1606 |
Elevator Failure Car door closing failed, too many closing trials
|
217 |
12/02/2026 10:48:17 |
| SYSRCA |
|
Réception Appel Cyclique |
94 |
10/03/2026 02:55:57 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
62 |
12/02/2026 11:25:30 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
52 |
12/02/2026 11:12:09 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
36 |
17/02/2026 08:08:42 |
|
1117 |
Elevator Failure KMI stop switch active
|
29 |
19/12/2025 16:25:56 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
28 |
12/02/2026 11:05:40 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
20 |
19/12/2025 16:18:40 |
|
1044 |
Elevator Failure Drive not OK
|
20 |
19/12/2025 16:18:51 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
20 |
12/02/2026 10:58:37 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
17 |
12/02/2026 10:58:36 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
16 |
12/02/2026 10:50:18 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
12 |
12/02/2026 11:22:10 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
11 |
26/01/2026 11:45:11 |
|
1043 |
Elevator Failure Start permit fault
|
10 |
19/12/2025 16:18:49 |
|
1023 |
Elevator Failure Car door bypass switch active
|
9 |
12/02/2026 11:22:11 |
|
1814 |
Elevator Failure Drive unit fault
|
9 |
19/12/2025 16:16:55 |
|
1181 |
Elevator Failure Door bypass switch misuse |
8 |
19/12/2025 16:15:25 |
|
1607 |
Elevator Failure Reopen device active too long
|
8 |
09/03/2026 17:21:00 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
6 |
12/02/2026 11:07:16 |
|
1010 |
Elevator Failure Safety circuit: blocking device (C4)
|
4 |
19/12/2025 15:31:43 |
|
1140 |
Elevator Failure Safety circuit: Inspection up limit
|
4 |
12/02/2026 11:25:28 |
|
1830 |
Elevator Failure LON communication error
|
4 |
07/02/2026 09:26:37 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
3 |
17/02/2026 08:08:42 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
3 |
12/02/2026 11:59:34 |
|
1035 |
Elevator Failure Unintended movement
|
2 |
19/12/2025 16:24:36 |
|
103 |
False Alarm False Alarm |
1 |
15/01/2026 14:04:41 |