| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 04:41:51 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
40 |
03/03/2026 14:54:08 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
29 |
13/01/2026 16:28:24 |
|
1607 |
Elevator Failure Reopen device active too long
|
18 |
25/02/2026 18:16:25 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
16 |
19/02/2026 16:21:43 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
10 |
04/03/2026 09:19:24 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
9 |
04/03/2026 09:19:24 |
|
1117 |
Elevator Failure KMI stop switch active
|
8 |
13/01/2026 16:15:41 |
|
1161 |
Elevator Failure KCEDZS board failure - Self check failed
|
7 |
14/02/2026 17:59:41 |
|
1114 |
Elevator Failure Pit inspection mode input failure |
6 |
13/01/2026 16:31:13 |
|
1181 |
Elevator Failure Door bypass switch misuse |
4 |
13/01/2026 16:16:00 |
|
2337 |
Elevator Failure KCEDZS board failure - Faulty magnet sensor |
4 |
14/02/2026 17:59:41 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
3 |
13/01/2026 16:15:05 |
|
100 |
Temporary Fault Unclassified Alarm |
2 |
12/01/2026 19:18:21 |
|
1066 |
Elevator Failure TTS2 communication fault |
2 |
13/01/2026 16:15:41 |
|
1830 |
Elevator Failure LON communication error
|
2 |
04/03/2026 09:19:07 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
2 |
13/01/2026 18:18:21 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
2 |
13/01/2026 17:17:20 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
1 |
13/01/2026 16:39:05 |