| SYSRCA |
|
Réception Appel Cyclique |
94 |
09/03/2026 14:30:43 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
9 |
13/02/2026 09:26:31 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
6 |
13/02/2026 09:30:10 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
13/02/2026 09:25:11 |
|
1607 |
Elevator Failure Reopen device active too long
|
4 |
01/03/2026 17:24:13 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
4 |
13/02/2026 10:34:39 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
3 |
13/02/2026 09:24:38 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
3 |
13/02/2026 09:24:38 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
2 |
24/12/2025 15:36:33 |
|
1023 |
Elevator Failure Car door bypass switch active
|
2 |
24/12/2025 15:37:13 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
2 |
03/03/2026 00:04:55 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
2 |
03/03/2026 00:04:55 |
|
1702 |
Elevator Failure Start timeout
|
1 |
23/12/2025 18:36:39 |