Suivi Activite Telesurveillance 42772709


Infos Telalarme
N° Transmetteur 42772709
N° Equipement 42772709
Voie
N° de ligne telephonique 882397143421197
Equipements sur la meme ligne Telephonique 42772709,
Modele et profil TS KCE - DEFAULT KONE 3G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 22:32:01
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 308
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
1010 Elevator Failure Safety circuit: blocking device (C4) 352 05/03/2026 08:24:05
SYSRCA Réception Appel Cyclique 94 09/03/2026 23:31:56
1008 Elevator Failure Safety circuit: Safety gear (C2) 60 23/02/2026 11:07:08
1140 Elevator Failure Safety circuit: Inspection up limit 31 23/02/2026 11:16:10
1031 Elevator Failure Safety circuit: Landing door opened during drive 30 23/02/2026 11:14:43
1607 Elevator Failure Reopen device active too long 18 03/03/2026 12:21:14
1129 Elevator Failure Inspection drive unit stop button active 12 23/02/2026 11:12:21
1702 Elevator Failure Start timeout 11 05/01/2026 11:12:49
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 8 29/12/2025 15:10:28
1000 Elevator Failure Serial communication broken on board (both TTS channels) 5 23/02/2026 11:02:11
1002 Elevator Failure Serial communication broken on board (TTS-1) 5 23/02/2026 11:03:16
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 5 03/03/2026 13:17:01
4018 Elevator Failure KCEAPM has no connection to KCECPU 4 03/03/2026 13:28:31
100 Temporary Fault Unclassified Alarm 3 03/02/2026 14:51:05
1161 Elevator Failure KCEDZS board failure - Self check failed 3 23/02/2026 11:02:11
1839 Elevator Failure KCEMSC missing from TTS-1 3 25/02/2026 05:32:46
1840 Elevator Failure KCEMSC missing from TTS-2 3 25/02/2026 05:32:46
1003 Elevator Failure Serial communication broken on board (TTS-2) 2 23/02/2026 11:02:11
1004 Elevator Failure TTS serial communication broken. One channel 2 29/12/2025 14:29:22
1703 Elevator Failure Start failed 2 05/01/2026 11:12:56
2000 Elevator Failure Missing COP 2 23/02/2026 11:02:15
2339 Elevator Failure KCEDZS 24 V power supply failure 2 23/02/2026 11:02:11
102 Temporary Fault Test Alarm 1 23/02/2026 11:02:42
103 False Alarm False Alarm 1 23/12/2025 15:52:49
1830 Elevator Failure LON communication error 1 25/02/2026 05:32:31
<-- Retour KOF