ALARM |
2 |
04/01/2026 10:25:45 |
| SYSFAI |
151014 |
System Failure OK: low: Rif ANALYZER POWER FAIL |
2 |
15/01/2026 11:05:39 |
| EQUFAI |
1002 |
Elevator OK SAFETY_CIRCUIT_BROKEN |
1 |
04/01/2026 11:53:22 |
| EQUFAI |
13003 |
Elevator OK DOM_SUPERVISION_FAILED |
1 |
04/01/2026 11:53:24 |