| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 13:29:42 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
74 |
06/03/2026 15:50:10 |
|
1607 |
Elevator Failure Reopen device active too long
|
24 |
04/03/2026 13:58:03 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
20 |
04/02/2026 10:58:46 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
8 |
04/02/2026 11:33:47 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
04/02/2026 11:35:25 |
|
1010 |
Elevator Failure Safety circuit: blocking device (C4)
|
4 |
04/02/2026 10:51:18 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
4 |
04/02/2026 11:14:54 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
4 |
04/02/2026 11:37:06 |
|
1702 |
Elevator Failure Start timeout
|
2 |
27/01/2026 09:56:10 |
|
1830 |
Elevator Failure LON communication error
|
2 |
02/01/2026 00:50:30 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
2 |
02/01/2026 00:50:47 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
2 |
02/01/2026 00:50:47 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
2 |
04/02/2026 13:46:49 |
|
102 |
Temporary Fault Test Alarm |
1 |
04/02/2026 11:40:28 |