| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 13:04:37 |
|
1607 |
Elevator Failure Reopen device active too long
|
18 |
03/03/2026 08:25:34 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
17 |
06/01/2026 09:31:58 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
16 |
17/12/2025 12:58:26 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
15 |
17/12/2025 13:00:31 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
6 |
17/12/2025 12:56:06 |
|
1000 |
Elevator Failure Serial communication broken on board (both TTS channels)
|
4 |
17/12/2025 12:56:01 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
4 |
17/12/2025 12:27:33 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
4 |
28/01/2026 14:45:07 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
4 |
28/01/2026 14:45:07 |
|
2339 |
Elevator Failure KCEDZS 24 V power supply failure |
4 |
17/12/2025 12:56:01 |
|
1161 |
Elevator Failure KCEDZS board failure - Self check failed
|
3 |
17/12/2025 12:56:01 |
|
1614 |
Elevator Failure Car door close end limit stuck
|
3 |
12/12/2025 07:08:49 |
|
1003 |
Elevator Failure Serial communication broken on board (TTS-2)
|
2 |
17/12/2025 12:56:01 |
|
1702 |
Elevator Failure Start timeout
|
2 |
05/01/2026 16:13:45 |
|
1703 |
Elevator Failure Start failed
|
2 |
17/12/2025 12:33:33 |
|
1830 |
Elevator Failure LON communication error
|
2 |
28/01/2026 14:44:52 |
|
4002 |
Elevator Failure KCEAPM phone line missing
|
2 |
05/03/2026 16:56:28 |