| SYSRCA |
|
Réception Appel Cyclique |
95 |
10/03/2026 03:42:48 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
51 |
08/03/2026 15:56:33 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
32 |
07/02/2026 12:40:26 |
|
1161 |
Elevator Failure KCEDZS board failure - Self check failed
|
28 |
05/02/2026 17:53:08 |
|
1117 |
Elevator Failure KMI stop switch active
|
18 |
16/02/2026 09:43:56 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
12 |
07/02/2026 12:46:15 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
12 |
07/02/2026 12:46:14 |
|
2000 |
Elevator Failure Missing COP
|
12 |
16/02/2026 09:31:33 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
11 |
07/02/2026 12:46:23 |
|
2300 |
Elevator Failure KCEDZS internal RFID failure |
10 |
13/02/2026 17:44:55 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
10 |
16/02/2026 10:43:33 |
|
1003 |
Elevator Failure Serial communication broken on board (TTS-2)
|
9 |
23/12/2025 09:11:06 |
|
1607 |
Elevator Failure Reopen device active too long
|
9 |
04/02/2026 20:13:31 |
|
1000 |
Elevator Failure Serial communication broken on board (both TTS channels)
|
6 |
23/12/2025 09:09:15 |
|
1702 |
Elevator Failure Start timeout
|
6 |
05/02/2026 17:53:19 |
|
2339 |
Elevator Failure KCEDZS 24 V power supply failure |
3 |
23/12/2025 09:09:15 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
2 |
16/02/2026 09:38:27 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
2 |
21/12/2025 11:17:51 |
|
1830 |
Elevator Failure LON communication error
|
2 |
10/12/2025 11:15:25 |
|
4002 |
Elevator Failure KCEAPM phone line missing
|
2 |
08/03/2026 10:10:56 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
2 |
21/12/2025 13:30:25 |