Suivi Activite Telesurveillance 43131194


Infos Telalarme
N° Transmetteur 43131194
N° Equipement 43131194
Voie
N° de ligne telephonique 882397104415419
Equipements sur la meme ligne Telephonique 43131194,
Modele et profil TS KCE - DEFAULT
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC 27/06/2017 10:05:06
Date dernier appel recu au CCC 09/03/2026 09:55:05
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 116
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSRCA Réception Appel Cyclique 76 09/03/2026 10:55:00
1002 Elevator Failure Serial communication broken on board (TTS-1) 34 08/03/2026 17:10:46
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 19 05/02/2026 08:12:26
1039 Elevator Failure Door open monitoring functioned 18 05/02/2026 08:22:21
1129 Elevator Failure Inspection drive unit stop button active 15 05/02/2026 08:17:41
1188 Elevator Failure Safety circuit: Buffers up input (H7) 14 05/02/2026 08:22:21
1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8) 13 05/02/2026 08:22:21
1091 Elevator Failure Lift on final limit magnet 8 05/02/2026 08:02:17
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 6 05/02/2026 09:06:51
1140 Elevator Failure Safety circuit: Inspection up limit 5 05/02/2026 08:15:23
1008 Elevator Failure Safety circuit: Safety gear (C2) 4 05/02/2026 08:03:47
1009 Elevator Failure Safety circuit: Emergency exit (C3) 4 05/02/2026 08:15:58
1010 Elevator Failure Safety circuit: blocking device (C4) 4 05/02/2026 08:15:40
1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7) 3 08/01/2026 12:04:27
102 Temporary Fault Test Alarm 2 13/01/2026 15:30:27
1109 Elevator Failure Landing door not opened after top of car inspection 2 05/02/2026 08:18:13
100 Temporary Fault Unclassified Alarm 1 13/01/2026 15:34:30
1607 Elevator Failure Reopen device active too long 1 13/01/2026 16:33:49
<-- Retour KOF