| SYSRCA |
|
Réception Appel Cyclique |
91 |
09/03/2026 15:15:41 |
| SYSEVE |
162001 |
System Failure: low: Analyzer MONITORING ON |
11 |
22/01/2026 10:18:19 |
| SYSEVE |
162006 |
System Failure: low: Analyzer DATA_LINK |
11 |
22/01/2026 10:18:19 |
| SYSFAI |
151014 |
System Failure OK: low: Rif ANALYZER POWER FAIL |
10 |
22/01/2026 10:20:24 |
| SYSEVE |
153000 |
System Failure OK: low: Rif ENGINEER ON SITE |
6 |
09/02/2026 10:32:50 |
| SYSEVE |
153000 |
System Failure: low: Rif ENGINEER ON SITE |
6 |
09/02/2026 10:20:34 |
| SYSFAI |
151009 |
System Failure OK: low: Rif MAIN POWER FAIL |
3 |
22/01/2026 09:57:30 |
| SYSFAI |
151009 |
System Failure: low: Rif MAIN POWER FAIL |
3 |
22/01/2026 09:27:21 |
| SYSEVE |
152004 |
System Failure: low: Rif TEST ALARM FROM CAR (TAT) |
2 |
09/02/2026 10:20:45 |
| SYSFAI |
151014 |
System Failure: low: Rif ANALYZER POWER FAIL |
2 |
22/01/2026 09:25:06 |
| EQUFAI |
20009 |
Elevator OK RBO device is not ok |
1 |
09/02/2026 10:32:45 |
| EQUFAI |
3002 |
Elevator Failure REOPEN_DEVICE_ACTIVE_LONGER_1_MINUTE |
1 |
20/01/2026 12:59:05 |
| EQUFAI |
3002 |
Elevator OK REOPEN_DEVICE_ACTIVE_LONGER_1_MINUTE |
1 |
09/02/2026 10:32:49 |