| SYSRCA |
|
Réception Appel Cyclique |
92 |
09/03/2026 23:00:10 |
|
1033 |
Elevator Failure safety circuit: Buffers supervision. Up input failure
|
56 |
18/02/2026 11:01:54 |
|
1039 |
Elevator Failure Door open monitoring functioned
|
56 |
18/02/2026 11:01:47 |
|
1015 |
Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
|
55 |
18/02/2026 11:01:46 |
|
1188 |
Elevator Failure Safety circuit: Buffers up input (H7) |
53 |
18/02/2026 11:01:54 |
|
1140 |
Elevator Failure Safety circuit: Inspection up limit
|
51 |
18/02/2026 10:40:45 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
37 |
27/02/2026 00:46:36 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
36 |
18/02/2026 10:56:25 |
|
1117 |
Elevator Failure KMI stop switch active
|
27 |
18/02/2026 10:38:17 |
|
1111 |
Elevator Failure KCEFUI SPI failure |
19 |
18/02/2026 10:32:49 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
16 |
18/02/2026 10:38:12 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
15 |
18/02/2026 10:38:21 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
15 |
18/02/2026 10:38:12 |
|
1075 |
Elevator Failure KCEFUI board disconnected
|
11 |
18/02/2026 10:32:16 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
10 |
18/02/2026 10:32:59 |
|
1081 |
Elevator Failure KCEMSC board failure - Input comparison
|
10 |
18/02/2026 10:36:26 |
|
1013 |
Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
|
8 |
18/02/2026 10:05:57 |
|
1023 |
Elevator Failure Car door bypass switch active
|
8 |
18/02/2026 10:32:57 |
|
1116 |
Elevator Failure KMI safety chain bypass jumper at place
|
6 |
18/02/2026 10:23:58 |
|
1181 |
Elevator Failure Door bypass switch misuse |
6 |
18/02/2026 10:15:22 |
|
1132 |
Elevator Failure Pit inspection mode reset input active too long |
4 |
18/02/2026 10:53:03 |
|
1607 |
Elevator Failure Reopen device active too long
|
4 |
27/02/2026 12:00:22 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
4 |
18/02/2026 11:25:55 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
3 |
18/02/2026 10:29:17 |
|
1830 |
Elevator Failure LON communication error
|
3 |
13/02/2026 19:41:33 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
3 |
18/02/2026 10:50:44 |