| SYSRCA |
|
Réception Appel Cyclique |
94 |
09/03/2026 23:44:56 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
20 |
16/01/2026 04:49:56 |
|
200 |
System failure: KCE System failure: KCE |
14 |
27/02/2026 02:23:41 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
4 |
05/03/2026 17:18:19 |
|
1702 |
Elevator Failure Start timeout
|
4 |
05/03/2026 17:18:10 |
|
2000 |
Elevator Failure Missing COP
|
4 |
14/01/2026 13:36:54 |
|
102 |
Temporary Fault Test Alarm |
3 |
14/01/2026 13:40:17 |
|
1607 |
Elevator Failure Reopen device active too long
|
2 |
30/12/2025 10:23:40 |
|
1830 |
Elevator Failure LON communication error
|
2 |
12/01/2026 02:48:32 |
|
4017 |
Elevator Failure KCEAPM 12V power failed (battery failure)
|
2 |
02/02/2026 16:12:13 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
27/12/2025 13:13:22 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
1 |
12/01/2026 02:48:49 |