| SYSRCA |
|
Réception Appel Cyclique |
95 |
10/03/2026 01:09:07 |
|
1607 |
Elevator Failure Reopen device active too long
|
94 |
03/03/2026 10:45:57 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
83 |
08/03/2026 15:56:10 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
32 |
06/03/2026 13:39:08 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
16 |
19/02/2026 18:41:21 |
|
1044 |
Elevator Failure Drive not OK
|
8 |
06/03/2026 13:34:14 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
4 |
06/03/2026 13:33:09 |
|
1099 |
Elevator Failure Main stop switch open |
4 |
06/03/2026 13:34:08 |
|
1113 |
Elevator Failure TTS communication stuck
|
4 |
06/03/2026 13:34:17 |
|
1161 |
Elevator Failure KCEDZS board failure - Self check failed
|
4 |
06/03/2026 13:33:09 |
|
1820 |
Elevator Failure Drive communication broken
|
4 |
06/03/2026 13:34:09 |
|
1830 |
Elevator Failure LON communication error
|
4 |
14/02/2026 19:54:24 |
|
2339 |
Elevator Failure KCEDZS 24 V power supply failure |
4 |
06/03/2026 13:33:08 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
4 |
02/03/2026 15:12:15 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
3 |
14/02/2026 19:54:41 |
|
101 |
Real Alarm Real Alarm |
2 |
06/03/2026 13:02:43 |
|
1703 |
Elevator Failure Start failed
|
2 |
06/03/2026 13:42:46 |
|
1799 |
Elevator Failure Self check mode stuck.
|
2 |
06/03/2026 13:33:18 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
2 |
14/02/2026 19:54:41 |