| SYSRCA |
|
Réception Appel Cyclique |
94 |
09/03/2026 17:50:47 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
68 |
24/01/2026 21:15:27 |
|
1607 |
Elevator Failure Reopen device active too long
|
53 |
24/02/2026 10:13:29 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
33 |
25/01/2026 10:26:23 |
|
1003 |
Elevator Failure Serial communication broken on board (TTS-2)
|
26 |
24/01/2026 17:50:14 |
|
1000 |
Elevator Failure Serial communication broken on board (both TTS channels)
|
23 |
24/01/2026 20:52:58 |
|
1055 |
Elevator Failure Safety circuit: power supply voltage out of 10 % range
|
23 |
24/01/2026 18:13:46 |
|
1057 |
Elevator Failure Safety circuit: power supply voltage out of 20 % range
|
18 |
24/01/2026 18:13:46 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
15 |
25/01/2026 10:26:31 |
|
1056 |
Elevator Failure Safety circuit: power supply voltage out of 15 % range
|
13 |
24/01/2026 18:13:46 |
|
1079 |
Elevator Failure KCEMSC board failure - 100V power supply
|
10 |
24/01/2026 18:13:51 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
10 |
25/01/2026 10:26:23 |
|
1051 |
Elevator Failure KCEMSC board failure - Safety input common test
|
9 |
25/01/2026 10:25:28 |
|
1820 |
Elevator Failure Drive communication broken
|
9 |
24/01/2026 17:36:55 |
|
1081 |
Elevator Failure KCEMSC board failure - Input comparison
|
7 |
25/01/2026 10:25:28 |
|
1135 |
Elevator Failure Safety output control signal failure (Relay A, K51) |
7 |
25/01/2026 10:25:28 |
|
1052 |
Elevator Failure KCEMSC board failure - Safety input test
|
6 |
25/01/2026 10:25:28 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
6 |
07/03/2026 12:45:00 |
|
1062 |
Elevator Failure KCEMSC board failure - No reciprocal communication
|
5 |
25/01/2026 10:25:28 |
|
1175 |
Elevator Failure Safety system in Safe mode
|
5 |
25/01/2026 10:25:28 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
5 |
07/03/2026 12:44:58 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
4 |
16/12/2025 15:16:23 |
|
1044 |
Elevator Failure Drive not OK
|
4 |
24/01/2026 17:34:27 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
4 |
16/12/2025 15:10:21 |
|
1099 |
Elevator Failure Main stop switch open |
4 |
16/12/2025 15:10:20 |
|
1179 |
Elevator Failure KCEMSC DIP switch compatibility failure
|
4 |
24/01/2026 21:15:26 |
|
1799 |
Elevator Failure Self check mode stuck.
|
4 |
25/01/2026 10:25:31 |
|
1097 |
Elevator Failure Device picked fault |
3 |
24/01/2026 19:56:26 |
|
1830 |
Elevator Failure LON communication error
|
3 |
24/01/2026 17:34:40 |
|
1007 |
Elevator Failure Safety circuit: Final limit (C1)
|
2 |
24/01/2026 20:31:44 |
|
1066 |
Elevator Failure TTS2 communication fault |
2 |
18/01/2026 15:34:08 |
|
2000 |
Elevator Failure Missing COP
|
1 |
24/01/2026 17:09:02 |