Suivi Activite Telesurveillance 42955808


Infos Telalarme
N° Transmetteur 42955808
N° Equipement 42955808
Voie
N° de ligne telephonique 882396869629723
Equipements sur la meme ligne Telephonique 42955808,
Modele et profil TS KCE - DEFAULT
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 10/03/2026 02:43:06
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 184
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSRCA Réception Appel Cyclique 95 10/03/2026 03:42:48
1002 Elevator Failure Serial communication broken on board (TTS-1) 51 08/03/2026 15:56:33
1129 Elevator Failure Inspection drive unit stop button active 32 07/02/2026 12:40:26
1161 Elevator Failure KCEDZS board failure - Self check failed 28 05/02/2026 17:53:08
1117 Elevator Failure KMI stop switch active 18 16/02/2026 09:43:56
1839 Elevator Failure KCEMSC missing from TTS-1 12 07/02/2026 12:46:15
1840 Elevator Failure KCEMSC missing from TTS-2 12 07/02/2026 12:46:14
2000 Elevator Failure Missing COP 12 16/02/2026 09:31:33
1004 Elevator Failure TTS serial communication broken. One channel 11 07/02/2026 12:46:23
2300 Elevator Failure KCEDZS internal RFID failure 10 13/02/2026 17:44:55
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 10 16/02/2026 10:43:33
1003 Elevator Failure Serial communication broken on board (TTS-2) 9 23/12/2025 09:11:06
1607 Elevator Failure Reopen device active too long 9 04/02/2026 20:13:31
1000 Elevator Failure Serial communication broken on board (both TTS channels) 6 23/12/2025 09:09:15
1702 Elevator Failure Start timeout 6 05/02/2026 17:53:19
2339 Elevator Failure KCEDZS 24 V power supply failure 3 23/12/2025 09:09:15
1031 Elevator Failure Safety circuit: Landing door opened during drive 2 16/02/2026 09:38:27
1091 Elevator Failure Lift on final limit magnet 2 21/12/2025 11:17:51
1830 Elevator Failure LON communication error 2 10/12/2025 11:15:25
4002 Elevator Failure KCEAPM phone line missing 2 08/03/2026 10:10:56
4018 Elevator Failure KCEAPM has no connection to KCECPU 2 21/12/2025 13:30:25
<-- Retour KOF