| SYSRCA |
|
Réception Appel Cyclique |
95 |
09/03/2026 06:14:57 |
|
1140 |
Elevator Failure Safety circuit: Inspection up limit
|
12 |
17/12/2025 14:03:21 |
|
1703 |
Elevator Failure Start failed
|
10 |
17/12/2025 14:17:06 |
|
1607 |
Elevator Failure Reopen device active too long
|
6 |
12/02/2026 18:32:19 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
4 |
17/12/2025 14:38:07 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
4 |
17/12/2025 13:50:23 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
4 |
17/12/2025 14:43:13 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
4 |
17/02/2026 02:37:26 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
4 |
29/12/2025 10:32:46 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
3 |
17/02/2026 02:37:26 |
|
1830 |
Elevator Failure LON communication error
|
2 |
17/02/2026 02:37:08 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
2 |
29/12/2025 10:35:21 |