| SYSRCA |
|
Réception Appel Cyclique |
92 |
09/03/2026 04:15:00 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
8 |
15/01/2026 15:05:36 |
|
1607 |
Elevator Failure Reopen device active too long
|
6 |
05/03/2026 13:24:21 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
4 |
19/02/2026 10:43:15 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
4 |
12/01/2026 15:46:57 |
|
1702 |
Elevator Failure Start timeout
|
4 |
15/01/2026 12:06:37 |
|
1830 |
Elevator Failure LON communication error
|
4 |
06/03/2026 08:02:03 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
4 |
06/03/2026 08:02:20 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
4 |
06/03/2026 08:02:20 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
3 |
15/01/2026 16:40:23 |
|
101 |
Real Alarm Real Alarm |
2 |
15/01/2026 11:53:09 |
|
1056 |
Elevator Failure Movement risk during start or stop sequence (motor movement) counter |
2 |
15/01/2026 11:29:03 |
|
100 |
Unclassified Alarm Unclassified Alarm |
1 |
19/02/2026 10:42:57 |