| SYSRCA |
|
Réception Appel Cyclique |
95 |
10/03/2026 00:14:58 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
31 |
03/03/2026 02:49:22 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
8 |
22/01/2026 10:15:35 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
22/01/2026 10:16:47 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
3 |
11/02/2026 10:21:32 |
|
1607 |
Elevator Failure Reopen device active too long
|
2 |
09/03/2026 08:40:11 |
|
1830 |
Elevator Failure LON communication error
|
2 |
19/12/2025 03:00:19 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
2 |
19/12/2025 03:00:37 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
2 |
19/12/2025 03:00:37 |
|
103 |
False Alarm False Alarm |
1 |
11/02/2026 09:20:27 |